970 resultados para Dispositivos intra-uterinos de cobre
Resumo:
The electrochemical oxidation of glyphosate on an electrode of nickel and on one of copper was studied. With both electrodes electrochemical signals related to the glyphosate concentration were observed. However, the behaviour of the copper electrode was much better than that of the nickel electrode. A calibration curve was obtained of the electrical signal of this electrode as a function of the glyphosate concentration. The detection limit was 30 µM. In the case of nickel, an increase in the oxidation signal, which is related to the glyphosate concentration, was obtained. However, the results were less reproducible and additional information is necessary to propose an interaction mechanism between glyphosate and the electrode.
Resumo:
A simple and rapid conductometric method for captopril determination using copper(II) sulphate solution as titrant was developed. The method was based on the chemical reaction between captopril and Cu(II) ions yielding a precipitate. The conductance of the solution was monitored as a function of the added volume of titrant. The method was applied with success for captopril determination in three pharmaceutical formulations. The relative standard deviation for six successive measurements was smaller than 0.5%. Recovery values from three samples, ranging from 97.7 to 103%, were obtained.
Resumo:
It is investigated in the present contribution the oscillatory co-electrodeposition of CuSn on a polycrystalline gold surface in the presence of Triton X-100 surfactant and citric acid as additive, in acidic media. The experiments were conducted under potentiostatic control and the system dynamics characterized in terms of the morphology and stability of the current oscillations. Besides modulations in the frequency and amplitude of the current oscillations, several patterned states were observed, including relaxation-like and mixed mode oscillations. The oscillations were found to be very robust and some time series presented regular motions up to about two hours.
Resumo:
Mild steel blankets were covered with electrolytic copper thin layer, from cyanide bath, being evaluated the influence of the carbonate concentration in the physiochemical properties of those deposits. The cell voltage decreased as the current intensity decreased, but the adherence of the deposit was not enhanced, showing that the increment of carbonate concentration causes substantial problems. Chemical solubilization reactions of air-bearing carbon dioxide and oxidation of free cyanide ions through dissolved oxygen evolved in the anodic processes contribute to the copper plating to occur in an inefficient way. The best optimal conditions require a carbonate concentration below 50 g L-1.
Resumo:
Copper electrode can be used for determination of complexing compounds through complexation reactions between Cu(II) and the analites. In this work some studies with three compounds were performed: glycine (precursor of glyphosate synthesis), herbicide glyphosate and aminomethylphosphonic acid (main metabolite of glyphosate). These compounds are complexing agents for Cu electrodes. Through simple experiments (cyclic voltammetry and corrosion studies) the applicability of the copper electrode as electrochemical sensor for complexing compounds in flow systems was presented.
Resumo:
El desarrollo de este trabajo se basa en el análisis de los diferentes tipos de certificados digitales para la tecnología en la Nube y adicionalmente se realiza una recomendación para que se implemente en Ancert una herramienta comercial de firma electrónica.
Resumo:
High copper content is of great concern among producers of sugar-cane spirits who frequently use filters instead of cleaning the stills. This study compared the efficiency of activated carbon, ion-exchange-polymeric resin, and activated-carbon/iron-oxide magnetic composite for copper reduction without removing excessive organic compounds that are important for the beverage's quality. Resin was the most efficient copper adsorbent, removing fewer organic compounds. The composite also removed copper; however, it also removed large amounts of organic compounds. Activated carbon didn't remove sufficient copper to reduce its concentration to less than 5 g L-1, and it removed large amounts of higher alcohols and esters.
Resumo:
The present work purposes the preparation of a silica gel sorbent organically modified with 2-aminoethyl-3-aminobutylmethyldimethoxysilane (AAMDMS) and imprinted with Cu2+ ions by means surface imprinting technique and its use for selective on-line sorbent preconcentration of Cu2+ ions with further UV-VIS spectrophotometric determination by flow injection analysis. The Cu2+-imprinted silica gel, when compared with non imprinted silica gel and silica gel, showed from the binary mixture of Cu2+/Ni2+ relative selectivity coefficient (k') of 6.84 and 5.43 and 6.64 and 19.83 for the mixture Cu2+/Pb2+, thus demonstrating higher selectivity of Cu2+-imprinted silica gel towards Cu2+ ions. Under optimized condition, the on-line preconcentration method provided detection limit of 3.4 μg L-1 and linear range ranging from 30.0 up to 300.0 μg L-1 (r = 0.995). The accuracy of method was successfully assessed by analyzing different kind of spiked water samples with recovery values ranging from 92.2 up to 103.0%.
