962 resultados para Tunnel diodes


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The risks of a public exposure to a sudden decompression, until now, have been related to civil aviation and, at a lesser extent, to diving activities. However, engineers are currently planning the use of low pressure environments for underground transportation. This method has been proposed for the future Swissmetro, a high-speed underground train designed for inter-urban linking in Switzerland. HYPOTHESIS: The use of a low pressure environment in an underground public transportation system must be considered carefully regarding the decompression risks. Indeed, due to the enclosed environment, both decompression kinetics and safety measures may differ from aviation decompression cases. METHOD: A theoretical study of decompression risks has been conducted at an early stage of the Swissmetro project. A three-compartment theoretical model, based on the physics of fluids, has been implemented with flow processing software (Ithink 5.0). Simulations have been conducted in order to analyze "decompression scenarios" for a wide range of parameters, relevant in the context of the Swissmetro main study. RESULTS: Simulation results cover a wide range from slow to explosive decompression, depending on the simulation parameters. Not surprisingly, the leaking orifice area has a tremendous impact on barotraumatic effects, while the tunnel pressure may significantly affect both hypoxic and barotraumatic effects. Calculations have also shown that reducing the free space around the vehicle may mitigate significantly an accidental decompression. CONCLUSION: Numeric simulations are relevant to assess decompression risks in the future Swissmetro system. The decompression model has proven to be useful in assisting both design choices and safety management.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coraebus undatus is the main insect pest of cork oak worldwide. The larvae tunnel in the cortical cambium filling the bark with galleries and causing the cork to break at harvest. The first objective of this study was to test the effect of purple traps in the attraction of C. undatus because this colour is attractive to other buprestid beetles. The second objective was to develop a diet in which field-collected larvae could be reared to adulthood. Pairs of purple and clear (control) sticky traps were placed in a cork oak forest in Girona, Spain in the summer of 2008

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zinc selenide is a prospective material for optoelectronics. The fabrication of ZnSe­based light-emitting diodes is hindered by complexity of p-type doping of the component materials. The interaction between native and impurity defects, the tendency of doping impurity to form associative centres with native defects and the tendency to self-compensation are the main factors impeding effective control of the value and type of conductivity. The thesis is devoted to the study of the processes of interaction between native and impurity defects in zinc selenide. It is established that the Au impurity has the most prominent amphoteric properties in ZnSe among Cu, Ag and Au impurities, as it forms a great number of both Au; donors and Auz„ acceptors. Electrical measurements show that Ag and Au ions introduced into vacant sites of the Zn sublattice form simple single-charged Agz„+ and Auzn+ states with d1° electron configuration, while Cu ions can form both single-charged Cuz„ (d1) and double-charged Cuzr`+ (d`o) centres. Amphoteric properties of Ag and Au transition metals stimulated by time are found for the first time from both electrical and luminescent measurements. A model that explains the changes in electrical and luminescent parameters by displacement of Ag ions into interstitial sites due to lattice deformation forces is proposed. Formation of an Ag;-donor impurity band in ZnSe samples doped with Ag and stored at room temperature is also studied. Thus, the properties of the doped samples are modified due to large lattice relaxation during aging. This fact should be taken into account in optoelectronic applications of doped ZnSe and related compounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Se ha estudiado el papel, como inhibidores de la acción feromonal, de determinados fluoroderivados, análogos estructurales del acetato de (Z)-l 1-hexadecenilo, componente principal de la feromona sexual del noctuido Sesamia nonagrioides Lef. Dichos compuestos fueron los análogos