942 resultados para Electrical impedance tomography, Calderon problem, factorization method


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The competence evaluation promoted by the European High Education Area entails a very important methodological change that requires guiding support to help lecturers carry out this new and complex task. In this regard, the Technical University of Madrid (UPM, by its Spanish acronym) has financed a series of coordinated projects with the objective of developing a model for teaching and evaluating core competences and providing support to lecturers. This paper deals with the problem solving competence. The first step has been to elaborate a guide for teachers to provide an homogeneous way to asses this competence. This guide considers several levels of acquisition of the competence and provided the rubrics to be applied for each one. The guide has been subsequently validated with several pilot experiences. In this paper we will explain the problem-solving assessment guide for teachers and will show the pilot experiences that has been carried out. We will finally justify the validity of the method to assess the problem solving competence.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

n this work, we explain a method to characterize graphene using electrical measurements in graphene field-effect transistors (GFET) devices. Our goal is to obtain the material electronic properties from the output characteristics of one GFET device. For the previous purpose, we will need to apply a physical model that allows us to correlate the electronic behavior of a GFET with the material properties.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Esta Tesis tiene como objetivo principal el desarrollo de métodos de identificación del daño que sean robustos y fiables, enfocados a sistemas estructurales experimentales, fundamentalmente a las estructuras de hormigón armado reforzadas externamente con bandas fibras de polímeros reforzados (FRP). El modo de fallo de este tipo de sistema estructural es crítico, pues generalmente es debido a un despegue repentino y frágil de la banda del refuerzo FRP originado en grietas intermedias causadas por la flexión. La detección de este despegue en su fase inicial es fundamental para prevenir fallos futuros, que pueden ser catastróficos. Inicialmente, se lleva a cabo una revisión del método de la Impedancia Electro-Mecánica (EMI), de cara a exponer sus capacidades para la detección de daño. Una vez la tecnología apropiada es seleccionada, lo que incluye un analizador de impedancias así como novedosos sensores PZT para monitorización inteligente, se ha diseñado un procedimiento automático basado en los registros de impedancias de distintas estructuras de laboratorio. Basándonos en el hecho de que las mediciones de impedancias son posibles gracias a una colocación adecuada de una red de sensores PZT, la estimación de la presencia de daño se realiza analizando los resultados de distintos indicadores de daño obtenidos de la literatura. Para que este proceso sea automático y que no sean necesarios conocimientos previos sobre el método EMI para realizar un experimento, se ha diseñado e implementado un Interfaz Gráfico de Usuario, transformando la medición de impedancias en un proceso fácil e intuitivo. Se evalúa entonces el daño a través de los correspondientes índices de daño, intentando estimar no sólo su severidad, sino también su localización aproximada. El desarrollo de estos experimentos en cualquier estructura genera grandes cantidades de datos que han de ser procesados, y algunas veces los índices de daño no son suficientes para una evaluación completa de la integridad de una estructura. En la mayoría de los casos se pueden encontrar patrones de daño en los datos, pero no se tiene información a priori del estado de la estructura. En este punto, se ha hecho una importante investigación en técnicas de reconocimiento de patrones particularmente en aprendizaje no supervisado, encontrando aplicaciones interesantes en el campo de la medicina. De ahí surge una idea creativa e innovadora: detectar y seguir la evolución del daño en distintas estructuras como si se tratase de un cáncer propagándose por el cuerpo humano. En ese sentido, las lecturas de impedancias se emplean como información intrínseca de la salud de la propia estructura, de forma que se pueden aplicar las mismas técnicas que las empleadas en la investigación del cáncer. En este caso, se ha aplicado un algoritmo de clasificación jerárquica dado que ilustra además la clasificación de los datos de forma gráfica, incluyendo información cualitativa y cuantitativa sobre el daño. Se ha investigado la efectividad de este procedimiento a través de tres estructuras de laboratorio, como son una viga de aluminio, una unión atornillada de aluminio y un bloque de hormigón reforzado con FRP. La primera ayuda a mostrar la efectividad del método en sencillos escenarios de daño simple y múltiple, de forma que las conclusiones extraídas se aplican sobre los otros dos, diseñados para simular condiciones de despegue en distintas estructuras. Demostrada la efectividad del método de clasificación jerárquica de lecturas de impedancias, se aplica el procedimiento sobre las estructuras de hormigón armado reforzadas con bandas de FRP objeto de esta tesis, detectando y clasificando cada estado de daño. Finalmente, y como alternativa al anterior procedimiento, se propone un método para la monitorización continua de la interfase FRP-Hormigón, a través de una red de sensores FBG permanentemente instalados en dicha interfase. De esta forma, se obtienen medidas de deformación de la interfase en condiciones de carga continua, para ser implementadas en un modelo de optimización multiobjetivo, cuya solución se haya por medio de una expansión multiobjetivo del método Particle Swarm Optimization (PSO). La fiabilidad de este último método de detección se investiga a través de sendos ejemplos tanto numéricos como experimentales. ABSTRACT This thesis aims to develop robust and reliable damage identification methods focused on experimental structural systems, in particular Reinforced Concrete (RC) structures externally strengthened with Fiber Reinforced Polymers (FRP) strips. The failure mode of this type of structural system is critical, since it is usually due to sudden and brittle debonding of the FRP reinforcement originating from intermediate flexural cracks. Detection of the debonding in its initial stage is essential thus to prevent future failure, which might be catastrophic. Initially, a revision of the Electro-Mechanical Impedance (EMI) method is carried out, in order to expose its capabilities for local damage detection. Once the appropriate technology is selected, which includes impedance analyzer as well as novel PZT sensors for smart monitoring, an automated procedure has been design based on the impedance signatures of several lab-scale structures. On the basis that capturing impedance measurements is possible thanks to an adequately deployed PZT sensor network, the estimation of damage presence is done by analyzing the results of different damage indices obtained from the literature. In order to make this process automatic so that it is not necessary a priori knowledge of the EMI method to carry out an experimental test, a Graphical User Interface has been designed, turning the impedance measurements into an easy and intuitive procedure. Damage is then assessed through the analysis of the corresponding damage indices, trying to estimate not only the damage severity, but also its approximate location. The development of these tests on any kind of structure generates large amounts of data to be processed, and sometimes the information provided by damage indices is not enough to achieve a complete analysis of the structural health condition. In most of the cases, some damage patterns can be found in the data, but none a priori knowledge of the health condition is given for any structure. At this point, an important research on pattern recognition techniques has been carried out, particularly on unsupervised learning techniques, finding interesting applications in the medicine field. From this investigation, a creative and innovative idea arose: to detect and track the evolution of damage in different structures, as if it were a cancer propagating through a human body. In that sense, the impedance signatures are used to give intrinsic information of the health condition of the structure, so that the same clustering algorithms applied in the cancer research can be applied to the problem addressed in this dissertation. Hierarchical clustering is then applied since it also provides a graphical display of the clustered data, including quantitative and qualitative information about damage. The performance of this approach is firstly investigated using three lab-scale structures, such as a simple aluminium beam, a bolt-jointed aluminium beam and an FRP-strengthened concrete specimen. The first one shows the performance of the method on simple single and multiple damage scenarios, so that the first conclusions can be extracted and applied to the other two experimental tests, which are designed to simulate a debonding condition on different structures. Once the performance of the impedance-based hierarchical clustering method is proven to be successful, it is then applied to the structural system studied in this dissertation, the RC structures externally strengthened with FRP strips, where the debonding failure in the interface between the FRP and the concrete is successfully detected and classified, proving thus the feasibility of this method. Finally, as an alternative to the previous approach, a continuous monitoring procedure of the FRP-Concrete interface is proposed, based on an FBGsensors Network permanently deployed within that interface. In this way, strain measurements can be obtained under controlled loading conditions, and then they are used in order to implement a multi-objective model updating method solved by a multi-objective expansion of the Particle Swarm Optimization (PSO) method. The feasibility of this last proposal is investigated and successfully proven on both numerical and experimental RC beams strengthened with FRP.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

