839 resultados para Rivet-fastened rectangular hollow flange channel beam (RHFCB)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to optimize the parameter setup for GTAW of aluminum using an AC rectangular wave output and continuous feeding. A series of welds was carried-out in an industrial joint, with variation of the negative and positive current amplitude, the negative and positive duration time, the travel speed and the feeding speed. Another series was carried out to investigate the isolate effect of the negative duration time and travel speed. Bead geometry aspects were assessed, such as reinforcement, penetration, incomplete fusion and joint wall bridging. The results showed that currents at both polarities are remarkably more significant than the respective duration times. It was also shown that there is a straight relationship between welding speed and feeding speed and this relationship must be followed for obtaining sound beads. A very short positive duration time is enough for arc stability achievement and when the negative duration time is longer than 5 ms its effect on geometry appears. The possibility of optimizing the parameter selection, despite the high inter-correlation amongst them, was demonstrate through a computer program. An approach to reduce the number of variables in this process is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This contribution discusses the nonlinear dynamics of a pin-ended elasto-plastic beam with both kinematic and isotropic hardening. An iterative numerical procedure based on the operator split technique is developed in order to deal with the nonlinearities in the equations of motion. Free and forced responses for harmonic sinusoidal and square wave excitations are investigated. Numerical simulations present many interesting behaviors such as jump phenomena, sensitivity to initial conditions, chaos and transient chaos. These results indicate that there are practical problems in predicting the response of the beam even when periodic steady state response is expected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Composite flooring systems supported by tapered (varying web depth) beams are very attractive from an economic point of view. However, the tapered beam sections are fabricated from plate by welding, and are susceptible to imperfection effects. These may interact with the localised compressive stress field that is generated in the web at a slope change in the lower flange to cause local web buckling. A substantial parametric study using a non-linear elasto-plastic finite element program and covering practical ranges of the important parameters including the area of the tension flange, taper slope and web thickness is reported. Moment-rotation relations, peak moments and failure mechanisms have been predicted. The validity of the work is supported by the good correlation obtained between the results of the parametric study and experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper applies the Multi-Harmonic Nonlinear Receptance Coupling Approach (MUHANORCA) (Ferreira 1998) to evaluate the frequency response characteristics of a beam which is clamped at one end and supported at the other end by a nonlinear cubic stiffness joint. In order to apply the substructure coupling technique, the problem was characterised by coupling a clamped linear beam with a nonlinear cubic stiffness joint. The experimental results were obtained by a sinusoidal excitation with a special force control algorithm where the level of the fundamental force is kept constant and the level of the harmonics is kept zero for all the frequencies measured.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä määritettiin pituussuunnassa hitsatun rakenneputken väsymislujuus HF –hitsausta käytettäessä. Työn tavoitteena oli vertailla eri jälkikäsittelyjen ja kahden eri materiaalin vaikutusta väsymislujuuteen. Materiaaleina kokeissa oli Ruukki double grade ja Optim 700 Plus MH. Eurokoodi 3 ja IIW määrittelee kiinnityshitseille väsymiskestävyysluokaksi 125-140, kun SN -käyrän kaltevuus, m = 3. Koetuloksia vertailtiin näihin valmiiksi määriteltyihin väsymiskestävyysluokkiin. Ruukki Metals Oy toimitti koemateriaalin kahdenlaisia väsytyskokeita varten, joiden avulla väsymislujuus voitiin määrittää. Ensimmäinen koe suoritettiin värähtelyllä hyödyntäen rakenneputken ominaistaajuutta, jolloin kuormituksen rajajännityssuhde on -1. Toinen väsytyskoe suoritettiin rakenneputkista leikatuille väsytyssauvoille, missä pituussuuntainen HF –hitsi on keskellä sauvaa. Tämä väsytyskoe suoritettiin vetotykytyksellä rajajännityssuhteella 0,1. Väsytyskokeissa havaittiin, että kiinnityshitsi täyttää sille asetetut vaatimukset, koska murtumat tapahtuivat perusaineesta. Tällöin koetuloksia vertaillaan Eurokoodi 3:n perusaineen väsymisluokkaan 160, SN -käyrän kaltevuudella m = 5. Kaikkien koetulosten väsymiskestävyysluokan keskiarvoksi saatiin 185 95 %:n