920 resultados para Monitoring of Structures


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presence and concentrations of radionuclides could be as a result of natural and human activities. This study examined the associations and differences among soil, sediment and water specific activities of long-lived radioactive element (LLRE). Gamma spectroscopy was used to measure the concentration of the LLRE along the Mini Okoro/Oginigba Creek, Port Harcourt. Specific activities of three selected LLRE were derived. Correlation analysis was carried out to examine associations among the specific activities across different substrates. A strong and a significant negative correlation exists between the specific activities of Water 40K and Soil 232Th (r =-0.721, p<0.05); Water 238U and Soil 238U (r = -0.717, p<0.05) and Water 40K and Sediment 238U (r=-0.69, p<0.05). Comparison using Mann-Whitney U test shows that, soil and sediment are similar in their specific activities with Z values of -0.408, -1.209 and -1.021 (p > 0.05) for 40K, 232Th and 238U respectively. The concentration of solid samples (soil and sediment) is different from the liquid (water) samples. These associations can be attributed to some specific underlying factors. And in other to understand them there is need for more studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As condições de ambiente térmico e aéreo, no interior de instalações para animais, alteram-se durante o dia, devido à influência do ambiente externo. Para que análises estatísticas e geoestatísticas sejam representativas, uma grande quantidade de pontos distribuídos espacialmente na área da instalação deve ser monitorada. Este trabalho propõe que a variação no tempo das variáveis ambientais de interesse para a produção animal, monitoradas no interior de instalações para animais, pode ser modelada com precisão a partir de registros discretos no tempo. O objetivo deste trabalho foi desenvolver um método numérico para corrigir as variações temporais dessas variáveis ambientais, transformando os dados para que tais observações independam do tempo gasto durante a aferição. O método proposto aproximou os valores registrados com retardos de tempo aos esperados no exato momento de interesse, caso os dados fossem medidos simultaneamente neste momento em todos os pontos distribuídos espacialmente. O modelo de correção numérica para variáveis ambientais foi validado para o parâmetro ambiental temperatura do ar, sendo que os valores corrigidos pelo método não diferiram pelo teste Tukey, a 5% de probabilidade dos valores reais registrados por meio de dataloggers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Part 14: Interoperability and Integration

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate well-documented diagnostic antigens, named B13, 1F8 and JL7 recombinant proteins, as potential markers of seroconversion in treated chagasic patients. Prospective study, involving 203 patients treated with benznidazole, was conducted from endemic areas of northern Argentina. Follow-up was possible in 107 out of them and blood samples were taken for serology and PCR assays before and 2, 3, 6, 12, 24 and 36 months after treatment initiation. Reactivity against Trypanosoma cruzi lysate and recombinant antigens was measured by ELISA. The rate of decrease of antibody titers showed nonlinear kinetics with an abrupt drop within the first three months after initiation of treatment for all studied antigens, followed by a plateau displaying a low decay until the end of follow-up. At this point, anti-B13, anti-1F8 and anti-JL7 titers were relatively close to the cut-off line, while anti-T. cruzi antibodies still remained positive. At baseline, 60.8% (45/74) of analysed patients tested positive for parasite DNA by PCR and during the follow-up period in 34 out of 45 positive samples (75.5%) could not be detected T. cruzi DNA. Our results suggest that these antigens might be useful as early markers for monitoring antiparasitic treatment in chronic Chagas disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, we describe the growth of NaCl crystals by evaporating droplets of aqueous solution while monitoring them with infrared thermography. Over the course of the evaporation experiments, variations in the recorded signal were observed and interpreted as being the result of evaporation and crystallisation. In particular, we observed sharp and transient decreases in the thermosignal during the later stages of high-concentration drop evaporation. The number of such events per experiment, referred to as “pop-cold events”, varied from 1 to over 100 and had durations from 1 to 15 s. These events are interpreted as a consequence from the top-supplied creeping (TSC) of the solution feeding the growth of efflorescence-like crystals. This phenomenon occurred when the solution was no longer macroscopically visible. In this case, efflorescence-like crystals with a spherulite shape grew around previously formed cubic crystals. Other crystal morphologies were also observed but were likely fed by mass diffusion or bottom-supplied creeping (BSC) and were not associated with “pop-cold events”; these morphologies included the cubic crystals at the centre, ring-shaped at the edge of droplets and fan-shaped crystals. After complete evaporation, an analysis of the numbers and sizes of the different types of crystals was performed using image processing. Clear differences in their sizes and distribution were observed in relation to the salt concentration. Infrared thermography permitted a level of quantification that previously was only possible using other techniques. As example, the intermittent efflorescence growth process was clearly observed and measured for the first time using infrared thermography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Invasive insects that