I. GENERALIDADES 1.1. Introducción Entre los diversos tipos de perturbaciones eléctricas, los huecos de tensión son considerados el problema de calidad de suministro más frecuente en los sistemas eléctricos. Este fenómeno es originado por un aumento extremo de la corriente en el sistema, causado principalmente por cortocircuitos o maniobras inadecuadas en la red. Este tipo de perturbación eléctrica está caracterizado básicamente por dos parámetros: tensión residual y duración. Típicamente, se considera que el hueco se produce cuando la tensión residual alcanza en alguna de las fases un valor entre 0.01 a 0.9 pu y tiene una duración de hasta 60 segundos. Para un usuario final, el efecto más relevante de un hueco de tensión es la interrupción o alteración de la operación de sus equipos, siendo los dispositivos de naturaleza electrónica los principalmente afectados (p. ej. ordenador, variador de velocidad, autómata programable, relé, etc.). Debido al auge tecnológico de las últimas décadas y a la búsqueda constante de automatización de los procesos productivos, el uso de componentes electrónicos resulta indispensable en la actualidad. Este hecho, lleva a que los efectos de los huecos de tensión sean más evidentes para el usuario final, provocando que su nivel de exigencia de la calidad de energía suministrada sea cada vez mayor. De forma general, el estudio de los huecos de tensión suele ser abordado bajo dos enfoques: en la carga o en la red. Desde el punto de vista de la carga, se requiere conocer las características de sensibilidad de los equipos para modelar su respuesta ante variaciones súbitas de la tensión del suministro eléctrico. Desde la perspectiva de la red, se busca estimar u obtener información adecuada que permita caracterizar su comportamiento en términos de huecos de tensión. En esta tesis, el trabajo presentado se encuadra en el segundo aspecto, es decir, en el modelado y estimación de la respuesta de un sistema eléctrico de potencia ante los huecos de tensión. 1.2. Planteamiento del problema A pesar de que los huecos de tensión son el problema de calidad de suministro más frecuente en las redes, hasta la actualidad resulta complejo poder analizar de forma adecuada este tipo de perturbación para muchas compañías del sector eléctrico. Entre las razones más comunes se tienen: - El tiempo de monitorización puede llegar a ser de varios años para conseguir una muestra de registros de huecos estadísticamente válida. - La limitación de recursos económicos para la adquisición e instalación de equipos de monitorización de huecos. - El elevado coste operativo que implica el análisis de los datos de los medidores de huecos de tensión instalados. - La restricción que tienen los datos de calidad de energía de las compañías eléctricas. Es decir, ante la carencia de datos que permitan analizar con mayor detalle los huecos de tensión, es de interés de las compañías eléctricas y la academia poder crear métodos fiables que permitan profundizar en el estudio, estimación y supervisión de este fenómeno electromagnético. Los huecos de tensión, al ser principalmente originados por eventos fortuitos como los cortocircuitos, son el resultado de diversas variables exógenas como: (i) la ubicación de la falta, (ii) la impedancia del material de contacto, (iii) el tipo de fallo, (iv) la localización del fallo en la red, (v) la duración del evento, etc. Es decir, para plantear de forma adecuada cualquier modelo teórico sobre los huecos de tensión, se requeriría representar esta incertidumbre combinada de las variables para proveer métodos realistas y, por ende, fiables para los usuarios. 1.3. Objetivo La presente tesis ha tenido como objetivo el desarrollo diversos métodos estocásticos para el estudio, estimación y supervisión de los huecos de tensión en los sistemas eléctricos de potencia. De forma específica, se ha profundizado en los siguientes ámbitos: - En el modelado realista de las variables que influyen en la caracterización de los huecos. Esto es, en esta Tesis se ha propuesto un método que permite representar de forma verosímil su cuantificación y aleatoriedad en el tiempo empleando distribuciones de probabilidad paramétricas. A partir de ello, se ha creado una herramienta informática que permite estimar la severidad de los huecos de tensión en un sistema eléctrico genérico. - Se ha analizado la influencia la influencia de las variables de entrada en la estimación de los huecos de tensión. En este caso, el estudio se ha enfocado en las variables de mayor divergencia en su caracterización de las propuestas existentes. - Se ha desarrollado un método que permite estima el número de huecos de tensión de una zona sin monitorización a través de la información de un conjunto limitado de medidas de un sistema eléctrico. Para ello, se aplican los principios de la estadística Bayesiana, estimando el número de huecos de tensión más probable de un emplazamiento basándose en los registros de huecos de otros nudos de la red. - Plantear una estrategia para optimizar la monitorización de los huecos de tensión en un sistema eléctrico. Es decir, garantizar una supervisión del sistema a través de un número de medidores menor que el número de nudos de la red. II. ESTRUCTURA DE LA TESIS Para plantear las propuestas anteriormente indicadas, la presente Tesis se ha estructurado en seis capítulos. A continuación, se describen brevemente los mismos. A manera de capítulo introductorio, en el capítulo 1, se realiza una descripción del planteamiento y estructura de la presente tesis. Esto es, se da una visión amplia de la problemática a tratar, además de describir el alcance de cada capítulo de la misma. En el capítulo 2, se presenta una breve descripción de los fundamentos y conceptos generales de los huecos de tensión. Los mismos, buscan brindar al lector de una mejor comprensión de los términos e indicadores más empleados en el análisis de severidad de los huecos de tensión en las redes eléctricas. Asimismo, a manera de antecedente, se presenta un resumen de las principales características de las técnicas o métodos existentes aplicados en la predicción y monitorización óptima de los huecos de tensión. En el capítulo 3, se busca fundamentalmente conocer la importancia de las variables que determinen la frecuencia o severidad de los huecos de tensión. Para ello, se ha implementado una herramienta de estimación de huecos de tensión que, a través de un conjunto predeterminado de experimentos mediante la técnica denominada Diseño de experimentos, analiza la importancia de la parametrización de las variables de entrada del modelo. Su análisis, es realizado mediante la técnica de análisis de la varianza (ANOVA), la cual permite establecer con rigor matemático si la caracterización de una determinada variable afecta o no la respuesta del sistema en términos de los huecos de tensión. En el capítulo 4, se propone una metodología que permite predecir la severidad de los huecos de tensión de todo el sistema a partir de los registros de huecos de un conjunto reducido de nudos de dicha red. Para ello, se emplea el teorema de probabilidad condicional de Bayes, el cual calcula las medidas más probables de todo el sistema a partir de la información proporcionada por los medidores de huecos instalados. Asimismo, en este capítulo se revela una importante propiedad de los huecos de tensión, como es la correlación del número de eventos de huecos de tensión en diversas zonas de las redes eléctricas. En el capítulo 5, se desarrollan dos métodos de localización óptima de medidores de huecos de tensión. El primero, que es una evolución metodológica del criterio de observabilidad; aportando en el realismo de la pseudo-monitorización de los huecos de tensión con la que se calcula el conjunto óptimo de medidores y, por ende, en la fiabilidad del método. Como una propuesta