682 resultados para ligament


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Wound healing process involves the activation of extracellular matrix components, remodeling enzymes, cellular adhesion molecules, growth factors, cytokines and chemokines genes. However, the molecular patterns underlying the healing process periapical environment remain unclear. Here we hypothesized that endodontic infection might result in an imbalance in the expression of wound healing genes involved in the pathogenesis of periapical lesions. Furthermore, we suggest that differential expression of wound healing markers in active and latent granulomas could account for different clinical outcomes for such lesions. Methods: Study samples consisted of 93 periapical granulomas collected after endodontic surgeries and 24 healthy periodontal ligament tissues collected from premolars extracted for orthodontic purposes as control samples. Of these, 10 periapical granulomas and 5 healthy periapical tissues were used for expression analysis of 84 wound healing genes by using a pathway-specific real-time polymerase chain reaction array. The remaining 83 granulomas and all 24 control specimens were used to validate the obtained array data by real-time polymerase chain reaction. Observed variations in expression of wound healing genes were analyzed according to the classification of periapical granulomas as active/progressive versus inactive/stable (as determined by receptor activator for nuclear factor kappa B ligand/osteoprotegerin expression ratio). Results: We observed a marked increase of 5-fold or greater in SERPINE1, TIMP1, COL1A1, COL5A1, VTN, CTGF, FGF7, TGFB1, TNF, CXCL11, ITGA4, and ITGA5 genes in the periapical granulomas when compared with control samples. SERPINE1, TIMP1, COL1A1, TGFB1, and ITGA4 mRNA expression was significantly higher in inactive compared with active periapical granulomas (P < .001), whereas TNF and CXCL11 mRNA expression was higher in active lesions (P < .001). Conclusions: The identification of novel gene targets that curb the progression status of periapical lesions might contribute to a more accurate diagnosis and lead to treatment modalities more conducive to endodontic success. (J Endod 2012;38:185-190)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose of this study was to evaluate the influence of miniscrew dental root proximity on its late stability degree. 40 miniscrews were inserted between maxillary second premolars and first molars for anterior retraction. Post-surgical radiographs were used to measure the septum width in the insertion site, insertion height, distal and mesial distance from miniscrew to dental root, and the smallest distance between miniscrew and dental root. The miniscrews were divided in two groups according to septum width: ?3 mm (20 miniscrews) and >3 mm (20 miniscrews). The soft tissue in the insertion site, sensitivity during load, plaque around the miniscrew, and evaluation period were also considered. The results showed no significant difference in miniscrew mobility degree and success rate between groups. Miniscrew dental root proximity did not influence the stability and success rate when the distance between the miniscrew and dental root indicated no periodontal ligament invasion. The overall success rate was 90% and no variable was associated with miniscrew failure. Nevertheless, patient sensitivity was frequently associated with some degree of mini-implant mobility. The septum width did not influence the stability and success rate of this anchorage system, but the extreme root proximity did.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Apresentar um dispositivo biomecânico para o estudo da reconstrução do ligamento patelofemoral medial (LPFM) e sua isometricidade. MÉTODOS: Foi desenvolvido um sistema biomecânico acessível, que permite a aplicação de forças fisiológicas e não fisiológicas no joelho, através de um braço mecânico e aplicação de pesos e contrapesos, possibilitando a execução de diferentes estudos, além de ter um sistema de medidas bastante preciso de aferição de distâncias entre diferentes estruturas para análise dos experimentos. Este artigo descreve a montagem deste sistema, além de sugerir algumas aplicações práticas. Foram estudados seis joelhos de cadáveres. Os joelhos foram preparados em uma máquina de ensaios desenvolvida no Laboratório de Biomecânica do IOT HC FMUSP, que permitiu a avaliação dinâmica do comportamento patelar, quantificando a sua lateralização entre 0 e 120 graus. A diferença entre as distâncias encontradas, com e sem carga, aplicada na patela foram agrupadas segundo o ângulo de fixação do enxerto (0°, 30°, 60° e 90°) e situação do joelho (íntegro, reconstruído e lesado). RESULTADOS: Houve uma tendência em ocorrer menor desvio lateral em ângulos de fixação acima de 30 graus de flexão, principalmente entre os ângulos