995 resultados para absorption measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Administration of chloromycetin has been found to enhance the oxygen uptake of the gut of the silkworm. The possibility that this increase might have been due to a thinning of the gut wall has been ruled out since the reduction in gut weight set in much later. Although glucose ultilization by the gut has been found to be increased in vitro, increase in oxygen uptake has not been affected in the presence of glucose. The possibility of a hormonal stimulation has been discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Administration of chloromycetin has been found to enhance the oxygen uptake of the gut of the silkworm. The possibility that this increase might have been due to a thinning of the gut wall has been ruled out since the reduction in gut weight set in much later. Although glucose ultilization by the gut has been found to be increased in vitro, increase in oxygen uptake has not been affected in the presence of glucose. The possibility of a hormonal stimulation has been discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using the bender and extender elements tests, the travel times of the shear (S) and the primary (P) waves were measured for dry sand samples at different relative densities and effective confining pressures. Three methods of interpretations, namely, (i) the first time of arrival, (ii) the first peak to peak, and (iii) the cross-correlation method, were employed. All the methods provide almost a unique answer associated with the P-wave measurements. On contrary, a difference was noted in the arrival times obtained from the different methods for the S-wave due to the near field effect. The resonant column tests in the torsional mode were also performed to check indirectly the travel time of the shear wave. The study reveals that as compared to the S-wave, it is more reliable to depend on the arrival times' measurement for the P-wave. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using the bender and extender elements tests, the travel times of the shear (S) and the primary (P) waves were measured for dry sand samples at different relative densities and effective confining pressures. Three methods of interpretations, namely, (i) the first time of arrival, (ii) the first peak to peak, and (iii) the cross-correlation method, were employed. All the methods provide almost a unique answer associated with the P-wave measurements. On contrary, a difference was noted in the arrival times obtained from the different methods for the S-wave due to the near field effect. The resonant column tests in the torsional mode were also performed to check indirectly the travel time of the shear wave. The study reveals that as compared to the S-wave, it is more reliable to depend on the arrival times’ measurement for the P-wave.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate mass flow measurement is very important in various monitoring and control applications. This paper proposes a novel method of fluid flow measurement by compensating the pressure drop across the ends of measuring unit using a compensating pump. The pressure drop due to the flow is balanced by a feedback control loop. This is a null-deflection type of measurement. As the insertion of such a measuring unit does not affect the functioning of the systems, this is also a non-disruptive flow measurement method. The implementation and design of such a unit are discussed. The system is modeled and simulated using the bond graph technique and it is experimentally validated. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A three-terminal capacitance bridge is developed for the measurement of the dielectric constant of lossy liquids. Using this modified ratio transformer bridge, the capacitance shunted by a resistance as low as 50 Omega is measured at 10 kHz. The capacitance error associated with the inductance of the connecting wire is compensated using the novel method of introducing an additional transformer to the existing ratio transformer bridge. Other sources of capacitance errors, such as the non-zero output impedence of the ratio transformer and the shield capacitances of the cables, are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electronic absorption peak at around 2 eV of polyaniline (in the emeraldine base form) solution is found to be highly sensitive to the dielectric constant of the solvent, showing a bathochromic shift. An increase in electron density on the imine nitrogen of the polymer, on ‘2 eV’ excitation, has been concluded.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present a growing and pruning radial basis function based no-reference (NR) image quality model for JPEG-coded images. The quality of the images are estimated without referring to their original images. The features for predicting the perceived image quality are extracted by considering key human visual sensitivity factors such as edge amplitude, edge length, background activity and background luminance. Image quality estimation involves computation of functional relationship between HVS features and subjective test scores. Here, the problem of quality estimation is transformed to a function approximation problem and solved using GAP-RBF network. GAP-RBF network uses sequential learning algorithm to approximate the functional relationship. The computational complexity and memory requirement are less in GAP-RBF algorithm compared to other batch learning algorithms. Also, the GAP-RBF algorithm finds a compact image quality model and does not require retraining when the new image samples are presented. Experimental results prove that the GAP-RBF image quality model does emulate the mean opinion score (MOS). The subjective test results of the proposed metric are compared with JPEG no-reference image quality index as well as full-reference structural similarity image quality index and it is observed to outperform both.