fluoroacetato (mono, di y trifluoroacetato de (Z)-l 1-hexadecenilo) y la trifluorometilcetona análoga [(Z)-1,1,1 -trifluoro-14-nonadecen-2-ona]. La acción inhibidora fue evaluada a partir de los resultados de actividad electrofisiológica (pruebas de electroantenograma, EAG), de estudios de comportamiento en pruebas de túnel de viento y de pruebas de capturas en campo. Los acetatos fluorados, especialmente el mono y el trifluoracetato, se mostraron como buenos inhibidores de la acción atrayente de la feromona en los tres tipos de pruebas realizadas, mientras que la trifluorometilcetona análoga mostró una actividad mucho menor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contexte Lié au vieillissement et à la sédentarisation de la population, ainsi qu'à la chronicisation du cancer, l'emploi de cathéters veineux centraux permanents (CVCP) n'a cessé d'augmenter. La complication majeure de ces dispositifs, induisant de forts taux de morbi-mortalité, est l'infection. Actuellement, le diagnostic de ces infections reste surtout basé sur la clinique et les hémocultures. Lorsque le doute persiste, une ablation chirurgicale suivie de la mise en culture des prélèvements chirurgicaux et du cathéter permettent de poser le diagnostic. En clinique, après ces examens, nous constatons que seule la moitié des cathéters retirés étaient réellement infectés. Alors que la tomographie par émission de positons fusionnée à la tomographie (PET/CT) a montré de bons résultats dans la détection des infections chroniques, la valeur diagnostique du PET/CT au fluorodeoxyglucose marqué au 18F (18F-FDG) pour les infections de CVCP n'a encore jamais été déterminée dans une étude prospective. Objectifs Au travers de cette étude prospective, ouverte et monocentrique, nous chercherons à connaître la valeur diagnostique du PET/CT au 18F-FDG dans la détection d'infections de CVCP et ainsi d'en déterminer son utilité. Nous essaierons aussi de déterminer la différence de valeur diagnostique du PET/CT au 18F-FDG par rapport aux méthodes conventionnelles (paramètres cliniques et culture du liquide d'aspiration), afin de se déterminer sur l'éventuelle utilité diagnostique de celui-ci. Méthodes Cadre : Etude prospective d'au moins 20 patients, avec 2 groupes contrôles d'au moins 10 patients ayant chacun respectivement une faible et une forte probabilité d'infection, soit au moins 40 patients au total. Population : patients adultes avec CVCP devant être retiré. Cette étude prévoit un examen PET/CT au 18F-FDG effectué auprès de patients nécessitant une ablation de CVCP sur suspicion d'infection, sans confirmation possible par les moyens diagnostiques non chirurgicaux. Deux acquisitions seront réalisées 45 et 70 minutes après l'injection de 5,5MBq/Kg de 18F-FDG. Le groupe contrôle à faible probabilité d'infection, sera formé de patients bénéficiant de l'ablation définitive d'un CVCP pour fin de traitement durant le laps de temps de l'étude, et ayant bénéficié au préalable d'un examen PET/CT pour raison X. Après avoir retiré chirurgicalement le CVCP, nous utiliserons la culture microbiologique des deux extrémités du CVCP comme étalon d'or (gold standard) de l'infection. Le groupe contrôle à forte probabilité d'infection sera formé de patients nécessitant une ablation de CVCP sur infection de CVCP confirmée par les moyens diagnostiques non chirurgicaux (culture positive du liquide de l'aspiration). Lors de l'examen PET/CT, ces patients auront aussi deux acquisitions réalisées 45 et 70 minutes après l'injection de 5,5MBq/Kg de 18F-FDG. Les résultats de ces examens seront évalués par deux spécialistes en médecine nucléaire qui détermineront le niveau de suspicion de l'infection sur une échelle de Likert allant de I à V, sur la base du nombre de foyers, de la localisation du foyer, de l'intensité de la captation de 18F-FDG au voisinage du cathéter et du rapport tissu/arrière-plan. Par la suite, nous retirerons chirurgicalement le CVCP. Nous utiliserons la culture microbiologique du pus (si présent), des deux extrémités du CVCP ainsi que l'histologie des tissus formant un tunnel autour du cathéter comme étalon d'or de l'infection. Les résultats seront analysés à l'aide de courbes ROC (Receiver Operating Characteristic) afin de déterminer la valeur diagnostique du PET/CT dans l'infection de CVCP. Les résultats des examens des patients avec suspicion clinique d'infection seront ensuite analysés séparément, afin de déterminer la différence de valeur diagnostique du PET/CT au 18F-FDG par rapport aux méthodes