970 resultados para Command
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A robust 12 kW rectifier with low THD in the line currents, based on an 18-pulse transformer arrangement with reduced kVA capacities followed by a high-frequency isolation stage is presented in this work. Three full-bridge (buck-based) converters are used to allow galvanic isolation and to balance the dc-link currents, without current sensing or current controller. The topology provides a regulated dc output with a very simple and well-known control strategy and natural three-phase power factor correction. The phase-shift PWM technique, with zero-voltage switching is used for the high-frequency dc-dc stage. Analytical results from Fourier analysis of winding currents and the vector diagram of winding voltages are presented. Experimental results from a 12 kW prototype are shown in the paper to verify the efficiency, robustness and simplicity of the command circuitry to the proposed concept.
Resumo:
Backgrounds and Objectives: Both continuous venous anesthesia with propofol and inhalational anesthesia with sevoflurane propitiate fast arousal with few side effects. The aim of this study was to compare the arousal and post anesthestic recovery times in patients submitted to these two agents. Methods: Forty three patient aged 18 to 50 years, physical status I or II, submitted to gynecological laparoscopy were distributed in two groups: G1 - propofol in continuous infusion of 115 μg.kg -1.min -1 and G2 sevoflurane. All the patients were pre-medicated with 7.5 mg midazolam, sufentanil 0.5 μg.kg -1, propofol 2 mg.kg -1, atracurium 0.5 mg.kg -1, N 2O in 50% of oxygen in a no-rebreathing system. The depth of the anesthesia and arousal time were assessed by the Bispectral index (BIS). The time between end of anesthesia and eye opening, time for command response and time for orientation were also evaluated. Results: The times recorded in minutes were: G1 - eye opening 8.2 ± 2.9, command response 8.6 ± 3.1, orientation 9.8 ± 3.4, recovery 31.6 ± 3.8; G2 - eye opening 4.5 ± 3, command response 4.9 ± 3.4, orientation 6.2 ± 3.4, recovery 66 ± 8. Except the recovery time, all the values were larger in G1. Conclusions: Both intravenous propofol or inhalational sevoflurane were considered excellent anesthetic techniques as to recovery time and recovery room discharge. Sevoflurane provided an earlier arousal with a longer recovery room stay as compared to propofol.
Resumo:
Severe disabled children have little chance of environmental and social exploration and discovery, and due this lack of interaction and independency, it may lead to an idea that they are unable to do anything by themselves. This idea is called learned helplessness and is very negative for the child cognitive development and social development as well. With this entire situation it is very likely that the self-steam and mood of this child. Trying to help these children on this situation, educational robotics can offer and aid, once it can give them a certain degree of independency in exploration of environment. The system developed in this work allows the child to transmit the commands to a robot. Sensors placed on the child's body can obtain information from head movement or muscle pulses to command the robot to carry the tasks. Also, this system can be used with a variety of robots, being necessary just a previous configuration. It is expected that, with the usage of this system, the disabled children have a better cognitive development and social interaction, balancing in a certain way, the negative effects of their disabilities. © 2011 IEEE.
Resumo:
Includes bibliography
Resumo:
The implementation of vibration analysis techniques based on virtual instrumentation has spread increasingly in the academic and industrial branch, since the use of any software for this type of analysis brings good results at low cost. Among the existing software for programming and creation of virtual instruments, the LabVIEW was chosen for this project. This software has good interface with the method of graphical programming. In this project, it was developed a system of rotating machine condition monitoring. This monitoring system is applied in a test stand, simulating large scale applications, such as in hydroelectric, nuclear and oil exploration companies. It was initially used a test stand, where an instrumentation for data acquisition was inserted, composed of accelerometers and inductive proximity sensors. The data collection system was structured on the basis of an NI 6008 A/D converter of National Instruments. An electronic circuit command was developed through the A/D converter for a remote firing of the test stand. The equipment monitoring is performed through the data collected from the sensors. The vibration signals collected by accelerometers are processed in the time domain and frequency. Also, proximity probes were used for the axis orbit evaluation and an inductive sensor for the rotation and trigger measurement. © (2013) Trans Tech Publications, Switzerland.
Resumo:
Pós-graduação em Ciências Sociais - FFC
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Direito - FCHS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Educação - FFC
Resumo:
Includes bibliography
Resumo:
Includes bibliography