982 resultados para fluorescence probe technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Química e Bioquímica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation to obtain a Master degree in Biotechnology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Confocal scanning fluorescence microscopy has become widely used in cell biology and pathology. In conjunction with monoclonal antibodies it may turn out to be a powerful diagnostic tool that also enables detailed studies of tissue forms of Trypanosoma cruzi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Campylobacter was isolated in 178 out of 622 stool samples (200 porcine, 220 bovine, and 202 canine). From these 178 samples, the microorganism was identified in 64 samples (36%) isolated only in Butzler selective medium (BSM), 34 samples (19%) using filtration technique (FT), and in 80 samples (45%) using both BSM and FT. Comparison of the proportion of positivity using both techniques showed a significant value (c2 = 9,184; p > 0.001); BSM (36%) being more efficient than FT (19%). The use of both techniques yielded the highest isolation positivity (45%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thirteen strains of the genus Candida were isolated from catheter, urine and surgical wounds from individual patients of the Santa Casa de Misericórdia, Belo Horizonte, MG, Brazil. Ten strains were characterized as Candida albicans, two as Candida glabrata, and one as Candida parapsilosis. Isolates were evaluated for molecular relatedness by random amplified polymorphic DNA technique using 15 primers. The analysis of the genomic DNA obtained revealed a low intraspecific polymorphism and did not allow for the differentiation between strains of the same species obtained from distinct clinical sources (catheter, urine and surgical wounds). The RAPD profiles generated were able to differentiate among the species of Candida albicans, Candida parapsilosis and Candida glabrata strains isolated in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Química e Bioquímica, Especialidade em Engenharia Bioquímica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação para a Ciência e a Tecnologia (FCT) - PhD grant (SFRH/BD/62568/2009)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Studies strongly indicate Dientamoeba fragilis as one of the causes of diarrhea in human immunodeficiency virus (HIV) patients. METHODS: The objective of the present study was to evaluate the prevalence of D. fragilis associated with the causes of diarrhea in 82 HIV/ AIDS patients hospitalized at the Instituto de Infectologia Emílio Ribas from September 2006 to November 2008. RESULTS: In total, 105 samples were collected from 82 patients. Unprotected sex was the most frequent cause of HIV infection (46.3%), followed by the use of injectable or non-injectable drugs (14.6%). Patients presented with viral loads of 49-750,000 copies/ mL (average: 73,849 ± 124,850 copies/mL) and CD4 counts ranging of 2-1,306 cells/mm³ (average: 159 ± 250 cells/mm³). On an average, the odds of obtaining a positive result by using the other techniques (Hoffman, Pons and Janer or Lutz; Ritchie) were 2.7 times higher than the chance of obtaining a positive result by using the simplified iron hematoxylin method. Significant differences were found between the methods (p = 0.003). CONCLUSIONS: The other techniques can detect a significantly greater amount of parasites than the simplified iron hematoxylin method, especially with respect to Isospora belli, Cryptosporidium sp., Schistosoma mansoni, and Strongyloides stercoralis, which were not detected using hematoxylin. Endolimax nana and D. fragilis were detected more frequently on using hematoxylin, and the only parasite not found by the other methods was D. fragilis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study evaluated the performance of an in-house nested-PCR system for the detection of the Mycobacterium tuberculosis complex in pleural fluid, blood and urine samples from pleural effusion tuberculosis patients by health services physicians in Pernambuco, Brazil. Methods A prospective double-blind study with 37 hospitalized patients of both sexes, aged over 15, was used to investigate the diagnosis of pleural effusion. The criteria used to define the cases included the demonstration of bacillus in biological samples by smear or culture or by a granulomatous finding in the histopathological examination, associated with an evident response to specific treatments to each clinical situation. Pleural fluid, blood and urine samples were collected and subjected to routine tests and the nested PCR technique to assess for M. tuberculosis amplification. Results In total, 37 pleural effusion patients took part in the study, of whom 19 (51.3%) had tubercular etiologies and 18 (48.7%) had etiologies from other causes. When the pleural fluid, blood and/or urine sample in-house nested-PCR sensitivities were evaluated simultaneously, the results were positive regardless of the biological specimen (the sensitivity was 84.2%); however, when the blood and/or urine samples were analyzed together, the sensitivity was 72.2%. When