alternativa, se emplea la propiedad de correlación de los eventos de huecos de tensión de una red para plantear un método que permita establecer la severidad de los huecos de todo el sistema a partir de una monitorización parcial de dicha red. Finalmente, en el capítulo 6, se realiza una breve descripción de las principales aportaciones de los estudios realizados en esta tesis. Adicionalmente, se describen diversos temas a desarrollar en futuros trabajos. III. RESULTADOS En base a las pruebas realizadas en las tres redes planteadas; dos redes de prueba IEEE de 24 y 118 nudos (IEEE-24 e IEEE-118), además del sistema eléctrico de la República del Ecuador de 357 nudos (EC-357), se describen los siguientes puntos como las observaciones más relevantes: A. Estimación de huecos de tensión en ausencia de medidas: Se implementa un método estocástico de estimación de huecos de tensión denominado PEHT, el cual representa con mayor realismo la simulación de los eventos de huecos de un sistema a largo plazo. Esta primera propuesta de la tesis, es considerada como un paso clave para el desarrollo de futuros métodos del presente trabajo, ya que permite emular de forma fiable los registros de huecos de tensión a largo plazo en una red genérica. Entre las novedades más relevantes del mencionado Programa de Estimación de Huecos de Tensión (PEHT) se tienen: - Considerar el efecto combinado de cinco variables aleatorias de entrada para simular los eventos de huecos de tensión en una pseudo-monitorización a largo plazo. Las variables de entrada modeladas en la caracterización de los huecos de tensión en el PEHT son: (i) coeficiente de fallo, (ii) impedancia de fallo, (iii) tipo de fallo, (iv) localización del fallo y (v) duración. - El modelado estocástico de las variables de entrada impedancia de fallo y duración en la caracterización de los eventos de huecos de tensión. Para la parametrización de las variables mencionadas, se realizó un estudio detallado del comportamiento real de las mismas en los sistemas eléctricos. Asimismo, se define la función estadística que mejor representa la naturaleza aleatoria de cada variable. - Considerar como variables de salida del PEHT a indicadores de severidad de huecos de uso común en las normativas, como es el caso de los índices: SARFI-X, SARFI-Curve, etc. B. Análisis de sensibilidad de los huecos de tensión: Se presenta un estudio causa-efecto (análisis de sensibilidad) de las variables de entrada de mayor divergencia en su parametrización entre las referencias relacionadas a la estimación de los huecos de tensión en redes eléctricas. De forma específica, se profundiza en el estudio de la influencia de la parametrización de las variables coeficiente de fallo e impedancia de fallo en la predicción de los huecos de tensión. A continuación un resumen de las conclusiones más destacables: - La precisión de la variable de entrada coeficiente de fallo se muestra como un parámetro no influyente en la estimación del número de huecos de tensión (SARFI-90 y SARFI-70) a largo plazo. Es decir, no se requiere de una alta precisión del dato tasa de fallo de los elementos del sistema para obtener una adecuada estimación de los huecos de tensión. - La parametrización de la variable impedancia de fallo se muestra como un factor muy sensible en la estimación de la severidad de los huecos de tensión. Por ejemplo, al aumentar el valor medio de esta variable aleatoria, se disminuye considerablemente la severidad reportada de los huecos en la red. Por otra parte, al evaluar el parámetro desviación típica de la impedancia de fallo, se observa una relación directamente proporcional de este parámetro con la severidad de los huecos de tensión de la red. Esto es, al aumentar la desviación típica de la impedancia de fallo, se evidencia un aumento de la media y de la variación interanual de los eventos SARFI-90 y SARFI-70. - En base al análisis de sensibilidad desarrollado en la variable impedancia de fallo, se considera muy cuestionable la fiabilidad de los métodos de estimación de huecos de tensión que omiten su efecto en el modelo planteado. C. Estimación de huecos de tensión en base a la información de una monitorización parcial de la red: Se desarrolla un método que emplea los registros de una red parcialmente monitorizada para determinar la severidad de los huecos de todo el sistema eléctrico. A partir de los casos de estudio realizados, se observa que el método implementado (PEHT+MP) posee las siguientes características: - La metodología propuesta en el PEHT+MP combina la teoría clásica de cortocircuitos con diversas técnicas estadísticas para estimar, a partir de los datos de los medidores de huecos instalados, las medidas de huecos de los nudos sin monitorización de una red genérica. - El proceso de estimación de los huecos de tensión de la zona no monitorizada de la red se fundamenta en la aplicación del teorema de probabilidad condicional de Bayes. Es decir, en base a los datos observados (los registros de los nudos monitorizados), el PEHT+MP calcula de forma probabilística la severidad de los huecos de los nudos sin monitorización del sistema. Entre las partes claves del procedimiento propuesto se tienen los siguientes puntos: (i) la creación de una base de datos realista de huecos de tensión a través del Programa de Estimación de Huecos de Tensión (PEHT) propuesto en el capítulo anterior; y, (ii) el criterio de máxima verosimilitud empleado para estimar las medidas de huecos de los nudos sin monitorización de la red evaluada. - Las predicciones de medidas de huecos de tensión del PEHT+MP se ven potenciadas por la propiedad de correlación de los huecos de tensión en diversas zonas de un sistema eléctrico. Esta característica intrínseca de las redes eléctricas limita de forma significativa la respuesta de las zonas fuertemente correlacionadas del sistema ante un eventual hueco de tensión. Como el PEHT+MP está basado en principios probabilísticos, la reducción del rango de las posibles medidas de huecos se ve reflejado en una mejor predicción de las medidas de huecos de la zona no monitorizada. - Con los datos de un conjunto de medidores relativamente pequeño del sistema, es posible obtener estimaciones precisas (error nulo) de la severidad de los huecos de la zona sin monitorizar en las tres redes estudiadas. - El PEHT+MP se puede aplicar a diversos tipos de indicadores de severidad de los huecos de tensión, como es el caso de los índices: SARFI-X, SARFI-Curve, SEI, etc. D. Localización óptima de medidores de huecos de tensión: Se plantean dos métodos para ubicar de forma estratégica al sistema de monitorización de huecos en una red genérica. La primera propuesta, que es una evolución metodológica de la localización óptima de medidores de huecos basada en el criterio de observabilidad (LOM+OBS); y, como segunda propuesta, un método que determina la localización de los medidores de huecos según el criterio del área de correlación (LOM+COR). Cada método de localización óptima de medidores propuesto tiene un objetivo concreto. En el caso del LOM+OBS, la finalidad del método es determinar el conjunto óptimo de medidores que permita registrar todos los fallos que originen huecos de tensión en la red. Por otro lado, en el método LOM+COR se persigue definir un sistema óptimo de medidores que, mediante la aplicación del PEHT+MP (implementado en el capítulo anterior), sea posible estimar de forma precisa las medidas de huecos de tensión de todo el sistema evaluado. A partir del desarrollo de los casos de estudio de los citados métodos de localización óptima de medidores en las tres redes planteadas, se describen a continuación las observaciones más relevantes: - Como la generación de pseudo-medidas de huecos de tensión de los métodos de localización óptima de medidores (LOM+OBS y LOM+COR) se obtienen mediante la aplicación del algoritmo PEHT, la formulación del criterio de optimización se realiza en base a una pseudo-monitorización realista, la cual considera la naturaleza aleatoria de los huecos de tensión a través de las cinco variables estocásticas modeladas en el PEHT. Esta característica de la base de datos de pseudo-medidas de huecos de los métodos LOM+OBS y LOM+COR brinda una mayor fiabilidad del conjunto óptimo de medidores calculado respecto a otros métodos similares en la bibliografía. - El conjunto óptimo de medidores se determina según la necesidad del operador de la red. Esto es, si el objetivo es registrar todos los fallos que originen huecos de tensión en el sistema, se emplea el criterio de observabilidad en la localización óptima de medidores de huecos. Por otra parte, si se plantea definir un sistema de monitorización que permita establecer la severidad de los huecos de tensión de todo el sistema en base a los datos de un conjunto reducido de medidores de huecos, el criterio de correlación resultaría el adecuado. De forma específica, en el caso del método LOM+OBS, basado en el criterio de observabilidad, se evidenciaron las siguientes propiedades en los casos de estudio realizados: - Al aumentar el tamaño de la red, se observa la tendencia de