999 resultados para Cr-51-release


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest projecte forma part d’un estudi sobre l’eliminació de metalls pesants utilitzant com aadsorbents residus d’indústries agroalimentàries, que des de fa uns quants anys està duent aterme el grup de Metalls i Medi Ambient (MiMA) del Departament d’Enginyeria Química,Agrària i Tecnologia Agroalimentària de la Universitat de Girona. L’objecte del treball és parametritzar un procés basat en marro de cafè que inclouetapes de reducció/adsorció i precipitació per al tractament d’aigües residuals quecontenen Cr(VI) i altres metalls. La parametrització permetrà conèixer en quinmoment s’ha assolit la reducció total del Cr(VI) en la primera etapa del tractament perpoder passar a una segona etapa d’eliminació de la resta dels metalls presents en solució

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selectivity studies for the determination of Cr(VI) using the catalytic oxidation of the o-dianisidine by hydrogen peroxide showed two distincts situations. In the first, when interferents were studied by a univariate procedure, Cr(III) and Cu(II) cause serious interferences even at the 2:1 proportion, relative to Cr(VI), while Fe(III) interfered at the 15:1 ratio and EDTA at the 10:1 ratio. On the other hand, when a multivariate investigation was performed, Cr(III) did not present any significant principal effects and its significant interaction effects were negative, in contrast to EDTA, that presented positive interaction effects although, like Cr(III), did not show significant interaction effects. In view of the interferent's action it become necessary to separate Cr(VI) by extraction with methylisobutylketone in a chloridric acid medium before its determination in vegetals and in wastewater from a cellulose industry samples. Using this procedure, the method precision is ±0,5% at the 10 ng/mL Cr(VI) concentration level. The detection and quantification limits, calculated by means of absorbance measurements of ten replicates of blank reagents were 1,1 and 3,2 ng/mL, respectively. The results obtained with real samples showed a relative standard deviation between 1,2% and 3,0% relative to their reference values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The equilibria, the spectra and the identities of the species of Cr(VI) that are present in aqueous solution have long been an active subject of discussion in the literature. In this paper, three different chemometric methodologies are applied to sets of UV/Visible spectra of aqueous Cr(VI) solutions, in order to solve a chemical system where there is no available information concerning the composition of the samples nor spectral information about the pure species. Imbrie Q-mode factor analysis, followed by varimax rotation and Imbrie oblique projection, were used to estimate the composition of Cr(VI) equilibrium solutions and, by combining these results with the k-matrix method, to obtain the pure spectra of the species. Evolving factor analysis and self modeling curve resolution were used to confirm the number of the species and the resolution of the system, respectively. Sets of 3.3×10-4 and 3.3×10-5 mol L-1 Cr(VI) solutions, respectively, were analyzed in the pH range from 1 to 12. Two factors were identified, which were related to the chromate ion (CrO4(2-)) and bichromate ion (HCrO4-). The pK of the equilibrium was estimated as 5.8.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present experiment describes an easy procedure for obtaining SiO2/ZrO2 by reacting ZrOCl2 with SiO2 with the following characteristics: S BET = 500 m² g-1 and an average pore diameter of 6 nm. The material obtained presented 1.3 wt% ZrO2 content corresponding to 140 mumol g-1. The average density of ZrO2 onto SiO2/ZrO2 matrix is 2.8x10-11 mol cm-2. The adsorption isotherm for Cr(VI) showed a maximum of adsorption value (200 mumol g-1) at pH 2. The adsorption can be described by the reaction: =Zr(OH)2 + 2HCrO4- + 2H+ [(=Zr(OH2+)2) (HCrO4-)2]. Above the zero point of charge, i.e. pH > 5.5 due to the surface charge inversion, desorption of Cr(VI) occurs according to the reaction: [(=Zr(OH2+)2) (HCrO4-)2] + 6OH- (=ZrO2)2- + 6H2O + 2CrO4(2-).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soitinnus: Piano.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the preparation of the xerogel anilinepropylsilica is reported. The ability of the xerogel for extracting Al(III), Cr(III) and Fe(III) from ethanol was investigated at 25 ºC. The xerogel adsorption capacities were obtained from the adsorption isotherms by using the batch method. Flame atomic absorption spectrometry (FAAS) was used to estimate the concentration of metal ions in solution. The adsorption affinity follows the series Cr(III) > Fe(III) > Al(III) and the maximum adsorption capacities of the metal ions were 0.61, 0.52 and 0.43 mmol g-1, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two samples of residues from iron mining plants have been investigated for their retention capacity of As, Cu, Cr, and Pb. The sample with the higher content of iron oxides showed the highest capacity to retain metals. The adsorption affinity series changes from Pb>Cu>Cr~As to As>Pb>Cu>Cr or As>Cu>Cr>Pb, depending on the material and the concentration of the initial solution. In the competitive environment, the Pb adsorption decreases and the As, Cu and Cr adsorption increases. Sequential extraction procedures, carried out after adsorption batch experiments, showed that the most important adsorption process occurs in the oxide fraction and that the major part of the absorbed metal is remobilized from exchangeable and oxide fractions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digitoitu 13. 