877 resultados para Design and analyses


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cleverly designed molecular building blocks provide chemists with the tools of a powerful molecular-scale construction set. They enable them to engineer materials having a predictable order and useful solid-state properties. Hence, it is in the realm of supramolecular chemistry to follow a strategy for synthesizing materials which combine a selected set of properties, for instance from the areas of magnetism, photophysics and electronics. As a successful approach, host/guest solids which are based on extended anionic, homo- and bimetallic oxalato-bridged transition-metal compounds with two-and three-dimensional connectivities have been investigated. In this report, a brief review is given on the structural aspects of this class of compounds followed by a presentation of a thermal and magnetic study for two distinct, heterometallic oxalato-bridged layer compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sample preparation procedures for AMS measurements of 129I and 127I in environmental materials and some methodological aspects of quality assurance are discussed. Measurements from analyses of some pre-nuclear soil and thyroid gland samples and of a systematic investigation of natural waters in Lower Saxony, Germany, are described. Although the up-to-now lowest 129I/127I ratios in soils and thyroid glands were observed, they are still suspect to contamination since they are significantly higher than the pre-nuclear equilibrium ratio in the marine hydrosphere. A survey on all available 129I/127I isotopic ratios in precipitation shows a dramatic increase until the middle of the 1980s and a stabilization since 1987 at high isotopic ratios of about (3.6–8.3)×10−7. In surface waters, ratios of (57–380)×10−10 are measured while shallow ground waters show with ratios of (1.3–200)×10−10 significantly lower values with a much larger spread. The data for 129I in soils and in precipitation are used to estimate pre-nuclear and modern 129I deposition densities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Sutureless aortic valve replacement (SU-AVR) is an innovative approach which shortens cardiopulmonary bypass and cross-clamp durations and may facilitate minimally invasive approach. Evidence outlining its safety, efficacy, hemodynamic profile and potential complications is replete with small-volume observational studies and few comparative publications. METHODS Minimally invasive aortic valve surgery and high-volume SU-AVR replacement centers were contacted for recruitment into a global collaborative coalition dedicated to sutureless valve research. A Research Steering Committee was formulated to direct research and support the mission of providing registry evidence warranted for SU-AVR. RESULTS The International Valvular Surgery Study Group (IVSSG) was formed under the auspices of the Research Steering Committee, comprised of 36 expert valvular surgeons from 27 major centers across the globe. IVSSG Sutureless Projects currently proceeding include the Retrospective and Prospective Phases of the SU-AVR International Registry (SU-AVR-IR). CONCLUSIONS The global pooling of data by the IVSSG Sutureless Projects will provide required robust clinical evidence on the safety, efficacy and hemodynamic outcomes of SU-AVR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intraoperative laparoscopic calibration remains a challenging task. In this work we present a new method and instrumentation for intraoperative camera calibration. Contrary to conventional calibration methods, the proposed technique allows intraoperative laparoscope calibration from single perspective observations, resulting in a standardized scheme for calibrating in a clinical scenario. Results show an average displacement error of 0.52 ± 0.19 mm, indicating sufficient accuracy for clinical use. Additionally, the proposed method is validated clinically by performing a calibration during the surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The usage of intensity modulated radiotherapy (IMRT) treatments necessitates a significant amount of patient-specific quality assurance (QA). This research has investigated the precision and accuracy of Kodak EDR2 film measurements for IMRT verifications, the use of comparisons between 2D dose calculations and measurements to improve treatment plan beam models, and the dosimetric impact of delivery errors. New measurement techniques and software were developed and used clinically at M. D. Anderson Cancer Center. The software implemented two new dose comparison parameters, the 2D normalized agreement test (NAT) and the scalar NAT index. A single-film calibration technique using multileaf collimator (MLC) delivery was developed. EDR2 film's optical density response was found to be sensitive to several factors: radiation time, length of time between exposure and processing, and phantom material. Precision of EDR2 film measurements was found to be better than 1%. For IMRT verification, EDR2 film measurements agreed with ion chamber results to 2%/2mm accuracy for single-beam fluence map verifications and to 5%/2mm for transverse plane measurements of complete plan dose distributions. The same system was used to quantitatively optimize the radiation field offset and MLC transmission beam modeling parameters for Varian MLCs. While scalar dose comparison metrics can work well for optimization purposes, the influence of external parameters on the dose discrepancies must be minimized. The ability of 2D verifications to detect delivery errors was tested with simulated data. The dosimetric characteristics of delivery errors were compared to patient-specific clinical IMRT verifications. For the clinical verifications, the NAT index and percent of pixels failing the gamma index were exponentially distributed and dependent upon the measurement phantom but not the treatment site. Delivery errors affecting all beams in the treatment plan were flagged by the NAT index, although delivery errors impacting only one beam could not be differentiated from routine clinical verification discrepancies. Clinical use of this system will flag outliers, allow physicists to examine their causes, and perhaps improve the level of agreement between radiation dose distribution measurements and calculations. The principles used to design and evaluate this system are extensible to future multidimensional dose measurements and comparisons. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a large health care system, the importance of accurate information as feedback mechanisms about its performance is necessary on many levels from the senior level management to service level managers for valid decision-making purposes. The implementation of dashboards is one way to remedy the problem of data overload by providing up-to-date, accurate, and concise information. As this health care system seeks to have an organized, systematic review mechanism in place, dashboards are being created in a variety of the hospital service departments to monitor performance indicators. The Infection Control Administration of this health care system is one that does not currently utilize a dashboard but seeks to implement one. ^ The purpose of this project is to research and design a clinical dashboard for the Infection Control Administration. The intent is that the implementation and usefulness of the clinical dashboard translates into improvement in the measurement of health care quality.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of respiratory motion on patient anatomy poses a challenge to accurate radiation therapy, especially in lung cancer treatment. Modern radiation therapy planning uses models of tumor respiratory motion to account for target motion in targeting. The tumor motion model can be verified on a per-treatment session basis with four-dimensional cone-beam computed tomography (4D-CBCT), which acquires an image set of the dynamic target throughout the respiratory cycle during the therapy session. 4D-CBCT is undersampled if the scan time is too short. However, short scan time is desirable in clinical practice to reduce patient setup time. This dissertation presents the design and optimization of 4D-CBCT to reduce the impact of undersampling artifacts with short scan times. This work measures the impact of undersampling artifacts on the accuracy of target motion measurement under different sampling conditions and for various object sizes and motions. The results provide a minimum scan time such that the target tracking error is less than a specified tolerance. This work also presents new image reconstruction algorithms for reducing undersampling artifacts in undersampled datasets by taking advantage of the assumption that the relevant motion of interest is contained within a volume-of-interest (VOI). It is shown that the VOI-based reconstruction provides more accurate image intensity than standard reconstruction. The VOI-based reconstruction produced 43% fewer least-squares error inside the VOI and 84% fewer error throughout the image in a study designed to simulate target motion. The VOI-based reconstruction approach can reduce acquisition time and improve image quality in 4D-CBCT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mineral compositions of residual peridotites collected at various locations in the Mid-Atlantic Ridge south of the Kane transform (MARK area) are consistent with generally smaller degrees of melting in the mantle near the large offset Kane transform than near the other, small offset, axial discontinuities in the area. We propose that this transform fault effect is due to along-axis variations in the final depth of melting in the subaxial mantle, reflecting the colder thermal regime of the ridge near the Kane transform. Calculations made with a passive mantle flow regime suggest that these along-axis variations in the final depth of melting would not produce the full range of crustal thickness variations observed in the MARK area seismic record. It is therefore likely that the transform fault effect in the MARK area is combined with other mechanisms capable of producing crustal thickness variations, such as along-axis melt migration, the trapping of part of the magma in a cold mantle root beneath the ridge, or active mantle upwelling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The first radiocarbon chronology for sediments of the Argentine basin has been determined using accelerator mass spectrometer (AMS) analyses of 54 total organic carbon samples from four box and two piston cores collected from the downstream and upstream sides of two central Argentine Basin mudwaves. Throughout the Holocene, sediment from the geomorphically defined upstream side of each wave accumulated at rates of 30 to 105 cm/1000 years. Sediments from the downstream side of each wave accumulated at rates of 2 to 10 cm/1000 years in the late and early Holocene, while the mid Holocene is characterized by sedimentation rates less than 1.0 cm/1000 years. During the mid-Holocene, increased aridity reduced chemical weathering and the flow of the rivers draining to the continental shelf, causing a concomitant decrease in fine-grained terrigenous input to the basin as evidenced by decreased sedimentation rates, lower N/C ratios, and depleted delta13Corg values. It is estimated that all of the organic carbon deposited in the central basin during the mid-Holocene was of a marine origin. During the late and early Holocene, however, approximately 35% of the organic carbon deposited was of terrestrial origin. Bottom water flow speeds in the late Holocene were estimated using a lee-wave model and found to average 14 cm/s. This estimate is comparable to 10 cm/s mean and 15-20 cm/s maximum flow speeds measured by current meters deployed within the basin. Flow speeds in the Argentine Basin were 10% higher than today from 8000 to 2000 B.P., and are consistent with a general invigoration of thermohaline circulation that began between 9000 and 8000 B.P. It is proposed that the introduction of warm, salty Indian Ocean water into the northern North Atlantic at 9000 B.P. was the mechanism that provided the excess salt needed to stabilize the North Atlantic Deep Water thermohaline circulation system in its present mode.