disminuir el porcentaje de nudos monitorizados de dicho sistema. Por ejemplo, para monitorizar los fallos que originan huecos en la red IEEE-24, se requiere monitorizar el 100\% de los nudos del sistema. En el caso de las redes IEEE-118 y EC-357, el método LOM+OBS determina que con la monitorización de un 89.5% y 65.3% del sistema, respectivamente, se cumpliría con el criterio de observabilidad del método. - El método LOM+OBS permite calcular la probabilidad de utilización del conjunto óptimo de medidores a largo plazo, estableciendo así un criterio de la relevancia que tiene cada medidor considerado como óptimo en la red. Con ello, se puede determinar el nivel de precisión u observabilidad (100%, 95%, etc.) con el cual se detectarían los fallos que generan huecos en la red estudiada. Esto es, al aumentar el nivel de precisión de detección de los fallos que originan huecos, se espera que aumente el número de medidores requeridos en el conjunto óptimo de medidores calculado. - El método LOM+OBS se evidencia como una técnica aplicable a todo tipo de sistema eléctrico (radial o mallado), el cual garantiza la detección de los fallos que originan huecos de tensión en un sistema según el nivel de observabilidad planteado. En el caso del método de localización óptima de medidores basado en el criterio del área de correlación (LOM+COR), las diversas pruebas realizadas evidenciaron las siguientes conclusiones: - El procedimiento del método LOM+COR combina los métodos de estimación de huecos de tensión de capítulos anteriores (PEHT y PEHT+MP) con técnicas de optimización lineal para definir la localización óptima de los medidores de huecos de tensión de una red. Esto es, se emplea el PEHT para generar los pseudo-registros de huecos de tensión, y, en base al criterio planteado de optimización (área de correlación), el LOM+COR formula y calcula analíticamente el conjunto óptimo de medidores de la red a largo plazo. A partir de la información registrada por este conjunto óptimo de medidores de huecos, se garantizaría una predicción precisa de la severidad de los huecos de tensión de todos los nudos del sistema con el PEHT+MP. - El método LOM+COR requiere un porcentaje relativamente reducido de nudos del sistema para cumplir con las condiciones de optimización establecidas en el criterio del área de correlación. Por ejemplo, en el caso del número total de huecos (SARFI-90) de las redes IEEE-24, IEEE-118 y EC-357, se calculó un conjunto óptimo de 9, 12 y 17 medidores de huecos, respectivamente. Es decir, solamente se requeriría monitorizar el 38\%, 10\% y 5\% de los sistemas indicados para supervisar los eventos SARFI-90 en toda la red. - El método LOM+COR se muestra como un procedimiento de optimización versátil, el cual permite reducir la dimensión del sistema de monitorización de huecos de redes eléctricas tanto radiales como malladas. Por sus características, este método de localización óptima permite emular una monitorización integral del sistema a través de los registros de un conjunto pequeño de monitores. Por ello, este nuevo método de optimización de medidores sería aplicable a operadores de redes que busquen disminuir los costes de instalación y operación del sistema de monitorización de los huecos de tensión. ABSTRACT I. GENERALITIES 1.1. Introduction Among the various types of electrical disturbances, voltage sags are considered the most common quality problem in power systems. This phenomenon is caused by an extreme increase of the current in the network, primarily caused by short-circuits or inadequate maneuvers in the system. This type of electrical disturbance is basically characterized by two parameters: residual voltage and duration. Typically, voltage sags occur when the residual voltage, in some phases, reaches a value between 0.01 to 0.9 pu and lasts up to 60 seconds. To an end user, the most important effect of a voltage sags is the interruption or alteration of their equipment operation, with electronic devices the most affected (e.g. computer, drive controller, PLC, relay, etc.). Due to the technology boom of recent decades and the constant search for automating production processes, the use of electronic components is essential today. This fact makes the effects of voltage sags more noticeable to the end user, causing the level of demand for a quality energy supply to be increased. In general, the study of voltage sags is usually approached from one of two aspects: the load or the network. From the point of view of the load, it is necessary to know the sensitivity characteristics of the equipment to model their response to sudden changes in power supply voltage. From the perspective of the network, the goal is to estimate or obtain adequate information to characterize the network behavior in terms of voltage sags. In this thesis, the work presented fits into the second aspect; that is, in the modeling and estimation of the response of a power system to voltage sag events. 1.2. Problem Statement Although voltage sags are the most frequent quality supply problem in electrical networks, thistype of disturbance remains complex and challenging to analyze properly. Among the most common reasons for this difficulty are: - The sag monitoring time, because it can take up to several years to get a statistically valid sample. - The limitation of funds for the acquisition and installation of sag monitoring equipment. - The high operating costs involved in the analysis of the voltage sag data from the installed monitors. - The restrictions that electrical companies have with the registered power quality data. That is, given the lack of data to further voltage sag analysis, it is of interest to electrical utilities and researchers to create reliable methods to deepen the study, estimation and monitoring of this electromagnetic phenomenon. Voltage sags, being mainly caused by random events such as short-circuits, are the result of various exogenous variables such as: (i) the number of faults of a system element, (ii) the impedance of the contact material, (iii) the fault type, (iv) the fault location, (v) the duration of the event, etc. That is, to properly raise any theoretical model of voltage sags, it is necessary to represent the combined uncertainty of variables to provide realistic methods that are reliable for users. 1.3. Objective This Thesis has been aimed at developing various stochastic methods for the study, estimation and monitoring of voltage sags in electrical power systems. Specifically, it has deepened the research in the following areas: - This research furthers knowledge in the realistic modeling of the variables that influence sag characterization. This thesis proposes a method to credibly represent the quantification and randomness of the sags in time by using parametric probability distributions. From this, a software tool was created to estimate the severity of voltage sags in a generic power system. - This research also analyzes the influence of the input variables in the estimation of voltage sags. In this case, the study has focused on the variables of greatest divergence in their characterization of the existing proposals. - A method was developed to estimate the number of voltage sags of an area without monitoring through the information of a limited set of sag monitors in an electrical system. To this end, the principles of Bayesian statistics are applied, estimating the number of sags most likely to happen in a system busbar based in records of other sag network busbars. - A strategy was developed to optimize the monitorization of voltage sags on a power system. Its purpose is to ensure the monitoring of the system through a number of monitors lower than the number of busbars of the network assessed. II. THESIS STRUCTURE To describe in detail the aforementioned proposals, this Thesis has been structured into six chapters. Below is are brief descriptions of them: As an introductory chapter, Chapter 1, provides a description of the approach and structure of this thesis. It presents a wide view of the problem to be treated, in addition to the description of the scope of each chapter. In Chapter 2, a brief description of the fundamental and general concepts of voltage sags is presented to provide to the reader a better understanding of the terms and indicators used in the severity analysis of voltage sags in power networks. Also, by way of background, a summary of the main features of existing techniques or methods used in the prediction and optimal monitoring of voltage sags is also presented. Chapter 3 essentially seeks to know the importance of the variables that determine the frequency or severity of voltage sags. To do this, a tool to estimate voltage sags is implemented that, through a predetermined set of experiments using the technique called Design of Experiments, discusses the importance of the parameters of the input variables of the model. Its analysis is interpreted by using the technique of analysis of variance (ANOVA), which provides mathematical rigor to establish whether the characterization of a particular variable