937 resultados para Chip


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The emission intensity of fluorophore molecule may change in presence of strong plasmon field induced by nanoparticles. The enhancement intensity is optimized through selective clustering or functionalization of nanoparticles in closed vicinity of fluorophore. Our study is aimed at understanding the enhancement mechanism of fluorescence intensity in presence of gold nanoparticles to utilize it in molecular sensing and in situ imaging in the microfluidic lab-on-chip device. Related phenomena are studied in situ in a microfluidic channel via fluorescence imaging. Detailed analysis is carried out to understand the possible mechanism of enhancement of fluorescence due to nanoparticles. In the present experimental study we show that SYTO9 fluorescence intensity increased in presence of Au nanoparticles of similar to 20 nm diameter. The fluorescence intensity is 20 time more compared to that in absence of Au nanoparticles. The enhancement of fluorescence intensity is attributed to the plasmonic resonance of Au nanoparticle at around the fluorescence emission wavelength. Underlying fundamental mechanism via dipole interaction model is explored for quantitative correlation of plasmonic enhancement properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fiber-reinforced plastics (FRPs) are typically difficult to machine due to their highly heterogeneous and anisotropic nature and the presence of two phases (fiber and matrix) with vastly different strengths and stiffnesses. Typical machining damage mechanisms in FRPs include series of brittle fractures (especially for thermosets) due to shearing and cracking of matrix material, fiber pull-outs, burring, fuzzing, fiber-matrix debonding, etc. With the aim of understanding the influence of the pronounced heterogeneity and anisotropy observed in FRPs, ``Idealized'' Carbon FRP (I-CFRP) plates were prepared using epoxy resin with embedded equispaced tows of carbon fibers. Orthogonal cutting of these I-CFRPs was carried out, and the chip formation characteristics, cutting force signals and strain distributions obtained during machining were analyzed using the Digital Image Correlation (DIC) technique. In addition, the same procedure was repeated on Uni-Directional CFRPs (UD-CFRPs). Chip formation mechanisms in FRPs were found to depend on the depth of cut and fiber orientation with pure epoxy showing a pronounced ``size effect.'' Experimental results indicate that in-situ full field strain measurements from DIC coupled with force measurements using dynamometry provide an adequate measure of anisotropy and heterogeneity during orthogonal cutting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we have demonstrated three unique regimes in the evaporation lifecycle of a pair of sessile droplets placed in variable proximity on a hydrophobic substrate. For small separation distance, the droplets undergo asymmetric spatiotemporal,evaporation leading to contact angle hysteresis and suppressed vaporization. The reduced evaporation has been attributed quantitatively to the existence of a constrained vapor-rich dome between the two droplets. However, a dynamic decrease in the droplet radius due to solvent removal marks a return to symmetry in terms of evaporation and contact angle. We have described the variation in evaporation flux using a universal correction factor. We have also demonstrated the existence of a critical separation distance beyond which the droplets in the, droplet pair do not affect each other. The results are crucial to a plethora of applications ranging from surface patterning to lab-on-a-chip devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we have demonstrated three unique regimes in the evaporation lifecycle of a pair of sessile droplets placed in variable proximity on a hydrophobic substrate. For small separation distance, the droplets undergo asymmetric spatiotemporal,evaporation leading to contact angle hysteresis and suppressed vaporization. The reduced evaporation has been attributed quantitatively to the existence of a constrained vapor-rich dome between the two droplets. However, a dynamic decrease in the droplet radius due to solvent removal marks a return to symmetry in terms of evaporation and contact angle. We have described the variation in evaporation flux using a universal correction factor. We have also demonstrated the existence of a critical separation distance beyond which the droplets in the, droplet pair do not affect each other. The results are crucial to a plethora of applications ranging from surface patterning to lab-on-a-chip devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SU8-based micromechanical structures are widely used as thermal actuators in the development of compliant micromanipulation tools. This paper reports the design, nonlinear thermomechanical analysis, fabrication, and thermal actuation of SU8 actuators. The thermomechanical analysis of the actuator incorporates nonlinear temperature-dependent properties of SU8 polymer to accurately model its thermal response during actuation. The designed SU8 thermal actuators are fabricated using surface micromachining techniques and the electrical interconnects are made to them using flip-chip bonding. The issues due to thermal stress during fabrication are discussed and a novel strategy is proposed to release the thermal stress in the fabricated actuators. Subsequent characterization of the actuator using an optical profilometer reveals excellent thermal response, good repeatability, and low hysteresis. The average deflection is similar to 8.5 mu m for an actuation current of similar to 5 mA. The experimentally obtained deflection profile and the tip deflection at different currents are both shown to be in good agreement with the predictions of the nonlinear thermomechanical model. This underscores the need to consider nonlinearities when modeling the response of SU8 thermal actuators. 2015-0087]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An immunosensor based on imaging ellipsometry and its potential applications was demonstrated in this paper. It has been proven a fast, reliable, and convenient method to quantify the thickness distribution of protein layers or detect protein concentration in solution. Combined with a protein chip, the immunosensor was able to detect multiple analytes simultaneously without any labeling. Preliminary results demonstrated how this immunosensor could be used to monitor several independent biospecific binding processes in real-time and in situ conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The feasibility of using protein A to immobilize antibody on silicon surface for a biosensor with imaging ellipsometry was presented in this study. The amount of human IgG bound with anti-IgG immobilized by the protein A on silicon surface was much more than that bound with anti-IgG immobilized by physical adsorption. The result indicated that the protein A could be used to immobilize antibody molecules in a highly oriented manner and maintain antibody molecular functional configuration on the silicon surface. High reproducibility of the amount of antibody immobilization and homogenous antibody adsorption layer on surfaces could be obtained by this immobilization method. Imaging ellipsometry has been proven to be a fast and reliable detection method and sensitive enough to detect small changes in a molecular monolayer level. The combination of imaging ellipsometry and surface modification with protein A has the potential to be further developed into an efficient immunoassay protein chip.