968 resultados para Electrospray-ionization


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Galactoglucomannan (GGM) from cultures of Nicotiana plumbaginifolia has Man:Glc:Gal:Ara:Xyl in 1.0:1.1:1.0:0.1:0.04 ratio. Linkage analysis contained 4- and 4,6-Manp, 4-Glcp, terminal Galp and 2-Galp, small amounts and terminal Arap and terminal Xylp, and similar to 0.03 mol acetyl per mol of glucosyl residue. Treatment with alpha- and beta-D-galactosidases showed that the majority of the side-chains were either single Galp-alpha-(1 --> residues or the disaccharide Galp-beta-(1 --> 2)-Galp-alpha-(1 --> linked to O-6 of the 4-Manp residues of the glucomannan backbone. Analysis of the oligosaccharides generated by endo-(1 --> 4)-beta-mannanase digestion confirmed that the GGM comprises a backbone of predominantly alternating --> 4)-D-Manp-beta-(1 --> and --> Lt)-D-Glcp-beta-(1 --> branched at O-6 of 65% of the 4-Manp residues. The major oligosaccharide identified was D-Glcp-beta-(1 --> 4)-[D-Galp-beta-(1 --> 2)-D-Galp-alpha-(1 --> 6)]-D-Manp-beta-(1 --> 4)-D-Glcp-beta-(I --> 4)-[D-Galp-alpha-(1 --> 6)]-D-Manp-beta-(1 --> (27%), and most of the other oligosaccharides produced in significant quantities were based on this structure. (C) 1997 Elsevier Science Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: We report the validation of a method for the determination of acetaldehyde, acetone, methanol, and ethanol in biological fluids using manual headspace sample introduction and an acetonitrile internal standard. Method: This method uses a capillary column (I = 30 m, I.D. = 0.25 mm, dF = 0.25 mu m) installed in a gas chromatography-flame ionization detector (GC-FID) apparatus with a run time of 7.5 minutes. Results: Analysis of the retention times and the resolution of the analyte peaks demonstrated excellent separation without widening of the peaks. Precision and accuracy were good (interassay precision < 15% and recovery between 85% and 115%) in both blood and urine. Conclusion: The method was linear (r > 0.09) over the analytical measurement range (AMR) of each analyte.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two-dimensional gel electrophoresis (2-DE) was used to better understand alterations in renal metabolism induced by fluoride (F). Three groups of weanling male Wistar rats were treated with drinking water containing 0 (control), 5, or 50 ppm F for 60 days (n=6/group). Kidneys were collected for proteomic and histological (HE) analysis. After protein isolation, renal proteome profiles were examined using 2-DE and Colloidal Coomassie Blue staining. Protein spots with a 2-fold significant difference as detected by quantitative intensity analysis (image Master Platinum software) and t-test (p < 0.05) were excised and analyzed by MALDI-TOF MS (matrix assisted laser desorption ionization-time-of-flight mass spectrometry). The histological analysis revealed no damage in kidneys induced by F, except for a vascular congestion in the 50 ppm F group. Between control vs 50 ppm F, and control vs 5 ppm F groups, 12 and 6 differentially expressed proteins were detected, respectively. Six proteins, mainly related with metabolism, detoxification and housekeeping, were successfully identified. At the high F group, pyruvate carboxylase, a protein involved in the formation of oxaloacetate was found to be downregulated, while enoyl coenzyme A hydratase, involved in fatty acids oxidation, was found to be upregulated. Thus, proteomic analysis can provide new insights into the alterations in renal metabolism after F exposure, even in low doses. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The 12 cysteine residues in the flavivirus NS1 protein are strictly conserved, suggesting that they form disulfide bonds that are critical for folding the protein into a functional structure. In this study, we examined the intramolecular disulfide bond arrangement of NS1 of Murray Valley encephalitis virus and elucidated three of the six cysteine-pairing arrangements. Disulfide linkages were identified by separating tryptic-digested NS1 by reverse-phase high pressure liquid chromatography and analysing the resulting peptide peaks by protein sequencing, amino acid analysis and/or electrospray mass spectrometry. The pairing arrangements between the six amino-terminal cysteines were identified as follows: Cys(4)-Cys(15), Cys(55)-Cys(143) and Cys(179)-Cys(223). Although the pairing arrangements between the six carboxyterminal cysteines were not determined, we were able to eliminate several cysteine-pairing combinations. Furthermore, we demonstrated that all three putative N-linked glycosylation sites of NS1 are utilized and that the Asn(207) glycosylation site contains a mannose-rich glycan.