946 resultados para time measurement
Resumo:
A fast and automatic method for radiocarbon analysis of aerosol samples is presented. This type of analysis requires high number of sample measurements of low carbon masses, but accepts precisions lower than for carbon dating analysis. The method is based on online Trapping CO2 and coupling an elemental analyzer with a MICADAS AMS by means of a gas interface. It gives similar results to a previously validated reference method for the same set of samples. This method is fast and automatic and typically provides uncertainties of 1.5–5% for representative aerosol samples. It proves to be robust and reliable and allows for overnight and unattended measurements. A constant and cross contamination correction is included, which indicates a constant contamination of 1.4 ± 0.2 μg C with 70 ± 7 pMC and a cross contamination of (0.2 ± 0.1)% from the previous sample. A Real-time online coupling version of the method was also investigated. It shows promising results for standard materials with slightly higher uncertainties than the Trapping online approach.
Resumo:
Abstract: Near-infrared spectroscopy (NIRS) enables the non-invasive measurement of changes in hemodynamics and oxygenation in tissue. Changes in light-coupling due to movement of the subject can cause movement artifacts (MAs) in the recorded signals. Several methods have been developed so far that facilitate the detection and reduction of MAs in the data. However, due to fixed parameter values (e.g., global threshold) none of these methods are perfectly suitable for long-term (i.e., hours) recordings or were not time-effective when applied to large datasets. We aimed to overcome these limitations by automation, i.e., data adaptive thresholding specifically designed for long-term measurements, and by introducing a stable long-term signal reconstruction. Our new technique (“acceleration-based movement artifact reduction algorithm”, AMARA) is based on combining two methods: the “movement artifact reduction algorithm” (MARA, Scholkmann et al. Phys. Meas. 2010, 31, 649–662), and the “accelerometer-based motion artifact removal” (ABAMAR, Virtanen et al. J. Biomed. Opt. 2011, 16, 087005). We describe AMARA in detail and report about successful validation of the algorithm using empirical NIRS data, measured over the prefrontal cortex in adolescents during sleep. In addition, we compared the performance of AMARA to that of MARA and ABAMAR based on validation data.
Resumo:
Ultrastructural analysis of the polydnavirus of the braconid wasp Chelonus inanitus revealed that virions consist of one cylindrical nucleocapsid enveloped by a single unit membrane. Nucleocapsids have a constant diameter of 33.7 +/- 1.4 nm and a variable length of between 8 and 46 nm. Spreading of viral DNA showed that the genome consists of circular dsDNA molecules of variable sizes and measurement of the contour lengths indicated sizes of between 7 and 31 kbp. When virions were exposed to osmotic shock conditions to release the DNA, only one circular molecule was released per particle suggesting that the various DNA molecules are singly encapsidated in this bracovirus. The viral genome was seen to consist of at least 10 different segments and the aggregate genome size is in the order of 200 kbp. By partial digestion of viral DNA with HindIII or EcoRI in the presence of ethidium bromide and subsequent ligation with HindIII-cut pSP65 or EcoRI-cut pSP64 and transfection into Escherichia coli, libraries of 103 HindIII and 23 EcoRI clones were obtained. Southern blots revealed that complete and unrearranged segments were cloned with this approach, and restriction maps for five segments were obtained. Part of a 16.8 kbp segment was sequenced, found to be AT-rich (73%) and to contain six copies of a 17 bp repeated sequence. The development of the female reproductive tract in the course of pupal-adult development of the wasp was investigated and seen to be strictly correlated with the pigmentation pattern. By the use of a semiquantitative PCR, replication of viral DNA was observed to initiate at a specific stage of pupal-adult development.
