824 resultados para Discourse, conditionality, preventive measure, soft power, sanctionatory measure
Resumo:
The likelihood that comets may have delivered part of the water to Earth has been reinforced by the recent observation of the earth-like D/H ratio in Jupiter-family comet 103P/Hartley 2 by Hartogh et al. (2011). Prior to this observation, results from several Oort cloud comets indicated a factor of 2 enrichment of deuterium relative to the abundance at Earth. The European Space Agency’s Rosetta spacecraft will encounter comet 67P/Churyumov-Gerasimenko, another Jupiter-family comet of likely Kuiper belt origin, in 2014 and accompany it from almost aphelion to and past perihelion. Onboard Rosetta is the Rosetta Orbiter Spectrometer for Ion and Neutral Analysis (ROSINA) which consists of two mass spectrometers and a pressure sensor [Balsiger et al. 2007]. With its unprecedented mass resolution, for a space-borne instrument, the Double Focusing Mass Spectrometer (DFMS), one of the major subsystems of ROSINA, will be able to obtain unambiguously the ratios of the isotopes in water from in situ measurements in the coma around the comet. We will discuss the performance of this sensor on the basis of measurements of the terrestrial hydrogen and oxygen isotopic ratios performed with the flight spare instrument in the lab. We also show that the instrument on Rosetta is capable of measuring the D/H even in the very low density water background released by the spacecraft. This capability demonstrates that ROSINA should obtain very sensitive measurements of these ratios in the cometary environment. These measurements will allow detection of fractionation as function of the distance from the nucleus as well as fractionation due to mechanisms that are correlated with heliocentric distance.
Resumo:
BACKGROUND: We investigated the psychometric properties of a short questionnaire for combined assessment of different perceived stress management skills in the general population and tested whether scores relate to physiological stress reactivity. METHODS: For psychometric evaluation, we determined the factor structure of the questionnaire and investigated its measurement invariance in the participant groups and over time in three different independent samples representing the general population (total N=332). Reliability was tested by estimating test-retest reliability, internal consistency, and item reliabilities. We examined convergent and criterion validity using selected criterion variables. For endocrine validation, 35 healthy non-smoking and medication-free men in a laboratory study and 35 male and female employees in a workplace study underwent an acute standardized psychosocial stress task. We assessed stress management skills and measured salivary cortisol before and several times up to 60 min (workplace study) and 120 min (laboratory study) after stress. Potential confounders were controlled. RESULTS: The factor structure of the questionnaire consists of five scales reflecting acceptably distinct stress management skills such as cognitive strategies, use of social support, relaxation strategies, anger regulation, and perception of bodily tension. This factor structure was stable across participant groups and over time. Internal consistencies, item reliabilities, and test-retest reliabilities met established statistical requirements. Convergent and criterion validity were also established. In both endocrine validation studies, higher stress management skills were independently associated with lower cortisol stress reactivity (p's<.029). CONCLUSIONS: Our findings suggest that the questionnaire has good psychometric properties and that it relates to subjective psychological and objective physiological stress indicators. Therefore, the instrument seems a suitable measure for differential assessment of stress management skills in the general population.
Resumo:
Aggressive behavior can be classified in hostile and instrumental aggressions (anderson & bushman, 2002). this classification is mostly synonymously used with reactive and proactive aggression, whereas the differences between hostile and instrumental aggression lie on three dimensions, the primary goal, amount of anger and planning and calculation(bushman & anderson, 2001). although there are rating instruments and experimental paradigms to measure hostile aggression, there is no instrument to measure instrumental aggression. the following study will present an account to measure instrumental aggression with an experimental laboratory paradigm. the instrument was firstly tested on two samples of normal young adolescents (n1 = 100; amage. = 19.14; n2 = 60; amage. = 21.46). the first study revealed a strong correlation with a laboratory aggression paradigm measuring hostile aggression, but no correlations with self-reported aggression in the buss and perry questionnaire. these results were replicated in a second study, revealing an additional correlation with aggressive but not adaptive assertiveness. secondly the instrument was part of the evaluation of the reasoning and rehabilitation program r&r2 (ross, hilborn & lidell, 1984) in an institution for male adolescents with adjustment problems in switzerland. the r&r2 is a cognitive behavioral group therapy to reduce antisocial and promote prosocial cognitions and behavior. the treatment group (n= 16; rangeage = 15-17) is compared to a no treatment control group (n=24; rangeage = 17-19) preand post- treatment. further aggressive behavior was surveyed and experimentally measured. hostile rumination, aggressive and adaptive assertiveness, emotional and social competence were included in the measurement to estimate construct validity.
