Low voltage solar panels increase the reliability of solar panels due to reduction of in series associations the configurations of photovoltaic cells. The low voltage generation requires DCDC converters devices with high efficiency, enabling raise and regulate the output voltage. This study analyzes the performance of a photovoltaic panel of Solarex, MSX model 77, configured to generate an open circuit voltage of 10.5 V, with load voltage of 8.5 V, with short circuit current of 9 A and a power of 77 W. The solar panel was assembled in the isolated photovoltaic system configuration, with and without energy storage as an interface with a DCDC converter, Booster topology. The converter was designed and fabricated using SMD (Surface Mounted Devices) technology IC (integrated circuit) that regulates its output voltage at 14.2 V, with an efficiency of 87% and providing the load a maximum power of 20.88 W. The system was installed and instrumented for measurement and acquisition of the following data: luminosities, average global radiation (data of INPE Instituto Nacional de Pesquisas Espaciais), solar panel and environment temperatures, solar panel and DC-DC converter output voltages, panel, inverter, and battery charge output currents. The photovoltaic system was initially tested in the laboratory (simulating its functioning in ideal conditions of operation) and then subjected to testing in real field conditions. The panel inclination angle was set at 5.5°, consistent with the latitude of Natal city. Factors such as climatic conditions (simultaneous variations of temperature, solar luminosities and ra diation on the panel), values of load resistance, lower limit of the maximum power required by the load (20.88 W) were predominant factors that panel does not operate with energy efficiency levels greater than 5 to 6%. The average converter efficiency designed in the field test reached 95%

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wood gasification technologies to convert the biomass into fuel gas stand out. on the other hand, producing electrical energy from stationary engine is widely spread, and its application in rural communities where the electrical network doesn't exist is very required. The recovery of exhaust gases (engine) is a possibility that makes the system attractive when compared with the same components used to obtain individual heat such as electric power. This paper presents an energetic alternative to adapt a fixed bed gasifier with a compact cogeneration system in order to cover electrical and thermal demands in a rural area and showing an energy solution for small social communities using renewable fuels. Therefore, an energetic and economical analysis from a cogeneration system producing electric energy, hot and cold water, using wooden gas as fuel from a small-sized gasifier was calculated. The energy balance that includes the energy efficiency (electric generation as well as hot and cold water system; performance coefficient and the heat exchanger, among other items), was calculated. Considering the annual interest rates and the amortization periods, the costs of production of electrical energy, hot and cold water were calculated, taking into account the investment, the operation and the maintenance cost of the equipments. Crown Copyright (C) 2010 Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivou-se avaliar, por meio do desempenho animal, silagens de três híbridos de milho (Zea mays, L.): Agroceres AG-5011, Braskalb XL-344 e Cargill C-806. Foram utilizados 27 machos, não-castrados, mestiços Nelore x Charolês, com idade média de 10 meses e peso médio inicial de 252 kg, confinados durante 84 dias, subdivididos em quatro períodos de 21 dias. As silagens dos híbridos testados corresponderam a 70% da matéria seca ofertada. Não houve interação do híbrido de milho testado com o período de avaliação em confinamento, para os parâmetros estudados. A dieta que incluiu a silagem do híbrido AG-5011 resultou em maior consumo voluntário médio diário de matéria seca, expresso por 100 kg de peso vivo e tamanho metabólico, e maior consumo médio diário de fibra em detergente ácido, expresso nas diferentes formas, em relação aos híbridos XL-344 e C-806, que, por sua vez, foram semelhantes entre si. As dietas que incluíram silagens dos híbridos AG-5011, XL-344 e C-806 apresentaram semelhanças quanto ao consumo voluntário de matéria seca, expresso em kg/animal/dia (6,73; 6,05; e 6,19), consumo médio diário de FDN, em kg/dia (3,054; 2,837; e 2,836), e energia digestível, expressa nas diferentes formas, ganho de peso médio diário, em kg/dia (1,283; 1,219; e 1,249), ganho em estado corporal, conversão alimentar (5,26; 4,98; e 4,97) e eficiência energética (14,02; 13,68; e 13,21). Os três híbridos são indicados como materiais genéticos de muito boa qualidade para produção de silagem, promovendo ganhos de peso diário superior a 1,2 kg/animal/dia, quando utilizados em dietas com relação volumoso:concentrado de 70:30.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An experiment with 400 laying hens Hy Line with 26 weeks of age was conducted to compare the performance of laying hens fed during four cycles of 28 days with diets containing soybean meal (SM) plus soybean oil (SBM+oil), whole extruded soybean (ESB) and whole steam toasted soybean (TSB). A completely design randomized blocks was used, with 10 treatments and five replicates and eight laying hens in each experimental unit. The treatments consisted on the replacement of SBM per ESB and TSB at the levels 0, 25, 50, 75 and 100%; and as control the SBM with or without addition of oil. The results obtained showed that the hens were able to regulate the feed intake to maintain the energy intake only at lower energetic levels, however they tended to over intake energy with the increase of energy levels of the diets. The addition of oil or soybeans in the diets improved feed: gain ratio, however worsened the energy efficiency in relation to the diet without oil. The processing of soybean provided differences on the performance of laying hens and the ESB showed to be superior to TSB. The hens had higher use of the oil added to the soybean meal (SBM + oil) and ESB in relation to TSB. However, the values of AMEn obtained for the ESB were 12% higher, in average, to those determined for the SBM + oil and for the TSB.