929 resultados para Laboratory confirmation
Resumo:
β-lactamases are hydrolytic enzymes that inactivate the β-lactam ring of antibiotics such as penicillins and cephalosporins. The major diversity of studies carried out until now have mainly focused on the characterization of β-lactamases recovered among clinical isolates of Gram-positive staphylococci and Gram-negative enterobacteria, amongst others. However, only some studies refer to the detection and development of β-lactamases carriers in healthy humans, sick animals, or even in strains isolated from environmental stocks such as food, water, or soils. Considering this, we proposed a 10-week laboratory programme for the Biochemistry and Molecular Biology laboratory for majors in the health, environmental, and agronomical sciences. During those weeks, students would be dealing with some basic techniques such as DNA extraction, bacterial transformation, polymerase chain reaction (PCR), gel electrophoresis, and the use of several bioinformatics tools. These laboratory exercises would be conducted as a mini research project in which all the classes would be connected with the previous ones. This curriculum was compared in an experiment involving two groups of students from two different majors. The new curriculum, with classes linked together as a mini research project, was taught to a major in Pharmacy and an old curriculum was taught to students from environmental health. The results showed that students who were enrolled in the new curriculum obtained better results in the final exam than the students who were enrolled in the former curriculum. Likewise, these students were found to be more enthusiastic during the laboratory classes than those from the former curriculum.
Resumo:
A eritropoietina (EPO) é uma substância que estimula a produção de eritrócitos, aumentando a oxigenação muscular, sendo segregada de forma natural pelo organismo e excretada na urina em baixas concentrações. Devido às suas propriedades e características, a EPO foi rapidamente introduzida no mundo do desporto, como substância ilícita, proporcionando vantagens no rendimento desportivo. No início de 2000 foi desenvolvido um método de deteção direta de EPO Recombinante (rHuEPO) em urina humana por Lasne, baseado na focalização isoelétrica (IEF) em gel de poliacrilamida, seguido de duplo blote, tendo este sido publicado e validado. Em 2002, a Agência Mundial Antidopagem (AMA) implementou este mesmo método, sendo atualmente um dos métodos oficiais utilizado pelos laboratórios acreditados pela AMA. Desta forma, o ponto de partida para a realização deste trabalho consistiu na necessidade de implementar e validar o método de referência de IEF para a deteção de rHuEPO em urina humana. O trabalho foi realizado no Laboratório de Análises e Dopagem (LAD) do Instituto do Desporto de Portugal (IDP), atual Instituto Português do Desporto e Juventude (IPDJ). O principal objetivo deste trabalho consistiu no estudo/investigação de diferentes parâmetros de validação (especificidade/seletividade; capacidade de identificação; limite de deteção; exatidão e repetibilidade), de acordo com o protocolado no Procedimento Geral interno do Laboratório de Análises de Dopagem de Lisboa (LAD). O referido método de triagem e confirmação revelou possuir características de desempenho conformes com os requisitos aplicáveis, pelo que é considerado validado e apto.
Resumo:
The great majority of the courses on science and technology areas where lab work is a fundamental part of the apprenticeship was not until recently available to be taught at distance. This reality is changing with the dissemination of remote laboratories. Supported by resources based on new information and communication technologies, it is now possible to remotely control a wide variety of real laboratories. However, most of them are designed specifically to this purpose, are inflexible and only on its functionality they resemble the real ones. In this paper, an alternative remote lab infrastructure devoted to the study of electronics is presented. Its main characteristics are, from a teacher's perspective, reusability and simplicity of use, and from a students' point of view, an exact replication of the real lab, enabling them to complement or finish at home the work started at class. The remote laboratory is integrated in the Learning Management System in use at the school, and therefore, may be combined with other web experiments and e-learning strategies, while safeguarding security access issues.