conventionnelles. Résultats escomptés Ce projet veut chercher à savoir si le PET/CT au 18F-FDG peut être un moyen diagnostique valide dans les infections de CVCP, s'avérer utile lorsque les autres moyens diagnostiques sont non conclusifs. Plus-value escomptée Actuellement, lors d'incertitude sur le diagnostic d'infection de CVCP, une opération chirurgicale est effectuée à titre préventif afin d'enlever le cathéter en cause, cependant seulement la moitié de ces cathéters sont réellement infectés en pratique. Le PET/CT au 18F-FDG, grâce à sa sensibilité élevée et probablement une bonne valeur prédictive négative, pourrait éviter à une partie des patients un retrait inutile du cathéter, diminuant ainsi les risques chirurgicaux et les coûts liés à de telles opérations, tout en préservant le capital d'accès vasculaire futur.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dielectric functions of InP, In0.53Ga0.47As, and In0.75Ga0.25As0.5P0.5 epitaxial layers have been measured using a polarization modulation spectroscopic ellipsometer in the 1.5 to 5.3 eV region. The oxide removal procedure has been carefully checked by comparing spectroscopic ellipsometry and x ray photoelectron spectroscopy measurements. These reference data have been used to investigate the structural nature of metalorganic chemical vapor deposition grown In0.53Ga0.47As/InP and In0.75Ga0.25As0.5P0.5/InP heterojunctions, currently used for photodiodes and laser diodes. The sharpness of the interfaces has been systematically compared for the two types of heterojunctions: In1 xGaxAsy/InP and InP/In1 xGaxAsyP1 y. The sharpest interface is obtained for InP growth on In0.75Ga0.25As0.5P0.5 where the interface region is estimated to be (10±10) Å thick. The importance of performing in situ SE measurements is emphasized.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä työssä selostetaan kuumalanka-anemometrin käyttö virtausmittauksissa. Kuumalanka-anemometrilla saadaan mitattua virtausnopeuden ja -suunnan lisäksi nopeusheilahteluja. Mittaustaajuus on tyypillisesti useita kymmeniä tuhansia mittauksia sekunnissa ja signaali on jatkuva. Nykytekniikalla pystytään helposti tallentamaan mittauslaitteistolta saatu viesti tietokoneelle ja muuntamaan se nopeudeksi. Hetkellisten nopeuksien avulla voidaan laskea turbulenttisen virtauksen ominaisuuksia, kuten turbulenssin intensiteetti ja spektri. Kuumalanka-anemometrissa lämmitetään sähköisesti ohutta lankaa, joka on mitattavassa virtauksessa. Langan sähköteho on suunnilleen yhtäsuuri kuin langasta konvektiolla siirtyvä lämpöteho. Tällöin on teoreettisesti mahdollista laskea virtausnopeus lämpötehosta lämmönsiirtokorrelaatioilla. Käytännössä laitteisto joudutaan kuitenkin erikseen kalibroimaan, mutta sähkötehon teoreettista riippuvuutta konvektiosta käytetään hyväksi. Kuumalangan lämmitettävä osuus on tyypillisesti halkaisijaltaan 5 µm ja pituudeltaan noin 1 mm. Sitä käytetään pääasiassa kaasuvirtausten mittaamiseen ja valtaosassa mittauksissa virtausaineena on ilma. Kuumalanka voi olla toteutettu kuumakalvotekniikalla, jossa halkaisijaltaan noin 50 - 70 µm paksuinen kuitu on päällystetty ohuella sähköä johtavalla kalvolla. Kuumakalvoanturin ei tarvitse olla muodoltaan sylinterimäinen, se voi olla mm. kartiomainen tai kiilamainen. Erikoispäällystetyllä kuumakalvoanturilla on mahdollista mitata myös nestevirtauksia. Mitattaessa kaasuvirtauksia kuumakalvon etuna on selvästi parempi kestävyys verrattuna kuumalankaan. Nimitystä kuumalanka-anemometri käytetään yleisesti molemmista anturityypeistä Tämän työn alussa käsitellään sylinterin yli tapahtuvaan virtaukseen liittyvää virtausmekaniikkaa ja lämmönsiirtoa. Anemometrin sähköinen osa, laitteisto ja sen kalibrointi käydään läpi. Langan suuntariippuvuuden laskentaan esitetään tarvittavat yhtälöt. Työssä esitellään kolme laitteistolla tehtyä perusmittausta: anturin kohtauskulman muuttaminen, pyörähdyssymmerisen suihkun nopeuskenttä ja tuulitunnelin rajakerros. Lisäksi esitellään yksi käytännöllinen ja vaativampi mittaus, jossa on mitattu nopeusprofiili radiaalikompressorin diffuusorin loppuosassa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Elektroniikan pienentyessä ja tehotiheyden kasvaessa tarvitaan paremmin suunniteltuja jäähdytysjärjestelyjä. Suunnittelun apuna voidaan käyttää perinteisiä lämmönsiirtoyhtälöitä, virtauslaskentaa ja mittauksia. Tässä työssä on suunniteltu ja rakennettu mittauslaitteisto nimenomaan elektroniikan komponenttien ja jäähdytyselementtien lämpötilojen ja painehäviöiden