920 resultados para Guided missiles.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objectives: Improved ultrasound and needle technology make popliteal sciatic nerve blockade a popular anesthetic technique and imaging to localize the branch point of the common peroneal and posterior tibial components is important because successful blockade techniques vary with respect to injection of the common trunk proximally or separate injections distally. Nerve stimulation, ultrasound, cadaveric and magnetic resonance studies demonstrate variability in distance and discordance between imaging and anatomic examination of the branch point. The popliteal crease and imprecise, inaccessible landmarks render measurement of the branch point variable and inaccurate. The purpose of this study was to use the tibial tuberosity, a fixed bony reference, to measure the distance of the branch point. Method: During popliteal sciatic nerve blockade in the supine position the branch point was identified by ultrasound and the block needle was inserted. The vertical distance from the tibial tuberosity prominence and needle insertion point was measured. Results: In 92 patients the branch point is a mean distance of 12.91 cm proximal to the tibial tuberosity and more proximal in male (13.74 cm) than female patients (12.08 cm). Body height is related to the branch point distance and is more proximal in taller patients. Separation into two nerve branches during local anesthetic injection supports notions of more proximal neural anatomic division. Limitations: Imaging of the sciatic nerve division may not equal its true anatomic separation. Conclusion: Refinements in identification and resolution of the anatomic division of the nerve branch point will determine if more accurate localization is of any clinical significance for successful nerve blockade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sciatic nerve blockade (SNB) can be performed at several point along its anatomic course. Proximal SNB techniques described include the classic Labat, sacral (Mansur), infragluteal (Raj), and anterior approches Distal SNB techniques include the mid-femoral, posterior and lateral popliteal and mid-tibial approaches. The anatomic region of the lower extramity to be anesthetixzed will determine the appropriate SNB technique to use for the operative procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The saphenous nerve (SaN) innervates the region from the upper medial thigh to the medial aspect of the foot and ankle. A femoral nerve block (FNB) is effective for blockade of the SaN but this causes quadriceps weekness and reduced patient mobility that is unsuitable in an ambulatory surgical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In various signal-channel-estimation problems, the channel being estimated may be well approximated by a discrete finite impulse response (FIR) model with sparsely separated active or nonzero taps. A common approach to estimating such channels involves a discrete normalized least-mean-square (NLMS) adaptive FIR filter, every tap of which is adapted at each sample interval. Such an approach suffers from slow convergence rates and poor tracking when the required FIR filter is "long." Recently, NLMS-based algorithms have been proposed that employ least-squares-based structural detection techniques to exploit possible sparse channel structure and subsequently provide improved estimation performance. However, these algorithms perform poorly when there is a large dynamic range amongst the active taps. In this paper, we propose two modifications to the previous algorithms, which essentially remove this limitation. The modifications also significantly improve the applicability of the detection technique to structurally time varying channels. Importantly, for sparse channels, the computational cost of the newly proposed detection-guided NLMS estimator is only marginally greater than that of the standard NLMS estimator. Simulations demonstrate the favourable performance of the newly proposed algorithm. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Australian population of the nudibranch mollusk Glossodoris atromarginata has been found to contain furanoditerpenes of the spongian series. Spongia-13(16),14-dien-3-one (1) and 3 beta-acetoxy-19-hydroxyspongia-13(16),14-dien-2-one (2) were isolated for the first time from a natural source, along with a series of known diterpenes (3-7). Anatomical dissection of the animals revealed the relative distribution and chemical variation of secondary metabolites. Structural studies have provided a basis for chemical comparisons between populations from different geographic locations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 52-year-old male with idiopathic hypereosinophilic syndrome (HES) was transferred to our institution following the development of acute respiratory failure and shock. He had previously undergone tricuspid valve replacement with bioprosthetic valves on two occasions: the initial surgery for severe native tricuspid valve stenosis and the redo surgery for severe prosthetic valve stenosis and regurgitation. Conventional imaging assessment using transoesophageal echocardiography was suboptimal and comprehensive assessment of prosthetic valve function was aided by the use of intracardiac echocardiography (ICE). ICE provided high quality 2D imaging of the prosthesis demonstrating thrombus-like material coating the inner surfaces of the prosthetic valve stents effectively forming a tunnel-like obstruction. Unusual hemodynamics secondary to severe tricuspid stenosis were demonstrated by CW Doppler with intermittent signal fusion resulting from blunted respiratory variation in the markedly elevated right atrial pressure relative to right ventricular pressure. Successful balloon valvuloplasty was performed with ICE proving highly valuable in guiding balloon position as well as monitoring the efficacy of the subsequent inflations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Observation of autosoliton propagation in a dispersion-managed optical transmission system controlled by in-line nonlinear fiber loop switches is reported for what is believed to be the first time. The system is based on a strong dispersion map with large amplifier spacing. Operation at transmission rates of 10 and 40 Gbits/s is demonstrated. ©2004 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of channel inequality on nonlinear signal switching in a nonlinear optical fiber loop mirror (NOLM) were investigated. It was found that the channel-to-channel amplitude differences in optical time division multiplexing (OTDM) have strong impact on swiching behavior of individual channels in a 2R regenerator. The optical pulses in different channels face either suppression of the amplitude noise or increase in noise, depending on the inter-channel amplitude difference. It was stated that appropriate control of the channel uniformity in the OTDM transmitters is required to support stable long-haul transmission in 2R regenerated systems.