998 resultados para Digital-subtraction-angiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Andalusian eHealth Library (BV-SSPA) was set up in 2006, but the region already had 42 librarians who worked at hospitals or other centers and were in charge of their libraries. The Digital library meant for all of them the availability of a greater amount of scientific resources and also the challenge of adapting to this new environment which brought new tasks and responsibilities to their daily work, and required the development of new skills. The time has arrived to analyze how they have implemented this change and how it has transformed their professional profile within the Andalusian Health System. Nowadays, the Andalusian eHealth Library establishes the librarian’s targets and their work is evaluated according to the fulfillment of these targets. This evaluation is carried out by the director of the BV-SSPA, taking into account the performance related to the general stated targets, as well as their level of commitment to the Digital Library through the performing of specific assigned tasks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To develop and evaluate a practical method for the quantification of signal-to-noise ratio (SNR) on coronary MR angiograms (MRA) acquired with parallel imaging.Materials and Methods: To quantify the spatially varying noise due to parallel imaging reconstruction, a new method has been implemented incorporating image data acquisition followed by a fast noise scan during which radio-frequency pulses, cardiac triggering and navigator gating are disabled. The performance of this method was evaluated in a phantom study where SNR measurements were compared with those of a reference standard (multiple repetitions). Subsequently, SNR of myocardium and posterior skeletal muscle was determined on in vivo human coronary MRA.Results: In a phantom, the SNR measured using the proposed method deviated less than 10.1% from the reference method for small geometry factors (<= 2). In vivo, the noise scan for a 10 min coronary MRA acquisition was acquired in 30 s. Higher signal and lower SNR, due to spatially varying noise, were found in myocardium compared with posterior skeletal muscle.Conclusion: SNR quantification based on a fast noise scan is a validated and easy-to-use method when applied to three-dimensional coronary MRA obtained with parallel imaging as long as the geometry factor remains low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Els gèneres periodístics tradicionals s’estan adaptant acceleradament al periodisme digital. De fet, arran dels fenòmens de mitosi mediàtica i mediamorfosi, l’adaptació és mútua: un nou entorn, amb més rapidesa, una nova tipologia de lector i unes noves maneres de produir estan provocant unes sinergies que solquen tot el mitjà i, sobretot, els continguts, els gèneres. És per això que el Grup de Recerca i Anàlisi sobre Periodisme Digital, creat pel Centre d’Estudis sobre el Cable (CECABLE) el 2008, està portant a terme un estudi científic de comparació empírica entre diaris digitals i tradicionals del qual es desprenen unes perspectives d’adaptació i desenvolupament encoratjadores per als gèneres clàssics i oportunitats per als gèneres sorgits de l’onada digital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Objectif : Le but de ce travail est d`étudier l'angiographie par scanner multi-barrette (AS) dans l'évaluation de l'artériopathie oblitérante (AOMI) de l'aorte abdominale et des membres inférieurs utilisant une méthode adaptative d'acquisition pour optimiser le rehaussement artériel en particulier pour le lit artériel distal et les artères des pieds. Matériels et méthodes : Trente-quatre patients pressentant une AOMI ont bénéficié d'une angiographie trans-cathéter (ATC) et d'une AS dans un délai inférieur ou égal à 15 jours. L'AS a été effectuée du tronc coeliaque jusqu'aux artères des pieds en une seule acquisition utilisant une haute résolution spatiale (16x0.625 mm). La vitesse de table et le temps de rotation pour chaque examen ont été choisis selon le temps de transit du produit de contraste, obtenu après un bolus test. Une quantité totale de 130 ml de contraste à 4 ml/s a été utilisée. L'analyse des images de l'AS a été effectuée par deux observateurs et les données ATC ont été interprétées de manière indépendante par deux autres observateurs. L'analyse a inclus la qualité de l'image et la détection de sténose supérieure ou égale à 50 % par patient et par segment artériel. La sensibilité et la spécificité de l'AS ont été calculées en considérant l'ATC comme examen de référence. La variabilité Interobservateur a été mesurée au moyen d'une