entre 45° e 60° graus de flexão, após a reconstrução. Para os demais ângulos não houve significância estatística. CONCLUSÃO: O método desenvolvido é uma ferramenta útil para os estudos da articulação patelofemoral, além de ter um sistema de medidas bastante preciso de aferição de distâncias entre diferentes estruturas e permitir a sua utilização em instituições com menos recursos disponíveis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Realizar um estudo anatômico do ligamento colateral medial, um importante estabilizador do cotovelo, em diferentes graus de flexo-extensão do cotovelo. MÉTODOS: Foram dissecados 40 cotovelos para analisar o comportamento funcional das bandas anterior, posterior e transversa do ligamento nas manobras de estresse em valgo do cotovelo durante seu movimento de flexão e extensão em diferentes graus. Determinou-se dois grupos: no GPA foi seccionado, a banda posterior do ligamento, depois a cápsula articular e, por fim, a banda anterior; no GAP, a ordem de dissecação foi inversa. RESULTADOS: No GPA observou-se instabilidade somente na terceira etapa e a média de abertura foi maior entre 50&º e 70&º de flexão de cotovelo; no GAP, a instabilidade apareceu desde a primeira etapa e os graus de flexão com maior instabilidade foram nos mesmos do grupo A. CONCLUSÃO: A banda anterior do ligamento colateral medial do cotovelo é o mais importante estabilizador na instabilidade em valgo do cotovelo e sua atuação principal acontece entre 50º e 70º de flexão do cotovelo. Nível de evidência III, Estudo Diagnóstico - Investigação de um exame para diagnóstico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The knee joint is a key structure of the human locomotor system. The knowledge of how each single anatomical structure of the knee contributes to determine the physiological function of the knee, is of fundamental importance for the development of new prostheses and novel clinical, surgical, and rehabilitative procedures. In this context, a modelling approach is necessary to estimate the biomechanic function of each anatomical structure during daily living activities. The main aim of this study was to obtain a subject-specific model of the knee joint of a selected healthy subject. In particular, 3D models of the cruciate ligaments and of the tibio-femoral articular contact were proposed and developed using accurate bony geometries and kinematics reliably recorded by means of nuclear magnetic resonance and 3D video-fluoroscopy from the selected subject. Regarding the model of the cruciate ligaments, each ligament was modelled with 25 linear-elastic elements paying particular attention to the anatomical twisting of the fibres. The devised model was as subject-specific as possible. The geometrical parameters were directly estimated from the experimental measurements, whereas the only mechanical parameter of the model, the elastic modulus, had to be considered from the literature because of the invasiveness of the needed measurements. Thus, the developed model was employed for simulations of stability tests and during living activities. Physiologically meaningful results were always obtained. Nevertheless, the lack of subject-specific mechanical characterization induced to design and partially develop a novel experimental method to characterize the mechanics of the human cruciate ligaments in living healthy subjects. Moreover, using the same subject-specific data, the tibio-femoral articular interaction was modelled investigating the location of the contact point during the execution of daily motor tasks and the contact area at the full extension with and without the whole body weight of the subject. Two different approaches were implemented and their efficiency was evaluated. Thus, pros and cons of each approach were discussed in order to suggest future improvements of this methodologies. The final results of this study will contribute to produce useful methodologies for the investigation of the in-vivo function and pathology of the knee joint during the execution of daily living activities. Thus, the developed methodologies will be useful tools for the development of new prostheses, tools and procedures both in research field and in diagnostic, surgical and rehabilitative fields.