Resumo:
Copper toxicity in soil was evaluated using biomarkers of oxidative stress (catalase enzyme activity, superoxide dismutase and lipid peroxidation) in the earthworm Eisenia foetida. Agricultural topsoils from mining areas of the Aconcagua river basin were collected. Total copper concentrations were in the range of 94-959 mg kg-1, while the exchangeable copper concentrations were in the range of 46-2225 µg kg-1. Earthworms exposed to soil with exchangeable copper concentrations above 32 µg kg-1 showed an increase in catalase activity. Parameters of antioxidant activity were more sensitive than the weight change and thus can be used as appropriate biomarkers in Eisenia foetida.
Resumo:
In this work a sulfide quantification protocol using voltammetric methods was developed to evaluate the effect of dissolved sulfides on copper complexation. On the basis of pH, sulfide release from the dissociation of specific metal sulfide complexes can be electrochemically measured and then removed (as H2S) by a N2 purge. Cathodic stripping square wave voltammetry (CSSWV) was conducted to quantify Cu sulfides complexes which dissociate at pH < 5.0 during the process of acid titration.
Resumo:
An UV-Ozone reactor was developed with an ignition tube extracted into HID mercury lamp used to irradiation on zinc oxide (ZnO) and fluorinated tin oxide (FTO) films for PLEDs devices. Different exposures times were used. In contact angle measurements revealed better results for ZnO and FTO by 15 and 5 min, respectively. In Diffuse Reflectance Infra-red Fourier Transformed (DRIFT) spectroscopy allowed the observation of water, hydrocarbon and carbon dioxide adsorbed on the untreated TCO surfaces. After the UV-Ozone treatment the contaminants were significantly reduced or eliminated and the PLEDs devices decreased threshold voltages in comparison with respectively untreated TCOs.
Resumo:
The objective of this study was to evaluate the toxic effect of Cu2 + in the physiological development of E. gracilis. The results showed that E. gracilis had an effect on the dose-dependent growth to the concentration of metal. The exposure of E. gracilis metal at doses of 0.8 and 1.6 mM of Cu2+ showed a significant negative effect on the stability of DNA and photosynthetic pigments involved in capturing light in the antenna complex after 144 h of exposure to the metal.
Resumo:
This work describes methodologies for speciation analysis of the metals copper and zinc as total, total dissolved, labile, as well as complexation capacity (conditional stability constants and available ligand concentration), using the same technique, differential pulse anodic stripping voltammetry (DPASV). Several supporting electrolytes were tested, and the results showed that KNO3 and HNO3 resulted in voltamograms without interferences as well as excellent resolution for the total and labile fractions. The methodology using the DPASV technique allows a simple and low cost analysis of copper and zinc speciation, with high precision and sensitivity, with limits of quantification (LOQ) of 1.8 nmol L-1 for copper and 2.1 nmol L-1 for zinc.
Resumo:
This work aimed to access the contents and chemical forms and to estimate mobility and availability of cooper and zinc in samples from two soils (Haplortox and Paleudult) previously treated with doses of sewage sludge (SS) and municipal solid waste compost (MSWC), besides a control treatment. Largest percentages of Cu and Zn were determined in the organic matter fraction. Zn showed higher percentages of soluble and exchangeable fractions than Cu. Treatments with SS showed higher potential of Cu and Zn availability. Modifications in soil attributes due to residue application affected metal mobility and availability indexes.
Resumo:
Copper fractionation in plasma, muscle and liver of Nile tilapia was performed after protein separation by 2D-PAGE. SR XRF analysis indicated the presence of copper in three protein spots of plasma, and in two protein spots of muscle and liver, respectively. Copper ions were found to be distributed mostly in proteins that had a molar mass of less than 54 kDa and greater than 13 kDa and a pI in the 5.3-9.3 range. The copper concentration bound to these proteins was determined by GFAAS which showed concentrations in the 1.20-4.82 mg g-1 range.