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The efficiency of energy transfer (ET) between Pr3+ ions in a fluoroindate glass is determined. ET rates, WET, were determined for dilute samples and the results show a dependence of WET on the Pr3+ concentration. ET processes which contribute to resonance fluorescence and frequency upconversion emission were studied. The origin of the interaction energy among the Pr3+ ions was determined to be dipole - dipole. © 1998 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It was evaluated the energetic efficiency and operational parameters of a windrowing and prismatic baling, both from CASE NEW HOLLAND® operations in sugarcane vegetal residues (green leaves, dry leaves and tops) picked mechanically in green cane. The area belongs to COSTA PINTO MILL (COSAN® Group) which was harvested mechanically by combines in the State of Sao Paulo, Brazil. The geographic location of the area is: Latitude 22°40'30S, Longitude 47°36'38W and Altitude of 605m. The variety was RB 82-5336, planted in 1.40m row spacing, with 78t.ha-1 yield. The vegetal residues analysis obtained 69.93% of leaves, 21.44% of stalks fractions, 2.27% of tops and 6.36% of total strange matter. The vegetal residues values were: gross heat of 18.43MJ.kg-1, low heat of 17.00MJ.kg'1 and useful heat of 12.94MJ.kg-1. The vegetal residues average energetic potential was 342.48GJ.ha-1. The treatments were simple, double and triple windrowing. The use of the rake and prismatic baler to pick up the residues was viable. The simple windrowing treatment presented the best results: effective capacity of 83.06t.ha-1, fuel consumption of 0.18L.t -1 and 99.95% of positive energetic efficiency. The bales obtained in the treatment of triple windrowing presented the largest specific mass average of 221.11kg.m-3. The soil amount in the bales increased with successive windrowing. The baling operation in the triple windrowing treatment obtained better results, presenting the effective capacities of 20.29t.h -1 and 1.45ha.h-1 and fuel consumption of for baled in 1.37L.t-1. The high total energetic efficiency of 99.53% indicates that is technically viable the withdrawal of the vegetal residues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to analyze the sugar cane vegetal residues collection, as well as determining its energetic potential, using a rake and cylindrical baler, both from NEW HOLLAND® under two different windrowing process (simple and double). The field tests were carried out in an area that belongs to COSTA PINTO MILL (COSAN® Group) in the city of Piracicaba, Sao Paulo State, Brazil. The geographic location of the area is: Latitude 22°4030'S, Longitude 47°3633'W and altitude of 605m. From the trash analysis, before the baling, the following average results were obtained: 69.93% of leaves; 2.27% of stalks fractions; 21.44% of tops and 6.36% of total strange matter. The estimated residues yield was 27.01 tons.ha -1 with a gross heat of 18.43 MJ.kg-1, low heat of 17.01 MJ.kg-1, useful heat of 13.32 MJ.kg-1, average moisture of 20.76% and an energetic potential of 494,875.09 MJ.ha-1. In the windrowing operations (simple and double) the averages of the 5 out of 13 analyzed variable presented differences between them in a 1% level of significance in the Tukey Test. The averages comparison of the results for bale's specific mass and the effective capacities (ton.h-1) e (ha.h-1) had been significant at a 5% level in the Tukey Test. The comparisons of the averages for the results had been significant to 1% level. The strange matter averages of the bales did not differed between them.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sugar cane crop according to several authors can generate, besides the industrialized stalks, an amount of crop residues from the order of 15 to 30% in weight of the aerial part of the plants, depending on the field conditions. The sugar cane area in Brazil is around 5.5×106 hectares, with an amount of 400.106 tons of stalks, with stalks yield of 72 tons.ha-1 (Unica, 2005). This study took place in a sugar cane plot (Latitude 22°46'S, Longitude 47°23'W and 600m of altitude) with 3% of slope, located in São Paulo State. The sugar cane variety was SP 80-1816, in its forth cut, 11 months old and with a planted row spacing of 1.40m. By other side, several sugar mills are bringing the crop residue to their patio to produce energy with the bagasse. One way for that is the baling operation to bring the crop residue at the sugar mill. Some fundamental variables were obtained to define the best set of machines to work with in sugar cane crop residue removal in the baling system among the studied ones, some of the variables were: Soil Index (T1 = 0.83%, T2 = 0.46%, T3 = 0.65%, T4 = 0.57%); Energy Efficiency (T1 = 82.48%, T2 = 83.88%, T3 = 82.83% and T4 = 82.97%) of the system and Effective Cost for Equivalent Energy in US$.EBP-1 (T1 = 11.10, T2= 10.46, T3 = 11.47 and T4 = 10.57) of the baled trash delivered at the sugar mill.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc flash hazard is a particularly new phenomenon and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be increased, simply by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as non-standard practices and installations are also partly responsible. The aim of this study is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc flash interruption performance of various manufacturers. The purpose of this study is to obtain a more objective indication of the influence of different fuse link manufacturers on arc flash incident energy. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc-flash hazard is a particularly new phenomenon, and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be simply increased by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as nonstandard practices and installations are also partly responsible. The aim of this article is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc-flash interruption performance of various manufacturers. The purpose of this article is to obtain a more objective indication of the influence of different fuse link manufacturers on arc-flash incident energy. © 1975-2012 IEEE.