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow tagging technique based upon ionic fluorescence in strontium is investigated for applications to velocity measurements in gas flows. The method is based upon a combination of two laser based spectroscopic techniques, i.e. resonantly-enhanced ionisation and laser-induced ionic fluorescence. Strontium is first ionised and then planar laser-induced fluorescence is utilised to give 2D 'bright images' of the ionised region of the flow at a given time delay. The results show that this method can be used for velocity measurements. The velocities were measured in two types of air-acetylene flames - a slot burner and a circular burner yielding velocities of 5.1 +/- 0.1 m/s and 9.3 +/- 0.2 m/s, respectively. The feasibility of the method for the determination of velocities in faster flows than those investigated here is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The class of molecular chaperones known as 14-3-3 is involved in the control of cellular growth by virtue of its apparent regulation of various signaling pathways, including the Raf/mitogen-activated protein kinase pathway. In breast cancer cells, the sigma form of 14-3-3 has been shown to interact with cyclin-dependent kinases and to control the rate of entry into mitosis. To test for a direct role for 14-3-3 in breast epithelial cell neoplasia, me have quantitated 14-3-3 protein levels using a proteomic approach based on two-dimensional electrophoresis and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF). We show here that 14-3-3 sigma protein is strongly down-regulated in the prototypic breast cancer cell lines MCF-7 and MDA-MB-231 and in primary breast carcinomas as compared with normal breast epithelial cells. In contrast, levels of the alpha, beta, delta, or zeta isoforms of 14-3-3 mere the same in both normal and transformed cells. The data support the idea that 14-3-3 sigma is involved in the neoplastic transition of breast epithelial cells by virtue of its role as a tumor suppressor; as such, it may constitute a robust marker with clinical efficacy for this pathology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Syntaxin 7 is a mammalian target soluble N-ethylmaleimide-sensitive factor attachment protein receptor (SNARE) involved in membrane transport between late endosomes and lysosomes. The aim of the present study was to use immunoaffinity techniques to identify proteins that interact with Syntaxin 7. We reasoned that this would be facilitated by the use of cells producing high levels of Syntaxin 7, Screening of a large number of tissues and cell lines revealed that Syntaxin 7 is expressed at very high levels in B16 melanoma cells. Moreover, the expression of Syntaxin 7 increased in these cells as they underwent melanogenesis. From a large scale Syntaxin 7 immunoprecipitation, we have identified six polypeptides using a combination of electrospray mass spectrometry and immunoblotting. These polypeptides corresponded to Syntaxin 7, Syntaxin 6, mouse Vps10p tail interactor 1b (mVti1b), alpha -synaptosome-associated protein (SNAP), vesicle-associated membrane protein (VAMP)8, VAMP7, and the protein phosphatase 1M regulatory subunit. We also observed partial colocalization between Syntaxin 6 and Syntaxin 7, between Syntaxin 6 and mVti1b, but not between Syntaxin 6 and the early endosomal t-SNARE Syntaxin 13. Based on these and data reported previously, we propose that Syntaxin 7/mVti1b/Syntaxin 6 may form discrete SNARE complexes with either VAMP7 or VAMPS to regulate fusion events within the late endosomal pathway and that these events may play a critical role in melanogenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new theory of hypersonic blunt-nose shock standoff, based on a compressibility coordinate transformation for inviscid flow. It embraces a wide range of nonequilibrium shock-layer chemistry and gas mixtures including ionization and freestream dissociation. An extended binary scaling property of the analysis is also demonstrated. Specific application is made here to the family of arbitrarily diluted dissociating diatomic gases, with parametric study results presented for the scaled shock standoff distance as a function of an appropriate blunt-nose region Damkohler number. Comparisons with other theories and data in the case of nitrogen are also given and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optimised gradient reversed-phase high-performance liquid chromatography electrospray ionisation mass spectrometry (LC/MS) methods, in combination with a [H-3]-brevetoxin binding assay (RLB), revealed multiple ciguatoxins in a partially purified extract of a highly toxic Lutjanus sebae (red emperor) from the Indian Ocean. Two major ciguatoxins of 1140.6 Da (I-CTX-1 and -2) and two minor ciguatoxins of 1156.6 Da (I-CTX-3 and -4) were identified. Accurate mass analysis