successfully establish in introduced areas can significantly alter natural communities. These pests require specific establishment criteria (e.g. host suitability) that, when known, can help quantify potential damage to infested areas. Emerald ash borer (Agrilus planipennis [Coleoptera: Buprestidae]) is an invasive phloem-feeding pest which is responsible for the death of millions of ash trees (Fraxinus spp. L.). Over 200 surviving ash trees were previously identified in the Huron-Clinton Metroparks located in southeast Michigan. Trees were assessed over a four year period and a hierarchical cluster analysis was performed on dieback, vigor, and presence of signs and symptoms, in order to place trees into one of three tolerance groups. The clustering of trees with different responses to emerald ash borer attack suggests that there are different tolerance levels in North American ash trees in southeastern Michigan, and these groups were designated as apparently tolerant, not tolerant and intermediate tolerance. Adult landing rates and evidence of adult emergence were significantly lower in the apparently tolerant group compared with the not tolerant group, but larval survival from eggs placed on trees did not differ between tolerance groups. Therefore, it appears that apparently tolerant trees survive because they are less attractive to adult beetles which results in fewer eggs being laid on them. Trees in the apparently tolerant group remained of higher vigor over the four years of the study. North American ash may survive the emerald ash borer epidemic due to natural variation and inherent resistance regardless of the lack of co-evolutionary history with emerald ash borer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Routine monitoring of environmental pollution demands simplicity and speed without sacrificing sensitivity or accuracy. The development and application of sensitive, fast and easy to implement analytical methodologies for detecting emerging and traditional water and airborne contaminants in South Florida is presented. A novel method was developed for quantification of the herbicide glyphosate based on lyophilization followed by derivatization and simultaneous detection by fluorescence and mass spectrometry. Samples were analyzed from water canals that will hydrate estuarine wetlands of Biscayne National Park, detecting inputs of glyphosate from both aquatic usage and agricultural runoff from farms. A second study describes a set of fast, automated LC-MS/MS protocols for the analysis of dioctyl sulfosuccinate (DOSS) and 2-butoxyethanol, two components of Corexit®. Around 1.8 million gallons of those dispersant formulations were used in the response efforts for the Gulf of Mexico oil spill in 2010. The methods presented here allow the trace-level detection of these compounds in seawater, crude oil and commercial dispersants formulations. In addition, two methodologies were developed for the analysis of well-known pollutants, namely Polycyclic Aromatic Hydrocarbons (PAHs) and airborne particulate matter (APM). PAHs are ubiquitous environmental contaminants and some are potent carcinogens. Traditional GC-MS analysis is labor-intensive and consumes large amounts of toxic solvents. My study provides an alternative automated SPE-LC-APPI-MS/MS analysis with minimal sample preparation and a lower solvent consumption. The system can inject, extract, clean, separate and detect 28 PAHs and 15 families of alkylated PAHs in 28 minutes. The methodology was tested with environmental samples from Miami. Airborne Particulate Matter is a mixture of particles of chemical and biological origin. Assessment of its elemental composition is critical for the protection of sensitive ecosystems and public health. The APM collected from Port Everglades between 2005 and 2010 was analyzed by ICP-MS after acid digestion of filters. The most abundant elements were Fe and Al, followed by Cu, V and Zn. Enrichment factors show that hazardous elements (Cd, Pb, As, Co, Ni and Cr) are introduced by anthropogenic activities. Data suggest that the major sources of APM were an electricity plant, road dust, industrial emissions and marine vessels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We used 2012 sap flow measurements to assess the seasonal dynamics of daily plant transpiration (ETc) in a high-density olive orchard (Olea europaea L. cv. ‘Arbequina’) with a well-watered (HI) control treatment A to supply 100 % of the crop water needs, and a moderately (MI) watered treatment B that replaced 70% of crop needs. To assure that treatment A was well-watered, we compared field daily ETc values against ETc obtained with the Penman-Monteith (PM) combination equation incorporating the Orgaz et al. (2007) bulk daily canopy conductance (gc) model, validated for our non-limiting conditions. We then tested the hypothesis of indirectly monitoring olive ETc from readily available vegetation index (VI) and ground-based plant water stress indicator. In the process we used the FAO56 dual crop coefficient (Kc) approach. For the HI olive trees we defined Kcb as the basal transpiration coefficient, and we related Kcb to remotely sensed Soil Adjusted Vegetation Index (SAVI) through a Kcb-SAVI functional relationship. For the MI treatment, we defined the actual transpiration ETc as the product of Kcb and the stress reduction coefficient Ks obtained as the ratio of actual to crop ETc, and we correlated Ks with MI midday stem water potential (ψst) values through a Ks-ψ functional relationship. Operational monitoring of ETc was then implemented with the ETc = Kcb(SAVI)Ks(ψ)ETo relationship stemmed from the FAO56 approach and validated taking as inputs collected SAVI and ψst data reporting to year 2011. Low validation error (6%) and high goodness-of-fit of prediction were observed (R2 = 0.94, RSME = 0.2 mm day-1, P = 0.0015), allowing to consider that under field conditions it is possible to predict ETc values for our hedgerow olive orchards if SAVI and water potential (ψst) values are known.