statistique de kappa. Résultas : L'ATC a été non-conclusive dans 0.7 % des segments, tandis que l'AS était conclusive dans tous les segments. Sur l'analyse par patient, la sensibilité et la spécificité totales pour détecter une sténose significative égale ou supérieure à 50 % étaient de 100 %. L'analyse par segment a montré des sensibilités et de spécificités variant respectivement de 91 à 100 % et de 81 à 100 %. L'analyse des artères distales des pieds a révélé une sensibilité de 100 % et une spécificité de 90 %. Conclusion : L'angiographie par CT multi-barrettes utilisant cette méthode adaptative d'acquisition améliore la qualité de l'image et fournit une technique non-invasive et fiable pour évaluer L'AOMI, y compris les artères distales des pieds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: An accurate, noninvasive technique for the diagnosis of coronary disease would be an important advance. We investigated the accuracy of coronary magnetic resonance angiography among patients with suspected coronary disease in a prospective, multicenter study. METHODS: Coronary magnetic resonance angiography was performed during free breathing in 109 patients before elective x-ray coronary angiography, and the results of the two diagnostic procedures were compared. RESULTS: A total of 636 of 759 proximal and middle segments of coronary arteries (84 percent) were interpretable on magnetic resonance angiography. In these segments, 78 (83 percent) of 94 clinically significant lesions (those with a > or = 50 percent reduction in diameter on x-ray angiography) were also detected by magnetic resonance angiography. Overall, coronary magnetic resonance angiography had an accuracy of 72 percent (95 percent confidence interval, 63 to 81 percent) in diagnosing coronary artery disease. The sensitivity, specificity, and accuracy for patients with disease of the left main coronary artery or three-vessel disease were 100 percent (95 percent confidence interval, 97 to 100 percent), 85 percent (95 percent confidence interval, 78 to 92 percent), and 87 percent (95 percent confidence interval, 81 to 93 percent), respectively. The negative predictive values for any coronary artery disease and for left main artery or three-vessel disease were 81 percent (95 percent confidence interval, 73 to 89 percent) and 100 percent (95 percent confidence interval, 97 to 100 percent), respectively. CONCLUSIONS: Among patients referred for their first x-ray coronary angiogram, three-dimensional coronary magnetic resonance angiography allows for the accurate detection of coronary artery disease of the proximal and middle segments. This noninvasive approach reliably identifies (or rules out) left main coronary artery or three-vessel disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hermes Comunicacions és el primer grup de comunicació escrita en català, quecompta amb 54.000 exemplars cada dia al carrer i prop de 600.000 lectors ainternet. És la responsable de les publicacions: El Punt Avui (edicions Nacionali Comarques Gironines), Presència, L’Econòmic, Sortim, Catalonia Today i El 9Esportiu.Actualment, es disposa de tres vies per difondre les diferents publicacions: paper, web i El quiosc (web d’accés a subscriptors). Aquest projecte pretén desenvolupar l’aplicació i entorn necessaris per lacreació d’una quarta via de difusió dels diferents productes, facilitant-ne lavisualització mitjançant dispositius mòbils. Concretament ens centrarem en elsdispositius mòbils d’Apple basats en el sistema operatiu iOS.Degut a que ens trobem davant d’un nou entorn per als desenvolupadors i peral client, preveiem que aniran sorgint canvis durant el transcurs del projecte.Per tant decidim utilitzar una metodologia flexible als canvis de requeriments.Les metodologies àgils són les que millor s’ajusten al desenvolupament que esvol fer. Dins el conjunt de metodologies àgils, hem escollit Scrum. Tot i que és unametodologia pensada per a treball en equip, l’adaptem al nostre cas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Postmortem investigations are becoming more and more sophisticated. CT and MRI are already being used in pathology and forensic medicine. In this context, the impact of postmortem angiography increases because of the rapid evaluation of organ-specific vascular patterns, vascular alteration under pathologic and physiologic conditions, and tissue changes induced by artificial and unnatural causes. CONCLUSION: In this article, the advantages and disadvantages of former and current techniques and contrast agents are reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El Servei de Biblioteques de la UAB gestiona un dipòsit digital que cobreix les expectatives generades per un dipòsit institucional a la vegada que actua facilitant la consulta de la biblioteca digital pròpia. La naturalesa diversa de les col·leccions, quant a origen i format ens ha obligat a utilitzar eines de gestió específiques per establir els circuits, mètodes i procediments de treball. Volem compartir la nostra experiència, tant a nivell de creació d'un únic dipòsit capaç de gestionar tot el nostre fons digital, com de les opcions de treball intern escollides.