892 resultados para Detection system
Resumo:
A spectrophotometric flow injection method for the determination of Zn(II) in ophthalmic formulations was developed. In this work, Zn(II) ion was complexed with Alizarin red S in borate buffer solution (pH 9.0) and the chromophore produced was monitored at 520 nm. The analytical curve was linear in the Zn(II) concentration range from 6.05 x 10-6 to 1.50 x 10-4 mol L-1 with a detection limit of 3.60 x 10-6 mol L-1. Recoveries ranged from 96.3 to 105 % and a relative standard deviation of 1.2 % (n = 10) for 5.5x10-5 mol L-1 Zn(II) reference solution were obtained. The sampling rate was 60 h-1 and the results obtained of Zn(II) in ophthalmic products using this procedure are in close agreement with those obtained using a comparative spectrophotometric procedure at 95 % confidence level.
Resumo:
An optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2 determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or carbonate samples are injected in a buffer carrier solution, and then are mixed with phosphoric acid solution to generate CO2, which diffuses through a PTFE membrane, in order to be collected in an acceptor carrier fluid, pumped towards to detection cell, in which the optode was adapted. The proposed system presents two linear response ranges, from 1.0 x 10-3 to 1.0 x 10-2 mol l-1, and from 2.0 x 10-2 to 0.10 mol l-1. The sampling frequency was 11 sample h-1, with good repeatability (R.S.D < 4 %, n = 10). In flow conditions the optode lifetime was 170 h. The system was applied in the analysis of commercial mineral water and the results obtained in the hydrogen carbonate determination did not differ significantly from those obtained by potentiometry, at a confidence level of 95 %.
Resumo:
The soybean is important to the economy of Brazil, so the estimation of the planted area and the production with higher antecedence and reliability becomes essential. Techniques related to Remote Sensing may help to obtain this information at lower cost and less subjectivity in relation to traditional surveys. The aim of this study is to estimate the planted area with soybean culture in the crop of 2008/2009 in cities in the west of the state of Paraná, in Brazil, based on the spectral dynamics of the culture and through the use of the specific system of analysis for images of Landsat 5/TM satellite. The obtained results were satisfactory, because the classification supervised by Maximum Verisimilitude - MaxVer along with the techniques of the specific system of analysis for satellite images has allowed an estimate of soybean planted area (soybean mask), obtaining values of the metrics of Global Accuracy with an average of 79.05% and Kappa Index over 63.50% in all cities. The monitoring of a reference area was of great importance for determining the vegetative phase in which the culture is more different from the other targets, facilitating the choice of training samples (ROIs) and avoiding misclassifications.
Resumo:
The aim of this study was to use digital images acquired by cameras attached to a helium balloon to detect variation of the nutritional status in Brachiaria decumbens. The treatments consisted of five doses of nitrogen (0, 50, 100, 150 e 200kg ha-1) with six replications each, evaluated in a completely randomized statistical design. A remote sensing system composed of digital cameras and microcomputers was used for image acquisition, and a helium balloon lifted the cameras to the heights of 15, 20, 25 and 30m. A portable chlorophyll meter and analyses of leaf nitrogen content were used to make comparisons with data obtained by the remote sensing system. Data was acquired in two phases, in different climatic conditions. At the end of each phase, dry matter production was measured. Three vegetation indices were used to evaluate the detection of different nutritional status. The three indices were able to detect the effects of N doses. The indices constructed with the Green spectral band showed to be more efficient.
Resumo:
Fraud is an increasing phenomenon as shown in many surveys carried out by leading international consulting companies in the last years. Despite the evolution of electronic payments and hacking techniques there is still a strong human component in fraud schemes. Conflict of interest in particular is the main contributing factor to the success of internal fraud. In such cases anomaly detection tools are not always the best instruments, since the fraud schemes are based on faking documents in a context dominated by lack of controls, and the perpetrators are those ones who should control possible irregularities. In the banking sector audit team experts can count only on their experience, whistle blowing and the reports sent by their inspectors. The Fraud Interactive Decision Expert System (FIDES), which is the core of this research, is a multi-agent system built to support auditors in evaluating suspicious behaviours and to speed up the evaluation process in order to detect or prevent fraud schemes. The system combines Think-map, Delphi method and Attack trees and it has been built around audit team experts and their needs. The output of FIDES is an attack tree, a tree-based diagram to ”systematically categorize the different ways in which a system can be attacked”. Once the attack tree is built, auditors can choose the path they perceive as more suitable and decide whether or not to start the investigation. The system is meant for use in the future to retrieve old cases in order to match them with new ones and find similarities. The retrieving features of the system will be useful to simplify the risk management phase, since similar countermeasures adopted for past cases might be useful for present ones. Even though FIDES has been built with the banking sector in mind, it can be applied in all those organisations, like insurance companies or public organizations, where anti-fraud activity is based on a central anti-fraud unit and a reporting system.
