888 resultados para Assurance de dommages
Resumo:
Pantothenicacid (PA), vitamin B5, is an essential B vitamin that may be fortified in food and as such requires robust and accurate methods of detection to meet compliance legislation. This study reports the production and characterisation of the first monoclonalantibody (MAb) specific for PA and the subsequent development of a surface plasmon resonance (SPR) biosensorassay for the quantification of PA. The developed assay was compared with an SPR based commercial kit which utilised a polyclonal antibody (PAb). Foodstuffs, including cereals (n = 43), infant formulas and baby food (n = 10) and fruit juices (n = 48) were analysed by both the MAb and PAb biosensorassays and comparison plots showed good correlation (R2 0.77–0.99). The results indicate that the MAb basedbiosensorassay is suitable for the measurement of PA in foodstuffs and has the added advantage of facilitating a constant, long term supply of identical antibody. Preliminary matrix studies suggest the MAb basedassay is an excellent candidate for further validation studies and routine quality assurance based analysis.
Resumo:
The purpose of this paper is to provide a framework for developing an effective evaluation practice within health care settings. Three features are reviewed; capacity building, the application of evaluation to program activities and the utilization of evaluation recommendations. First, the organizational elements required to establish effective evaluation practice are reviewed emphasizing that an organization's capacity for evaluation develops over time and in stages. Second, a comprehensive evaluation framework is presented which demonstrates how evaluation practice can be applied to all aspects of a program's life cycle, thus promoting the scope of evidence-based decision making within an organization. Finally, factors which influence the adoption of evaluation recommendations by decision makers are reviewed accompanied by strategies to promote the utilization of evaluation recommendations in organization decision making.
Resumo:
Although general practitioners (GPs) and community pharmacists (CPs) are encouraged to collaborate, a true collaborative relationship does not exist between them. Our objective was to identify and analyze factors affecting GP-CP collaboration.
Resumo:
Elevated intraocular pressure (IOP) is a major risk factor for the deterioration of open-angle glaucoma (OAG); medical IOP reduction is the standard treatment, yet no randomized placebo-controlled study of medical IOP reduction has been undertaken previously. The United Kingdom Glaucoma Treatment Study (UKGTS) tests the hypothesis that treatment with a topical prostaglandin analog, compared with placebo, reduces the frequency of visual field (VF) deterioration events in OAG patients by 50% over a 2-year period.
Resumo:
This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.
Resumo:
The commonly used British Standard constant head triaxial permeability test for testing of fine-grained soils is relatively time consuming. A reduction in the required time for soil permeability testing would provide potential cost savings to the construction industry, particularly in the construction quality assurance of landfill clay liners. The purpose of this paper is to evaluate an alternative approach of measuring permeability of fine-grained soils benefiting from accelerated time scaling for seepage flow when testing specimens in elevated gravity conditions provided by a centrifuge. As part of the investigation, an apparatus was designed and produced to measure water flow through soil samples under conditions of elevated gravitational acceleration using a small desktop laboratory centrifuge. A membrane was used to hydrostatically confine the test sample. A miniature data acquisition system was designed and incorporated in the apparatus to monitor and record changes in head and flow throughout the tests. Under enhanced gravity in the centrifuge, the flow through the sample was under ‘variable head' conditions as opposed to ‘constant head' conditions as in the classic constant head permeability tests conducted at 1 g . A mathematical model was developed for analysis of Darcy's coefficient of permeability under conditions of elevated gravitational acceleration and verified using the results obtained. The test data compare well with the results on analogous samples obtained using the classical British Standard constant head permeability tests.
Resumo:
The transition from medical student to junior doctor is well recognised to be a difficult and stressful period. To ease this transition, most UK universities have a work-shadowing period (WSP), during which students can learn practical skills needed for forthcoming employment. The aim of this study was to evaluate the WSP at Queen's University Belfast, and gain the views of both students and Foundation Programme Supervisors and Directors (FPSDs). The study utilised both qualitative (focus groups) and quantitative (questionnaires) approaches. The FPSDs completed a specific questionnaire designed for this study, while the students completed the university's internal quality assurance questionnaire. Twenty-eight of the 37 (76%) FPSDs and 106 / 196 (54%) students completed the questionnaires. Focus groups were conducted with up to 10 students in each group in both a regional centre and a district general hospital at the start and the end of the WSP as well as 8 weeks into working life. The transcripts of the focus groups were analysed and themes identified. A number of deficiencies with the current WSP were identified, including concerns about the use of log books, the timing of the attachment and relatively low levels of supervision provided by senior hospital staff members. As a result, students felt unprepared for commencing work, with particular mention given to medical emergencies, prescribing, and the emotional aspects of the job. A number of recommendations are made, including the need for more senior input to ensure better student attendance, participation and clinical interaction. Furthermore, students should be offered additional supervised responsibility for delivery of patient care and more experiential learning with respect to drug prescribing and administration. The study also suggests that more needs to be done to help ease the emotional and psychological stresses of the early FY1 period. These issues have been resolved to a large extent with the introduction of the new final year Student Assistantship module in the academic year 2010-2011. © The Ulster Medical Society, 2012.