Resumo:
Stratospheric ozone is of major interest as it absorbs most harmful UV radiation from the sun, allowing life on Earth. Ground-based microwave remote sensing is the only method that allows for the measurement of ozone profiles up to the mesopause, over 24 hours and under different weather conditions with high time resolution. In this paper a novel ground-based microwave radiometer is presented. It is called GROMOS-C (GRound based Ozone MOnitoring System for Campaigns), and it has been designed to measure the vertical profile of ozone distribution in the middle atmosphere by observing ozone emission spectra at a frequency of 110.836 GHz. The instrument is designed in a compact way which makes it transportable and suitable for outdoor use in campaigns, an advantageous feature that is lacking in present day ozone radiometers. It is operated through remote control. GROMOS-C is a total power radiometer which uses a pre-amplified heterodyne receiver, and a digital fast Fourier transform spectrometer for the spectral analysis. Among its main new features, the incorporation of different calibration loads stands out; this includes a noise diode and a new type of blackbody target specifically designed for this instrument, based on Peltier elements. The calibration scheme does not depend on the use of liquid nitrogen; therefore GROMOS-C can be operated at remote places with no maintenance requirements. In addition, the instrument can be switched in frequency to observe the CO line at 115 GHz. A description of the main characteristics of GROMOS-C is included in this paper, as well as the results of a first campaign at the High Altitude Research Station at Jungfraujoch (HFSJ), Switzerland. The validation is performed by comparison of the retrieved profiles against equivalent profiles from MLS (Microwave Limb Sounding) satellite data, ECMWF (European Centre for Medium-Range Weather Forecast) model data, as well as our nearby NDACC (Network for the Detection of Atmospheric Composition Change) ozone radiometer measuring at Bern.
Resumo:
The ECHo Collaboration (Electron Capture 163Ho aims to investigate the calorimetric spectrum following the electron capture decay of 163Ho to determine the mass of the electron neutrino. The size of the neutrino mass is reflected in the endpoint region of the spectrum, i.e., the last few eV below the transition energy. To check for systematic uncertainties, an independent determination of this transition energy, the Q-value, is mandatory. Using the TRIGA-TRAP setup, we demonstrate the feasibility of performing this measurement by Penning-trap mass spectrometry. With the currently available, purified 163Ho sample and an improved laser ablation mini-RFQ ion source, we were able to perform direct mass measurements of 163Ho and 163Dy with a sample size of less than 1017 atoms. The measurements were carried out by determining the ratio of the cyclotron frequencies of the two isotopes to those of carbon cluster ions using the time-of-flight ion cyclotron resonance method. The obtained mass excess values are ME(163Ho)= −66379.3(9) keV and ME(163Dy)= −66381.7(8) keV. In addition, the Q-value was measured for the first time by Penning-trap mass spectrometry to be Q = 2.5(7) keV.
Resumo:
BACKGROUND The aim of newborn screening (NBS) for CF is to detect children with 'classic' CF where early treatment is possible and improves prognosis. Children with inconclusive CF diagnosis (CFSPID) should not be detected, as there is no evidence for improvement through early treatment. No algorithm in current NBS guidelines explains what to do when sweat test (ST) fails. This study compares the performance of three different algorithms for further diagnostic evaluations when first ST is unsuccessful, regarding the numbers of children detected with CF and CFSPID, and the time until a definite diagnosis. METHODS In Switzerland, CF-NBS was introduced in January 2011 using an IRT-DNA-IRT algorithm followed by a ST. In children, in whom ST was not possible (no or insufficient sweat), 3 different protocols were applied between 2011 and 2014: in 2011, ST was repeated until it was successful (protocol A), in 2012 we proceeded directly to diagnostic DNA testing (protocol B), and 2013-2014, fecal elastase (FE) was measured in the stool, in order to determine a pancreas insufficiency needing immediate treatment (protocol C). RESULTS The ratio CF:CFSPID was 7:1 (27/4) with protocol A, 2:1 (22/10) with protocol B, and 14:1 (54/4) with protocol C. The mean time to definite diagnosis was significantly shorter with protocol C (33days) compared to protocol A or B (42 and 40days; p=0.014 compared to A, and p=0.036 compared to B). CONCLUSIONS The algorithm for the diagnostic part of the newborn screening used in the CF centers is important and affects the performance of a CF-NBS program with regard to the ratio CF:CFSPID and the time until definite diagnosis. Our results suggest to include FE after initial sweat test failure in the CF-NBS guidelines to keep the proportion of CFSPID low and the time until definite diagnosis short.
