992 resultados para Architecture for a Free Subjectivity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the potential of free-breathing 3D steady-state free precession (SSFP) imaging with radial k-space sampling for coronary MR-angiography (MRA), coronary projection MR-angiography and coronary vessel wall imaging. MATERIALS AND METHODS: A navigator-gated free-breathing T2-prepared 3D SSFP sequence (TR = 6.1 ms, TE = 3.0 ms, flip angle = 120 degrees, field-of-view = 360 mm(2)) with radial k-space sampling (384 radials) was implemented for coronary MRA. For projection coronary MRA, this sequence was combined with a 2D selective aortic spin tagging pulse. Coronary vessel wall imaging was performed using a high-resolution inversion-recovery black-blood 3D radial SSFP sequence (384 radials, TR = 5.3 ms, TE = 2.7 ms, flip angle = 55 degrees, reconstructed resolution 0.35 x 0.35 x 1.2 mm(3)) and a local re-inversion pulse. Six healthy volunteers (two for each sequence) were investigated. Motion artifact level was assessed by two radiologists. Results: In coronary MRA, the coronary lumen was displayed with a high signal and high contrast to the surrounding lumen. Projection coronary MRA demonstrated selective visualization of the coronary lumen while surrounding tissue was almost completely suppressed. In coronary vessel wall imaging, the vessel wall was displayed with a high signal when compared to the blood pool and the surrounding tissue. No visible motion artifacts were seen. Conclusion: 3D radial SSFP imaging enables coronary MRA, coronary projection MRA and coronary vessel wall imaging with a low motion artifact level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). METHODS AND RESULTS: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1:1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis.Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02±3.06 mm(2)to 8.47±3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39±2.73 mm(2)to 4.78±2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). CONCLUSIONS PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the increasing popularity of enterprise architecture management (EAM) in practice, many EAM initiatives either do not fully meet the expected targets or fail. Several frameworks have been suggested as guidelines to EA implementation, but companies seldom follow prescriptive frameworks. Instead, they follow very diverse implementation approaches that depend on their organizational contingencies and the way of adopting and evolving EAM over time. This research strives for a broader understanding of EAM by exploring context-dependent EAM adoption approaches as well as identifying the main EA principles that affect EA effectiveness. Based on two studies, this dissertation aims to address two main questions: (1) EAM design: Which approaches do companies follow when adopting EAM? (2) EA principles and their impact: What impact does EA principles have on EA effectiveness/quality? By utilizing both qualitative and quantitative research methods, this research contributes to exploring different EAM designs in different organizational contingencies as well as using EA principles as an effective means to achieve principle-based EAM design. My research can help companies identify a suitable EAM design that fits their organizational settings and shape their EA through a set of principles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Platelet free cytosolic calcium (PFCC) was measured in 21 healthy volunteers before and after cigarette smoking or physical exercise. The aim was to investigate whether acute blood pressure changes and increases in circulating levels of catecholamines and vasopressin modify PFCC. PFCC was determined using the Quin-2 method. Following cigarette smoking, significant increases in blood pressure, heart rate, plasma epinephrine (35 +/- 18 pg/ml before versus 51 +/- 31 pg/ml after smoking, P less than 0.05, mean +/- s.d.) and vasopressin levels (0.8 +/- 0.3 pg/ml before and 4.2 +/- 4.1 pg/ml after smoking, P less than 0.001) were observed. However, despite these acute hormonal and hemodynamic changes, PFCC remained stable at 156 +/- 55 nmol/l prior to the study and 157 +/- 29 nmol/l and 156 +/- 38 nmol/l at 20 and 80 min post-smoking, respectively. Acute physical exercise led to an increase in heart rate and systolic blood pressure but to a decrease in diastolic pressure. Moreover, a marked increase in plasma norepinephrine levels was observed after exercise (213 +/- 71 pg/ml before versus 747 +/- 501 pg/ml after exercise, P +/- 0.001). Again, PFCC was stable at 185 +/- 56 nmol/l at baseline versus 188 +/- 51 nmol/l at 20 min and 155 +/- 26 nmol/l at 80 min after exercise. These results therefore demonstrate that PFCC is not influenced acutely either by blood pressure increases, or by elevations in circulating catecholamine and vasopressin concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/objectives:Bioelectrical impedance analysis (BIA) is used in population and clinical studies as a technique for estimating body composition. Because of significant under-representation in existing literature, we sought to develop and validate predictive equation(s) for BIA for studies in populations of African origin.Subjects/methods:Among five cohorts of the Modeling the Epidemiologic Transition Study, height, weight, waist circumference and body composition, using isotope dilution, were measured in 362 adults, ages 25-45 with mean body mass indexes ranging from 24 to 32. BIA measures of resistance and reactance were measured using tetrapolar placement of electrodes and the same model of analyzer across sites (BIA 101Q, RJL Systems). Multiple linear regression analysis was used to develop equations for predicting fat-free mass (FFM), as measured by isotope dilution; covariates included sex, age, waist, reactance and height(2)/resistance, along with dummy variables for each site. Developed equations were then tested in a validation sample; FFM predicted by previously published equations were tested in the total sample.Results:A site-combined equation and site-specific equations were developed. The mean differences between FFM (reference) and FFM predicted by the study-derived equations were between 0.4 and 0.6âeuro0/00kg (that is, 1% difference between the actual and predicted FFM), and the measured and predicted values were highly correlated. The site-combined equation performed slightly better than the site-specific equations and the previously published equations.Conclusions:Relatively small differences exist between BIA equations to estimate FFM, whether study-derived or published equations, although the site-combined equation performed slightly better than others. The study-derived equations provide an important tool for research in these understudied populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess total free-living energy expenditure (EE) in Gambian farmers with two independent methods, and to determine the most realistic free-living EE and physical activity in order to establish energy requirements for rural populations in developing countries. DESIGN: In this cross-sectional study two methods were applied at the same time. SETTING: Three rural villages and Dunn Nutrition Centre Keneba, MRC, The Gambia. SUBJECTS: Eight healthy, male subjects were recruited from three rural Gambian villages in the sub-Sahelian area (age: 25 +/- 4y; weight: 61.2 +/- 10.1 kg; height: 169.5 +/- 6.5 cm, body mass index: 21.2 +/- 2.5 kg/m2). INTERVENTION: We assessed free-living EE with two inconspicuous and independent methods: the first one used doubly labeled water (DLW) (2H2 18O) over a period of 12 days, whereas the second one was based on continuous heart rate (HR) measurements on two to three days using individual regression lines (HR vs EE) established by indirect calorimetry in a respiration chamber. Isotopic dilution of deuterium (2H2O) was also used to assess total body water and hence fat-free mass (FFM). RESULTS: EE assessed by DLW was found to be 3880 +/- 994 kcal/day (16.2 +/- 4.2 MJ/day). Expressed per unit body weight the EE averaged 64.2 +/- 9.3 kcal/kg/d (269 +/- 38 kJ/kg/d). These results were consistent with the EE results assessed by HR: 3847 +/- 605 kcal/d (16.1 +/- 2.5 MJ/d) or 63.4 +/- 8.2 kcal/kg/d (265 +/- 34kJ/kg/d). Physical activity index, expressed as a multiple of basal metabolic rate (BMR), averaged 2.40 +/- 0.41 (DLW) or 2.40 +/- 0.28 (HR). CONCLUSIONS: These findings suggest an extremely high level of physical activity in Gambian men during intense agricultural work (wet season). This contrasts with the relative food shortage, previously reported during the harvesting period. We conclude that the assessment of EE during the agricultural season in non-industrialized countries needs further investigations in order to obtain information on the energy requirement of these populations. For this purpose the use of the DLW and HR methods have been shown to be useful and complementary.