Resumo:
Purpose: In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans.
Methods: The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams. Dosimetric and mechanical accuracy of the detector array within the Octavius 4D rotational phantom was evaluated against measurements made using semiflex and pinpoint ionization chambers, and radiochromic film. Verification FF and FFF RapidArc plans were assessed using a gamma function with 3%/3 mm tolerances and 2%/2 mm tolerances and further analysis of these plans was undertaken using film and a second detector array with higher spatial resolution.
Results: A warm-up dose of >6 Gy was required for detector stability. Dose-rate measurements were stable across a range from 0.26 to 15 Gy/min and dose response was linear, although the device overestimated small doses compared with pinpoint ionization chamber measurements. Output factors agreed with ionization chamber measurements to within 0.6% for square fields of side between 3 and 25 cm and within 1.2% for 2 x 2 cm(2) fields. The Octavius 4D phantom was found to be consistent with measurements made with radiochromic film, where the gantry angle was found to be within 0.4. of that expected during rotational deliveries. RapidArc FF and FFF beams were found to have an accuracy of >97.9% and >90% of pixels passing 3%/3 mm and 2%/2 mm, respectively. Detector spatial resolution was observed to be a factor in determining the accurate delivery of each plan, particularly at steep dose gradients. This was confirmed using data from a second detector array with higher spatial resolution and with radiochromic film.
Conclusions: The Octavius 4D phantom with associated Octavius detector 729 ionization chamber array is a dosimetrically and mechanically stable device for pretreatment verification of FF and FFF RapidArc treatments. Further improvements may be possible through use of a detector array with higher spatial resolution (detector size and/or detector spacing). (C) 2013 American Association of Physicists in Medicine.
Resumo:
This study aims to evaluate the use of Varian radiotherapy dynamic treatment log (DynaLog) files to verify IMRT plan delivery as part of a routine quality assurance procedure. Delivery accuracy in terms of machine performance was quantified by multileaf collimator (MLC) position errors and fluence delivery accuracy for patients receiving intensity modulated radiation therapy (IMRT) treatment. The relationship between machine performance and plan complexity, quantified by the modulation complexity score (MCS) was also investigated. Actual MLC positions and delivered fraction of monitor units (MU), recorded every 50 ms during IMRT delivery, were extracted from the DynaLog files. The planned MLC positions and fractional MU were taken from the record and verify system MLC control file. Planned and delivered beam data were compared to determine leaf position errors with and without the overshoot effect. Analysis was also performed on planned and actual fluence maps reconstructed from the MLC control file and delivered treatment log files respectively. This analysis was performed for all treatment fractions for 5 prostate, 5 prostate and pelvic node (PPN) and 5 head and neck (H&N) IMRT plans, totalling 82 IMRT fields in ∼5500 DynaLog files. The root mean square (RMS) leaf position errors without the overshoot effect were 0.09, 0.26, 0.19 mm for the prostate, PPN and H&N plans respectively, which increased to 0.30, 0.39 and 0.30 mm when the overshoot effect was considered. Average errors were not affected by the overshoot effect and were 0.05, 0.13 and 0.17 mm for prostate, PPN and H&N plans respectively. The percentage of pixels passing fluence map gamma analysis at 3%/3 mm was 99.94 ± 0.25%, which reduced to 91.62 ± 11.39% at 1%/1 mm criterion. Leaf position errors, but not gamma passing rate, were directly related to plan complexity as determined by the MCS. Site specific confidence intervals for average leaf position errors were set at -0.03-0.12 mm for prostate and -0.02-0.28 mm for more complex PPN and H&N plans. For all treatment sites confidence intervals for RMS errors with the overshoot was set at 0-0.50 mm and for the percentage of pixels passing a gamma analysis at 1%/1 mm a confidence interval of 68.83% was set also for all treatment sites. This work demonstrates the successful implementation of treatment log files to validate IMRT deliveries and how dynamic log files can diagnose delivery errors not possible with phantom based QC. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.