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Total ankle arthroplasty (TAA) is still not as satisfactory as total hip and total knee arthroplasty. For the TAA to be considered a valuable alternative to ankle arthrodesis, an effective range of ankle mobility must be recovered. The disappointing clinical results of the current generation of TAA are mostly related to poor understanding of the structures guiding ankle joint mobility. A new design (BOX Ankle) has been developed, uniquely able to restore physiologic ankle mobility and a natural relationship between the implanted components and the retained ligaments. For the first time the shapes of the tibial and talar components in the sagittal plane were designed to be compatible with the demonstrated ligament isometric rotation. This resulted in an unique motion at the replaced ankle where natural sliding as well as rolling motion occurs while at the same time full conformity is maintained between the three components throughout the flexion arc. According to prior research, the design features a spherical convex tibial component, a talar component with radius of curvature in the sagittal plane longer than that of the natural talus, and a fully conforming meniscal component. After computer-based modelling and preliminary observations in several trial implantation in specimens, 126 patients were implanted in the period July 2003 – December 2008. 75 patients with at least 6 months follow-up are here reported. Mean age was 62,6 years (range 22 – 80), mean follow-up 20,2 months. The AOFAS clinical score systems were used to assess patient outcome. Radiographs at maximal dorsiflexion and maximal plantar flexion confirmed the meniscalbearing component moves anteriorly during dorsiflexion and posteriorly during plantarflexion. Frontal and lateral radiographs in the patients, show good alignment of the components, and no signs of radiolucency or loosening. The mean AOFAS score was observed to go from 41 pre-op to 74,6 at 6 month follow-up, with further improvement at the following follow-up. These early results reveal satisfactory clinical scores, with good recovery of range of motion and reduction of pain. Radiographic assessment reveals good osteointegration. All these preliminary results confirm biomechanical studies and the validity of this novel ligamentcompatible prosthesis design. Surely it will be important to re-evaluate these patients later.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sports biomechanics describes human movement from a performance enhancement and an injury reduction perspective. In this respect, the purpose of sports scientists is to support coaches and physicians with reliable information about athletes’ technique. The lack of methods allowing for in-field athlete evaluation as well as for accurate joint force estimates represents, to date, the main limitation to this purpose. The investigations illustrated in the present thesis aimed at providing a contribution towards the development of the above mentioned methods. Two complementary approaches were adopted: a Low Resolution Approach – related to performance assessment – where the use of wearable inertial measurement units is exploited during different phases of sprint running, and a High Resolution Approach – related to joint kinetics estimate for injury prevention – where subject-specific, non-rigid constraints for knee joint kinematic modelling used in multi-body optimization techniques are defined. Results obtained using the Low Resolution Approach indicated that, due to their portability and inexpensiveness, inertial measurement systems are a valid alternative to laboratory-based instrumentation for in-field performance evaluation of sprint running. Using acceleration and angular velocity data, the following quantities were estimated: trunk inclination and angular velocity, instantaneous horizontal velocity and displacement of a point approximating the centre of mass, and stride and support phase durations. As concerns the High Resolution Approach, results indicated that the length of the anterior cruciate and lateral collateral ligaments decreased, while that of the deep bundle of the medial collateral ligament increased significantly during flexion. Variations of the posterior cruciate and the superficial bundle of the medial collateral ligament lengths were concealed by the experimental indeterminacy. A mathematical model was provided that allowed the estimate of subject-specific ligament lengths as a function of knee flexion and that can be integrated in a multi-body optimization procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relevance of human joint models was shown in the literature. In particular, the great importance of models for the joint passive motion simulation (i.e. motion under virtually unloaded conditions) was outlined. They clarify the role played by the principal anatomical structures of the articulation, enhancing the comprehension of surgical treatments, and in particular the design of total ankle replacement and ligament reconstruction. Equivalent rigid link mechanisms proved to be an efficient tool for an accurate simulation of the joint passive motion. This thesis focuses on the ankle complex (i.e. the anatomical structure composed of the tibiotalar and the subtalar joints), which has a considerable role in human locomotion. The lack of interpreting models of this articulation and the poor results of total ankle replacement arthroplasty have strongly