920 resultados para cemented hip
Resumo:
Considering different perspectives, the scope of this thesis is to investigate how to improve healthcare resources allocation and the provision efficiency for hip surgeries, a resource-intensive operation, among the most frequently performed on the elderly, with a trend in volume that is increasing in years due to population aging. Firstly, the effect of Time-To-Surgery (TTS) on mortality for hip fracture patients is investigated. The analysis attempts to account for TTS endogeneity due to the inability to fully control for variables affecting patient delay – e.g. patient severity. Exploiting an instrumental variable model, where being admitted on Friday or Saturday predicts longer TTS, findings show exogenous TTS does not have a significant effect on mortality. Thus suggesting surgeons prioritize patients effectively, neutralizing the adverse impact of longer TTS. Then, the volume-outcome relation for total hip replacement surgery is analyzed, seeking to account for selective referral, which may be present in elective surgery context, and induce reverse causality issue in the volume-outcome relation. The analysis employs a conditional choice model where patient travel distance from all regions' hospitals is used as a hospital choice predictor. Findings show the exogenous hospital volume significantly decreases adverse outcomes probability, especially in the short run. Finally, the change in public procurement design enforced in the Romagna LHA (Italy) is exploited to assess its impact on hip prostheses cost, surgeons' implant choice, and patient health outcomes. Hip prostheses are the major cost-driver of hip replacement surgeries, hence it is crucial to design the public tender such that implant prices are minimized, but cost-containment policies have to be weighted with patient well-being. Evidence shows that a cost reduction occurred without a significant surgeons’ choices impact. Positive or no effect of surgeons specialization is found on patients outcomes after the new procurement introduction.
Resumo:
Total hip and knee replacements (THR/TKR) are considered the gold standard surgical treatments for end-stage osteoarthritis (OA), effectively alleviating pain, enhancing joint mobility and quality of life (QoL). Maintaining an active lifestyle and regular physical activity (PA) is crucial for these patients, as it can increase bone density and stability of joint prosthesis. This thesis aims to: (1) systematically review recommendations from healthcare professionals; (2) explore interventions promoting an active lifestyle post-THR and TKR; (3) investigate the primary causes of stiffness post-TKR; (4) design an exercise protocol to enhance QoL post-THR and TKR; (5) evaluate orthopedic surgeons' attitudes toward PA for patients post-THR/TKR; and (6) assess changes in QoL after a specifically designed PA intervention. The initial review revealed consensus on permissible sports activities post-surgery, but few studies addressed interventions targeting PA behaviors. Subsequently, findings highlighted key factors contributing to post-TKR stiffness, including mispositioned components, psychological distress, and obesity. Building on these insights, a PA intervention was implemented, followed by a survey investigating orthopedic surgeons' attitudes towards PA, which demonstrated a general positive attitude. Lastly, a pilot randomized controlled trial demonstrated significant enhancements in QoL, physical function, and clinical outcomes following a three-month adapted PA intervention. Future research should focus on raising awareness among individuals and healthcare professionals, fostering engagement in PA programs, and promoting active lifestyles. PA represents a valuable strategy for mitigating the burden of chronic diseases on society.
Resumo:
Radiation dose in x-ray computed tomography (CT) has become a topic of great interest due to the increasing number of CT examinations performed worldwide. In fact, CT scans are responsible of significant doses delivered to the patients, much larger than the doses due to the most common radiographic procedures. This thesis work, carried out at the Laboratory of Medical Technology (LTM) of the Rizzoli Orthopaedic Institute (IOR, Bologna), focuses on two primary objectives: the dosimetric characterization of the tomograph present at the IOR and the optimization of the clinical protocol for hip arthroplasty. In particular, after having verified the reliability of the dose estimates provided by the system, we compared the estimates of the doses delivered to 10 patients undergoing CT examination for the pre-operative planning of hip replacement with the Diagnostic Reference Level (DRL) for an osseous pelvis examination. Out of 10 patients considered, only for 3 of them the doses were lower than the DRL. Therefore, the necessity to optimize the clinical protocol emerged. This optimization was investigated using a human femur from a cadaver. Quantitative analysis and comparison of 3D reconstructions were made, after having performed manual segmentation of the femur from different CT acquisitions. Dosimetric simulations of the CT acquisitions on the femur were also made and associated to the accuracy of the 3D reconstructions, to analyse the optimal combination of CT acquisition parameters. The study showed that protocol optimization both in terms of Hausdorff distance and in terms of effective dose (ED) to the patient may be realized simply by modifying the value of the pitch in the protocol, by choosing between 0.98 and 1.37.
Resumo:
Although various abutment connections and materials have recently been introduced, insufficient data exist regarding the effect of stress distribution on their mechanical performance. The purpose of this study was to investigate the effect of different abutment materials and platform connections on stress distribution in single anterior implant-supported restorations with the finite element method. Nine experimental groups were modeled from the combination of 3 platform connections (external hexagon, internal hexagon, and Morse tapered) and 3 abutment materials (titanium, zirconia, and hybrid) as follows: external hexagon-titanium, external hexagon-zirconia, external hexagon-hybrid, internal hexagon-titanium, internal hexagon-zirconia, internal hexagon-hybrid, Morse tapered-titanium, Morse tapered-zirconia, and Morse tapered-hybrid. Finite element models consisted of a 4×13-mm implant, anatomic abutment, and lithium disilicate central incisor crown cemented over the abutment. The 49 N occlusal loading was applied in 6 steps to simulate the incisal guidance. Equivalent von Mises stress (σvM) was used for both the qualitative and quantitative evaluation of the implant and abutment in all the groups and the maximum (σmax) and minimum (σmin) principal stresses for the numerical comparison of the zirconia parts. The highest abutment σvM occurred in the Morse-tapered groups and the lowest in the external hexagon-hybrid, internal hexagon-titanium, and internal hexagon-hybrid groups. The σmax and σmin values were lower in the hybrid groups than in the zirconia groups. The stress distribution concentrated in the abutment-implant interface in all the groups, regardless of the platform connection or abutment material. The platform connection influenced the stress on abutments more than the abutment material. The stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections.
