970 resultados para Pressure-Sensitive Dilatant Material


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study was to investigate the influence of the menstrual cycle and oral contraceptive (OC) intake on the pressure pain threshold (PPT) of masticatory muscles in patients with masticatory myofascial pain (MFP). Study design. The sample was composed of 36 women, divided into 4 groups, according to the presence of MFP and the intake of OC (15 patients had MFP [7 taking OC] and 21 were pain-free controls [8 taking OC]). The algometer-based PPT of masseter and temporalis, and the record of subjective pain by visual analog scale (VAS) were determined during 2 consecutives menstrual cycles at 4 phases (menstrual, follicular, periovulatory, and luteal). A 3-way ANOVA for repeated measurements, Kruskal-Wallis, Friedman, and Dunn tests, with a 5% significant level analyzed the data. Results. PPT was significantly lower in MFP patients when compared with controls throughout the experiment (P < .001). The menstrual phases did not influence PPT (P > .05), while the intake of OC seems to raise PPT levels for the left temporalis (P = .01) and right masseter (P = .04). VAS was, in general, higher at the menstrual phase Conclusions. Different phases of the menstrual cycle have no influence on PPT values, regardless of the presence of a previous condition, as masticatory myofascial pain, while the intake of OC is associated with decreased levels of reported pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant loss in electron probe current can occur before the electron beam enters the specimen chamber of an environmental scanning electron microscope (ESEM). This loss results from electron scattering in a gaseous jet formed inside and downstream (above) the pressure-limiting aperture (PLA), which separates the high-pressure and high-vacuum regions of the microscope. The electron beam loss above the PLA has been calculated for three different ESEMs, each with a different PLA geometry: an ElectroScan E3, a Philips XL30 ESEM, and a prototype instrument. The mass thickness of gas above the PLA in each case has been determined by Monte Carlo simulation of the gas density variation in the gas jet. It has been found that the PLA configurations used in the commercial instruments produce considerable loss in the electron probe current that dramatically degrades their performance at high chamber pressure and low accelerating voltage. These detrimental effects are minimized in the prototype instrument, which has an optimized thin-foil PLA design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Variable aspect ratio porphyroblasts deformed in non-coaxial flow. and internally containing rotated relicts of an external foliation, can be used to characterise plane strain flow regimes. The distribution obtained by plotting the orientation of the long axis of such grains, classified by aspect ratio, against the orientation of the internal foliation is potentially a sensitive gauge of both the bulk shear strain (as previously suggested) and kinematic vorticity number. We illustrate the method using rotated biotite porphyroblasts in the Alpine Schist: a sequence of mid-crustal rocks that have been ramped to the surface along the Alpine Fault. a major transpressional plate boundary. Results indicate that, at distances greater than or equal to similar to1 km from the fault, the rocks have undergone a combination of irrotational fattening and dextral-oblique, normal-sense shear, with a bulk shear strain of similar to0.6 and kinematic vorticity number of similar to0.2. The vorticity analysis is compatible with estimates of strongly oblate bulk strain of similar to 75% maximum shortening. Dextral-reverse transpressional flow characterises higher strain S-tectonite mylonite within similar to1 km of the Alpine Fault. These relationships provide insight into the kinematics of flow and distribution of strain in the hangingwall of the Alpine Fault and place constraints on numerical mechanical models for the exhumation of these mid-crustal rocks. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of pattern coating with spinel-based investment Rematitan Ultra (RU) on the castability and internal porosity of commercially pure (CP) titanium invested into phosphate-bonded investments. The apparent porosity of the investment was also measured. Materials and Methods: Square patterns (15 x 15 x 0.3 mm(3)) were either coated with RU, or not and invested into the phosphate-bonded investments: Rematitan Plus (RP), Rema Exakt (RE), Castorit Super C (CA), and RU (control group). The castings were made in an Ar-arc vacuum-pressure machine. The castability area (mm(2)) was measured by an image-analysis system (n = 10). For internal porosity, the casting (12 x 12 x 2 mm(3)) was studied by the X-ray method, and the projected