846 resultados para RESOLUÇÃO DE CONFLITOS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main goal of this bachelor work is the study of the physical properties of solids by thermal expansion coefficient measurements, which allows the exploration of various aspects of phase transitions. In this study, some theoretical aspects were focused, for example the first and second order phase transitions, Landau theory for phase transition and the volumetric thermal expansion coefficient. Furthermore, on the origin of the thermal expansion from the Lennard-Jones potential, that contains the anharmonic terms, which give rise to the phononic thermal expansion in solids

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method to determine Ca, K and Mg in a single aliquot of medicinal plants by HR-CS FAAS is proposed. The secondary lines for Ca (239.856 nm) and K (404.414 nm), and the alternate line measured at wing of the secondary line for Mg at (202.588 nm) allowed calibration within the 20 - 500 mg.L-1 Ca and K, and 1.0 - 80 mg.L-1 Mg. Twenty samples and three plant certified materials were analyzed. Results were in agreement at a 95% confidence level with reference values. Limits of detection were 2.4 mg.L-1 Ca, 1.9 mg.L-1 K and 0.3 mg.L-1 Mg. The RSD (n=12) were ≤ 5.1% and recoveries were between 83 and 108% for all analytes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes instrumental strategies for the determination of Mn in a wide range concentration by high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS F AAS) by means of different atomic lines (primary at 279.482 nm, secondary at 403.075 nm and alternative at 209.250 nm). These lines provided complementary concentration intervals, and large sample dilutions became unnecessary. The proposed method was applied to tap water, metal alloy certified material and foliar fertilizer. Accuracy for secondary line were evaluated by tests of significance (t Student test) with reference materials from the Institute of Technological Research of São Paulo, and the results were in agreement at the 95% confidence level. For primary and alternative lines, recovery is were in the 84-116% range and the RSD were 6.1% for all wavelengths. Analytical curves in the 0.1 - 2.0 mg L-1 (279.482 nm), 2.0 - 25 mg L-1 (403.075 nm), 25 - 500 mg L-1 (209.250 nm) intervals were obtained with linear correlation coefficient better than 0.9991. The detection limits were 3.3x10-3 mg L-1 (279.482 nm), 7.4 x 10-3 mg L-1 (403.075 nm), 3.9 mg L- 1 (209.250 nm). The found Mn concentrations were < 3.3x10-3 mg L-1 (tap water), 1.00 ± 0.04 (% m/m) (alloy IPT 25), 7235 ± 175 mg L-1 (foliar fertilizer 1), 4990 ± 132 mg L-1 (foliar fertilizer 2). A method was developed to detect interference of Fe in the Mn primary line (279.482 nm) using the ratio of absorbances of other lines of the triplet (279.827 nm and 280,108 nm).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enamel projection is often localized in furcation area between the roots of molars and is considered as predisposing factor for localized periodontal disease. When localized in anterior teeth, may determine anti-aesthetic condition as gingival recession. In this case, an enamel projection in tooth 23 produce an anti-aesthetic condition with was treated by mucogingival surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combination of several methods for solving aesthetics in a clinical case can be a complicating factor. The diagnosis and planning of the event held in conjunction with the dental technician expand the possibilities of success. The present case illustrates the aesthetic resolution through the association of implant- and tooth-supported prostheses using metal free ceramic systems. A 38-year old male patient presented with a complex smile. After diagnosis and treatment planning, two ceramic crowns were made, one on tooth 11 and one on the implant region 21, along with a laminated porcelain veneer on the region of 12. Aesthetic needs of the patient are predictable only with a sound diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sometimes we face clinical situations in which the lack of harmony in the smile is caused by a major exhibition of the gingival tissue. In these cases the professional should be able to perform a detailed analysis of the static and dynamic components of the smile, in search of a satisfactory planning and treatment which may include different dental specialties. For these situations, the association of periodontics/prosthesis is a viable alternative that has been used positively in search of an aesthetic and functional condition that benefits the patient, without leaving aside the preservation of periodontal tissues and of the remaining structure of the tooth. Thus, the aim of this study was to describe a case in which the association between these two areas was proposed to correct gummy smile and dental vestibularization. Clinical results and the satisfaction of the patient indicate that this multidisciplinary treatment combining periodontal and prosthetic techniques is favorable to positive results in cases of compromised smile aesthetics due to excessive gum tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The endodontic perforations are iatrogenic communications that result in a communication between the endodonto and periodontium. This occurrence represents about 10 % of cas- es of failure in endodontic treatment. The management may vary and is related to the drilling site endodontic. This paper aims to report a case of iatrogenic perforation and one of the possible alternatives for the treatment of endodontic perforations -level cervical tooth. During the opening coronary perforation occurred due to improper slope cervical penetration drill. Considering the drilling site, we opted for sealing com- posite resin after surgical access and absolute isolation. After sealing, the channel was filled with medication and instru- mented based on calcium hydroxide. Later the canal was obturated by lateral condensation technique with Sealapex. The radiographic follow-up showed regression of the lesion and the clinical silence confirmed the success of the treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is determined to analyse trigonometry problem solving with the help of CabriGéomètre II software from the perspective of two axes of mathematics teaching which are: the concept formation in Klausmeier and Goodwin´s perspective(1977) and problem solving according to Sternberg’s conception(2000). With such an approach traces of a more significant learning may be found , which according to Ausubel(1980) enables the adoption of better teaching and learning practices.