888 resultados para Frequency Converter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: In contrast to conventional (CONV) neuromuscular electrical stimulation (NMES), the use of "wide-pulse, high-frequencies" (WPHF) can generate higher forces than expected by the direct activation of motor axons alone. We aimed at investigating the occurrence, magnitude, variability and underlying neuromuscular mechanisms of these "Extra Forces" (EF). METHODS: Electrically-evoked isometric plantar flexion force was recorded in 42 healthy subjects. Additionally, twitch potentiation, H-reflex and M-wave responses were assessed in 13 participants. CONV (25Hz, 0.05ms) and WPHF (100Hz, 1ms) NMES consisted of five stimulation trains (20s on-90s off). RESULTS: K-means clustering analysis disclosed a responder rate of almost 60%. Within this group of responders, force significantly increased from 4% to 16% of the maximal voluntary contraction force and H-reflexes were depressed after WPHF NMES. In contrast, non-responders showed neither EF nor H-reflex depression. Twitch potentiation and resting EMG data were similar between groups. Interestingly, a large inter- and intrasubject variability of EF was observed. CONCLUSION: The responder percentage was overestimated in previous studies. SIGNIFICANCE: This study proposes a novel methodological framework for unraveling the neurophysiological mechanisms involved in EF and provides further evidence for a central contribution to EF in responders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityö on tehty osana ETX-tutkimushanketta: 'Volyymiteholähteen suunnittelumetodien kehitys ja optimointi DFM-viitekehyksessä'. Työssä suunnitellaan hakkuriteholähteelle säätäjä. Tähän suunnittelun sektoriin syventyminen on teollisuudessa jäänyt monesti vähälle. Säätö on tavallisesti ajan puutteen ja apuvälineiden käytön osaamattomuuden tai puuttumisen takia suunniteltu kokeilemalla. Työssä muodostetaan jännitemuotoisesti säädetylle hakkurille piensignaalimallilla linearisoidut siirtofunktiot, joiden perusteella voidaan tarkastella hakkurin stabiilisuutta takaisinkytketyssä säätösilmukassa. Stabiiliustarkastelu tehdään taajuustasossa käyttäen Bode-kuvaajia. Näiden kuvaajien perusteella viritetään järjestelmään säätäjä. Säätäjän toimintaa aikatasossa tarkastellaan simuloimalla ja reaalisen laitteen toimimista laboratorioprototyypin avulla. Tulosten perusteella voidaan todeta, että jännitemuotoisella säädöllä flyback-hakkuri saadaan nopeaksi epäjatkuvalla käämivirralla. Mikäli halutaan hakkurin toimivan jatkuvalla käämivirralla, on syytä käyttää muita säätömenetelmiä, esimerkiksi huippuvirtasäätöä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several clinical studies have reported that EEG synchrony is affected by Alzheimer’s disease (AD). In this paper a frequency band analysis of AD EEG signals is presented, with the aim of improving the diagnosis of AD using EEG signals. In this paper, multiple synchrony measures are assessed through statistical tests (Mann–Whitney U test), including correlation, phase synchrony and Granger causality measures. Moreover, linear discriminant analysis (LDA) is conducted with those synchrony measures as features. For the data set at hand, the frequency range (5-6Hz) yields the best accuracy for diagnosing AD, which lies within the classical theta band (4-8Hz). The corresponding classification error is 4.88% for directed transfer function (DTF) Granger causality measure. Interestingly, results show that EEG of AD patients is more synchronous than in healthy subjects within the optimized range 5-6Hz, which is in sharp contrast with the loss of synchrony in AD EEG reported in many earlier studies. This new finding may provide new insights about the neurophysiology of AD. Additional testing on larger AD datasets is required to verify the effectiveness of the proposed approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Congenital hypogonadotropic hypogonadism (CHH) and split hand/foot malformation (SHFM) are two rare genetic conditions. Here we report a clinical entity comprising the two. METHODS: We identified patients with CHH and SHFM through international collaboration. Probands and available family members underwent phenotyping and screening for FGFR1 mutations. The impact of identified mutations was assessed by sequence- and structure-based predictions and/or functional assays. RESULTS: We identified eight probands with CHH with (n = 3; Kallmann syndrome) or without anosmia (n = 5) and SHFM, seven of whom (88%) harbor FGFR1 mutations. Of these seven, one individual is homozygous for p.V429E and six individuals are heterozygous for p.G348R, p.G485R, p.Q594*, p.E670A, p.V688L, or p.L712P. All mutations were predicted by in silico analysis to cause loss of function. Probands with FGFR1 mutations have severe gonadotropin-releasing hormone deficiency (absent puberty and/or cryptorchidism and/or micropenis). SHFM in both hands and feet was observed only in the patient with the homozygous p.V429E mutation; V429 maps to the fibroblast growth factor receptor substrate 2α binding domain of FGFR1, and functional studies of the p.V429E mutation demonstrated that it decreased recruitment and phosphorylation of fibroblast growth factor receptor substrate 2α to FGFR1, thereby resulting in reduced mitogen-activated protein kinase signaling. CONCLUSION: FGFR1 should be prioritized for genetic testing in patients with CHH and SHFM because the likelihood of a mutation increases from 10% in the general CHH population to 88% in these patients.Genet Med 17 8, 651-659.