Resumo:
INTRODUCTION Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest-based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term-born infants and infants with lung disease by the vest-based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease. METHODS Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current-carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest-based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared. RESULTS We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest-based system was significantly lower with a mean difference (95% CI) of -1.33 ml/kg (-1.73; -0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE. CONCLUSION FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements.
Resumo:
In situ and simultaneous measurement of the three most abundant isotopologues of methane using mid-infrared laser absorption spectroscopy is demonstrated. A field-deployable, autonomous platform is realized by coupling a compact quantum cascade laser absorption spectrometer (QCLAS) to a preconcentration unit, called trace gas extractor (TREX). This unit enhances CH4 mole fractions by a factor of up to 500 above ambient levels and quantitatively separates interfering trace gases such as N2O and CO2. The analytical precision of the QCLAS isotope measurement on the preconcentrated (750 ppm, parts-per-million, µmole mole−1) methane is 0.1 and 0.5 ‰ for δ13C- and δD-CH4 at 10 min averaging time. Based on repeated measurements of compressed air during a 2-week intercomparison campaign, the repeatability of the TREX–QCLAS was determined to be 0.19 and 1.9 ‰ for δ13C and δD-CH4, respectively. In this intercomparison campaign the new in situ technique is compared to isotope-ratio mass spectrometry (IRMS) based on glass flask and bag sampling and real time CH4 isotope analysis by two commercially available laser spectrometers. Both laser-based analyzers were limited to methane mole fraction and δ13C-CH4 analysis, and only one of them, a cavity ring down spectrometer, was capable to deliver meaningful data for the isotopic composition. After correcting for scale offsets, the average difference between TREX–QCLAS data and bag/flask sampling–IRMS values are within the extended WMO compatibility goals of 0.2 and 5 ‰ for δ13C- and δD-CH4, respectively. This also displays the potential to improve the interlaboratory compatibility based on the analysis of a reference air sample with accurately determined isotopic composition.
Resumo:
Research has shown that physical activity serves a preventive function against the development of several major chronic diseases. However, studying physical activity and its health benefits is difficult due to the complexity of measuring physical activity. The overall aim of this research is to contribute to the knowledge of both correlates and measurement of physical activity. Data from the Women On The Move study were used for this study (n = 260), and the results are presented in three papers. The first paper focuses on the measurement of physical activity and compares an alternate coding method with the standard coding method for calculating energy expenditure from a 7-day activity diary. Results indicate that the alternative coding scheme could produce similar results to the standard coding in terms of total activity expenditure. Even though agreement could not be achieved by dimension, the study lays the groundwork for a coding system that saves considerable amount of time in coding activity and has the ability to estimate expenditure more accurately for activities that can be performed at varying intensity levels. The second paper investigates intra-day variability in physical activity by estimating the variation in energy expenditure for workers and non-workers and identifying the number of days of diary self-report necessary to reliably estimate activity. The results indicate that 8 days of activity are needed to reliably estimate total activity for individuals who don't work and 12 days of activity are needed to reliably estimate total activity for those who work. Days of diary self-report required by dimension for those who don't work range from 6 to 16 and for those who work from 6 to 113. The final paper presents findings on the relationship between daily living activity and Type A behavior pattern. Significant findings are observed for total activity and leisure activity with the Temperament Scale summary score. Significant findings are also observed for total activity, household chores, work, leisure activity, exercise, and inactivity with one or more of the individual items on the Temperament Scale. However, even though some significant findings were observed, the overall models did not reveal meaningful associations. ^
Resumo:
Arterial spin labeling (ASL) is a technique for noninvasively measuring cerebral perfusion using magnetic resonance imaging. Clinical applications of ASL include functional activation studies, evaluation of the effect of pharmaceuticals on perfusion, and assessment of cerebrovascular disease, stroke, and brain tumor. The use of ASL in the clinic has been limited by poor image quality when large anatomic coverage is required and the time required for data acquisition and processing. This research sought to address these difficulties by optimizing the ASL acquisition and processing schemes. To improve data acquisition, optimal acquisition parameters were determined through simulations, phantom studies and in vivo measurements. The scan time for ASL data acquisition was limited to fifteen minutes to reduce potential subject motion. A processing scheme was implemented that rapidly produced regional cerebral blood flow (rCBF) maps with minimal user input. To provide a measure of the precision of the rCBF values produced by ASL, bootstrap analysis was performed on a representative data set. The bootstrap analysis of single gray and white matter voxels yielded a coefficient of variation of 6.7% and 29% respectively, implying that the calculated rCBF value is far more precise for gray matter than white matter. Additionally, bootstrap analysis was performed to investigate the sensitivity of the rCBF data to the input parameters and provide a quantitative comparison of several existing perfusion models. This study guided the selection of the optimum perfusion quantification model for further experiments. The optimized ASL acquisition and processing schemes were evaluated with two ASL acquisitions on each of five normal subjects. The gray-to-white matter rCBF ratios for nine of the ten acquisitions were within ±10% of 2.6 and none were statistically different from 2.6, the typical ratio produced by a variety of quantitative perfusion techniques. Overall, this work produced an ASL data acquisition and processing technique for quantitative perfusion and functional activation studies, while revealing the limitations of the technique through bootstrap analysis. ^
Resumo:
The purpose of this investigation was to develop a reliable scale to measure the social environment of hospital nursing units according to the degree of humanistic and dehumanistic behaviors as perceived by nursing staff in hospitals. The study was based on a conceptual model proposed by Jan Howard, a sociologist. After reviewing the literature relevant to personalization of care, analyzing interviews with patients in various settings, and studying biological, psychological, and sociological frames of reference, Howard proposed the following necessary conditions for humanized health care. They were the dimensions of Irreplaceability, Holistic Selves, Freedom of Action, Status Equality, Shared Decision Making and Responsibility, Empathy, and Positive Affect.^ It was proposed that a scale composed of behaviors which reflected Howard's dimensions be developed within the framework of the social environment of nursing care units in hospitals. Nursing units were chosen because hospitals are traditionally organized around nursing care units and because patients spend the majority of their time in hospitals interacting with various levels of nursing personnel.^ Approximately 180 behaviors describing both patient and nursing staff behaviors which occur on nursing units were developed. Behaviors which were believed to be humanistic as well as dehumanistic were included. The items were classified under the dimensions of Howard's model by a purposively selected sample of 42 nurses representing a broad range of education, experience, and clinical areas. Those items with a high degree of agreement, at least 50%, were placed in the questionnaire. The questionnaire consisted of 169 items including six items from the Marlowe Crowne Social Desirability Scale (Short Form).^ The questionnaire, the Social Environment Scale, was distributed to the entire 7 to 3 shift nursing staff (603) of four hospitals including a public county specialty hospital, a public county general and acute hospital, a large university affiliated hospital with all services, and a small general community hospital. Staff were asked to report on a Likert type scale how often the listed behaviors occurred on their units. Three hundred and sixteen respondents (52% of the population) participated in the study.^ An item analysis was done in which each item was examined in relationship to its correlation to its own dimension total and to the totals of the other dimensions. As a result of this analysis, three dimensions, Positive Affect, Irreplaceability, and Freedom of Action were deleted from the scale. The final scale consisted of 70 items with 26 in Shared Decision Making and Responsibility, 25 in Holistic Selves, 12 in Status Equality, and seven in Empathy. The alpha coefficient was over .800 for all scales except Empathy which was .597.^ An analysis of variance by hospital was performed on the means of each dimension of the scale. There was a statistically significant difference between hospitals with a trend for the public hospitals to score lower on the scale than the university or community hospitals. That the scale scores should be lower in crowded, understaffed public hospitals was not unexpected and reflected that the scale had some discriminating ability. These differences were still observed after adjusting for the effect of Social Desirability.^ In summary, there is preliminary evidence based on this exploratory investigation that a reliable scale based on at least four dimensions from Howard's model could be developed to measure the concept of humanistic health care in hospital settings. ^