suggested devising new mathematical models capable of reproducing the restraining function of each structure of the joint and of replicating the relative motion of the bones which constitute the joint itself. In this contest, novel equivalent mechanisms are proposed for modelling the ankle passive motion. Their geometry is based on the joint’s anatomical structures. In particular, the role of the main ligaments of the articulation is investigated under passive conditions by means of nine 5-5 fully parallel mechanisms. Based on this investigation, a one-DOF spatial mechanism is developed for modelling the passive motion of the lower leg. The model considers many passive structures constituting the articulation, overcoming the limitations of previous models which took into account few anatomical elements of the ankle complex. All the models have been identified from experimental data by means of optimization procedure. Then, the simulated motions have been compared to the experimental one, in order to show the efficiency of the approach and thus to deduce the role of each anatomical structure in the ankle kinematic behavior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La rottura del Legamento Crociato Craniale (LCCr) rappresenta una delle patologie ortopediche di maggiore riscontro clinico nella specie canina. In seguito a rottura del LCCr si presenta un continuo slittamento craniale della tibia il quale esita in un processo osteoartrosico. La risoluzione chirurgica rappresenta la migliore soluzione terapeutica. Le tecniche chirurgiche extra-articolari con sfruttamento dei punti isometrici del ginocchio si presentano come delle procedure molto diffuse e utilizzate. Questa tesi propone di validare l’uso di un nuovo sistema di navigazione computerizzato-assistito per la valutazione cinematica durante la ricostruzione del LCCr nel cane, ma soprattutto di studiare e confrontare il comportamento e l’efficacia dopo ricostruzione TightRope (TR) in due diverse coppie di punti isometrici. Abbiamo effettuato due analisi in parallelo. La prima eseguendo interventi chirurgici con tecnica TR su 18 casi clinici e sfruttando il punto isometrico del femore (F2) e due diversi punti isometrici della tibia (T2 o T3). L’analisi prevedeva dei controlli postoperatori a 1, 3 e 6 mesi. Ad ogni controllo veniva effettuata una visita ortopedica, esami radiografici, un questionario di valutazione clinico e di soddisfazione del proprietario. Mentre nella ricerca Ex-Vivo abbiamo eseguito dei test su 14 preparati anatomici con l’utilizzo di un sistema di navigazione computerizzato per la rilevazione dei dati. L’analisi prevedeva la valutazione dell’articolazione in diversi stadi: LCCr intatto; LCCr rotto; dopo ricostruzione con TR in F2-T2 e tensionato a 22N, 44N e 99N; dopo ricostruzione con TR in F2-T3 e tensionato a 22N, 44N e 99N. Ad ogni stadio si eseguivano cinque test di valutazione, tra cui: Test del Cassetto, Test di compressione tibiale (TCT), Rotazione Interna/Esterna, Flesso/Estensione e Varo/Valgo. Lo scopo di tale studio è quello di confrontare tra loro i punti isometrici del ginocchio e di analizzare l’efficacia della tecnica TR nelle due differenti condizioni di isometria (F2-T2 e F2-T3).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Restoring a correct implant kinematics and providing a good ligament balance and patellar tracking is mandatory to improve clinical and functional outcome after a Total Knee Replacement. Surgical navigation systems are a reliable and accurate tool to help the surgeon in achieving these goals. The aim of the present study was to use navigation system with an intra-operative surgical protocol to evaluate and determine an optimal implant kinematics during a Total Knee Replacement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Einleitung und Literaturdiskussion: Gentamicin ist ein aus Bakterien gewonnenes Aminoglykosid-Antibiotikum, das seit vielen Jahren im klinischen Alltag zur Therapie von bakteriellen Infektionen und zur Behandlung des Morbus Ménière eingesetzt wird. Ein bedeutender, jedoch noch nicht vollständig verstandener, Pathomechanismus ist dabei die Entstehung von 4-HNE durch Lipid Peroxidation und die konsekutive Schädigung durch das gebildete Aldehyd. Ziel dieser Arbeit war es, die Beeinflussung der Expression von 4-HNE in sieben verschiedenen Regionen der Kochlea (SV, SL, CO, NF, LF, IDZ und SGZ) durch Gentamicin zu beschreiben und quantitativ zu ermitteln.rnMaterial und Methoden: Die Meerschweinchen wurden in vier Gruppen unterteilt: eine unbehandelte Kontrollgruppe und je eine Gruppe 1, 2 und 7 Tage nach Gentamicin-Applikation. Nach Ablauf der Inkubationszeit wurden die Kochleae den Tieren entnommen, das Gewebe fixiert, geschnitten und auf Objektträgern aufgebracht. Die Schnitte wurden mit 4-HNE-Antikörpern behandelt und die Immunreaktion mikroskopisch lokalisiert