affects the system response in terms of voltage sags or not. In Chapter 4, a methodology to predict the severity of voltage sags of an entire system through the sag logs of a reduced set of monitored busbars is proposed. For this, the Bayes conditional probability theorem is used, which calculates the most likely sag severity of the entire system from the information provided by the installed monitors. Also, in this chapter an important property of voltage sags is revealed, as is the correlation of the voltage sags events in several zones of a power system. In Chapter 5, two methods of optimal location of voltage sag monitors are developed. The first one is a methodological development of the observability criteria; it contributes to the realism of the sag pseudo-monitoring with which the optimal set of sag monitors is calculated and, therefore, to the reliability of the proposed method. As an alternative proposal, the correlation property of the sag events of a network is used to raise a method that establishes the sag severity of the entire system from a partial monitoring of the network. Finally, in Chapter 6, a brief description of the main contributions of the studies in this Thesis is detailed. Additionally, various themes to be developed in future works are described. III. RESULTS. Based on tests on the three networks presented, two IEEE test networks of 24 and 118 busbars (IEEE-24 and IEEE-118) and the electrical system of the Republic of Ecuador (EC-357), the following points present the most important observations: A. Estimation of voltage sags in the absence of measures: A stochastic estimation method of voltage sags, called PEHT, is implemented to represent with greater realism the long-term simulation of voltage sags events in a system. This first proposal of this thesis is considered a key step for the development of future methods of this work, as it emulates in a reliable manner the voltage sag long-term records in a generic network. Among the main innovations of this voltage sag estimation method are the following: - Consideration of the combined effect of five random input variables to simulate the events of voltage sags in long-term monitoring is included. The input variables modeled in the characterization of voltage sags on the PEHT are as follows: (i) fault coefficient, (ii) fault impedance, (iii) type of fault, (iv) location of the fault, and (v) fault duration. - Also included is the stochastic modeling of the input variables of fault impedance and duration in the characterization of the events of voltage sags. For the parameterization of these variables, a detailed study of the real behavior in power systems is developed. Also, the statistical function best suited to the random nature of each variable is defined. - Consideration of sag severity indicators used in standards as PEHT output variables, including such as indices as SARFI-X, SARFI-Curve, etc. B. Sensitivity analysis of voltage sags: A cause-effect study (sensitivity analysis) of the input variables of greatest divergence between reference parameterization related to the estimation of voltage sags in electrical networks is presented. Specifically, it delves into the study of the influence of the parameterization of the variables fault coefficient and fault impedance in the voltage sag estimation. Below is a summary of the most notable observations: - The accuracy of the input variable fault coefficient is shown as a non-influential parameter in the long-term estimation of the number of voltage sags (SARFI-90 and SARFI-70). That is, it does not require a high accuracy of the fault rate data of system elements for a proper voltage sag estimation. - The parameterization of the variable fault impedance is shown to be a very sensitive factor in the estimation of the voltage sag severity. For example, by increasing the average value of this random variable, the reported sag severity in the network significantly decreases. Moreover, in assessing the standard deviation of the fault impedance parameter, a direct relationship of this parameter with the voltage sag severity of the network is observed. That is, by increasing the fault impedance standard deviation, an increase of the average and the interannual variation of the SARFI-90 and SARFI-70 events is evidenced. - Based on the sensitivity analysis developed in the variable fault impedance, the omission of this variable in the voltage sag estimation would significantly call into question the reliability of the responses obtained. C. Voltage sag estimation from the information of a network partially monitored: A method that uses the voltage sag records of a partially monitored network for the sag estimation of all the power system is developed. From the case studies performed, it is observed that the method implemented (PEHT+MP) has the following characteristics: - The methodology proposed in the PEHT+MP combines the classical short-circuit theory with several statistical techniques to estimate, from data the of the installed sag meters, the sag measurements of unmonitored busbars of a generic power network. - The estimation process of voltage sags of the unmonitored zone of the network is based on the application of the conditional probability theorem of Bayes. That is, based on the observed data (monitored busbars records), the PEHT+MP calculates probabilistically the sag severity at unmonitored system busbars. Among the key parts of the proposed procedure are the following: (i) the creation of a realistic data base of voltage sags through of the sag estimation program (PEHT); and, (ii) the maximum likelihood criterion used to estimate the sag indices of system busbars without monitoring. - The voltage sag measurement estimations of PEHT+MP are potentiated by the correlation property of the sag events in power systems. This inherent characteristic of networks significantly limits the response of strongly correlated system zones to a possible voltage sag. As the PEHT+MP is based on probabilistic principles, a reduction of the range of possible sag measurements is reflected in a better sag estimation of the unmonitored area of the power system. - From the data of a set of monitors representing a relatively small portion of the system, to obtain accurate estimations (null error) of the sag severity zones without monitoring is feasible in the three networks studied. - The PEHT+MP can be applied to several types of sag indices, such as: SARFI-X, SARFI-Curve, SEI, etc. D. Optimal location of voltage sag monitors in power systems: Two methods for strategically locating the sag monitoring system are implemented for a generic network. The first proposal is a methodological development of the optimal location of sag monitors based on the observability criterion (LOM + OBS); the second proposal is a method that determines the sag monitor location according to the correlation area criterion (LOM+COR). Each proposed method of optimal location of sag monitors has a specific goal. In the case of LOM+OBS, the purpose of the method is to determine the optimal set of sag monitors to record all faults that originate voltage sags in the network. On the other hand, the LOM+COR method attempts to define the optimal location of sag monitors to estimate the sag indices in all the assessed network with the PEHT+MP application. From the development of the case studies of these methods of optimal location of sag monitors in the three networks raised, the most relevant observations are described below: - As the generation of voltage sag pseudo-measurements of the optimal location methods (LOM+OBS and LOM+COR) are obtained by applying the algorithm PEHT, the formulation of the optimization criterion is performed based on a realistic sag pseudo-monitoring, which considers the random nature of voltage sags through the five stochastic variables modeled in PEHT. This feature of the database of sag pseudo-measurements of the LOM+OBS and LOM+COR methods provides a greater reliability of the optimal set of monitors calculated when compared to similar methods in the bibliography. - The optimal set of sag monitors is determined by the network operator need. That is, if the goal is to record all faults that originate from voltage sags in the system, the observability criterion is used to determine the optimal location of sag monitors (LOM+OBS). Moreover, if the objective is to define a monitoring system that allows establishing the sag severity of the system from taken from information based on a limited set of sag monitors, the correlation area criterion would be appropriate (LOM+COR). Specifically, in the case of the LOM+OBS method (based on the observability criterion), the following properties were observed in the case studies: - By increasing the size of the network, there was observed a reduction in the percentage of monitored system busbars required. For example, to monitor all the faults which cause sags in the IEEE-24 network, then 100% of the system busbars are required for monitoring. In the case of the IEEE-118 and EC-357 networks, the method LOM+OBS