Resumo:
Mycoplasma gallisepticum (MG) and Mycoplasma synoviae (MS) are the mycoplasma infections of most concern for commercial poultry industry. MG infection is commonly designated as chronic respiratory disease (CRD) of chickens and infections sinusitis of turkeys. MS causes sub clinical upper respiratory infection and tenosynovitis or bursitis in chickens and turkeys. The multiplex PCR was standardized to detect simultaneously the MS, MG field strains and MG F-vaccine strain specific. The generic PCR for detection of any species of Mollicutes Class was performed and compared to the multiplex PCR and to PCR using species-specific primers. A total of 129 avian tracheal swabs were collected from broiler-breeders, layer hens and broilers in seven different farms and were examined by multiplex PCR methods. The system (multiplex PCR) demonstrated to be very rapid, sensitive, and specific. Therefore, the results showed a high prevalence of MS in the flocks examined (27.9%), and indicate that the MS is a recurrent pathogen in Brazilian commercial poultry flocks.
Resumo:
Crack formation and growth in steel bridge structural elements may be due to loading oscillations. The welded elements are liable to internal discontinuities along welded joints and sensible to stress variations. The evaluation of the remaining life of a bridge is needed to make cost-effective decisions regarding inspection, repair, rehabilitation, and replacement. A steel beam model has been proposed to simulate crack openings due to cyclic loads. Two possible alternatives have been considered to model crack propagation, which the initial phase is based on the linear fracture mechanics. Then, the model is extended to take into account the elastoplastic fracture mechanic concepts. The natural frequency changes are directly related to moment of inertia variation and consequently to a reduction in the flexural stiffness of a steel beam. Thus, it is possible to adopt a nondestructive technique during steel bridge inspection to quantify the structure eigenvalue variation that will be used to localize the grown fracture. A damage detection algorithm is developed for the proposed model and the numerical results are compared with the solutions achieved by using another well know computer code.
Resumo:
Fan systems are responsible for approximately 10% of the electricity consumption in industrial and municipal sectors, and it has been found that there is energy-saving potential in these systems. To this end, variable speed drives (VSDs) are used to enhance the efficiency of fan systems. Usually, fan system operation is optimized based on measurements of the system, but there are seldom readily installed meters in the system that can be used for the purpose. Thus, sensorless methods are needed for the optimization of fan system operation. In this thesis, methods for the fan operating point estimation with a variable speed drive are studied and discussed. These methods can be used for the energy efficient control of the fan system without additional measurements. The operation of these methods is validated by laboratory measurements and data from an industrial fan system. In addition to their energy consumption, condition monitoring of fan systems is a key issue as fans are an integral part of various production processes. Fan system condition monitoring is usually carried out with vibration measurements, which again increase the system complexity. However, variable speed drives can already be used for pumping system condition monitoring. Therefore, it would add to the usability of a variablespeed- driven fan system if the variable speed drive could be used as a condition monitoring device. In this thesis, sensorless detection methods for three lifetime-reducing phenomena are suggested: these are detection of the fan contamination build-up, the correct rotational direction, and the fan surge. The methods use the variable speed drive monitoring and control options for the detection along with simple signal processing methods, such as power spectrum density estimates. The methods have been validated by laboratory measurements. The key finding of this doctoral thesis is that a variable speed drive can be used on its own as a monitoring and control device for the fan system energy efficiency, and it can also be used in the detection of certain lifetime-reducing phenomena.