todennäköisyydellä. Tutkimuksessa saatiin arvokasta tietoa kahden eri materiaalin väsymislujuudesta. Materiaalilla ei kuitenkaan havaittu vaikutusta lujuuteen. Eri jälkikäsittelyt eli juuren puolen metallipurseen höyläys tai pituussuuntaisen hitsisauman hehkutus eivät vaikuttaneet väsymislujuuteen. Kokeissa väsymismurtuma ydintyi rakenneputken pinnalta olevista alkuvioista, joten putkien käsittelyä valmistuksen jälkeen voitaisiin parantaa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of after-sales service or service in general can be seen and experienced by customers every day with industrial as well as other non-industrial services or products. This dissertation, drawing on theory and experience, focuses on practical engineering implications, specifically the management of customer issues in the after-sales phase in the mobile phone arena. The main objective of this doctoral dissertation is to investigate customer after-sales issue management, specifically regarding mobile phones. The case studies focus on issue resolution time and the issue of corrective actions. This dissertation consists of a main body and four peer-reviewed journal articles and one manuscript currently under review by a peer-reviewed journal. The main body of this dissertation examines the elements of customer satisfaction, loyalty, and retention with respect to corrective actions to address customer issues and issue resolution time through literature and empirical studies. The five independent works are case studies supporting the thesis research questions. This study examines four questions: 1) What are the factors affecting corrective actions for customers? 2) How can customer issue resolution time be controlled? 3) What are the factors affecting processes in the service chain? and 4) How can communication be measured in a service chain? In this work, both quantitative and qualitative analysis methods are used. The main body of the thesis reviews the literature regarding the elements that bridge the five case studies. The case studies of the articles and surveys lean more toward the methodology of critical positivism and then apply the interpretive approach in interpreting the results. The case study articles employ various statistical methods to analyze and to interpret the empirical and survey data. The statistical methods were used to create a model that is useful for significantly optimizing issue resolution time. Moreover, it was found that samples for verifying issues provided by the customer neither improve the perceived quality of corrective actions nor the perceived quality of issue resolution time. The term “service” in this work is limited to the technical services that are provided by product manufacturers and after-sales authorized service vendors. On the basis of this research work, it has been observed that corrective actions and issue resolution time are associated with customer satisfaction and hence, according to induction theory, to customer loyalty and retention. This thesis utilizes knowledge of marketing and customer relationships to contribute to the existing body of knowledge concerning information and communication technology for after-sales service recovery of mobile terminals. The established models in the thesis contribute to the existing knowledge of the after-sales process of dealing with customer issues in the field of mobile phones. The findings suggest that process managers could focus more on communication and training provided to the staff as new technology evolves rapidly. The study also suggest the managers formulate strategies for how customers can be kept informed on a regular basis of the status of issues that have been escalated for corrective action. The findings also lay the foundation for the comprehensive objective to control the entire product development process, starting with conceptualization. This implies that robust design should be applied to the new products so that problems affecting customer service quality are not repeated. The objective will be achieved when the entire service chain from product development to the final user can be modeled and this model can be used to support the organization at all levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, the contact resistance of graphene devices was investigated because high contact resistance is detrimental to the performance of graphene field-effect transistors (GFET). Method for increasing so-called edge-contact area was applied in device fabrication process, as few nanometers thick Ni layer was used as a catalytic etchant during the annealing process. Finally, Ni was also used as a metal for contact. GFETs were fabricated using electron beam lithography using graphene fabricated by chemical vapor deposition (CVD). Critical part of the fabrication process was to preserve the high quality of the graphene channel while etching the graphene at contact areas with Ni during the annealing. This was