porous area percentage was measured by an image-analysis system (n = 10). The apparent porosity of the investment (n = 10) was measured in accordance with the ASTM C373-88 standard. Results: Analysis of variance (One-way ANOVA) of castability was significant, and the Tukey test indicated that RU had the highest mean but the investing technique with coating increased the castability for all phosphate-bonded investments. The analysis of the internal porosity of the cast by the nonparametric test demonstrated that the RP, RE, and CA with coating and RP without coating did not differ from the control group (RU), while the CA and RE casts without coating were more porous. The one-way ANOVA of apparent porosity of the investment was significant, and the Tukey test showed that the means of RU (36.10%) and CA (37.22%) were higher than those of RP (25.91%) and RE (26.02%). Conclusion: Pattern coating with spinel-based material prior to phosphate-bonded investments can influence the castability and the internal porosity of CP Ti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are many methods for the analysis and design of embedded cantilever retaining walls. They involve various different simplifications of the pressure distribution to allow calculation of the limiting equilibrium retained height and the bending moment when the retained height is less than the limiting equilibrium value, i.e. the serviceability case. Recently, a new method for determining the serviceability earth pressure and bending moment has been proposed. This method makes an assumption defining the point of zero net pressure. This assumption implies that the passive pressure is not fully mobilised immediately below the excavation level. The finite element analyses presented in this paper examine the net pressure distribution on walls in which the retained height is less, than the limiting equilibrium value. The study shows that for all practical walls, the earth pressure distributions on the front and back of the wall are at their limit values, Kp and K-a respectively, when the lumped factor of safety F-r is less than or equal to2.0. A rectilinear net pressure distribution is proposed that is intuitively logical. It produces good predictions of the complete bending moment diagram for walls in the service configuration and the proposed method gives results that have excellent agreement with centrifuge model tests. The study shows that the method for determining the serviceability bending moment suggested by Padfield and Mair(1) in the CIRIA Report 104 gives excellent predictions of the maximum bending moment in practical cantilever walls. It provides the missing data that have been needed to verify and justify the CIRIA 104 method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Palpation for tenderness forms an important part of the manual therapy assessment for musculoskeletal dysfunction, In conjunction with other testing procedures it assists in establishing the clinical diagnosis. Tenderness in the thoracic spine has been reported in the literature as a clinical feature in musculoskeletal conditions where pain and dysfunction are located primarily in the upper quadrant. This study aimed to establish whether pressure pain thresholds (PPTs) of the mid-thoracic region of asymptomatic subjects were naturally lower than those of the cervical and lumbar areas. A within-subject study design was used to examine PPT at four spinal levels C6, T4, T6, and L4 in 50 asymptomatic volunteers. Results showed significant (P < 0.001) regional differences. PPT values increased in a caudal direction. The cervical region had the lowest PPT scores, that is was the most tender. Values increased in the thoracic region and were highest in the lumbar region. This study contributes to the normative data on spinal PPT values and demonstrates that mid-thoracic tenderness relative to the cervical spine is not a normal finding in asymptomatic subjects. (C) 2001 Harcourt Publishers Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eggs from the Heron Island, Great Barrier Reef, nesting population of green turtles (Chelonia mydas) were incubated at all-male-determining (26 degreesC) and all-female-determining (30 degreesC) temperatures. Oxygen consumption and embryonic growth were monitored throughout incubation, and hatchling masses and body dimensions were measured from both temperatures. Eggs hatched after 79 and 53 days incubation at 26 degreesC and 30 degreesC respectively. Oxygen consumption at both temperatures increased to a peak several days before hatching, a pattern typical of turtle embryos, and the rate of oxygen was higher at 30 degreesC than 26 degreesC. The total amount of energy consumed during incubation, and hatchling dimensions, were similar at both temperatures, but hatchlings from 26 degreesC had larger mass, larger