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We studied the incidence and prevalence of, and co-factors for depression in the Swiss HIV Cohort Study. METHODS: Depression-specific items were introduced in 2010 and prospectively collected at semiannual cohort visits. Clinical, laboratory and behavioral co-factors of incident depression among participants free of depression at the first two visits in 2010 or thereafter were analyzed with Poisson regression. Cumulative prevalence of depression at the last visit was analyzed with logistic regression. RESULTS: Among 4,422 participants without a history of psychiatric disorders or depression at baseline, 360 developed depression during 9,348 person-years (PY) of follow-up, resulting in an incidence rate of 3.9 per 100 PY (95% confidence interval (CI) 3.5-4.3). Cumulative prevalence of depression during follow-up was recorded for 1,937/6,756 (28.7%) participants. Incidence and cumulative prevalence were higher in injection drug users (IDU) and women. Older age, preserved work ability and higher physical activity were associated with less depression episodes. Mortality (0.96 per 100 PY, 95% CI 0.83-1.11) based upon 193 deaths over 20,102 PY was higher among male IDU (2.34, 1.78-3.09), female IDU (2.33, 1.59-3.39) and white heterosexual men (1.32, 0.94-1.84) compared to white heterosexual women and homosexual men (0.53, 0.29-0.95; and 0.71, 0.55-0.92). Compared to participants free of depression, mortality was slightly elevated among participants with a history of depression (1.17, 0.94-1.45 vs. 0.86, 0.71-1.03, P = 0.033). Suicides (n = 18) did not differ between HIV transmission groups (P = 0.50), but were more frequent among participants with a prior diagnosis of depression (0.18 per 100 PY, 95%CI 0.10-0.31; vs. 0.04, 0.02-0.10; P = 0.003). CONCLUSIONS: Depression is a frequent co-morbidity among HIV-infected persons, and thus an important focus of care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate how correlations between the diversity of the connectivity of networks and the dynamics at their nodes affect the macroscopic behavior. In particular, we study the synchronization transition of coupled stochastic phase oscillators that represent the node dynamics. Crucially in our work, the variability in the number of connections of the nodes is correlated with the width of the frequency distribution of the oscillators. By numerical simulations on Erdös-Rényi networks, where the frequencies of the oscillators are Gaussian distributed, we make the counterintuitive observation that an increase in the strength of the correlation is accompanied by an increase in the critical coupling strength for the onset of synchronization. We further observe that the critical coupling can solely depend on the average number of connections or even completely lose its dependence on the network connectivity. Only beyond this state, a weighted mean-field approximation breaks down. If noise is present, the correlations have to be stronger to yield similar observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional (CONV) neuromuscular electrical stimulation (NMES) (i.e., short pulse duration, low frequencies) induces a higher energetic response as compared to voluntary contractions (VOL). In contrast, wide-pulse, high-frequency (WPHF) NMES might elicit-at least in some subjects (i.e., responders)-a different motor unit recruitment compared to CONV that resembles the physiological muscle activation pattern of VOL. We therefore hypothesized that for these responder subjects, the metabolic demand of WPHF would be lower than CONV and comparable to VOL. 18 healthy subjects performed isometric plantar flexions at 10% of their maximal voluntary contraction force for CONV (25 Hz, 0.05 ms), WPHF (100 Hz, 1 ms) and VOL protocols. For each protocol, force time integral (FTI) was quantified and subjects were classified as responders and non-responders to WPHF based on k-means clustering analysis. Furthermore, a fatigue index based on FTI loss at the end of each protocol compared with the beginning of the protocol was calculated. Phosphocreatine depletion (ΔPCr) was assessed using 31P magnetic resonance spectroscopy. Responders developed four times higher FTI's during WPHF (99 ± 37 ×103 N.s) than non-responders (26 ± 12 ×103 N.s). For both responders and non-responders, CONV was metabolically more demanding than VOL when ΔPCr was expressed relative to the FTI. Only for the responder group, the ∆PCr/FTI ratio of WPHF (0.74 ± 0.19 M/N.s) was significantly lower compared to CONV (1.48 ± 0.46 M/N.s) but similar to VOL (0.65 ± 0.21 M/N.s). Moreover, the fatigue index was not different between WPHF (-16%) and CONV (-25%) for the responders. WPHF could therefore be considered as the less demanding NMES modality-at least in this subgroup of subjects-by possibly exhibiting a muscle activation pattern similar to VOL contractions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractThe present essay is aimed at getting the radiologist familiar with the basic histological skin structure, allowing for a better correlation with sonographic findings. A high-frequency (22 MHz) ultrasonography apparatus was utilized in the present study. The histological analysis was performed after the skin specimens fixation with formalin, inclusion in paraffin blocks and subsequent staining with hematoxylin-eosin. The authors present a literature review showing the relationship between sonographic and histological findings in normal cutaneous tissue, and discuss the technique for a better performance of the sonographic