Resumo:
STATEMENT OF PROBLEM: Long-term fluoride application on the teeth of patients receiving radiation therapy for head and neck tumors results in excessive staining and roughening of ceramic restorations. PURPOSE: The purpose of this in vitro study was to compare the staining effects of 2 fluoride treatments on ceramic disks by simulating 1 year of clinical exposure at 10 minutes per day. In addition, 2 different surface preparations were tested. MATERIAL AND METHODS: Eighty ceramic disks (IPS Empress), 20 x 2 mm, were fabricated. Half of the disks were glazed, and the remaining disks were polished. All disks were brushed for 3 minutes with a soft-bristle power toothbrush and mild dentifrice (baseline) and were immersed in 1 of the 2 fluoride products (0.4% SnF(2), Gel-Kam Gel, or 1.1% NaF, Prevident 5000) for 10 days (n=20). Means and standard deviations of color change (Delta E), surface roughness (Ra, um), and surface gloss (GU) of the ceramic material were measured with a reflection spectrophotometer, a profilometer, and a gloss meter, respectively, at baseline and after fluoride treatment. Two- and 3-way ANOVA (alpha=.05), with surface preparation (polished vs. glazed) and fluoride treatment (0.4% SnF(2) or 1.1% NaF) as independent variables and condition (baseline vs. after fluoride treatment) as a repeated measure, was used to analyze the data. Fisher's PLSD intervals (alpha=.05) were calculated for comparisons among the means. RESULTS: The polished specimens had significantly higher Delta E values, significantly higher surface gloss values, and significantly lower surface roughness values than the glazed specimens before fluoride treatment (P<.001). After both fluoride treatments, ceramic disks exhibited significantly higher surface roughness values when polished and significantly lower surface gloss values when glazed or polished (P<.001). The glazed specimens presented significantly higher surface roughness (P<.001) and lower surface gloss values (P<.001) when treated with 0.4% SnF(2) as compared to NaF. For the polished specimens, there was no significant difference in surface roughness and surface gloss values between the 2 fluoride treatments. CONCLUSIONS: Use of 0.4% SnF(2) and 1.1% NaF gels, in vitro, caused significant color change in the polished IPS Empress ceramic disks. Polishing of the ceramic surface before immersion in either fluoride agent caused the ceramic tested to be more resistant to etching by the 2 solutions tested. The NaF caused less deterioration of the porcelain surface and was less stain inducing than SnF(2).
Resumo:
Effective visual exploration is required for many activities of daily living and instruments to assess visual exploration are important for the evaluation of the visual and the oculomotor system. In this article, the development of a new instrument to measure central and peripheral target recognition is described. The measurement setup consists of a hemispherical projection which allows presenting images over a large area of ±90° horizontal and vertical angle. In a feasibility study with 14 younger (21–49 years) and 12 older (50–78 years) test persons, 132 targets and 24 distractors were presented within naturalistic color photographs of everyday scenes at 10°, 30°, and 50° eccentricity. After the experiment, both younger and older participants reported in a questionnaire that the task is easy to understand, fun and that it measures a competence that is relevant for activities of daily living. A main result of the pilot study was that younger participants recognized more targets with smaller reaction times than older participants. The group differences were most pronounced for peripheral target detection. This test is feasible and appropriate to assess the functional field of view in younger and older adults.
Resumo:
Excavated by French Egyptologist P. Montet in the 1920s, Royal Tomb II at Byblos (Bronze Age Gubla) yielded a significant number of Egyptian objects of the Middle Kingdom. Among these finds is a stone vessel with lid that carries the cartouche of a king named Amenemhat, often believed to be Amenemhat IV of the late Middle Kingdom. Hitherto unnoticed by the scholarly community, however, are two Egyptian measure capacity signs on the stone vessel itself. Since measure capacity signs on stone vessels dating to the Middle Kingdom are only rarely attested even in Egypt, the signs on the stone vessel from Royal Tomb II at Byblos therefore contribute considerably to our understanding of the use and application of such signs. The article deals with the examination of these signs and tries to correlate them with the actual capacity of the vessel.