yolk-free mass and smaller residual yolks than hatchlings from 30 degreesC. Because of the difference in mass of hatchlings, hatchlings from 30 degreesC had a higher production cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the limit state design (LSD) method each design criterion is formally stated and assessed using a performance function. The performance function defines the relationship between the design parameters and the design criterion. In practice, LSD involves factoring up loads and factoring down calculated strengths and material parameters. This provides a convenient way to carry out routine probabilistic-based design. The factors are statistically calculated to produce a design with an acceptably low probability of failure. Hence the ultimate load and the design material properties are mathematical concepts that have no physical interpretation. They may be physically impossible. Similarly, the appropriate analysis model is also defined by the performance function and may not describe the real behaviour at the perceived physical equivalent limit condition. These points must be understood to avoid confusion in the discussion and application of partial factor LSD methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have utilised the combination of sensitivity and specificity afforded by coupling high-performance liquid chromatography (HPLC) to a tandem mass spectrometer (MS-MS) to produce an assay which is suitable for assaying glutathione (GSH) concentrations in liver tissue. The sensitivity suggests it may also be suitable for extrahepatic tissues, The method has been validated for GSH using mouse liver samples and also allows the assay of GSSG. The stability of GSH under conditions relevant to the assay has been determined. A 20-mul amount of a diluted methanol extract of tissue is injected with detection limits of 0.2 pmol for GSH and 2 pmol for GSSG. The HPLC uses an Altima C-18 (150X4.6 mm, 5 mum) column at 35 degreesC. Chromatography utilises a linear gradient from 0 to 10% methanol in 0.1% formic acid over 5 min, with a final isocratic stage holding at 10% methanol for 5 min. Total flow rate is 0.8 ml/min. The transition from the M+H ion (308.1 m/z for GSH, and 613.3 m/z for GSSG) to the 162.0 m/z (GSH) and 355.3 m/z (GSSG) fragments are monitored. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method has been established to define the limits on a spontaneous mutation rate for a gene in Plasmodium falciparum. The method combines mathematical modelling and large-scale in vitro culturing and calculates the difference in mutant frequencies at 2 separate time-points. We measured the mutation rate at 2 positions in the dihydrofolate reductase (DHFR) gene of 3D7, a pyrimethamine-sensitive line of P. fulciparum. This line was re-cloned and an effectively large population was treated with a selective pyrimethamine concentration of 40 nM. We detected point mutations at codon-46 (TTA to TCA) and codon-108 (ACC to AAC), resulting in serine replacing leucine and asparagine replacing serine respectively in the corresponding gene product. The substitutions caused a decrease in pyrimethamine sensitivity. By mathematical modelling we determined that the mutation rate at a given position in DHFR was low and occurred at less than 2(.)5 x 10(-9) mutations/DHFR gene/replication. This result has important implications for Plasmodium genetic diversity and antimalarial drug therapy by demonstrating that even with lon mutation rates anti-malarial resistance will inevitably arise when mutant alleles are selected under drug pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Expansion tubes operating at total flow enthalpies of 100 MJ kg(-1) or more have characteristical test times of 30-50 mus. Under these conditions, the response time of the Pitot pressure measuring device is critical when performing flow calibration studies. The conventional technique of using a commercial pressure transducer protected by shielding has not always proven to be effective, due to the relatively large (and variable) response time caused by the shielding. A device called the stress wave bar gauge has been designed and calibrated and shown to be an effective way to measure the Pitot pressure with a response time of only 2-3 mus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The basic morphology of the skeleton is determined genetically, but its final mass and architecture are modulated by adaptive mechanisms sensitive to mechanical factors. When subjected to loading, the ability of bones to resist fracture depends on their mass, material properties, geometry and tissue quality. The contribution of altered bone geometry to fracture risk is unappreciated by clinical assessment using absorptiometry because it fails to distinguish geometry and density. For example, for the same bone