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Realitzar una proposta per a millorar la competència digital a la ESO mitjançant un estudi d'altres sistemes educatius i realitzar una proposta de treball per projectes interdisciplinaris.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary magnetic resonance angiography (MRA) is a powerful noninvasive technique with high soft-tissue contrast for the visualization of the coronary anatomy without X-ray exposure. Due to the small dimensions and tortuous nature of the coronary arteries, a high spatial resolution and sufficient volumetric coverage have to be obtained. However, this necessitates scanning times that are typically much longer than one cardiac cycle. By collecting image data during multiple RR intervals, one can successfully acquire coronary MR angiograms. However, constant cardiac contraction and relaxation, as well as respiratory motion, adversely affect image quality. Therefore, sophisticated motion-compensation strategies are needed. Furthermore, a high contrast between the coronary arteries and the surrounding tissue is mandatory. In the present article, challenges and solutions of coronary imaging are discussed, and results obtained in both healthy and diseased states are reviewed. This includes preliminary data obtained with state-of-the-art techniques such as steady-state free precession (SSFP), whole-heart imaging, intravascular contrast agents, coronary vessel wall imaging, and high-field imaging. Simultaneously, the utility of electron beam computed tomography (EBCT) and multidetector computed tomography (MDCT) for the visualization of the coronary arteries is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To objectively compare quantitative parameters related to image quality attained at coronary magnetic resonance (MR) angiography of the right coronary artery (RCA) performed at 7 T and 3 T. MATERIALS AND METHODS: Institutional review board approval was obtained, and volunteers provided signed informed consent. Ten healthy adult volunteers (mean age ± standard deviation, 25 years ± 4; seven men, three women) underwent navigator-gated three-dimensional MR angiography of the RCA at 7 T and 3 T. For 7 T, a custom-built quadrature radiofrequency transmit-receive surface coil was used. At 3 T, a commercial body radiofrequency transmit coil and a cardiac coil array for signal reception were used. Segmented k-space gradient-echo imaging with spectrally selective adiabatic fat suppression was performed, and imaging parameters were similar at both field strengths. Contrast-to-noise ratio between blood and epicardial fat; signal-to-noise ratio of the blood pool; RCA vessel sharpness, diameter, and length; and navigator efficiency were quantified at both field strengths and compared by using a Mann-Whitney U test. RESULTS: The contrast-to-noise ratio between blood and epicardial fat was significantly improved at 7 T when compared with that at 3 T (87 ± 34 versus 52 ± 13; P = .01). Signal-to-noise ratio of the blood pool was increased at 7 T (109 ± 47 versus 67 ± 19; P = .02). Vessel sharpness obtained at 7 T was also higher (58% ± 9 versus 50% ± 5; P = .04). At the same time, RCA vessel diameter and length and navigator efficiency showed no significant field strength-dependent difference. CONCLUSION: In our quantitative and qualitative study comparing in vivo human imaging of the RCA at 7 T and 3 T in young healthy volunteers, parameters related to image quality attained at 7 T equal or surpass those from 3 T.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest document és un esborrany. Amb l'objectiu d'aprofundir en el procés d'institucionalització, vam dissenyar una investigació empírica que permetés visualitzar les tendències discursives i àmbits d'activitats de les pràctiques relacionades amb les interseccions entre l'art, la ciència i la tecnologia. La metodologia va consistir en la implementació de tres bases de dades que recullen l'activitat dels últims anys en relació a: 1) els congressos (i festivals associats) realitzats a nivell internacional 2) les publicacions acadèmiques i divulgatives centrades en aquest àmbit interdisciplinar 3) els programes acadèmics.