Resumo:
We propose to build and operate a detector based on the emulsion film technology for the measurement of the gravitational acceleration on antimatter, to be performed by the AEgIS experiment (AD6) at CERN. The goal of AEgIS is to test the weak equivalence principle with a precision of 1% on the gravitational acceleration g by measuring the vertical position of the annihilation vertex of antihydrogen atoms after their free fall while moving horizontally in a vacuum pipe. With the emulsion technology developed at the University of Bern we propose to improve the performance of AEgIS by exploiting the superior position resolution of emulsion films over other particle detectors. The idea is to use a new type of emulsion films, especially developed for applications in vacuum, to yield a spatial resolution of the order of one micron in the measurement of the sag of the antihydrogen atoms in the gravitational field. This is an order of magnitude better than what was planned in the original AEgIS proposal.
Resumo:
OBJECTIVE The aim of the study was to describe the (a) symptom experience of women with vulvar intraepithelial neoplasia and vulvar cancer (vulvar neoplasia) during the first week after hospital discharge, and (b) associations between age, type of disease, stage of disease, the extent of surgical treatment and symptom experience. METHODS This cross-sectional study was conducted in eight hospitals in Germany and Switzerland (Clinical Trial ID: NCT01300663). Symptom experience after surgical treatment in women with vulvar neoplasia was measured with our newly developed WOMAN-PRO instrument. Outpatients (n=65) rated 31 items. We used descriptive statistics and regression analysis. RESULTS The average number of symptoms reported per patient was 20.2 (SD 5.77) with a range of 5 to 31 symptoms. The three most prevalent wound-related symptoms were 'swelling' (n=56), 'drainage' (n=54) and 'pain' (n=52). The three most prevalent difficulties in daily life were 'sitting' (n=63), 'wearing clothes' (n=56) and 'carrying out my daily activities' (n=51). 'Tiredness' (n=62), 'insecurity' (n=54) and 'feeling that my body has changed' (n=50) were the three most prevalent psychosocial symptoms/issues. The most distressing symptoms were 'sitting' (Mean 2.03, SD 0.88), 'open spot (e.g. opening of skin or suture)' (Mean 1.91, SD 0.93), and 'carrying out my daily activities' (Mean 1.86, SD 0.87), which were on average reported as 'quite a bit' distressing. Negative associations were found between psychosocial symptom experience and age. CONCLUSIONS WOMAN-PRO data showed a high symptom prevalence and distress, call for a comprehensive symptom assessment, and may allow identification of relevant areas in symptom management.
Resumo:
Aims: This study investigated whether children aged between 8 - 12 years born very preterm (VPT) and/or at very low birth weight (VLBW) performed lower than same-aged term-born controls in cognitive and behavioral aspects of three executive functions: inhibition, working memory, and shifting. Special attention was given to sex differences. Methods: Fifty-two VPT/VLBW children (26 girls) born in the cohort of 1998–2003 at the Children’s University Hospital in Bern, Switzerland, and 36 same-aged term-born controls (18 girls) were recruited. As cognitive measures, children completed tasks of inhibition (Colour-Word Interference Test, D-KEFS), working memory (digit span backwards, WISC-IV) and shifting (Trail Making Test, number-letter switching, D-KEFS). As behavioral measures, mothers completed the Behavior Rating Inventory of Executive Function (BRIEF), assessing executive functions in everyday life.