mittaamiseen. Koeajona laitteistolla on mitattu jäähdytyselementin lämpötilajakauma kahdella eri virtausnopeudella ja lämpötilalla sekä verrattu niitä aikaisemmin mitattuihin tapauksiin sekä Fluent- virtauslaskentaohjelmalla laskettuihin tuloksiin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The oxidative potential (OP) of particulate matter has been proposed as a toxicologically relevant metric. This concept is already frequently used for hazard characterization of ambient particles but it is still seldom applied in the occupational field. The objective of this study was to assess the OP in two different types of workplaces and to investigate the relationship between the OP and the physicochemical characteristics of the collected particles. At a toll station, at the entrance of a tunnel ('Tunnel' site), and at three different mechanical yards ('Depot' sites), we assessed particle mass (PM4 and PM2.5 and size distribution), number and surface area, organic and elemental carbon, polycyclic aromatic hydrocarbon (PAH), and four quinones as well as iron and copper concentration. The OP was determined directly on filters without extraction by using the dithiothreitol assay (DTT assay-OP(DTT)). The averaged mass concentration of respirable particles (PM4) at the Tunnel site was about twice the one at the Depot sites (173±103 and 90±36 µg m(-3), respectively), whereas the OP(DTT) was practically identical for all the sites (10.6±7.2 pmol DTT min(-1) μg(-1) at the Tunnel site; 10.4±4.6 pmol DTT min(-1) μg(-1) at the Depot sites). The OP(DTT) of PM4 was mostly present on the smallest PM2.5 fraction (OP(DTT) PM2.5: 10.2±8.1 pmol DTT min(-1) μg(-1); OP(DTT) PM4: 10.5±5.8 pmol DTT min(-1) μg(-1) for all sites), suggesting the presence of redox inactive components in the PM2.5-4 fraction. Although the reactivity was similar at the Tunnel and Depot sites irrespective of the metric chosen (OP(DTT) µg(-1) or OP(DTT) m(-3)), the chemicals associated with OP(DTT) were different between the two types of workplaces. The organic carbon, quinones, and/or metal content (Fe, Cu) were strongly associated with the DTT reactivity at the Tunnel site whereas only Fe and PAH were associated (positively and negatively, respectively) with this reactivity at the Depot sites. These results demonstrate the feasibility of measuring of the OP(DTT) in occupational environments and suggest that the particulate OP(DTT) is integrative of different physicochemical properties. This parameter could be a potentially useful exposure proxy for investigating particle exposure-related oxidative stress and its consequences. Further research is needed mostly to demonstrate the association of OP(DTT) with relevant oxidative endpoints in humans exposed to particles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the past 2 decades, there has been an increase in both basic science research detailing the anatomy and biomechanics of the native posterior cruciate ligament (PCL) and outcome studies evaluating manage- ment of the ruptured PCL. While the methodology of the latter continues to improve, results based on the current level of evidence must be interpreted cautiously (18). The focus of many recent studies has been double-bundle versus single-bundle reconstruction techniques. The theoretical advantage goes to double-bundle techniques, but a clinical difference in outcome has not been consistently demonstrated (8,17). Some biomechanical studies have reported improved control of posterior laxity with double-bundle reconstruc- tion; however, results appear to be more dependent on tunnel position and graft tensioning (13). In acute isolated symptomatic PCL injuries in which the posteromedial bundle and the meniscofemoral ligament remain intact, a single-bundle augmentation procedure may be the preferred surgical technique. In more complex PCL ruptures with associated injuries involving the posterolateral structures (PLS) or medial collateral ligament, more benefit may be derived from double-bundle reconstruction. Again, cadaveric testing of double-bundle PCL reconstruction has not consistently outperformed single-bundle techniques in combined PCL/PLS injury (3). Multi-ligamentous injuries are commonly associated with PCL rupture (15), and their management should be considered carefully in the decision to reconstruct one or both of the functionally dis- tinct PCL bundles. However, the technical complexity of double-bundle reconstruction, the longer surgical time required, as well as the inconclusive clinical outcome are all factors that must be weighed carefully.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