determines that with monitoring 89.5 % and 65.3 % of the system, respectively, the observability criterion of the method would be fulfilled. - The LOM+OBS method calculates the probability of using the optimal set of sag monitors in the long term, establishing a relevance criterion of each sag monitor considered as optimal in the network. With this, the level of accuracy or observability (100%, 95%, etc.) can be determined, with which the faults that caused sags in the studied network are detected. That is, when the accuracy level for detecting faults that cause sags in the system is increased, a larger number of sag monitors is expected when calculating the optimal set of monitors. - The LOM + OBS method is demonstrated to be a technique applicable to any type of electrical system (radial or mesh), ensuring the detection of faults that cause voltage sags in a system according to the observability level raised. In the case of the optimal localization of sag monitors based on the criterion of correlation area (LOM+COR), several tests showed the following conclusions: - The procedure of LOM+COR method combines the implemented algorithms of voltage sag estimation (PEHT and PEHT+MP) with linear optimization techniques to define the optimal location of the sag monitors in a network. That is, the PEHT is used to generate the voltage sag pseudo-records, and, from the proposed optimization criterion (correlation area), the LOM+COR formulates and analytically calculates the optimal set of sag monitors of the network in the long term. From the information recorded by the optimal set of sag monitors, an accurate prediction of the voltage sag severity at all the busbars of the system is guaranteed with the PEHT+MP. - The LOM + COR method is shown to be a versatile optimization procedure, which reduces the size of the sag monitoring system both at radial as meshed grids. Due to its characteristics, this optimal location method allows emulation of complete system sag monitoring through the records of a small optimal set of sag monitors. Therefore, this new optimization method would be applicable to network operators that looks to reduce the installation and operation costs of the voltage sag monitoring system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Los objetivos de esta tesis fueron 1) obtener y validar ecuaciones de predicción para determinar in vivo la composición corporal y de la canal de conejos en crecimiento de 25 a 77 días de vida utilizando la técnica de la Impedancia Bioeléctrica (BIA), y 2) evaluar su aplicación para determinar diferencias en la composición corporal y de la canal, así como la retención de nutrientes de animales alimentados con diferentes fuentes y niveles de grasa. El primer estudio se realizó para determinar y después validar, usando datos independientes, las ecuaciones de predicción obtenidas para determinar in vivo la composición corporal de los conejos en crecimiento. Se utilizaron 150 conejos a 5 edades distintas (25, 35, 49, 63 y 77 días de vida), con un rango de pesos entre 231 y 3138 g. Para determinar los valores de resistencia (Rs,) and reactancia (Xc,) se usó un terminal (Model BIA-101, RJL Systems, Detroit, MI USA) con cuatro electrodos. Igualmente se registró la distancia entre electrodos internos (D), la longitud corporal (L) y el peso vivo (PV) de cada animal. En cada edad, los animales fueron molidos y congelados (-20 ºC) para su posterior análisis químico (MS, grasa, proteína, cenizas y EB). El contenido en grasa y energía de los animales se incrementó, mientras que los contenidos en proteína, cenizas y agua de los animales disminuyeron con la edad. Los valores medios de Rs, Xc, impedancia (Z), L y D fueron 83.5 ± 23.1 , 18.2 ± 3.8 , 85.6 ± 22.9 , 30.6 ± 6.9 cm y 10.8 ± 3.1 cm. Se realizó un análisis de regresión lineal múltiple para determinar las ecuaciones de predicción, utilizando los valores de PV, L and Z como variables independientes. Las ecuaciones obtenidas para estimar los contenidos en agua (g), PB (g), grasa (g), cenizas (g) and EB (MJ) tuvieron un coeficiente de determinación de (R2) de 0.99, 0.99, 0.97, 0.98 y 0.99, y los errores medios de predicción relativos (EMPR) fueron: 2.79, 6.15, 24.3, 15.2 y 10.6%, respectivamente. Cuando el contenido en agua se expresó como porcentaje, los valores de R2 y EMPR fueron 0.85 and 2.30%, respectivamente. Al predecir los contenidos en proteína (%MS), grasa (%MS), cenizas (%MS) y energía (kJ/100 g MS), se obtuvieron valores de 0.79, 0.83, 0.71 y 0.86 para R2, y 5.04, 18.9, 12.0 y 3.19% para EMPR. La reactancia estuvo negativamente correlacionada con el contenido en agua, cenizas y PB (r = -0.32, P < 0.0001; r = -0.20, P < 0.05; r = -0.26, P < 0.01) y positivamente correlacionada con la grasa y la energía (r = 0.23 y r = 0.24; P < 0.01). Sin embargo, Rs estuvo positivamente correlacionada con el agua, las cenizas y la PB (r = 0.31, P < 0.001; r = 0.28, P < 0.001; r = 0.37, P < 0.0001) y negativamente con la grasa y la energía (r = -0.36 y r = -0.35; P < 0.0001). Igualmente la edad estuvo negativamente correlacionada con el contenido en agua, cenizas y proteína (r = -0.79; r = -0.68 y r = -0.80; P < 0.0001) y positivamente con la grasa y la energía (r = 0.78 y r = 0.81; P < 0.0001). Se puede concluir que el método BIA es una técnica buena y no invasiva para estimar in vivo la composición corporal de conejos en crecimiento de 25 a 77 días de vida. El objetivo del segundo estudio fue determinar y validar con datos independientes las ecuaciones de predicción obtenidas para estimar in vivo la composición de la canal eviscerada mediante el uso de BIA en un grupo de conejos de 25 a 77 días, así como testar su aplicación para predecir la retención de nutrientes y calcular las eficacias de retención de la energía y del nitrógeno. Se utilizaron 75 conejos agrupados en 5 edades (25, 35, 49, 63 y 77 días de vida) con unos pesos que variaron entre 196 y 3260 g. Para determinar los valores de resistencia (Rs, ) y reactancia (Xc, ) se usó un terminal (Model BIA-101, RJL Systems, Detroit, MI USA) con cuatro electrodos. Igualmente se registró la distancia entre electrodos internos (D), la longitud corporal (L) y el peso vivo (PV) del cada animal. En cada edad, los animales fueron aturdidos y desangrados. Su piel, vísceras y contenido digestivo fueron retirados, y la canal oreada fue pesada y molida para posteriores análisis (MS, grasa, PB, cenizas y EB). Los contenidos en energía y grasa aumentaron mientras que los de agua, cenizas y proteína disminuyeron con la edad. Los valores medios de Rs, Xc, impedancia (Z), L y D fueron 95.9±23.9 , 19.5±4.7 , 98.0±23.8 , 20.6±6.3 cm y 13.7±3.1 cm. Se realizó un análisis de regresión linear múltiple para determinar las ecuaciones de predicción, utilizando los valores de PV, L and Z como variables independientes. Los coeficientes de determinación (R2) de las ecuaciones obtenidas para estimar los contenidos en agua (g), PB (g), grasa (g), cenizas (g) and EB (MJ) fueron: 0.99, 0.99, 0.95, 0.96 y 0.98, mientras que los errores medios de predicción relativos (EMPR) fueron: 4.20, 5.48, 21.9, 9.10 y 6.77%, respectivamente. Cuando el contenido en agua se expresó como porcentaje, los valores de R2 y EMPR fueron 0.79 y 1.62%, respectivamente. Cuando se realizó la predicción de los contenidos en proteína (%MS), grasa (%MS), cenizas (%MS) y energía (kJ/100 g MS), los valores de R2 fueron 0.68, 0.76, 0.66 and 0.82, y los de RMPE: 3.22, 10.5, 5.82 and 2.54%, respectivamente. La reactancia estuvo directamente correlacionada con el contenido en grasa (r = 0.24, P < 0.05), mientras que la resistencia guardó una correlación positiva con los contenidos en agua, cenizas y proteína (r = 0.55, P < 0.001; r = 0.54, P < 0.001; r = 0.40, P < 0.005) y negativa con la grasa y la energía (r = -0.44 y r = -0.55; P < 0.001). Igualmente la edad estuvo negativamente correlacionada con los contenidos en agua, cenizas y PB (r = -0.94; r = -0.85 y r = -0.75; P < 0.0001) y positivamente con la grasa y la energía (r = 0.89 y r = 0.90; P < 0.0001). Se estudió la eficacia global de retención de la energía (ERE) y del nitrógeno (ERN) durante todo el periodo de cebo (35-63 d), Los valores de ERE fueron 20.4±7.29%, 21.0±4.18% and 20.8±2.79% en los periodos 35 a 49, 49 a 63 y 35 a 63 d, respectivamente. ERN fue 46.9±11.7%, 34.5±7.32% y 39.1±3.23% para los mismos periodos. La energía fue retenida en los tejidos para crecimiento con una eficiencia del 52.5% y la eficiencia de retención de la energía como proteína y grasa fue de 33.3 y 69.9% respectivamente. La eficiencia de utilización del nitrógeno para crecimiento fue cercana al 77%. Este trabajo muestra como el método BIA es técnica buena y no invasiva para determinar in vivo la composición de la canal y la retención de nutrientes en conejos en crecimiento de 25 a 77 días de vida. En el tercer estudio, se llevaron a cabo dos experimentos con el fin de investigar los efectos del nivel de inclusión y de la fuente de grasa, sobre los rendimientos productivos, la mortalidad, la retención de nutrientes y la composición corporal total y de