8. 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digitoitu 13. 8. 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, one important objective of cardiovascular research has been to find new markers that would improve the risk stratification and diagnosis of patients presenting with symptoms of acute coronary syndrome (ACS). Pregnancy-associated plasma protein A (PAPP-A) is a large metalloproteinase involved in insulin-like growth factor signalling. It is expressed in various tissues and seems to be involved in many physiological and pathological processes, such as folliculogenesis, bone formation, wound healing, pregnancy and atherosclerosis. The aim of this thesis was to investigate PAPP-A in ACS patients. Circulating concentrations of PAPP-A had been previously shown to be elevated in ACS. In this study it was revealed that the form of PAPP-A causing this elevation was the free noncomplexed PAPP-A. Thus, the form of PAPP-A in the circulation of ACS patients differed from the complexed PAPP-A form abundantly present in the circulation during pregnancy. A point-of-care method based on time-resolved immunofluorometric assays was developed, which enabled the rapid detection of free PAPP-A. The method was found to perform well with serum and heparin plasma samples as well as with heparinized whole blood samples. With this method the concentrations of free PAPP-A in healthy individuals were shown to be negligible. When the clinical performance of the method was evaluated with serum samples from ACS patients, it was shown that the free PAPP-A concentration in the admission sample was an independent predictor of myocardial infarction and death. Moreover, as a prognostic marker, free PAPP-A was revealed to be superior to total PAPPA, i.e. the combination of free and complexed PAPP-A, which has been measured by the other groups in this field. As heparin products are widely used as medication in ACS patients, the effect of heparin products on free PAPP-A molecule and circulating concentrations were also investigated in this study. It was shown that intravenous administration of low molecular weight or unfractionated heparin elicits a rapid release of free PAPP-A into the circulation in haemodialysis patients and patients undergoing angiography. Moreover, the interaction between PAPP-A and heparin was confirmed in gel filtration studies. Importantly, the patients included in the clinical evaluation of the free PAPP-A detection method developed had not received any heparin product medication before the admission sample and thus the results were not affected by the heparin effect. In conclusion, free PAPP-A was identified as a novel marker associated with ACS. The point-of-care methods developed enable rapid detection of this molecule which predicts adverse outcome when measured in the admission sample of ACS patients. However, the effect revealed of heparin products on circulating PAPP-A concentrations should be acknowledged when further studies are conducted related to free or total PAPP-A in ACS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the use of wild animal hair of C. brachyurus, C. thous and L. pardalis as biomonitors of trace metal at Parque Nacional das Emas, Brazil. Results reveal a strong correlation between Cd and Pb as well as Cu and Zn, which suggests a single source of emission. Most metals showed a lower or equal concentration than those obtained in previous studies. The research shows that monitoring may be performed only with Zn, Pb, Cd, and Cr because of statistical similarity and of a non-natural occurrence of large amounts of the material under analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess a new monitoring technique of particulate and trace metals in the atmosphere via the use of a passive sampler of air pollutants in the city of Goiânia. The average particulate weight and average concentrations of metals Fe, Cr, Zn, Pb, Cu, Mn, and Cd were 0.1104 g and 257.5; 23.4; 17.8; 6.7; 1.9; 0.8; 0.2 μg/m²/day, respectively. Higher Pb and Cr concentrations were obtained in areas with intense traffic. This study revealed that it is possible to monitor trace metals with passive sampling, developed at a low cost and operational facility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The synthesis and characterization of crosslinked chitosan microbeads and their application in the removal of Cr(VI) are described. New kinetic and thermodynamic parameters of Cr(VI) adsorptions processes were found using continuous isothermal calorimetry. All adsorption processes are exothermic in nature. However, a multivariate statistical analysis have pointed out that adsorption enthalpies were affected by important binary interactions of the initial Cr(VI) in solution and temperature. The adsorption energetic data were well fitted to a kinetic exponential model, which have indicated fractionary adsorption kinetic orders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were to formulate calcium-alginate beads containing glibenclamide, characterize the resulting microparticles, evaluate the release characteristics of this type of delivery system in an in vitro dissolution test, and compare it with two commercially available trademarks (Daonil® and Glibetab®). We obtained glibenclamide loaded calcium-alginate beads with a rough surface and a particle size between 150-200 µm. For the in vitro dissolution test Daonil® at 45 min showed a Q > 70%, whereas Glibetab® and glibenclamide calcium-alginate beads a Q < 70%; in spite of that glibenclamide calcium-alginate beads showed significant release properties.