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Aims: Hepatocellular carcinoma (HCC) represents the second leading cause of cancer deaths worldwide. Protein induced by vitamin K absence (PIVKA-II) has been proposed as potential screening biomarker for HCC.This study has been designed to evaluate the role of PIVKA-II as diagnostic HCC marker, through the comparison between PIVKA-II and alpha-fetoprotein (AFP) serum levels on HCC patients and the two control groupsof patients with liver disease and without HCC. Methods: In an Italian prospective cohort, PIVKA-II levels were assessed on serum samplesby an automated chemiluminescent immunoassay (Abbott ARCHITECT). The study population included 65 patients with HCC (both “de novo” and recurrent), 111 with liver cirrhosis (LC) and 111 with chronic hepatitis C (CHC). Results: PIVKA-II levels were increased in patients with HCC (median 63.75, range: 12-2675 mAU/mL) compared to LC (median value: 30.95, range: 11.70–1251mAU / mL, Mann Whitney test p < 0.0001) and CHC (median value: 24.89, range: 12.98-67.68mAU / mL, p < 0.0001).The area under curve (AUC) for PIVKA-II was 0.817 (95% Confidence Interval(CI), 0.752-0.881). At the optimal threshold of 37 mAU / mL, identified by the Youden Index, the sensitivity and specificity were 79% and 76%, respectively. PIVKA-II was a better biomarker than AFP for the diagnosis of HCC, since the AUC for AFP was 0.670 (95% CI 0.585-0.754, p<0.0001) and at the best cutoff of 16.4 ng / mL AFP yielded 98% specificity but only 34% sensitivity. Conclusions:These initial data suggest the potential utility of this tool in the diagnosis of HCC.PIVKA-II alone or in combination may help to an early diagnosis of HCC and a significant optimization of patient management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis studies the state-of-the-art of phasor measurement units (PMUs) as well as their metrological requirements stated in the IEEE C37.118.1 and C37.118.2 Standards for guaranteeing correct measurement performances. Communication systems among PMUs and their possible applicability in the field of power quality (PQ) assessment are also investigated. This preliminary study is followed by an analysis of the working principle of real-time (RT) simulators and the importance of hardware-in-the-loop (HIL) implementation, examining the possible case studies specific for PMUs, including compliance tests which are one of the most important parts. The core of the thesis is focused on the implementation of a PMU model in the IEEE 5-bus network in Simulink and in the validation of the results using OPAL RT-4510 as a real-time simulator. An initial check allows one to get an idea about the goodness of the results in Simulink, comparing the PMU data with respect to the load-flow steady-state information. In this part, accuracy indices are also calculated for both voltage and current synchrophasors. The following part consists in the implementation of the same code in OPAL-RT 4510 simulator, after which an initial analysis is carried out in a qualitative way in order to get a sense of the goodness of the outcomes. Finally, the confirmation of the results is based on an examination of the attained voltage and current synchrophasors and accuracy indices coming from Simulink models and from OPAL system, using a Matlab script. This work also proposes suggestions for an upcoming operation of PMUs in a more complex system as the Digital Twin (DT) in order to improve the performances of the already-existing protection devices of the distribution system operator (DSO) for a future enhancement of power systems reliability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis, Ph.D candidate presents a compact sensor node (SN) designed for long-term and real-time acoustic emission (AE) monitoring of above ground storage tanks (ASTs). Each SN exploits up to three inexpensive low-frequency sensors based on piezoelectric diaphragms for effective leakage detection, and it is capable by means of built-in Digital Signal Processing functionalities to process the acquired time waveforms extracting the AE features usually required by testing protocols. Alternatively, capability to plug three high frequency AE sensors to a SN for corrosion simulated phenomena detection is envisaged and demonstrated. Another innovative aspect that the Ph.D candidate presents in this work is an alternative mathematical model of corrosion location on the bottom of the AST. This approach implies considering the three-dimensional localization model versus the two-dimensional commonly used according to the literature. This approach is aimed at significant optimization in the number of sensors in relation to the standard approach for solving localization problems as well as to allow filtering the false AE events related to the condensate droplets from AST ceiling. The technological implementation of this concept required the solution of a number of technical problems, such as the precise time of arrival (ToA) signal estimation, vertical localization of the AE source and multilaration solution that were discussed in detail in this work. To validate the developed prototype, several experimental campaigns were organized that included the simulation of target phenomena both in laboratory conditions and on a real water storage tank. The presented test results demonstrate the successful application of the developed AE system both for simulated leaks and for corrosion processes on the tank bottom. Mathematical and technological algorithms for localization and characterization of AE signals implemented during the development of the prototype are also confirmed by the test results.