the pleural fluid samples were evaluated alone, the sensitivity was only 33.3%. Conclusions The performance of the diagnostic pleural tuberculosis nested-PCR was directly related to the diversity of the samples collected from the same patient. Additionally, this study may identify a need to prioritize non-invasive blood and urine collection for this diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present article is based on the MA thesis of Hou Bowen (Ph.D candidate) and on the presentation made at the ISA World Congress of Sociology held in Yokohama (Japan) on July 2014 at the Session on “Assessing Technologies: Global Patterns of Trust and Distrust” of RC23-Sociology of Science and Technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors analysed a series of 22 patients undergoing surgical correction of congenital hand syndactyly by the rectangular flap technique. Using our evaluation method, we found that good functional and aesthetic results were obtained in 77.3% of the patients, with a complication rate of 13.6%. We concluded that the rectangular flap technique has a simple design, is easily reproducible by in-training staff, has good results, and can be applied on the majority of the syndactyly cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fully comprehending brain function, as the scale of neural networks, will only be possi-ble with the development of tools by micro and nanofabrication. Regarding specifically silicon microelectrodes arrays, a significant improvement in long-term performance of these implants is essential. This project aims to create a silicon microelectrode coating that provides high-quality electrical recordings, while limiting the inflammatory response of chronic implants. To this purpose, a combined chitosan and gold nanoparticles coating was produced allied with electrodes modification by electrodeposition with PEDOT/PSS in order to reduce the im-pedance at 1kHz. Using a dip-coating mechanism, the silicon probe was coated and then charac-terized both morphologically and electrochemically, with focus on the stability of post-surgery performance in anesthetized rodents. Since not only the inflammatory response analysis is vital, the electrodes recording degradation over time was also studied. The produced film presented a thickness of approximately 50 μm that led to an increase of impedance of less than 20 kΩ in average. On a 3 week chronic implant, the impedance in-crease on the coated probe was of 641 kΩ, compared with 2.4 MΩ obtained for the uncoated probe. The inflammatory response was also significantly reduced due to the biocompatible film as proved by histological tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prospective study was conducted to determine if standardized vancomycin doses could produce adequate serum concentrations in 25 term newborn infants with sepsis. Purpose: The therapeutic response of neonatal sepsis by Staphylococcus sp. treated with vancomycin was evaluated through serum concentrations of vancomycin, serum bactericidal titers (SBT), and minimum inhibitory concentration (MIC). METHOD: Vancomycin serum concentrations were determined by the fluorescence polarization immunoassay technique , SBT by the macro-broth dilution method, and MIC by diffusion test in agar . RESULTS: Thirteen newborn infants (59.1%) had adequate peak vancomycin serum concentrations (20--40 mg/mL) and one had peak concentration with potential ototoxicity risk (>40 µg/mL). Only 48% had adequate trough concentrations (5--10 mg/mL), and seven (28%) had a potential nephrotoxicity risk (>10 µg/mL). There was no significant agreement regarding normality for peak and trough vancomycin method (McNemar test : p = 0.7905). Peak serum vancomycin concentrations were compared with the clinical evaluation (good or bad clinical evolution) of the infants, with no significant difference found (U=51.5; p=0.1947). There was also no significant difference between the patients' trough concentrations and good or bad clinical evolution (U = 77.0; p=0.1710). All Staphylococcus isolates were sensitive to vancomycin according to the MIC. Half of the patients with adequate trough SBT (1/8), also had adequate trough vancomycin concentrations and satisfactory clinical evolution. CONCLUSIONS: Recommended vancomycin schedules for term newborn infants with neonatal sepsis should be based on the weight and postconceptual age only to start antimicrobial therapy. There is no ideal pattern of vancomycin dosing; vancomycin dosages must be individualized. SBT interpretation should be made in conjunction with the patient's clinical presentation and vancomycin serum concentrations. Those laboratory and clinical data favor elucidation of the probable cause of patient's bad evolution, which would facilitate drug adjustment and reduce the risk of toxicity or failing to achieve therapeutic doses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE: To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS: Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS: The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION: There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.