« Les yeux sont du visage humain la partie la plus noble et la plus importante, les yeux sont composés de corps, d'âme et d'esprit, ou plutôt les yeux sont la fenêtre où l'âme et l'esprit viennent se montrer » (Alphonse Karr, 1853). L'oeil est le regard, mais pour l'ophtalmologue il est aussi une fenêtre ouverte et un regard possible sur le reste du corps. Prolongement du système nerveux central en contact direct avec le monde extérieur dont il est l'un des « senseurs » le plus subtil et le plus complexe, il est sujet à des réactions inflammatoires, allergiques et toxiques chez l'enfant et chez l'adulte. Alors que notre environnement visuel change (modification des systèmes d'éclairage domestique dans les villes, écrans, mode de vie et habitudes de travail), que les polluants se multiplient et se combinent et que les environnements climatisés deviennent la règle, le nombre de patients souffrant de pathologies de la surface oculaire atteint 30 % des motifs de nos consultations et le nombre des patients myopes est en hausse. L'oeil est l'un des « senseurs » le plus subtil et le plus complexe Si la surface oculaire peut aussi être le témoin des pathologies systémiques, c'est la rétine qui en est plus fréquemment le reflet. Les atteintes du lit vasculaire, du nerf optique ou de la rétine peuvent être des manifestations de pathologies générales ou d'effets secondaires ou toxiques de médicaments. L'examen du fond d'oeil et la rétinophotographie restent les examens de dépistage de référence en particulier pour la rétinopathie diabétique, véritable fléau mondial et première cause de cécité dans les pays industrialisés chez les jeunes adultes. Mais ce n'est que par la collaboration entre ophtalmologues, médecins traitants et autres spécialistes que les pathologies rétiniennes peuvent être prises en charge de façon optimale pour qu'à des traitements oculaires spécifiques soit associée la prise en charge globale des maladies causales ou interférentes. Au-delà du fond d'oeil, les progrès technologiques contribuent au développement de multiples méthodes d'exploration des différentes structures de l'oeil offrant ainsi la possibilité d'utiliser l'oeil comme témoin de manifestations précoces de maladies neurologiques périphériques ou centrales. L'imagerie cornéenne semble aujourd'hui capable de révéler et de suivre de façon longitudinale la neuropathie diabétique périphérique et il n'est pas impossible que la rétine devienne le site de détection précoce de la maladie d'Alzheimer. Sur le plan de la prise en charge, l'ophtalmologue ne peut pas se contenter de traiter l'oeil, il doit aussi assurer une prise en charge pluridisciplinaire et accompagner le patient qui, perdant la vision, est sujet à la dépression et à la majoration de tout autre handicap. La perte visuelle est le handicap le plus redouté des populations et la perte d'autonomie qu'il induit limite l'observance et le suivi thérapeutique (comparable en termes de gravité ressentie à un « alitement brutal dans les suites d'un AVC »). La médecine personnalisée et les interactions multidisciplinaires prennent ici tout leur sens. Les développements thérapeutiques ont été majeurs ces dernières années et la cécité n'est plus une fatalité, au moins dans certains cas. Mais la rétine étant un tissu nerveux post-mitotique, les traitements et donc le dépistage doivent être précoces pour prévenir la perte visuelle irréversible. Spécifiquement, les espoirs lointains comme la thérapie génique entrent dans les essais cliniques laissant entrevoir la lumière au bout du tunnel. A portée de vue, la rétine artificielle constitue une avancée concrète, encore perfectible mais accessible dès aujourd'hui. Si les progrès sont manifestes dans le domaine de l'ophtalmologie, il reste encore beaucoup à apprendre et à comprendre en particulier dans les mécanismes pathogéniques multifactoriels des maladies oculaires plus fréquentes. Seule une exploration approfondie des maladies humaines pourra nous permettre de mieux appréhender de nouvelles stratégies thérapeutiques. Comme le disait André Isaac (1893-1975), pour voir loin, il faut regarder de près.