area and density, small increases in the diaphyseal radius effect a disproportionate influence on torsional strength of bone. Mechanical factors are clinically relevant because of their ability to influence growth, modeling and remodeling activities that can maximize, or maintain, the determinants of fracture resistance. Mechanical loads, greater than those habitually encountered by the skeleton, effect adaptations in cortical and cancellous bone, reduce the rate of bone turnover, and activate new bone formation on cortical and trabecular surfaces. In doing so, they increase bone strength by beneficial adaptations in the geometric dimensions and material properties of the tissue. There is no direct evidence to demonstrate anti-fracture efficacy for mechanical loading, but the geometric alterations engendered undoubtedly increase the structural properties of bone as an organ, increasing the resistance to fracture. Like all interventions, issues of safety also arise. Physical activities involving high strain rates, heavy lifting or impact loading may be detrimental to the joints, leading to osteoarthritis; may stimulate fatigue damage leading with some to stress fractures; or may interact pharmaceutical interventions to increase the rate of microdamage within cortical or trabecular bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent progress in the production, purification, and experimental and theoretical investigations of carbon nanotubes for hydrogen storage are reviewed. From the industrial point of view, the chemical vapor deposition process has shown advantages over laser ablation and electric-arc-discharge methods. The ultimate goal in nanotube synthesis should be to gain control over geometrical aspects of nanotubes, such as location and orientation, and the atomic structure of nanotubes, including helicity and diameter. There is currently no effective and simple purification procedure that fulfills all requirements for processing carbon nanotubes. Purification is still the bottleneck for technical applications, especially where large amounts of material are required. Although the alkali-metal-doped carbon nanotubes showed high H-2 Weight uptake, further investigations indicated that some of this uptake was due to water rather than hydrogen. This discovery indicates a potential source of error in evaluation of the storage capacity of doped carbon nanotubes. Nevertheless, currently available single-wall nanotubes yield a hydrogen uptake value near 4 wt% under moderate pressure and room temperature. A further 50% increase is needed to meet U.S. Department of Energy targets for commercial exploitation. Meeting this target will require combining experimental and theoretical efforts to achieve a full understanding of the adsorption process, so that the uptake can be rationally optimized to commercially attractive levels. Large-scale production and purification of carbon nanotubes and remarkable improvement of H-2 storage capacity in carbon nanotubes represent significant technological and theoretical challenges in the years to come.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report outlines the development of optimized particle inflow gun (PIG) parameters for producing transgenic sorghum (Sorghum bicolor (L.) Moench). Both transient and stable expression were examined when determining these parameters. The uidA reporter gene (GUS) encoding beta -glucuronidase was used in transient experiments and the green fluorescent protein (GFP) used to monitor stable expression. Initially, optimization was conducted using leaf segments, as the generation of sorghum callus in sufficiently large quantities is time-consuming. Following leaf optimization, experiments were conducted using callus, identifying a high similarity between the two tissue types (r(s) = 0.83). High levels of GUS expression were observed in both leaf and callus material when most distant from the DNA expulsion point, and using a pressure greater than 1800 kPa. A higher level of expression was also observed when the aperture of the helium inlet valve was constricted. Using the optimized conditions (pressure of 2200 kPa, distance to target tissue of 15 cm from the expulsion point, and the aperture of the helium inlet valve at one full turn), three promoters (Ubiquitin, Actin1 and CaMV 35S) were evaluated over a 72-h period using GUS as the reporter gene. A significantly higher number of GUS foci were counted with the Ubiquitin construct over this period, compared to the Actin1 and CaMV 35S constructs. Stable callus sectors (on 2 mg l(-1) bialaphos) with GFP expression were visualized for as long as 6 wk post-bombardment. Using this optimized protocol, several plants were regenerated after having been bombarded with the pAHC20 construct (containing the bar gene), with molecular evidence confirming integration.