Resumo:
To assess the effects of a soy dietary supplement on the main biomarkers of cardiovascular health in postmenopausal women compared with the effects of low-dose hormone therapy (HT) and placebo. Double-blind, randomized and controlled intention-to-treat trial. Sixty healthy postmenopausal women, aged 40-60 years, 4.1 years mean time since menopause were recruited and randomly assigned to 3 groups: a soy dietary supplement group (isoflavone 90mg), a low-dose HT group (estradiol 1 mg plus noretisterone 0.5 mg) and a placebo group. Lipid profile, glucose level, body mass index, blood pressure and abdominal/hip ratio were evaluated in all the participants at baseline and after 16 weeks. Statistical analyses were performed using the χ2 test, Fisher's exact test, Kruskal-Wallis non-parametric test, analysis of variance (ANOVA), paired Student's t-test and Wilcoxon test. After a 16-week intervention period, total cholesterol decreased 11.3% and LDL-cholesterol decreased 18.6% in the HT group, but both did not change in the soy dietary supplement and placebo groups. Values for triglycerides, HDL-cholesterol, glucose level, body mass index, blood pressure and abdominal/hip ratio did not change over time in any of the three groups. The use of dietary soy supplement did not show any significant favorable effect on cardiovascular health biomarkers compared with HT. The trial is registered at the Brazilian Clinical Trials Registry (Registro Brasileiro de Ensaios Clínicos - ReBEC), number RBR-76mm75.
Resumo:
Objective To assess the prevalence of insulin resistance (IR) and associated factors in contraceptive users. Methods A total of 47 women 18 to 40 years of age with a body mass index (kg/m(2)) < 30, fasting glucose levels < 100 mg/dl and 2-hour glucose level < 140 mg/dl after a 75-g oral glucose load were submitted to a hyperinsulinemic-euglycemic clamp. The women were distributed in tertiles regarding M-values. The analysed variables were use of combined hormonal/non-hormonal contraception, duration of use, body composition, lipid profile, glucose levels and blood pressure. Results IR was detected in 19% of the participants. The women with low M-values presented significantly higher body fat mass, waist-to-hip ratio, fasting insulin, HOMA-IR and were nulligravida, showed > 1 year of contraceptive use and higher triglyceride levels. IR was more frequent among combined oral contraceptive users, however no association was observed after regression analysis. Conclusions The prevalence of IR was high among healthy women attending a family planning clinic independent of the contraceptive method used with possible long-term negative consequences regarding their metabolic and cardiovascular health. Although an association between hormonal contraception and IR could not be found this needs further research. Family planning professionals should be proactive counselling healthy women about the importance of healthy habits.
Resumo:
OBJECTIVE: Evaluate the impact that trochanteric hip fractures produce on life quality of elderly patients, treated surgically, during one year of monitoring. METHODS: Were selected 73 elderly with transtrochanteric femur fracture, aged equal or over than 65 years and of both sexes. All participants underwent a standardized questionnaire which obtained information on lifestyle habits, functionality, physical activity, ambulation and cognitive state. Were excluded patients who died, not walking, with neurological diseases and pathological fractures. RESULTS: The average age was 80.17 ± 7.2 years and 75% was female. When comparing the summation of activities of daily living (p = 0.04) and instrumental daily living (p = 0.004) obtained before and after fracture, the patients become more dependent after fracture. Activities of daily living that worsened after fracture were bathing (p = 0.04), toileting (p = 0.02) and dressing (p = 0.04). All instrumental activities of daily living showed a significant difference, with functional dependence after fracture, increased need for walking aid (p = 0.00002), aged (p = 0.01) and not doing housework (p = 0.01). The low score on the test Minimental was associated with a greater dependence to perform activities of daily living before (p = 0.00002) and after (p = 0.01) fracture. CONCLUSION: After a year, activities of daily living that depended on the lower limbs worsened significantly, all instrumental activities of daily living were significantly worse in more than 50% of patients and more than half of patients who walked without support lost this ability.
Resumo:
The MINUS system was developed as a minimally invasive procedure that uses a diaphyseal cephalic extramedullary implant for the treatment of transtrochanteral fractures of the femur in elderly patients. The implant consists of a sliding screw coupled to a plate adapted to the minimally invasive technique. The surgical access is approximately three centimeters in length located on the lateral surface of the hip, below the projection of the small trochanter. A perfectly adapted instrument was used for the procedure, which also requires the use of an image intensifier, reducing surgery time and rate of bleeding. The objective of this study is to present a new instrument and implant, developed specifically for treatment with the minimally invasive technique, reducing the length of the conventional surgical access from 10 to three centimetres. This new implant was given the commercial name of MINUS System.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física