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avec cette thèse de doctorat nous proposons une réflexion transversale concernant les relations entre infrastructures de transport et développement territorial dans des espaces dits « intermédiaires ». Le concept d'espace intermédiaire, relativement nouveau en géographie, est conçu en fonction d'une double approche : celle des infrastructures où les espaces intermédiaires constituent des zones de transit obligées entre des pôles urbains hiérarchiquement supérieurs (par rapport une échelle horizontale) et celle des frontières où les espaces intermédiaires constituent des territoires de coopération entre différents niveaux politico-institutionnels (par rapport à une échelle verticale). Cette problématique de recherche est traitée aussi bien du point de vue théorique qu'avec des études de cas portant sur les effets des nouvelles infrastructures de transports dans la région transfrontalière insubrique (entre le Canton du Tessin et la Lombardie). L'objectif visé est de défendre un scénario d'organisation spatiale polycentrique à plusieurs niveaux comme solution pour le développement durable et cohérent de ces espaces intermédiaires. Ainsi, pour le « niveau macro », nous proposons une analyse des changements d'accessibilité spatiale et des potentiels de développement territorial pour les agglomérations concernées par la mise en service du nouveau tunnel ferroviaire de base du Monte Ceneri (TBC) et de la nouvelle ligne Lugano/Como-Mendrisio-Varese-Malpensa (FMV) à l'horizon 2020. Pour le « niveau meso », nous analysons les effets de la nouvelle ligne FMV en termes de potentiel de densification polycentrique autours des gares ferroviaires. Pour le « niveau micro », nous proposons une analyse sur les comportements de mobilité ainsi que des améliorations ciblées du système de transport pour la ville de Mendrisio visant à promouvoir le développement polycentrique de cette commune. De plus, un système d'analyse permettant de mettre en lien les divers facteurs explicatifs dans l'analyse des relations entre les nouvelles infrastructures de transport et les effets sur la mobilité et le développement territorial est également élaboré et testé dans notre recherche. -- With this Ph.D. thesis we investigate the relationship between transport infrastructures and territory development inside the so called "in-between spaces". The idea of "in-between space", relatively novel in geography, is the formal outcome of a double approach: the one of the infrastructures, saying that these spaces can be described as areas of constrained transit between urban centres of superior hierarchical level (on a horizontal scale), and the one of the borders, stating that in-between spaces are areas of cooperation between various political-institutional levels. The above mentioned research issues are deepened both at theoretical and empirical level, being the latter based on field studies of the cross-boundary Western-Lombard area (between the Swiss canton of Ticino and the Italian region of Lombardy). This research pursues the goal of defending the argument that a multi-level polycentric spatial scenario can be a possible solution fora sustainable development of the above described in- between areas. From a "macro" perspective, what we submit here is an analysis on the expected changes in spatial accessibility and on the potential territorial development for the built-up areas influenced by the construction of the new train tunnel of the Monte Ceneri (TBC) and of the new railway line Lugano/Como-Mendrisio-Varese-Malpensa (FMV). At a "meso" level we analyse the effects exerted by the new FMV line taking into account the potential densification of the areas surrounding the railway stations. Finally, at a "micro" level, we analyse the mobility behaviours in the town of Mendrisio and we propose some possible improvements to the local public transport system, with the scope to promote a polycentric development of this municipality. Moreover, we developed and tested an analytic system able to define the existing links between the various explaining factors characterizing the relationship between new transport infrastructures and effects on mobility. -- With this Ph.D. thesis we investigate the relationship between transport infrastructures and territory development inside the so called "in-between spaces". The idea of "in-between space", relatively novel in geography, is the formal outcome of a double approach: the one of the infrastructures, saying that these spaces can be described as areas of constrained transit between urban centres of superior hierarchical level (on a horizontal scale), and the one of the borders, stating that in-between spaces are areas of cooperation between various political-institutional levels. The above mentioned research