la canal eviscerada de conejos en crecimiento de 34 a 63 d de vida. En el Exp. 1 se formularon 3 dietas con un diseño experimental factorial 3 x 2 con el tipo de grasa utilizada: Aceite de Soja (SBO), Lecitinas de Soja (SLO) y Manteca (L) y el nivel de inclusión (1.5 y 4%) como factores principales. El Exp. 2 también fue diseñado con una estructura factorial 3 x 2, pero usando SBO, Aceite de Pescado (FO) y Aceite de Palmiste como fuentes de grasa, incluidas a los mismos niveles que en el Exp. 1. En ambos experimentos 180 animales fueron alojados en jaulas individuales (n=30) y 600 en jaulas colectivas en grupos de 5 animales (n=20). Los animales alimentados con un 4% de grasa añadida tuvieron unos consumos diarios y unos índices de conversión más bajos que aquellos alimentados con las dietas con un 1.5% de grasa. En los animales alojados en colectivo del Exp. 1, el consumo fue un 4.8% más alto en los que consumieron las dietas que contenían manteca que en los animales alimentados con las dietas SBO (P = 0.036). La inclusión de manteca tendió a reducir la mortalidad (P = 0.067) en torno al 60% y al 25% con respecto a las dietas con SBO y SLO, respectivamente. La mortalidad aumentó con el nivel máximo de inclusión de SLO (14% vs. 1%, P < 0.01), sin observarse un efecto negativo sobre la mortalidad con el nivel más alto de inclusión de las demás fuentes de grasa utilizadas. En los animales alojados colectivo del Exp. 2 se encontró una disminución del consumo (11%), peso vivo a 63 d (4.8%) y de la ganancia diaria de peso (7.8%) con la inclusión de aceite de pescado con respecto a otras dietas (P < 0.01). Los dos últimos parámetros se vieron especialmente más reducidos cuando en las dietas se incluyó el nivel más alto de FO (5.6 y 9.5%, respectivamente, (P < 0.01)). Los animales alojados individualmente mostraron unos resultados productivos muy similares. La inclusión de aceite pescado tendió (P = 0.078) a aumentar la mortalidad (13.2%) con respecto al aceite de palmiste (6.45%), siendo intermedia para las dietas que contenían SBO (8.10%). La fuente o el nivel de grasa no afectaron la composición corporal total o de la canal eviscerada de los animales. Un incremento en el nivel de grasa dio lugar a una disminución de la ingesta de nitrógeno digestible (DNi) (1.83 vs. 1.92 g/d; P = 0.068 en Exp. 1 y 1.79 vs. 1.95 g/d; P = 0.014 en Exp. 2). Debido a que el nitrógeno retenido (NR) en la canal fue similar para ambos niveles (0.68 g/d (Exp. 1) y 0.71 g/d (Exp. 2)), la eficacia total de retención del nitrógeno (ERN) aumentó con el nivel máximo de inclusión de grasa, pero de forma significativa únicamente en el Exp. 1 (34.9 vs. 37.8%; P < 0.0001), mientras que en el Exp. 2 se encontró una tendencia (36.2 vs. 38.0% en Exp. 2; P < 0.064). Como consecuencia, la excreción de nitrógeno en heces fue menor en los animales alimentados con el nivel más alto de grasa (0.782 vs. 0.868 g/d; P = 0.0001 en Exp. 1, y 0.745 vs. 0.865 g/d; P < 0.0001 en Exp.2) al igual que el nitrógeno excretado en orina (0.702 vs. 0.822 g/d; P < 0.0001 en Exp. 1 y 0.694 vs. 0.7999 g/d; P = 0.014 en Exp.2). Aunque no hubo diferencias en la eficacia total de retención de la energía (ERE), la energía excretada en heces disminuyó al aumentar el nivel de inclusión de grasa (142 vs. 156 Kcal/d; P = 0.0004 en Exp. 1 y 144 vs. 154 g/d; P = 0.050 en Exp. 2). Sin embargo, la energía excretada como orina y en forma de calor fue mayor en el los animales del Exp. 1 alimentados con el nivel más alto de grasa (216 vs. 204 Kcal/d; P < 0.017). Se puede concluir que la manteca y el aceite de palmiste pueden ser considerados como fuentes alternativas al aceite de soja debido a la reducción de la mortalidad, sin efectos negativos sobre los rendimientos productivos o la retención de nutrientes. La inclusión de aceite de pescado empeoró los rendimientos productivos y la mortalidad durante el periodo de crecimiento. Un aumento en el nivel de grasa mejoró el índice de conversión y la eficacia total de retención de nitrógeno. ABSTRACT The aim of this Thesis is: 1) to obtain and validate prediction equations to determine in vivo whole body and carcass composition using the Bioelectrical Impedance (BIA) method in growing rabbits from 25 to 77 days of age, and 2) to study its application to determine differences on whole body and carcass chemical composition, and nutrient retention of animals fed different fat levels and sources. The first study was conducted to determine and later validate, by using independent data, the prediction equations obtained to assess in vivo the whole body composition of growing rabbits. One hundred and fifty rabbits grouped at 5 different ages (25, 35, 49, 63 and 77 days) and weighing from 231 to 3138 g were used. A four terminal body composition analyser was used to obtain resistance (Rs, ) and reactance (Xc, ) values (Model BIA-101, RJL Systems, Detroit, MI USA). The distance between internal electrodes (D, cm), body length (L, cm) and live BW of each animal were also registered. At each selected age, animals were slaughtered, ground and frozen (-20 ºC) for later chemical analyses (DM, fat, CP, ash and GE). Fat and energy body content increased with the age, while protein, ash, and water decreased. Mean values of Rs, Xc, impedance (Z), L and D were 83.5 ± 23.1 , 18.2 ± 3.8 , 85.6 ± 22.9 , 30.6 ± 6.9 cm and 10.8 ± 3.1 cm. A multiple linear regression analysis was used to determine the prediction equations, using BW, L and Z data as independent variables. Equations obtained to estimate water (g), CP (g), fat (g), ash (g) and GE (MJ) content had, respectively, coefficient of determination (R2) values of 0.99, 0.99, 0.97, 0.98 and 0.99, and the relative mean prediction error (RMPE) was: 2.79, 6.15, 24.3, 15.2 and 10.6%, respectively. When water was expressed as percentage, the R2 and RMPE were 0.85 and 2.30%, respectively. When prediction of the content of protein (%DM), fat (%DM), ash (%DM) and energy (kJ/100 g DM) was done, values of 0.79, 0.83, 0.71 and 0.86 for R2, and 5.04, 18.9, 12.0 and 3.19% for RMPE, respectively, were obtained. Reactance was negatively correlated with water, ash and CP content (r = -0.32, P < 0.0001; r = -0.20, P < 0.05; r = -0.26, P < 0.01) and positively correlated with fat and GE (r = 0.23 and r = 0.24; P < 0.01). Otherwise, resistance was positively correlated with water, ash and CP (r = 0.31, P < 0.001; r = 0.28, P < 0.001; r = 0.37, P < 0.0001) and negatively correlated with fat and energy (r = -0.36 and r = -0.35; P < 0.0001). Moreover, age was negatively correlated with water, ash and CP content (r = -0.79; r = -0.68 and r = -0.80; P < 0.0001) and positively correlated with fat and energy (r = 0.78 and r = 0.81; P < 0.0001). It could be concluded that BIA is a non-invasive good method to estimate in vivo whole body composition of growing rabbits from 25 to 77 days of age. The aim of the second study was to determine and validate with independent data, the prediction equations obtained to estimate in vivo carcass composition of growing rabbits by using the results of carcass chemical composition and BIA values in a group of rabbits from 25 to 77 days. Also its potential application to predict nutrient retention and overall energy and nitrogen retention efficiencies was analysed. Seventy five rabbits grouped at 5 different ages (25, 35, 49, 63 and 77 days) with weights ranging from 196 to 3260 g were used. A four terminal body composition analyser (Model BIA-101, RJL Systems, Detroit, MI USA) was used to obtain resistance (Rs, ) and reactance (Xc, ) values. The distance between internal electrodes (D, cm), body length (L, cm) and live weight (BW, g) were also registered. At each selected age, all the animals were stunned and bled. The skin, organs and digestive content were removed, and the chilled carcass were weighed and processed for chemical analyses (DM, fat, CP, ash and GE). Energy and fat increased with the age, while CP, ash, and water decreased. Mean values of Rs, Xc, impedance (Z), L and D were 95.9±23.9 , 19.5±4.7 , 98.0±23.8 , 20.6±6.3 cm y 13.7±3.1 cm. A multiple linear regression analysis was done to determine the equations, using BW, L and Z data as parameters. Coefficient of determination (R2) of the equations obtained to estimate water (g), CP (g), fat (g), ash (g) and GE (MJ) content were: 0.99, 0.99, 0.95, 0.96 and 0.98, and relative mean prediction error (RMPE) were: 4.20, 5.48, 21.9, 9.10 and 6.77%, respectively. When water content was expressed as percentage, the R2 and RMPE were 0.79 and 1.62%, respectively. When prediction of protein (%DM), fat (%DM), ash (%DM) and energy (kJ/100 g DM) content was done, R2 values were 0.68, 0.76, 0.66 and 0.82, and RMPE: 3.22, 10.5, 5.82 and 2.54%, respectively. Reactance was positively correlated with fat content (r = 0.24, P < 0.05) while resistance was positively correlated with water, ash and protein carcass content (r = 0.55, P < 0.001; r = 0.54, P < 0.001; r = 0.40, P < 0.005) and negatively correlated with fat and energy (r = -0.44 and r = -0.55; P < 0.001). Moreover, age was negatively correlated with