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four algorithms, all variants of Simultaneous Perturbation Stochastic Approximation (SPSA), are proposed. The original one-measurement SPSA uses an estimate of the gradient of objective function L containing an additional bias term not seen in two-measurement SPSA. As a result, the asymptotic covariance matrix of the iterate convergence process has a bias term. We propose a one-measurement algorithm that eliminates this bias, and has asymptotic convergence properties making for easier comparison with the two-measurement SPSA. The algorithm, under certain conditions, outperforms both forms of SPSA with the only overhead being the storage of a single measurement. We also propose a similar algorithm that uses perturbations obtained from normalized Hadamard matrices. The convergence w.p. 1 of both algorithms is established. We extend measurement reuse to design two second-order SPSA algorithms and sketch the convergence analysis. Finally, we present simulation results on an illustrative minimization problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach for measurement of small rotation angles using imaging method is proposed and demonstrated. A plane mirror placed on a precision rotating table is used for imaging the newly designed composite coded pattern. The imaged patterns are captured with the help of a CCD camera. The angular rotation of the plane mirror is determined from a pair of the images of the pattern, captured once before and once after affecting the tilt of the mirror. Both simulation and experimental results suggest that the proposed approach not only retains the advantages of the original imaging method but also contributes significantly to the enhancement of its measuring range (+/- 4.13 degrees with accuracy of the order of 1 arcsec).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aerodynamic forces and fore-body convective surface heat transfer rates over a 60 degrees apex-angle blunt cone have been simultaneously measured at a nominal Mach number of 5.75 in the hypersonic shock tunnel HST2. An aluminum model incorporating a three-component accelerometer-based balance system for measuring the aerodynamic forces and an array of platinum thin-film gauges deposited on thermally insulating backing material flush mounted on the model surface is used for convective surface heat transfer measurement in the investigations. The measured value of the drag coefficient varies by about +/-6% from the theoretically estimated value based on the modified Newtonian theory, while the axi-symmetric Navier-Stokes computations overpredict the drag coefficient by about 9%. The normalized values of measured heat transfer rates at 0 degrees angle of attack are about 11% higher than the theoretically estimated values. The aerodynamic and the heat transfer data presented here are very valuable for the validation of CFD codes used for the numerical computation of How fields around hypersonic vehicles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electronic absorption spectra of a variety of thiocarbonyl and selenocarbonyl compounds have been compared to point out their similarities. Interesting correlations between the absorption maxima and electronegativities of substituents in both the seleno- and thio-carbonyl compounds have been reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray absorption spectra, X-ray photoelectron spectra and Auger spectra of cuprate superconductors are discussed. The studies establish the absence of Cu3+ for all practical purposes, but point out the importance of oxygen holes. X-ray photoelectron spectra of BaBi0.25Pb0.75O3 and related compounds are also examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the results of our non-resonant microwave absorption (NRMA) studies on single crystals of Tl2Ba2CaCu2O8 (Tl 2212) which reflect the occurrence of intrinsic Josephson coupling in these crystals. We have studied the magnetic field induced microwave absorption at various temperatures from 4.2K to T-c (similar to 104K) using a standard CW EPR spectrometer (H-dc parallel to c). We observe the appearance of a characteristic feature in the NRMA signals similar to the ones observed earlier by us in Bi2Sr2CaCu2O8 (Bi 2212) starting a few degrees below T-c, which on cooling passes through a maximum in intensity before disappearing at a further low temperature. This behaviour is attributed to the appearance, strengthening and disappearance of Josephson response consequent to the temperature dependence of the viscosity of the Josephson medium between the CuO2 superconducting sheets.