Resumo:
Background: One strategy to improve pain management in long term care (LTC) is to optimize the emerging role of the nurse practitioner (NP) in LTC. The purpose of this sub study was to learn about the NP role in implementing an onsite, interdisciplinary Pain Team in the LTC home setting.
Methods: We used a case study design that included two NPs who worked at separate LTC homes. Each of the NPs completed a weekly questionnaire of pain-related activities that they engaged in over a one-year implementation period; and a diary, using critical reflection, about their experiences and strategies used to implement the Pain Team. Descriptive statistics and thematic content analysis were used to analyze the case study data.
Findings: NPs tended to be most engaged in pain assessment and collaborated more with licensed nurses and personal support workers; less with pharmacists. NPs were more involved in organizational level activities, such as participating in committee work or assisting with the development of policies and procedures about pain. NPs created palliative care and pain service protocols; engaged in policy development, in-servicing, quality assurance and advocacy; and encouraged best practices. NPs were challenged with time constraints for pain management and balancing other role priorities and felt that increased scope of practice for them was needed.
Conclusions: The results of this study highlight how NPs implemented a Pain Team in LTC which may be helpful to others interested in implementing a similar strategy to reduce residents’ pain.
Resumo:
The motivation for this study was to reduce physics workload relating to patient- specific quality assurance (QA). VMAT plan delivery accuracy was determined from analysis of pre- and on-treatment trajectory log files and phantom-based ionization chamber array measurements. The correlation in this combination of measurements for patient-specific QA was investigated. The relationship between delivery errors and plan complexity was investigated as a potential method to further reduce patient-specific QA workload. Thirty VMAT plans from three treatment sites - prostate only, prostate and pelvic node (PPN), and head and neck (H&N) - were retrospectively analyzed in this work. The 2D fluence delivery reconstructed from pretreatment and on-treatment trajectory log files was compared with the planned fluence using gamma analysis. Pretreatment dose delivery verification was also car- ried out using gamma analysis of ionization chamber array measurements compared with calculated doses. Pearson correlations were used to explore any relationship between trajectory log file (pretreatment and on-treatment) and ionization chamber array gamma results (pretreatment). Plan complexity was assessed using the MU/ arc and the modulation complexity score (MCS), with Pearson correlations used to examine any relationships between complexity metrics and plan delivery accu- racy. Trajectory log files were also used to further explore the accuracy of MLC and gantry positions. Pretreatment 1%/1 mm gamma passing rates for trajectory log file analysis were 99.1% (98.7%-99.2%), 99.3% (99.1%-99.5%), and 98.4% (97.3%-98.8%) (median (IQR)) for prostate, PPN, and H&N, respectively, and were significantly correlated to on-treatment trajectory log file gamma results (R = 0.989, p < 0.001). Pretreatment ionization chamber array (2%/2 mm) gamma results were also significantly correlated with on-treatment trajectory log file gamma results (R = 0.623, p < 0.001). Furthermore, all gamma results displayed a significant correlation with MCS (R > 0.57, p < 0.001), but not with MU/arc. Average MLC position and gantry angle errors were 0.001 ± 0.002 mm and 0.025° ± 0.008° over all treatment sites and were not found to affect delivery accuracy. However, vari- ability in MLC speed was found to be directly related to MLC position accuracy. The accuracy of VMAT plan delivery assessed using pretreatment trajectory log file fluence delivery and ionization chamber array measurements were strongly correlated with on-treatment trajectory log file fluence delivery. The strong corre- lation between trajectory log file and phantom-based gamma results demonstrates potential to reduce our current patient-specific QA. Additionally, insight into MLC and gantry position accuracy through trajectory log file analysis and the strong cor- relation between gamma analysis results and the MCS could also provide further methodologies to both optimize the VMAT planning and QA process.
Resumo:
Title Evaluation of Video Presentation to Deliver Surgical Anatomy Teaching
Authors Walsh I.K., Boohan M., Dorman A.
Objectives To evaluate the efficacy of newly introduced video presentation to deliver Surgical Anatomy teaching to undergraduate medical students.
Design and Setting Qualitative and quantitative study using questionnaires and focus groups, employing students undertaking the perioperative medicine module of the phase 4 undergraduate medical curriculum at Queen’s University Belfast.