scan. High-frequency ultrasonography is an excellent tool for the diagnosis of different skin conditions. However, as this method is operator-dependent, it is crucial to understand the normal skin structure as well as the correlation between histological and sonographic findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work aims to analyze the possibilities of utilizing old crane driving AC induction motors in modern pulse-width-modulated variable frequency drives. Bearing currents and voltage stresses are the two main problems associated with modern IGBT inverters, and they may cause premature failure of an old induction motor. The origins of these two problems are studied. An analysis of the mechanism of bearing failure is proposed. Certain types of bearing currents are considered in detail. The most effective and economical means are chosen for bearing currents mitigation. Transient phenomena of cables and mechanism of over voltages occurring at motor terminals are studied in the work. The weakest places of the stator winding insulation system are shown and recommendations are given considering the mitigation of voltage stresses. Only the most appropriate and cost effective preventative methods are chosen for old motor drives. Rewinding of old motors is also considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flushing is an important maintenance task that removes accumulated particles in microirrigation laterals that can help to reduce clogging problems. The effect of three dripline flushing frequency treatments (no flushing, one flushing at the end of each irrigation period, and a monthly flushing during the irrigation period) was studied in surface and subsurface drip irrigation systems that operated using a wastewater treatment plant effluent for three irrigation periods of 540 h each. The irrigation systems had two different emitters, one pressure compensating and the other not, both molded and welded onto the interior dripline wall, placed in laterals 87 meters long. Dripline flow of the pressure compensating emitter increased 8% over time, while in the nonpressure compensating emitter, dripline flow increased 25% in the surface driplines and decreased 3% in the subsurface driplines by the emitter clogging. Emitter clogging was affected primarily by the interactions between emitter location, emitter type, and flushing frequency treatment. The number of completely clogged emitters was affected by the interaction between irrigation system and emitter type. There was an average of 3.7% less totally clogged emitters in flushed surface driplines with the pressurecompensating emitter as compared to flushed subsurface laterals with the nonpressure compensating emitter

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper industry has been experiencing remarkable structural changes since paper demand growth has ceased and some markets are declining. One reason behind the declined demand is the Internet, which has partially substituted the newspaper as a source of information. Paper products alone can no longer provide livelihood, and the paper industry has to find new business areas. In this research, we studied radio frequency identification (RFID), and the market opportunities it could provide for paper industry. The research combined a quantitative industry analysis and qualitative interviews. RFID is a growing industry in the beginning of its life cycle, in which value chains and technologies still evolve significantly. The industry is going to concentrate on the future, and in the long term RFID-identifiers will probably be printed on paper substrate or directly onto products. Paper industry has the chance to enter the RFID industry, but it has to obtain the required competences, for example through acquisitions. The business potential RFID offers to paper industry is inadequate, and while reviewing new strategic options, the paper industry must consider more options, for example the entire printed intelligence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the context of autonomous sensors powered by small-size photovoltaic (PV) panels, this work analyses how the efficiency of DC/DC-converter-based power processing circuits can be improved by an appropriate selection of the inductor current that transfers the energy from the PV panel to a storage unit. Each component of power losses (fixed, conduction and switching losses) involved in the DC/DC converter specifically depends on the average inductor current so that there is an optimal value of this current that causes minimal losses and, hence, maximum efficiency. Such an idea has been tested experimentally using two commercial DC/DC converters whose average inductor current is adjustable. Experimental results show that the efficiency can be improved up to 12% by selecting an optimal value of that current, which is around 300-350 mA for such DC/DC converters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This master’s thesis is focused on optimizing the parameters of a distribution transformer with respect to low voltage direct current (LVDC) distribution system. One of the main parts of low voltage direct current (LVDC) distribution system is transformer. It is studied from several viewpoints like filtering capabilities of harmonics caused by rectifier, losses and short circuit current limiting Determining available short circuit currents is one of the most important aspects of designing power distribution systems. Short circuits and their effects must be considered in selecting electrical equipment, circuit protection and other devices.