Resumo:
BACKGROUND The number of older adults in the global population is increasing. This demographic shift leads to an increasing prevalence of age-associated disorders, such as Alzheimer's disease and other types of dementia. With the progression of the disease, the risk for institutional care increases, which contrasts with the desire of most patients to stay in their home environment. Despite doctors' and caregivers' awareness of the patient's cognitive status, they are often uncertain about its consequences on activities of daily living (ADL). To provide effective care, they need to know how patients cope with ADL, in particular, the estimation of risks associated with the cognitive decline. The occurrence, performance, and duration of different ADL are important indicators of functional ability. The patient's ability to cope with these activities is traditionally assessed with questionnaires, which has disadvantages (eg, lack of reliability and sensitivity). Several groups have proposed sensor-based systems to recognize and quantify these activities in the patient's home. Combined with Web technology, these systems can inform caregivers about their patients in real-time (e.g., via smartphone). OBJECTIVE We hypothesize that a non-intrusive system, which does not use body-mounted sensors, video-based imaging, and microphone recordings would be better suited for use in dementia patients. Since it does not require patient's attention and compliance, such a system might be well accepted by patients. We present a passive, Web-based, non-intrusive, assistive technology system that recognizes and classifies ADL. METHODS The components of this novel assistive technology system were wireless sensors distributed in every room of the participant's home and a central computer unit (CCU). The environmental data were acquired for 20 days (per participant) and then stored and processed on the CCU. In consultation with medical experts, eight ADL were classified. RESULTS In this study, 10 healthy participants (6 women, 4 men; mean age 48.8 years; SD 20.0 years; age range 28-79 years) were included. For explorative purposes, one female Alzheimer patient (Montreal Cognitive Assessment score=23, Timed Up and Go=19.8 seconds, Trail Making Test A=84.3 seconds, Trail Making Test B=146 seconds) was measured in parallel with the healthy subjects. In total, 1317 ADL were performed by the participants, 1211 ADL were classified correctly, and 106 ADL were missed. This led to an overall sensitivity of 91.27% and a specificity of 92.52%. Each subject performed an average of 134.8 ADL (SD 75). CONCLUSIONS The non-intrusive wireless sensor system can acquire environmental data essential for the classification of activities of daily living. By analyzing retrieved data, it is possible to distinguish and assign data patterns to subjects' specific activities and to identify eight different activities in daily living. The Web-based technology allows the system to improve care and provides valuable information about the patient in real-time.
Resumo:
Let {μ(i)t}t≥0 ( i=1,2 ) be continuous convolution semigroups (c.c.s.) of probability measures on Aff(1) (the affine group on the real line). Suppose that μ(1)1=μ(2)1 . Assume furthermore that {μ(1)t}t≥0 is a Gaussian c.c.s. (in the sense that its generating distribution is a sum of a primitive distribution and a second-order differential operator). Then μ(1)t=μ(2)t for all t≥0 . We end up with a possible application in mathematical finance.
Resumo:
BACKGROUND: Higher visual functions can be defined as cognitive processes responsible for object recognition, color and shape perception, and motion detection. People with impaired higher visual functions after unilateral brain lesion are often tested with paper pencil tests, but such tests do not assess the degree of interaction between the healthy brain hemisphere and the impaired one. Hence, visual functions are not tested separately in the contralesional and ipsilesional visual hemifields. METHODS: A new measurement setup, that involves real-time comparisons of shape and size of objects, orientation of lines, speed and direction of moving patterns, in the right or left visual hemifield, has been developed. The setup was implemented in an immersive environment like a hemisphere to take into account the effects of peripheral and central vision, and eventual visual field losses. Due to the non-flat screen of the hemisphere, a distortion algorithm was needed to adapt the projected images to the surface. Several approaches were studied and, based on a comparison between projected images and original ones, the best one was used for the implementation of the test. Fifty-seven healthy volunteers were then tested in a pilot study. A Satisfaction Questionnaire was used to assess the usability of the new measurement setup. RESULTS: The results of the distortion algorithm showed a structural similarity between the warped images and the original ones higher than 97%. The results of the pilot study showed an accuracy in comparing images in the two visual hemifields of 0.18 visual degrees and 0.19 visual degrees for size and shape discrimination, respectively, 2.56° for line orientation, 0.33 visual degrees/s for speed perception and 7.41° for recognition of motion direction. The outcome of the Satisfaction Questionnaire showed a high acceptance of the battery by the participants. CONCLUSIONS: A new method to measure higher visual functions in an immersive environment was presented. The study focused on the usability of the developed battery rather than the performance at the visual tasks. A battery of five subtasks to study the perception of size, shape, orientation, speed and motion direction was developed. The test setup is now ready to be tested in neurological patients.