Resumo:
RESUMO: Desde 1976 que as Forças Armadas desenvolvem acções de prevenção do consumo de drogas e álcool. Na década de 80 foi criada capacidade laboratorial e deu-se início a um programa de rastreios toxicológicos. No quinquénio 2001 a 2005, as proporções de resultados positivos, associando todos os tipos de rastreio, variaram entre 3,7% e 1,5%. De Outubro de 2006 a Julho de 2007 realizou-se um estudo analítico transversal, para estimar a prevalência do consumo de drogas (canabinóides, opiáceos, cocaína e anfetaminas) num dos Ramos das Forças Armadas, com base nos despistes realizados pelo seu laboratório. Foi utilizada uma amostra aleatória simples de 1039 militares, profissionais (QP) e contratados (RC), no activo e de ambos os sexos. Desde a nomeação dos militares a rastrear, passando pela cadeia de custódia das amostras até à obtenção do resultado foi utilizado apoio informático específico. O processo de pesquisa utilizou duas técnicas de triagem por imunoensaio e tecnologia de confirmação por GC/MS, de acordo com as recomendações europeias, permitindo estabelecer uma metodologia standard para organizações e empresas. A prevalência estimada, de consumidores de droga, foi de 3,8/1.000, para um erro de 0,37%. O número de casos registado (4) não permitiu a utilização de testes estatísticos que conduzissem à identificação de características determinantes da positividade, mas não deixou de revelar aspectos inesperados. A observação de séries de casos e a realização regular de estudos epidemiológicos, que ajudem a redefinir grupos alvo e a perceber a dimensão, as determinantes e as consequências do consumo de drogas é sugerida, em conclusão.--------------------------------------- RÉSUMÉ: Depuis 1976, les Forces Armées mettent au point des mesures visant à prévenir la consommation de drogues et d'alcool. En 1980, fut créé capacité laboratoriel et ont ensuite commencé un programme de dépistage toxicologique. Au cours des cinq années allant de 2001 à 2005, les proportions de consommateurs, impliquant tous les types de dépistage, allaient de 3,7% à 1,5 %. D'octobre 2006 à juillet 2007, une étude analytique transversale a été organisée pour évaluer la prévalence de l’usage de drogues (cannabis, opiacés, cocaïne et amphétamines) dans une branche de les Forces Armées, basée sur les dépistages faites par un laboratoire militaire, à l'aide d'un échantillon aléatoire de 1039 militaires, professionnels (QP) et sous contract (RC), à l’actif et des deux sexes. Tout au long du procès, de la nomination des donneurs, en passant par la chaine de garde des échantillons, jusqu’à obtention du résultat, il fut employé un appui informatique sécurisé. Le processus de recherche employa deux techniques de tri par imunoessay et la technologie de confirmation GC/MS, selon les recommandations européennes, permettant d'établir une méthodologie standard pour les organisations et les entreprises. La prévalence estimée fut de 3,8/1.000 pour une marge d’erreur de 0,37%. Le nombre de cas enregistrés (4) n'autorise pas l'utilisation de testes statistiques de menant à l'identification de caractéristiques déterminant de la positivité, mais il permet à révéler des aspects inattendus. L'observation de séries de cas et la tenue régulière d’études épidémiologiques, qui contribuent à redéfinir les groupes cibles et de comprendre l'ampleur, les déterminants et les conséquences de l'usage de drogues, est suggéré, en fin de compte.--------------------------------------- ABSTRACT: Since 1976, the Armed Forces, have been developing measures to prevent the use of drugs and alcohol. In 1980, was created laboratory facility which then started a program of toxicological screenings. In the five years running from 2001 to 2005, the proportions of consumers, involving all types of screening, ranged from 3,7% to 1,5%. From October 2006 to July 2007, a cross-sectional study was held to estimate the prevalence of drug use (cannabinoids, opiates, cocaine and amphetamines) in one branch of the Portuguese Armed Forces, based on laboratory screenings, using a random sample of 1039 military, professional (QP) and enlisted (RC), active-duty and of both sexes. Specific computer support was used all the way, from the appointment, including the chain of custody of samples, to the obtaining of the result. The process of search used two techniques for sorting by immunoassay and confirmation technology GC/MS, according to European recommendations, allowing to establish a standard methodology for organizations and companies. The estimated prevalence of drug users was 3.8/1.000 for a 0.37% error (95% confidence interval). The number of cases registered (4) does not permit use of statistical testing leading to the identification of characteristics weighing in the establishing to extrapolate for the population, but it allows revealing unexpected aspects. The observation of series of cases and the regular holding of epidemiological studies, which help redefine target groups and to understand the extent, the determinants and consequences of drug use, is suggested, in conclusion.