Outcome Measures To determine:
(1) if video presentation is effective in delivering surgical anatomy teaching,
(2) student’s learning preferences regarding this teaching method.
Results The questionnaire response rate was 89% (216 of 244 students; female: male ratio 1.25) and 42 students participated in 6 focus groups. Mean questionnaire responses indicated a favourable opinion on quality assurance items, with a mixed response to video presentation as a learning method. 71% of students preferred to receive a lecture in person, rather than via video presentation. There were no statistically significant differences between genders regarding learning preferences in general and regarding video versus live presentation in particular. Exploratory factor analysis demonstrated that favourable responses to video presentation were strongly associated with perceived audiovisual quality and learning preferences (Cronbach’s alpha coefficient 0.77), with 72% of students considering video presentation worthwhile. Positive perception of overall quality was strongly associated with learning preferences as well as more generic quality assurance issues (80% students; alpha coefficient 0.83).
The results were supported by triangulation of the above quantitative data with qualitative data generated by the focus groups. Students further articulated the view that video presentation may be more appropriate and effective in a mixed method setting.
Reference Basu Roy R, McMahon GT. Video-based cases disrupt deep critical thinking in problem-based learning. Med Educ 2012 Apr;46(4):426-435.
Resumo:
Title Evaluation of Multidisciplinary Delivery of Surgical Anatomy Teaching
Authors Walsh I.K., Taylor S.J., Dorman A, Boohan M.
Objectives To evaluate the efficacy of newly introduced multidisciplinary methods to deliver Surgical Anatomy teaching to undergraduate medical students.
Design and Setting Qualitative and quantitative study using questionnaires and focus groups, employing students of the perioperative and emergency medicine (POEM) module of the phase 4 undergraduate medical curriculum at Queen’s University Belfast.
Outcome Measures To determine:
(1) if multidisciplinary teaching is effective in delivering surgical anatomy teaching,
(2) student’s learning preferences regarding this teaching method.
Results The questionnaire response rate was 89% (216 of 244 students; female: male ratio 1.25) and 42 students participated in 6 focus groups. Mean questionnaire responses indicated a favourable opinion on quality assurance items and multidisciplinary teaching. 81% of students agreed that multidisciplinary teaching enhanced learning and 86% felt that this did not adversely affect interaction. A positive contribution towards POEM learning was reported for Radiology (95% of students), Anatomy (93%) and Surgery (78%). The benefits of multidisciplinary teaching were congruent for Anatomy, Radiology and Surgery with 78% of students indicating a perceived favourable association with learning. Multidisciplinary teaching was not associated with diluted interaction, with 62% of students describing interaction as sufficient. 88% of students positively ranked tutor characteristics of enthusiasm and encouragement as being strongly associated with teacher quality. Positive perception of overall quality was strongly associated with learning preferences as well as more generic quality assurance issues (80% students; alpha coefficient 0.83).
The results were supported by triangulation of the above quantitative data with qualitative data generated by the focus groups. Whilst students frequently misunderstood the meaning of “multidisciplinary teaching”, there was an appreciation of the method’s worth; students recognised and valued the relevance of Anatomy, Radiology and Surgery teaching to POEM learning. The importance of vertically integrating Anatomy into all stages of the undergraduate curriculum was especially recognised.
Reference Aarnio M, Nieminen J, Pyorala E, Lindbolm-Ylanne S. Motivating medical students to learn. 2010 Med Teach;32(4):199-204.
Resumo:
Implications Provision of environmental enrichment in line with that required by welfare-based quality assurance schemesdoes not always appear to lead to clear improvements in broiler chicken welfare. This research perhaps serves to highlightthe deficit in information regarding the ‘real world’ implications of enrichment with perches, string and straw bales.
Introduction Earlier work showed that provision of natural light and straw bales improved leg health in commercial broilerchickens (Bailie et al., 2013). This research aimed to determine if additional welfare benefits were shown in windowedhouses by increasing straw bale provision (Study 1), or by providing perches and string in addition to straw bales (Study 2).