und zelluläre quantitative Unterschiede am Computer berechnet.rnErgebnisse: Die Auswertung der Daten ergab signifikante Anstiege der Immunreaktion auf 4-HNE von der Kontrollgruppe zu allen drei Behandlungsgruppen in vier der sieben untersuchten Regionen (Stria vascularis, Spirales Ligament, Cortisches Organ und Nervenfasern). In zwei Bereichen (Fibrozyten im Limbus und Interdentalzellen) kam es zwischen Kontrollgruppe und nur einer Behandlungsgruppe D (7d) zu einer signifikanten Erhöhung. Lediglich die Spiralganglionzellen erbrachten keine signifikanten Differenzen. Der Vergleich der Einzelwindungen erbrachte für die Stria vascularis, das Spirale Ligament, das Cortische Organ und die Nervenfasern signifikante Anstiege innerhalb der drei Windungen von der Kontrollgruppe zu den drei Behandlungsgruppen. Bei der Stria vascularis zeigte sich als einzige Region eine signifikant erhöhte Immunfärbung in allen drei Einzelwindungen von der Kontrollgruppe zu allen Behandlungsgruppen. Beim Vergleich der Gesamtwindungen ließ sich ausschließlich für die Region der Stria vascularis von der ersten zur dritten Windung ein Anstieg der Braunfärbung feststellen. Zudem konnten Korrelationen der Färbeintensitäten einerseits zwischen den beiden Regionen der Lateralen Wand und andererseits zwischen zwei Zelltypen im Limbus aufgezeigt werden.rnDiskussion: Die durch Gentamicin-gesteigerte 4-HNE-Expression kann durch genomische und nicht-genomische Prozesse hervorgerufen werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A classification of injuries is necessary in order to develop a common language for treatment indications and outcomes. Several classification systems have been proposed, the most frequently used is the Denis classification. The problem of this classification system is that it is based on an assumption, which is anatomically unidentifiable: the so-called middle column. For this reason, few years ago, a group of spine surgeons has developed a new classification system, which is based on the severity of the injury. The severity is defined by the pathomorphological findings, the prognosis in terms of healing and potential of neurological damage. This classification is based on three major groups: A = isolated anterior column injuries by axial compression, B = disruption of the posterior ligament complex by distraction posteriorly, and group C = corresponding to group B but with rotation. There is an increasing severity from A to C, and within each group, the severity usually increases within the subgroups from .1, .2, .3. All these pathomorphologies are supported by a mechanism of injury, which is responsible for the extent of the injury. The type of injury with its groups and subgroups is able to suggest the treatment modality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The aim of the study is to clinically and histologically evaluate the healing of advanced intrabony defects treated with open flap debridement and the adjunct implantation of granular beta tricalcium phosphate (beta-TCP). METHODS: Five patients, each displaying advanced combined 1- and 2-wall intrabony defects around teeth scheduled for extraction or root resection, were recruited. Approximately 6 months after surgery, the teeth or roots were removed together with a portion of their surrounding soft and hard tissues and processed for histologic evaluation. RESULTS: The mean probing depth (PD) was reduced from 10.8 +/- 2.3 mm presurgically to 4.6 +/- 2.1 mm, whereas a mean clinical attachment level (CAL) gain of 5.0 +/- 0.7 mm was observed. The increase in gingival recession was 1.2 +/- 3.2 mm. The histologic evaluation indicated the formation of new cellular cementum with inserting collagen fibers to a varying extent (mean: 1.9 +/- 0.7 mm; range: 1.2 to 3.03 mm) coronal to the most apical extent of the root instrumentation. The mean new bone formation was 1.0 +/- 0.7 mm (range: 0.0 to 1.9 mm). In most specimens, beta-TCP particles were embedded in the connective tissue, whereas the formation of a mineralized bone-like or cementum-like tissue around the particles was only occasionally observed. CONCLUSION: The present data indicates that treatment of intrabony periodontal defects with this beta-TCP may result in substantial clinical improvements such as PD reduction and CAL gain, but this beta-TCP does not seem to enhance the regeneration of cementum, periodontal ligament, and bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Isolated lateral malleolar fractures usually result from a supination-external rotation (SER) injury and may include a deltoid ligament rupture. The necessity of operative treatment is based on the recognition of a relevant medial soft-tissue disruption. Currently used tests to assess ankle stability include manual stress radiographs and gravity stress radiographs, but seem to overestimate the need for fracture fixation.