Resumo:
This study examines the practice of supply chain management problems and the perceived demand information distortion’s (the bullwhip effect) reduction with the interfirm information system, which is delivered as a cloud service to a company operating in the telecommunications industry. The purpose is to shed light in practice that do the interfirm information system have impact on the performance of the supply chain and in particularly the reduction of bullwhip effect. In addition, a holistic case study of the global telecommunications company's supply chain is presented and also the challenges it’s facing, and this study also proposes some measures to improve the situation. The theoretical part consists of the supply chain and its management, as well as increasing the efficiency and introducing the theories and related previous research. In addition, study presents performance metrics for the bullwhip effect detection and tracking. The theoretical part ends in presenting cloud -based business intelligence theoretical framework used in the background of this study. The research strategy is a qualitative case study, supported by quantitative data, which is collected from a telecommunication sector company's databases. Qualitative data were gathered mainly with two open interviews and the e-mail exchange during the development project. In addition, other materials from the company were collected during the project and the company's web site information was also used as the source. The data was collected to a specific case study database in order to increase reliability. The results show that the bullwhip effect can be reduced with the interfirm information system and with the use of CPFR and S&OP models and in particularly combining them to an integrated business planning. According to this study the interfirm information system does not, however, solve all of the supply chain and their effectiveness -related problems, because also the company’s processes and human activities have a major impact.
Resumo:
We have developed a procedure for nonradioactive single strand conformation polymorphism analysis and applied it to the detection of point mutations in the human tumor suppressor gene p53. The protocol does not require any particular facilities or equipment, such as radioactive handling, large gel units for sequencing, or a semiautomated electrophoresis system. This technique consists of amplification of DNA fragments by PCR with specific oligonucleotide primers, denaturation, and electrophoresis on small neutral polyacrylamide gels, followed by silver staining. The sensitivity of this procedure is comparable to other described techniques and the method is easy to perform and applicable to a variety of tissue specimens.
Resumo:
Apoptosis is a well-known specific process of cell death that normally occurs in physiological situations such as tissue or organ development and involution. During tumor growth there is a balance between proliferation and cell death which involves apoptotic mechanisms. In the present study genomic DNAs from 120 breast tumor biopsies were analyzed by agarose gel electrophoresis and none of them presented the fragmentation pattern characteristic of the apoptosis process. However, 33% of the 105 breast cancer patients clearly showed the apoptotic pattern when DNA from blood cells was analyzed. None of the DNAs from healthy volunteer blood cells showed any trace of apoptosis. Since the breast cancer patients were not receiving chemo- or hormone therapy, the possible relationship between blood cortisol levels and the apoptotic pattern found in patient blood cells was investigated. Using a chemoluminescence immunodetection assay, similar cortisol levels were observed in breast cancer patient sera presenting or not apoptotic blood cells and in healthy volunteer sera. Analysis of the clinical data obtained from 60 of these patients showed that patients bearing tumors of smaller size (under 20 mm) were more susceptible to the apoptotic effect in blood cells. According to the Elston grade, it was observed that 7 of 12 patients with grade III tumors (58%) presented apoptotic peripheral blood cells, in contrast to 10 of 48 patients with grade I and grade II tumors. These observations may reflect the immunosuppression characteristic of some breast cancer patients, which may contribute to tumor growth. Therefore, further studies are necessary to elucidate the factor(s) involved in such massive blood cell death.
Resumo:
The use of the flow vs time relationship obtained with the nasal prongs of the AutoSetä (AS) system (diagnosis mode) has been proposed to detect apneas and hypopneas in patients with reasonable nasal patency. Our aim was to compare the accuracy of AS to that of a computerized polysomnographic (PSG) system. The study was conducted on 56 individuals (45 men) with clinical characteristics of obstructive sleep apnea (OSA). Their mean (± SD) age was 44.6 ± 12 years and their body mass index was 31.3 ± 7 kg/m2. Data were submitted to parametric analysis to determine the agreement between methods and the intraclass correlation coefficient was calculated. The Student t-test and Bland and Altman plots were also used. Twelve patients had an apnea-hypopnea index (AHI) <10 in bed and 20 had values >40. The mean (± SD) AHI PSG index of 37.6 (28.8) was significantly lower (P = 0.0003) than AHI AS (41.8 (25.3)), but there was a high intraclass correlation coefficient (0.93), with 0.016 variance. For a threshold of AHI of 20, AS showed 73.0% accuracy, 97% sensitivity and 60% specificity, with positive and negative predictive values of 78% and 93%, respectively. Sensitivity, specificity and negative predictive values increased in parallel to the increase in AHI threshold for detecting OSA. However, when the differences of AHI PSG-AS were plotted against their means, the limits of agreement between the methods (95% of the differences) were +13 and -22, showing the discrepancy between the AHI values obtained with PSG and AS. Finally, cubic regression analysis was used to better predict the result of AHI PSG as a function of the method proposed, i.e., AHI AS. We conclude that, despite these differences, AHI measured by AutoSetä can be useful for the assessment of patients with high pre-test clinical probability of OSA, for whom standard PSG is not possible as an initial step in diagnosis.