Resumo:
The recent changes on power systems paradigm requires the active participation of small and medium players in energy management. With an electricity price fluctuation these players must manage the consumption. Lowering costs and ensuring adequate user comfort levels. Demand response can improve the power system management and bring benefits for the small and medium players. The work presented in this paper, which is developed aiming the smart grid context, can also be used in the current power system paradigm. The proposed system is the combination of several fields of research, namely multi-agent systems and artificial neural networks. This system is physically implemented in our laboratories and it is used daily by researchers. The physical implementation gives the system an improvement in the proof of concept, distancing itself from the conventional systems. This paper presents a case study illustrating the simulation of real-time pricing in a laboratory.
Resumo:
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently been introduced in diagnostic microbiology laboratories for the identification of bacterial and yeast strains isolated from clinical samples. In the present study, we prospectively compared MALDI-TOF MS to the conventional phenotypic method for the identification of routine isolates. Colonies were analyzed by MALDI-TOF MS either by direct deposition on the target plate or after a formic acid-acetonitrile extraction step if no valid result was initially obtained. Among 1,371 isolates identified by conventional methods, 1,278 (93.2%) were putatively identified to the species level by MALDI-TOF MS and 73 (5.3%) were identified to the genus level, but no reliable identification was obtained for 20 (1.5%). Among the 1,278 isolates identified to the species level by MALDI-TOF MS, 63 (4.9%) discordant results were initially identified. Most discordant results (42/63) were due to systematic database-related taxonomical differences, 14 were explained by poor discrimination of the MALDI-TOF MS spectra obtained, and 7 were due to errors in the initial conventional identification. An extraction step was required to obtain a valid MALDI-TOF MS identification for 25.6% of the 1,278 valid isolates. In conclusion, our results show that MALDI-TOF MS is a fast and reliable technique which has the potential to replace conventional phenotypic identification for most bacterial strains routinely isolated in clinical microbiology laboratories.
Resumo:
OBJECTIVE: We examined the correlation between clinical wear rates of restorative materials and enamel (TRAC Research Foundation, Provo, USA) and the results of six laboratory test methods (ACTA, Alabama (generalized, localized), Ivoclar (vertical, volumetric), Munich, OHSU (abrasion, attrition), Zurich). METHODS: Individual clinical wear data were available from clinical trials that were conducted by TRAC Research Foundation (formerly CRA) together with general practitioners. For each of the n=28 materials (21 composite resins for intra-coronal restorations [20 direct and 1 indirect], 5 resin materials for crowns, 1 amalgam, enamel) a minimum of 30 restorations had been placed in posterior teeth, mainly molars. The recall intervals were up to 5 years with the majority of materials (n=27) being monitored, however, only for up to 2 years. For the laboratory data, the databases MEDLINE and IADR abstracts were searched for wear data on materials which were also clinically tested by TRAC Research Foundation. Only those data for which the same test parameters (e.g. number of cycles, loading force, type of antagonist) had been published were included in the study. A different quantity of data was available for each laboratory method: Ivoclar (n=22), Zurich (n=20), Alabama (n=17), OHSU and ACTA (n=12), Munich (n=7). The clinical results were summed up in an index and a linear mixed model was fitted to the log wear measurements including the following factors: material, time (0.5, 1, 2 and 3 years), tooth (premolar/molar) and gender (male/female) as fixed effects, and patient as random effect. Relative ranks were created for each material and method; the same was performed with the clinical results. RESULTS: The mean age of the subjects was 40 (±12) years. The materials had been mostly applied in molars (81%) and 95% of the intracoronal restorations were Class II restorations. The mean number of individual wear data per material was 25 (range 14-42). The mean coefficient of variation of clinical wear data was 53%. The only significant correlation was reached by OHSU (abrasion) with a Spearman r of 0.86 (p=0.001). Zurich, ACTA, Alabama generalized wear and Ivoclar (volume) had correlation coefficients between 0.3 and 0.4. For Zurich, Alabama generalized wear and Munich, the correlation coefficient improved if only composites for direct use were taken into consideration. The combination of different laboratory methods did not significantly improve the correlation. SIGNIFICANCE: The clinical wear of composite resins is mainly dependent on differences between patients and less on the differences between materials. Laboratory methods to test conventional resins for wear are therefore less important, especially since most of them do not reflect the clinical wear.