issues are deepened both at theoretical and empirical level, being the latter based on field studies of the cross-boundary Western-Lombard area (between the Swiss canton of Ticino and the Italian region of Lombardy). This research pursues the goal of defending the argument that a multi-level polycentric spatial scenario can be a possible solution for a sustainable development of the above described in- between areas. From a "macro" perspective, what we submit here is an analysis on the expected changes in spatial accessibility and on the potential territorial development for the built-up areas influenced by the construction of the new train tunnel of the Monte Ceneri (TBC) and of the new railway line Lugano/Como-Mendrisio-Varese-Malpensa (FMV). At a "meso" level we analyse the effects exerted by the new FMV line taking into account the potential densification of the areas surrounding the railway stations. Finally, at a "micro" level, we analyse the mobility behaviours in the town of Mendrisio and we propose some possible improvements to the local public transport system, with the scope to promote a polycentric development of this municipality. Moreover, we developed and tested an analytic system able to define the existing links between the various explaining factors characterizing the relationship between new transport infrastructures and effects on mobility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The truncated hemoglobin N, HbN, of Mycobacterium tuberculosis is endowed with a potent nitric oxide dioxygenase (NOD) activity that allows it to relieve nitrosative stress and enhance in vivo survival of its host. Despite its small size, the protein matrix of HbN hosts a two-branched tunnel, consisting of orthogonal short and long channels, that connects the heme active site to the protein surface. A novel dual-path mechanism has been suggested to drive migration of O(2) and NO to the distal heme cavity. While oxygen migrates mainly by the short path, a ligand-induced conformational change regulates opening of the long tunnel branch for NO, via a phenylalanine (PheE15) residue that acts as a gate. Site-directed mutagenesis and molecular simulations have been used to examine the gating role played by PheE15 in modulating the NOD function of HbN. Mutants carrying replacement of PheE15 with alanine, isoleucine, tyrosine and tryptophan have similar O(2)/CO association kinetics, but display significant reduction in their NOD function. Molecular simulations substantiated that mutation at the PheE15 gate confers significant changes in the long tunnel, and therefore may affect the migration of ligands. These results support the pivotal role of PheE15 gate in modulating the diffusion of NO via the long tunnel branch in the oxygenated protein, and hence the NOD function of HbN.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present an analytical procedure to perform the local noise analysis of a semiconductor junction when both the drift and diffusive parts of the current are important. The method takes into account space-inhomogeneous and hot-carriers conditions in the framework of the drift-diffusion model, and it can be effectively applied to the local noise analysis of different devices: n+nn+ diodes, Schottky barrier diodes, field-effect transistors, etc., operating under strongly inhomogeneous distributions of the electric field and charge concentration

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A theoretical model for the noise properties of Schottky barrier diodes in the framework of the thermionic-emission¿diffusion theory is presented. The theory incorporates both the noise inducedby the diffusion of carriers through the semiconductor and the noise induced by the thermionicemission of carriers across the metal¿semiconductor interface. Closed analytical formulas arederived for the junction resistance, series resistance, and contributions to the net noise localized indifferent space regions of the diode, all valid in the whole range of applied biases. An additionalcontribution to the voltage-noise spectral density is identified, whose origin may be traced back tothe cross correlation between the voltage-noise sources associated with the junction resistance andthose for the series resistance. It is argued that an inclusion of the cross-correlation term as a newelement in the existing equivalent circuit models of Schottky diodes could explain the discrepanciesbetween these models and experimental measurements or Monte Carlo simulations.