Material and methods Commercial windowed houses in Northern Ireland containing ~23,000 broiler chickens (placed inhouses as hatched) were used in this research which took place in 2011. In Study 1 two houses on a single farm wereassigned to one of two treatments: (1) 30 straw bales per house (1 bale/44m2), or (2) 45 straw bales per house (1bale/29m2). Bales of wheat straw, each measuring 80cm x 40cm x 40cm were provided from day 10 of the rearing cycle,as in Bailie et al. (2013). Treatments were replicated over 6 production cycles (using 276,000 Ross 308 and Cobb birds),and were swapped between houses in each replicate. In Study 2, four houses on a single farm were assigned to 1 of 4treatments in a 2 x 2 factorial design. Treatments involved 2 levels of access to perches (present (24/house), or absent), and2 levels of access to string (present (24/house), or absent), and both types of enrichment were provided from the start of thecycle. Each perch consisted of a horizontal, wooden beam (300 cm x 5 cm x 5cm) with a rounded upper edge resting on 2supports (15 cm high). In the string treatment, 6 pieces of white nylon string (60 cm x 10 mm) were tied at their mid-pointto the wire above each of 4 feeder lines. Thirty straw bales were also provided per house from day 10. This study wasreplicated over 4 production cycles using 368,000 Ross 308 birds. In both studies behaviour was observed between 0900and 1800 hours in weeks 3-5 of the cycle. In Study 1, 8 focal birds were selected in each house each week, and generalactivity, exploratory and social behaviours recorded directly for 10 minutes. In Study 2, 10 minute video recordings weremade of 6 different areas (that did not contain enrichment) of each house each week. The percentage of birds engaged inlocomotion or standing was determined through scan sampling these recordings at 120 second intervals. Four perches andfour pieces of string were filmed for 25 mins in each house that contained these enrichments on one day per week. The totalnumber of times the perch or string was used was recorded, along with the duration of each bout. In both studies, gaitscores (0 (perfect) to 5 (unable to walk)) and latency to lie (measured in seconds from when a bird had been encouraged tostand) were recorded in 25 birds in each house each week. Farm and abattoir records were also used in both studies todetermine the number of birds culled for leg and other problems, mortality levels, slaughter weights, and levels of pododermatitis and hock burn. Data were analysed using SPSS (version 20.0) and treatment and age effects on behaviouralparameters were determined in normally distributed data using ANOVA (‘Straw bale density*week’, or‘string*perches*week’ as appropriate), and in non-normally distributed data using Kuskall-Wallace tests (P<0.05 forsignificance) . Treatment (but not age) effects on performance and health data were determined using the same testsdepending on normality of data.
Results Average slaughter weight, and levels of mortality, culling, hock burn and pododermatitis were not affected bytreatment in either study (P<0.05). In Study 1 straw bale (SB) density had no significant effect on the frequency orduration of behaviours including standing, walking, ground pecking, dust bathing, pecking at bales or aggression, or onaverage gait score (P>0.05). However, the average latency to lie was greater when fewer SB were provided (30SB 23.38s,45SB 18.62s, P<0.01). In Study 2 there was an interaction between perches (Pe) and age in lying behaviour, with higherpercentages of birds observed lying in the Pe treatment during weeks 4 and 5 (week 3 +Pe 77.0 -Pe 80.9, week 4 +Pe 79.5 -Pe 75.2, week 5 +Pe 78.4 -Pe 76.2, P<0.02). There was also a significant interaction between string (S) and age inlocomotory behaviour, with higher percentages of birds observed in locomotion in the string treatment during week 3 butnot weeks 4 and 5 (week 3 +S 4.9 -S 3.9, week 4 +S 3.3 -S 3.7, week 5 +S 2.6 -S 2.8, P<0.04). There was also aninteraction between S and age in average gait scores, with lower gait scores in the string treatment in weeks 3 and 5 (week3: +S 0.7, -S 0.9, week 4: +S 1.5, -S 1.4, week 5: +S 1.9, -S 2.0, P<0.05). On average per 25 min observation there were15.1 (±13.6) bouts of perching and 19.2 (±14.08) bouts of string pecking, lasting 117.4 (±92.7) and 4.2 (±2.0) s for perchesand string, respectively.
Conclusion Increasing straw bale levels from 1 bale/44m2 to 1 bale/29m2 floor space does not appear to lead to significantimprovements in the welfare of broilers in windowed houses. The frequent use of perches and string suggests that thesestimuli have the potential to improve welfare. Provision of string also appeared to positively influence walking ability.However, this effect was numerically small, was only shown in certain weeks and was not reflected in the latency to lie.Further research on optimum design and level of provision of enrichment items for broiler chickens is warranted. Thisshould include measures of overall levels of activity (both in the vicinity of, and away from, enrichment items).