revealed that I-CTX-1 and -2 and Caribbean C-CTX-1 had indistinguishable masses (1140.6316 Da, at 0.44 ppm resolution). Toxicity estimated from LC/MS/RLB responses indicated that I-CTX-1 and -2 were both similar to 60% the potency of Pacific ciguatoxin-1 (P-CTX-1). In contrast to ciguatoxins of the Pacific where the more oxidised ciguatoxins are more potent, I-CTX-3 and -4 were similar to 20% of P-CTX-1 potency. Interconversion in dilute acid or on storage, typical of spiroketal and hemiketal functionality found in P-CTXs and C-CTXs, respectively, was not observed to occur between I-CTX-1 and -2. The ratio of CTX-1 and -2 varied depending on the fish extract being analysed. These results suggest that I-CTX-1 and -2 may arise from separate dinoflagellate precursors that may be oxidatively biotransformed to I-CTX-3 and -4 in fish. (C) 2002 Published by Elsevier Science Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the isolation and initial characterisation of Indian Ocean ciguatoxin (I-CTX) present in toxic lipid soluble extracts isolated from ciguateric fishes collected off the Republic of Mauritius in the Indian Ocean. Following i.p. injection of this extract, mice displayed symptoms that were similar, though not identical, to those produced by Pacific and Caribbean ciguatoxins (P-CTXs and C-CTXs). Using a radiolabelled brevetoxin (PbTx) binding assay and mouse bioassay guided fractionation, I-CTX was purified by Florisil, Sephadex LH-20 and TSK HW-40S chromatography with good recovery. Isolation to purity was not possible by preparative reversed phase high-performance liquid chromatography (HPLC) due to significant losses of toxicity. However, analytical reversed phase HPLC coupled to an electrospray mass spectrometry detector identified a [M + H](+) ion at m/z 1141.58 which co-eluted with activity that displaced [3 H]-PbTx binding to rat brain. This mass corresponded to C-CTX-1, but the fragmentation pattern of I-CTX showed a different ratio of pseudo molecular and product ions. I-CTX was found to elute later than P-CTX-1 but was practically indistinguishable from C-CTX-1 on reversed phase HPLC, while the TSK HW-40S column chromatography differentiated I-CTX from the later eluting C-CTX-1. Taken together, these results indicate that I-CTX is a new ciguatoxin (CTX) responsible for ciguatera caused by reef fish in the Indian Ocean. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For the first time it was possible to observe regular quasiperiodic scintillations (QPS) in VHF radio-satellite transmissions from orbiting satellites simultaneously at short (2.1 km) and long (121 km) meridional baselines in the vicinity of a typical mid-latitude station (Brisbane; 27.5degreesS and 152.9degreesE geog. and 35.6degrees invar.lat.), using three sites (St. Lucia-S, Taringa-T in Brisbane and Boreen Pt.-B, north of Brisbane). A few pronounced quasiperiodic (QP) events were recorded showing unambiguous regular structures at the sites which made it possible to deduce a time displacement of the regular fading minimum at S, T and B. The QP structure is highly dependent on the geometry of the ray-path from a satellite to the observer which is manifested as a change of a QP event from symmetrical to non-symmetrical for stations separated by 2.1 km, and to a radical change in the structure of the event over a distance of 121 km. It is suggested the short-duration intense QP events are due to a Fresnel diffraction (or a reflection mechanism) of radio-satellite signals by a single ionospheric irregularity in a form of an ellipsoid with a large ionization gradient along the major axis. The structure of a QP event depends on the angle of viewing of the irregular blob from a radio-satellite. In view of this it is suggested that the reported variety of the ionization formation, responsible for different types of QPS, is only apparent but not real. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A análise de hidrocarbonetos por técnicas de ionização a pressão atmosférica ou ambiente continua a ser um desafio na espectrometria de massas. Normalmente, a ionização ocorre através de mecanismos de protonação e desprotonação. Para isso, as moléculas de interesse devem apresentar um grupo básico ou ácido que proporcionem a geração de íons [M+H]+ ou [M-H]-. Para superar essa limitação, um método analítico simples, fácil, rápido e poderoso foi desenvolvido com sucesso, adaptado a partir da literatura, para ionizar saturado e insaturado, linear, ramificado, e hidrocarbonetos cíclicos, bem como hidrocarbonetos poliaromáticos e heteroaromáticos presentes em frações de hidrocarbonetos e de misturas de parafina/petróleo bruto utilizando ionização química à pressão atmosférica (APCI), favorecido pela utilização de solventes alifáticos de cadeia curta em um espectrômetro de