achieved by optimizing the combination of temperature and gas flows. The structural properties of graphene were studied using scanning electron microscopy, scanning confocal μ-Raman spectroscopy and optical microscopy. Evaluation of electric transport properties including contact resistance was carried out by transmission line method and four-probe method. The lowest contact resistance found was about at 350 Ωμm. In addition, different methods to transfer CVD graphene synthesized on copper were studied. Typical method using PMMA as a supporting layer leaves some residues after its removal, thus effecting on the performance of a graphene devices. In a metal assisted transfer method, metal is used as an interfacial layer between PMMA and graphene. This allows more effective removal of PMMA. However, Raman spectra of graphene transferred by metal assisted method showed somewhat lower quality than the PMMA assisted method

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this master’s thesis was to make a qualitative marketing research and on the basis of this to develop a distribution plan for the case company Finnish 3M Ltd.’s wound care products. The literature review includes three important parts: distribution channel planning, the buying behavior of seniors, and special characteristics of health care products’ marketing. The empirical part of this thesis comprises two different parts. The first part is a marketing research, in which the buying behavior of wound care products is studied in Espoo. The research aim was to examine, in which distribution channels the wound care patients under home care would most preferably buy wound care products during the time period, when municipalities will not yet provide the products for free. The data was collected through semi-structured phone interviews and regular interviews, and was treated qualitatively and anonymously. The study revealed that the recommendations of nurses and doctors influenced most the buying behavior of wound care customers. In the second part of the thesis a distribution channel plan for wound care products was made for the case company 3M Finland Ltd. based on the results. 3M Finland Ltd. should focus on pharmacies, online-stores and municipal health centers as their main distributors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In routine studies of sensory nerve conduction, only fibers e7 µm in diameter are analyzed. The late components which originate from thinner fibers are not detected. This explains why a normal sensory action potential (SAP) may be recorded in patients with peripheral neuropathies and sensory loss. In the present study we investigated the late component of the median SAP with a near nerve needle electrode technique in 14 normal volunteers (7 men and 7 women), aged 34.5 ± 14.8 years. The stimulus consisted of rectangular pulses of 0.2-ms duration at a frequency of 1 Hz with an intensity at least 6 times greater than the threshold value for the main component. Five hundred to 2000 sweep averagings were performed. The duration of analysis was 40 or 50 ms and the wave analysis frequency was 200 (-6 dB/oct) to 3000 Hz (-12 dB/oct). We used an apparatus with a two-channel amplifier system, 200 MW or more of entry impedance and a noise level of 0.7 µVrms or less. The main component mean amplitude, conduction velocity and latency and the late component mean amplitude, conduction velocity and latency were respectively (mean ± SD): 26.5 ± 5.42 µV, 56.8 ± 5.42 m/s, 3.01 ± 0.31 ms, 0.12 ± 0.04 µV, 16.4 ± 2.95 m/s and 10.6 ± 2.48 ms. More sophisticated equipment has an internal noise of 0.6 µVrms. These data demonstrate that the technique can now be employed to study thin fiber neuropathies, like in leprosy, using commercial electromyographs, even in non-academic practices

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vasorelaxant effects of SR 47063 (4-(2-cyanimino-1,2-dihydropyrid-1-yl)-2,2-dimethyl-6-nitrochromene), a new K+-channel opener structurally related to levcromakalim, were examined in isolated human saphenous vein (HSV) and rat aorta (RA). HSV or RA rings were precontracted with either KCl or noradrenaline and cumulative relaxant concentration-response curves were obtained for SR 47063 (0.1 nM to 1 µM) in the presence or absence of 3 µM glibenclamide. SR 47063 potently relaxed HSV and RA precontracted with 20 mM (but not 60 mM) KCl or 10 µM noradrenaline in a concentration-dependent manner, showing slightly greater activity in the aorta. The potency of the effect of SR 47063 on HSV and RA was 12- and 58-fold greater, respectively, than that reported for the structurally related K+-channel opener levcromakalim. The vasorelaxant action of SR 47063 in both blood vessels was strongly inhibited by 3 µM glibenclamide, consistent with a mechanism of action involving ATP-dependent K+-channels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nephrolithiasis is one of the most common