Non-disruptive and null-deflection mass flow measurement by a pressure compensation technique


Autoria(s): Prasanna, UR; Umanand, L
Data(s)

01/03/2010

Resumo

Accurate mass flow measurement is very important in various monitoring and control applications. This paper proposes a novel method of fluid flow measurement by compensating the pressure drop across the ends of measuring unit using a compensating pump. The pressure drop due to the flow is balanced by a feedback control loop. This is a null-deflection type of measurement. As the insertion of such a measuring unit does not affect the functioning of the systems, this is also a non-disruptive flow measurement method. The implementation and design of such a unit are discussed. The system is modeled and simulated using the bond graph technique and it is experimentally validated. (C) 2009 Elsevier Ltd. All rights reserved.

Formato

application/pdf

Identificador

http://eprints.iisc.ernet.in/28957/1/Mass.pdf

Prasanna, UR and Umanand, L (2010) Non-disruptive and null-deflection mass flow measurement by a pressure compensation technique. In: Flow Measurement and Instrumentation, 21 (1). pp. 54-61.

Publicador

Elsevier Science

Relação

http://dx.doi.org/10.1016/j.flowmeasinst.2009.11.005

http://eprints.iisc.ernet.in/28957/

Palavras-Chave #Electronic Systems Engineering (Formerly, (CEDT) Centre for Electronic Design & Technology)
Tipo

Journal Article

PeerReviewed