Resumo:
Furosemide (FD: Lasix) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-microliters sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6-14.0 mg), with a mean urine volume of 3024 ml (range 2620-3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analysis to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography-mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.
Resumo:
The purpose of this study was to estimate the energy cost of linear (EC) and vertical displacement (ECvert), mechanical efficiency and main stride parameters during simulated ski mountaineering at different speeds and gradients, to identify an optimal speed and gradient that maximizes performance. 12 subjects roller skied on a treadmill at three different inclines (10, 17 and 24 %) at three different speeds (approximately 70, 80 and 85 % of estimated peak heart rate). Energy expenditure was calculated by indirect calorimetry, while biomechanical parameters were measured with an inertial sensor-based system. At 10 % there was no significant change with speed in EC, ECvert and mechanical efficiency. At 17 and 24 % the fastest speed was significantly more economical. There was a significant effect of gradient on EC, ECvert and mechanical efficiency. The most economical gradient was the steepest one. There was a significant increase of stride frequency with speed. At steep gradients only, relative thrust phase duration decreased significantly, while stride length increased significantly with speed. There was a significant effect of gradient on stride length (decrease with steepness) and relative thrust phase duration (increase with steepness). A combination of a decreased relative thrust phase duration with increased stride length and frequency decreases ECvert. To minimize the energy expenditure to reach the top of a mountain and to optimize performance, ski-mountaineers should choose a steep gradient (~24 %) and, provided they possess sufficient metabolic scope, combine it with a fast speed (~6 km h(-1)).
Resumo:
COD discharges out of processes have increased in line with elevating brightness demands for mechanical pulp and papers. The share of lignin-like substances in COD discharges is on average 75%. In this thesis, a plant dynamic model was created and validated as a means to predict COD loading and discharges out of a mill. The assays were carried out in one paper mill integrate producing mechanical printing papers. The objective in the modeling of plant dynamics was to predict day averages of COD load and discharges out of mills. This means that online data, like 1) the level of large storage towers of pulp and white water 2) pulp dosages, 3) production rates and 4) internal white water flows and discharges were used to create transients into the balances of solids and white water, referred to as “plant dynamics”. A conversion coefficient was verified between TOC and COD. The conversion coefficient was used for predicting the flows from TOC to COD to the waste water treatment plant. The COD load was modeled with similar uncertainty as in reference TOC sampling. The water balance of waste water treatment was validated by the reference concentration of COD. The difference of COD predictions against references was within the same deviation of TOC-predictions. The modeled yield losses and retention values of TOC in pulping and bleaching processes and the modeled fixing of colloidal TOC to solids between the pulping plant and the aeration basin in the waste water treatment plant were similar to references presented in literature. The valid water balances of the waste water treatment plant and the reduction model of lignin-like substances produced a valid prediction of COD discharges out of the mill. A 30% increase in the release of lignin-like substances in the form of production problems was observed in pulping and bleaching processes. The same increase was observed in COD discharges out of waste water treatment. In the prediction of annual COD discharge, it was noticed that the reduction of lignin has a wide deviation from year to year and from one mill to another. This made it difficult to compare the parameters of COD discharges validated in plant dynamic simulation with another mill producing mechanical printing papers. However, a trend of moving from unbleached towards high-brightness TMP in COD discharges was valid.
Resumo:
[Acte. 1723-10-00]
Resumo:
[Acte. 1733-12-07. Paris]