massas FT-ICR. Entre os reagentes alifáticos estudados, isoctano proporcionou os melhores resultados quando comparado com outros solventes. Além disso, foram estudados outros interferentes do processo de ionização, como concentração da solução injetada e misturas parafina/óleo, que influenciavam desde o perfil dos espectros até as principais classes de compostos identificados. O método torna possível a ionização de hidrocarbonetos pela produção de íons [M -H]+ sem ocorrência de fragmentação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – O formaldeído está enquadrado entre as 25 substâncias químicas mais abundantemente produzidas no mundo devendo-se essencialmente à sua elevada reactividade, ausência de cor, à sua pureza no formato comercial e, ainda, ao seu baixo custo. A IARC, desde 2006, classifica o formaldeído no Grupo 1 (agente carcinogénico) com base na evidência de que a exposição a formaldeído é susceptível de causar cancro nasofaríngeo em humanos. Desenvolveu-se um estudo de natureza exploratóra com o objectivo essencial de obter informação sobre a realidade da exposição profissional a formaldeído em Portugal. Igualmente, pretendeu-se conhecer a adequabilidade de uma nova metodologia de monitorização ambiental ao estudo da exposição ocupacional a formaldeído. Metodologia – Realizaram-se várias medições das concentrações de formaldeído em 7 unidades industriais e num laboratório hospitalar de anatomia patológica. As avaliações ambientais foram concretizadas com recurso a um equipamento de leitura directa que realiza a medição por Photo Ionization Detection (PID), com uma lâmpada de 11,7 eV. Resultados – No laboratório de anatomia patológica estudado foram registados valores de concentração superiores ao valor-limite de referência (0,3 ppm). Igualmente, em 2 das 7 unidades industriais estudadas foram registados valores de concentração máxima superiores a 0,3 ppm. Conclusões – Em consonância com outros estudos, o laboratório de anatomia patológica apresentou-se como o contexto ocupacional onde a exposição a formaldeído apresenta as concentrações mais elevadas. A metodologia adoptada para monitorização ambiental parece adequar-se aos objectivos da presente investigação e relacionada com o modo de actuação do agente químico em estudo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Actualmente a Tomografia Computorizada (TC) é um dos métodos de diagnóstico por imagem que tem uma maior contribuição para a dose de radiação X recebida pelos pacientes. Pretende-se com este estudo avaliar as doses praticadas em TC e contribuir para o estabelecimento de Níveis de Referência de Diagnóstico (NRD) na região da Grande Lisboa, Portugal. Foram efectuadas medições de dose em 5 equipamentos de TC multidetectores, considerando o abdómen como área anatómica de interesse. Recorreu-se a uma câmara de ionização e a um fantoma para obter o índice de dose de TC (CTDI) e o produto dose-comprimento (DLP), que permitem determinar os NRD. Estes valores foram comparados com os NRD propostos pela Guideline Europeia e com os estudos desenvolvidos em outros países, como o Reino Unido, Grécia e Taiwan. Os resultados revelaram que os valores de NRD obtidos neste estudo (16,7 mGy para o CTDIvol e 436,5 mGy·cm para o DLP) são discrepantes relativamente à Guideline Europeia (±50%), mas muito próximos relativamente aos NRD estabelecidos nos países considerados. Estes valores podem ser eventualmente explicados pelos equipamentos em análise e pela utilização de protocolos de exame adoptados pelos profissionais de Radiologia nas instituições analisadas. ABSTRACT - Nowadays Computed Tomography (CT) is one of the imaging techniques which have a large contribution to radiation dose received by patients. The purpose of this study is to evaluate CT doses and contribute to the establishment of Diagnostic Reference Levels (DRL) in Lisbon, Portugal. Dose measurements on 5 multidetector CT scanners have been performed, considering the abdomen as the anatomic region of interest. All measurements were performed using an ionization chamber and a phantom to obtain the index CT dose (CTDI) and the dose-length product (DLP), which are used to determine DRL. These values were compared not only with European reference dose values but also with DRL studies developed in other countries like United Kingdom, Greece and Taiwan. The results revealed that DRL values obtained in this study (CTDIvol is 16,7 mGy and DLP is 436,5 mGy·cm) have a higher discrepancy to European Guideline (±50%), while the DRL´s of other countries are nearest to values obtained in this study. Those differences may be eventually explained by the type of the evaluated equipments but also by the exam protocols used by the Radiology professionals on the analyzed institutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.