water, ash and CP content (r = -0.97, r = -0.95 and r = -0.89, P < 0.0001) and positively correlated with fat and GE (r = 0.95 and r = 0.97; P < 0.0001). In the whole growing period (35-63 d), overall energy retention efficiency (ERE) and nitrogen retention efficiency (NRE) were studied. The ERE values were 20.4±7.29%, 21.0±4.18% and 20.8±2.79%, from 35 to 49, 49 to 63 and from 35 to 63 d, respectively. NRE was 46.9±11.7%, 34.5±7.32% and 39.1±3.23% for the same periods. Energy was retained in body tissues for growth with an efficiency of approximately 52.5% and efficiency of the energy for protein and fat retention was 33.3 and 69.9%, respectively. Efficiency of utilization of nitrogen for growth was near to 77%. This work shows that BIA it’s a non-invasive and good method to estimate in vivo carcass composition and nutrient retention of growing rabbits from 25 to 77 days of age. In the third study, two experiments were conducted to investigate the effect of the fat addition and source, on performance, mortality, nutrient retention, and the whole body and carcass chemical composition of growing rabbits from 34 to 63 d. In Exp. 1 three diets were arranged in a 3 x 2 factorial structure with the source of fat: Soybean oil (SBO), Soya Lecithin Oil (SLO) and Lard (L) and the dietary fat inclusion level (1.5 and 4%) as the main factors. Exp. 2 had also arranged as a 3 x 2 factorial design, but using SBO, Fish Oil (FO) and Palmkernel Oil (PKO) as fat sources, and included at the same levels than in Exp. 1. In both experiments 180 animals were allocated in individual cages (n=30) and 600 in collectives cages, in groups of 5 animals (n=20). Animals fed with 4% dietary fat level showed lower DFI and FCR than those fed diets with 1.5%. In collective housing of Exp. 1, DFI was a 4.8% higher in animals fed with diets containing lard than SBO (P = 0.036), being intermediate for diet with SLO. Inclusion of lard also tended to reduce mortality (P = 0.067) around 60% and 25% with respect SBO and SLO diets, respectively. Mortality increased with the greatest level of soya lecithin (14% vs. 1%, P < 0.01). In Exp. 2 a decrease of DFI (11%), BW at 63 d (4.8%) and DWG (7.8%) were observed with the inclusion of fish oil with respect the other two diets (P < 0.01). These last two traits impaired with the highest level of fish oil (5.6 and 9.5%, respectively, (P < 0.01)). Animals housed individually showed similar performance results. The inclusion of fish oil also tended to increase (P = 0.078) mortality (13.2%) with respect palmkernel oil (6.45%), being mortality of SBO intermediate (8.10%). Fat source and level did not affect the whole body or carcass chemical composition. An increase of the fat sources addition led to a decrease of the digestible nitrogen intake (DNi) (1.83 vs. 1.92 g/d; P = 0.068 in Exp. 1 and 1.79 vs. 1.95 g/d; P = 0.014 in Exp. 2). As the nitrogen retained (NR) in the carcass was similar for both fat levels (0.68 g/d (Exp. 1) and 0.71 g/d (Exp. 2)), the overall efficiency of N retention (NRE) increased with the highest level of fat, but only reached significant level in Exp. 1 (34.9 vs. 37.8%; P < 0.0001), while in Exp. 2 a tendency was found (36.2 vs. 38.0% in Exp. 2; P < 0.064). Consequently, nitrogen excretion in faeces was lower in animals fed with the highest level of fat (0.782 vs. 0.868 g/d; P = 0.0001 in Exp. 1, and 0.745 vs. 0.865 g/d; P < 0.0001 in Exp.2). The same effect was observed with the nitrogen excreted as urine (0.702 vs. 0.822 g/d; P < 0.0001 in Exp. 1 and 0.694 vs. 0.7999 g/d; P = 0.014 in Exp.2). Although there were not differences in ERE, the energy excreted in faeces decreased as fat level increased (142 vs. 156 Kcal/d; P = 0.0004 in Exp. 1 and 144 vs. 154 g/d; P = 0.050 in Exp. 2). In Exp. 1 the energy excreted as urine and heat production was significantly higher when animals were fed with the highest level of dietary fat (216 vs. 204 Kcal/d; P < 0.017). It can be concluded that lard and palmkernel oil can be considered as alternative sources to soybean oil due to the reduction of the mortality, without negative effects on performances or nutrient retention. Inclusion of fish impaired animals´ productivity and mortality. An increase of the dietary fat level improved FCR and overall protein efficiency retention.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conductive nanoparticles, especially elongated ones such as carbon nanotubes, dramatically modify the electrical behavior of liquid crystal cells. These nanoparticles are known to reorient with liquid crystals in electric fields, causing significant variations of conductivity at minute concentrations of tens or hundreds ppm. The above notwithstanding, impedance spectroscopy of doped cells in the frequency range customarily employed by liquid crystal devices, 100 Hz?10 kHz, shows a relatively simple resistor/capacitor response where the components of the cell can be univocally assigned to single components of the electrical equivalent circuit. However, widening the frequency range up to 1 MHz or beyond reveals a complex behavior that cannot be explained with the same simple EEC. Moreover, the system impedance varies with the application of electric fields, their effect remaining after removing the field. Carbon nanotubes are reoriented together with liquid crystal reorientation when applying voltage, but barely reoriented back upon liquid crystal relaxation once the voltage is removed. Results demonstrate a remarkable variation in the impedance of the dielectric blend formed by liquid crystal and carbon nanotubes, the irreversible orientation of the carbon nanotubes and possible permanent contacts between electrodes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In recent times the Douglas–Rachford algorithm has been observed empirically to solve a variety of nonconvex feasibility problems including those of a combinatorial nature. For many of these problems current theory is not sufficient to explain this observed success and is mainly concerned with questions of local convergence. In this paper we analyze global behavior of the method for finding a point in the intersection of a half-space and a potentially non-convex set which is assumed to satisfy a well-quasi-ordering property or a property weaker than compactness. In particular, the special case in which the second set is finite is covered by our framework and provides a prototypical setting for combinatorial optimization problems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Article is devoted to design of optimum electromagnets for magnetic levitation of transport systems. The method of electromagnets design based on the inverse problem solution of electrical equipment is offered. The method differs from known by introducing a stage of minimization the target functions providing the stated levitation force and magnetic induction in a gap, and also the mass of an electromagnet. Initial values of parameters are received, using approximate formulas of the theory of electric devices and electrical equipment. The example of realization of a method is given. The received results show its high efficiency at design. It is practical to use the offered method and the computer program realizing it as a part of system of the automated design of electric equipment for transport with a magnetic levitation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

"C00-2118-0026."

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-04

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Well-densified 10 mol% Dy2O3-doped CeO2 (20DDC) ceramics with average grain sizes of similar to 0.12-1.5 mu m were fabricated by pressureless sintering at 950-1550 degrees C using a reactive powder thermally decomposed from a carbonate precursor, which was synthesized via a carbonate coprecipitation method employing nitrates as the starting salts and ammonium carbonate as the precipitant. Electrical conductivity of the ceramics, measured by the dc three-point impedance method, shows a V-shape curve against the average grain size. The sample with the smallest grain size of 0.12 mu m exhibits a high conductivity of similar to 10(-1.74) S/cm at the measurement temperature of 700 degrees C, which is about the same conduction level of the micro-grained 10 mol% Sm2O3- or Gd2O3-doped CeO2, two leading electrolyte materials. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The buffer allocation problem (BAP) is a well-known difficult problem in the design of production lines. We present a stochastic algorithm for solving the BAP, based on the cross-entropy method, a new paradigm for stochastic optimization. The algorithm involves the following iterative steps: (a) the generation of buffer allocations according to a certain random mechanism, followed by (b) the modification of this mechanism on the basis of cross-entropy minimization. Through various numerical experiments we demonstrate the efficiency of the proposed algorithm and show that the method can quickly generate (near-)optimal buffer allocations for fairly large production lines.