diseases in the Western world. The disease manifests itself with intensive pain, sporadic infections, and, sometimes, renal failure. The symptoms are due to the appearance of urinary stones (calculi) which are formed mainly by calcium salts. These calcium salts precipitate in the renal papillae and/or within the collecting ducts. Inherited forms of nephrolithiasis related to chromosome X (X-linked hypercalciuric nephrolithiasis or XLN) have been recently described. Hypercalciuria, nephrocalcinosis, and male predominance are the major characteristics of these diseases. The gene responsible for the XLN forms of kidney stones was cloned and characterized as a chloride channel called ClC-5. The ClC-5 chloride channel belongs to a superfamily of voltage-gated chloride channels, whose physiological roles are not completely understood. The objective of the present review is to identify recent advances in the molecular pathology of nephrolithiasis, with emphasis on XLN. We also try to establish a link between a chloride channel like ClC-5, hypercalciuria, failure in urine acidification and protein endocytosis, which could explain the symptoms exhibited by XLN patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ischemic pain occurs when there is insufficient blood flow for the metabolic needs of an organ. The pain of a heart attack is the prototypical example. Multiple compounds released from ischemic muscle likely contribute to this pain by acting on sensory neurons that innervate muscle. One such compound is lactic acid. Here, we show that ASIC3 (acid-sensing ion channel #3) has the appropriate expression pattern and physical properties to be the detector of this lactic acid. In rats, it is expressed only in sensory neurons and then only on a minority (~40%) of these. Nevertheless, it is expressed at extremely high levels on virtually all dorsal root ganglion sensory neurons that innervate the heart. It is extraordinarily sensitive to protons (Hill slope 4, half-activating pH 6.7), allowing it to readily respond to the small changes in extracellular pH (from 7.4 to 7.0) that occur during muscle ischemia. Moreover, both extracellular lactate and extracellular ATP increase the sensitivity of ASIC3 to protons. This final property makes ASIC3 a "coincidence detector" of three molecules that appear during ischemia, thereby allowing it to better detect acidosis caused by ischemia than other forms of systemic acidosis such as hypercapnia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is made in cooperation with Laboratory of Steel Structures and the steel company SSAB. Maximization of the benefits of high-strength steel usually requires the usage of thin wall thicknesses. This means the failures related to buckling, distortion and warping stand out. One must be aware of these phenomena to design thin-walled structures stressed with forces such as torsional loading. It is also important to take into account small stress ranges when evaluating the accurate fatigue strength of structures. The objective of this thesis is to clarify the theory of the uniform and non-uniform torsion. This paper focuses on warping due to the non-uniform torsion in double symmetric box girder and structural hollow section. The arisen stress states are explained and researched using the finite element method. Another research target is the distortion in double symmetric box girder due to torsion, and the restraining effect of transverse diaphragms at the load end. Multiple transverse diaphragms are used to study more efficient restraining against warping and distortion than a common one end plate structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have shown that myocardial dysfunction induced by food restriction is related to calcium handling. Although cardiac function is depressed in food-restricted animals, there is limited information about the molecular mechanisms that lead to this abnormality. The present study evaluated the effects of food restriction on calcium cycling, focusing on sarcoplasmic Ca2+-ATPase (SERCA2), phospholamban (PLB), and ryanodine channel (RYR2) mRNA expressions in rat myocardium. Male Wistar-Kyoto rats, 60 days old, were submitted to ad libitum feeding (control rats) or 50% diet restriction for 90 days. The levels of left ventricle SERCA2, PLB, and RYR2 were measured using semi-quantitative RT-PCR. Body and ventricular weights were reduced in 50% food-restricted animals. RYR2 mRNA was significantly decreased in the left ventricle of the food-restricted group (control = 5.92 ± 0.48 vs food-restricted group = 4.84 ± 0.33, P < 0.01). The levels of SERCA2 and PLB mRNA were similar between groups (control = 8.38 ± 0.44 vs food-restricted group = 7.96 ± 0.45, and control = 1.52 ± 0.06 vs food-restricted group = 1.53 ± 0.10, respectively). Down-regulation of RYR2 mRNA expressions suggests that chronic food restriction promotes abnormalities in sarcoplasmic reticulum Ca2+ release.