Resumo:
We have developed a system with two epi-illumination sources, a DC-regulated lamp for transillumination and mechanical switches for rapid shift of illumination and detection of defined areas (250-750 µm²) by fluorescence and phosphorescence videomicroscopy. The system permits investigation of standard microvascular parameters, vascular permeability as well as intra- and extravascular PO2 by phosphorescence quenching of Pd-meso-tetra (4-carboxyphenyl) porphine (PORPH). A Pechan prism was used to position a defined region over the photomultiplier and TV camera. In order to validate the system for in vivo use, in vitro tests were performed with probes at concentrations that can be found in microvascular studies. Extensive in vitro evaluations were performed by filling glass capillaries with solutions of various concentrations of FITC-dextran (diluted in blood and in saline) mixed with different amounts of PORPH. Fluorescence intensity and phosphorescence decay were determined for each mixture. FITC-dextran solutions without PORPH and PORPH solutions without FITC-dextran were used as references. Phosphorescence decay curves were relatively unaffected by the presence of FITC-dextran at all concentrations tested (0.1 µg/ml to 5 mg/ml). Likewise, fluorescence determinations were performed in the presence of PORPH (0.05 to 0.5 mg/ml). The system was successfully used to study macromolecular extravasation and PO2 in the rat mesentery circulation under controlled conditions and during ischemia-reperfusion.
Resumo:
The vascularization of the central nervous system of the snail Megalobulimus oblongus was studied by injection of carmine-gelatin solution into the arterial system and using a histochemical technique for the detection of alkaline phosphatase. The central nervous system of M. oblongus is irrigated by the anterior aorta, from which a series of small branches emerge that supply the subesophageal nervous ganglia. In turn, these branches give rise to a series of smaller vessels that irrigate the buccal bulb, the anterior portion of the foot, the cerebral ganglia, the dorsal body gland, and the anterior portion of the reproductive system. No hemolymph vessels were detected within nervous tissue although such vessels were found in the periganglionic connective sheath. This connective sheath contains vascular loops and had a series of overlaps and projections that follow the contour of the nervous ganglia. This arrangement permits a larger area of interaction between the surface of the nervous tissue and the hemolymph and reduces the distance between the deepest portion of a given ganglion and the hemolymph vessels.
Resumo:
Clinical decision support systems are useful tools for assisting physicians to diagnose complex illnesses. Schizophrenia is a complex, heterogeneous and incapacitating mental disorder that should be detected as early as possible to avoid a most serious outcome. These artificial intelligence systems might be useful in the early detection of schizophrenia disorder. The objective of the present study was to describe the development of such a clinical decision support system for the diagnosis of schizophrenia spectrum disorders (SADDESQ). The development of this system is described in four stages: knowledge acquisition, knowledge organization, the development of a computer-assisted model, and the evaluation of the system's performance. The knowledge was extracted from an expert through open interviews. These interviews aimed to explore the expert's diagnostic decision-making process for the diagnosis of schizophrenia. A graph methodology was employed to identify the elements involved in the reasoning process. Knowledge was first organized and modeled by means of algorithms and then transferred to a computational model created by the covering approach. The performance assessment involved the comparison of the diagnoses of 38 clinical vignettes between an expert and the SADDESQ. The results showed a relatively low rate of misclassification (18-34%) and a good performance by SADDESQ in the diagnosis of schizophrenia, with an accuracy of 66-82%. The accuracy was higher when schizophreniform disorder was considered as the presence of schizophrenia disorder. Although these results are preliminary, the SADDESQ has exhibited a satisfactory performance, which needs to be further evaluated within a clinical setting.