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A multi-disciplinary team based at Heriot-Watt University and other Universities has been set up to tackle the design and manufacturing of lab-on-a-chip for industries as one of the demonstrators of the EPSRC Grand Challenge project "3D-Mintegration". The team focuses on the analysis of foetal genetic material extracted from maternal blood as a smart alternative to invasive prenatal testing such as amniocentesis. The first module of the microsystem envisaged achieves a separation of blood cells from plasma. This system permits the testing of different manufacturing techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a new generation of integrated solid-state gas-sensors embedded in SOI micro-hotplates. The micro-hotplates lie on a SOI membrane and consist of MOSFET heaters that elevate the operating temperature, through self-heating, of a gas sensitive material. These sensors are fully compatible with SOI CMOS or BiCMOS technologies, offer ultra-low power consumption (under 100 mW), high sensitivity, low noise, low unit cost, reproducibility and reliability through the use of on-chip integration. In addition, the new integrated sensors offer a nearly uniform temperature distribution over the active area at its operating temperatures at up to about 300-350°C. This makes SOI-based gas-sensing devices particularly attractive for use in handheld battery-operated gas monitors. This paper reports on the design of a chemo-resistive gas sensor and proposes for the first time an intelligent SOI membrane microcalorimeter using active micro-FET heaters and temperature sensors. A comprehensive set of numerical and analogue simulations is also presented including complex 2D and 3D electro-thermal numerical analyses. © 2001 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this communication, we describe a new method which has enabled the first patterning of human neurons (derived from the human teratocarcinoma cell line (hNT)) on parylene-C/silicon dioxide substrates. We reveal the details of the nanofabrication processes, cell differentiation and culturing protocols necessary to successfully pattern hNT neurons which are each key aspects of this new method. The benefits in patterning human neurons on silicon chip using an accessible cell line and robust patterning technology are of widespread value. Thus, using a combined technology such as this will facilitate the detailed study of the pathological human brain at both the single cell and network level. © 2010 Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The performance of a series of near-UV (∼385 nm) emitting LEDs, consisting of high efficiency InGaN/AlInGaN QWs in the active region, was investigated. Significantly reduced roll-over of efficiency at high current density was found compared to InGaN/GaN LEDs emitting at a similar wavelength. The importance of optical cavity effects in flip-chip geometry devices has also been investigated. The light output was enhanced by more than a factor of 2 when the lightemitting region was located at an anti-node position with respect to a high reflectivity current injection mirror. A power of 0.49 mW into a numerical aperture of 0.5 was obtained for a junction area of 50μm in diameter and a current of 30 mA, corresponding to a radiance of 30 W/cm2/str.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new form of ultrafast bistable polarization switching in twin-stripe injection lasers has been observed. For the first time, triggering between bistable states has been achieved by injecting light from a neighboring laser integrated on the same chip. Ultrafast switching times of 250 ps have been measured (detector limited).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Capacitive parasitic feedthrough is an impediment that is inherent to all electrically interfaced micron scale resonant devices, resulting in increased challenges to their integration in more complex circuits, particularly as devices are scaled to operate at higher frequencies for RF applications. In this paper, a technique to cancel the undesirable effects of capacitive feedthrough that was previously proposed is here developed for an on-chip implementation. The method reported in this paper benefits from the simplicity of its implementation, and its effectiveness is demonstrated in this paper. This technique is demonstrated for two disk-plate resonators that have been excited in the wine glass mode at 5.4 MHz, though applicable to almost any electrically interfaced resonator. Measurements of the electrical transmission from these resonators show that the magnitude of the frequency response of the system is enhanced by up to 19 dB, while the phase is found to shift through a full 180° about the resonant frequency. This method is proposed as a useful addition to other techniques for enhancing the measured response of electrostatic micromechanical resonators. © 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is estimated that the adult human brain contains 100 billion neurons with 5-10 times as many astrocytes. Although it has been generally considered that the astrocyte is a simple supportive cell to the neuron, recent research has revealed new functionality of the astrocyte in the form of information transfer to neurons of the brain. In our previous work we developed a protocol to pattern the hNT neuron (derived from the human teratocarcinoma cell line (hNT)) on parylene-C/SiO(2) substrates. In this work, we report how we have managed to pattern hNT astrocytes, on parylene-C/SiO(2) substrates to single cell resolution. This article disseminates the nanofabrication and cell culturing steps necessary for the patterning of such cells. In addition, it reports the necessary strip lengths and strip width dimensions of parylene-C that encourage high degrees of cellular coverage and single cell isolation for this cell type. The significance in patterning the hNT astrocyte on silicon chip is that it will help enable single cell and network studies into the undiscovered functionality of this interesting cell, thus, contributing to closer pathological studies of the human brain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The fluid flow associated with micro and meso scale devices is currently of interest. Experiments were performed to study the fluid flow in meso-scale channels. A straight flow tube was fabricated with 1.0x4.0mm^2 in rectangular cross section and 200mm in length, which was made of quartz for flow visualization and PIV measurements. Reynolds numbers were ranged from 311 to over 3105. The corresponding pressure drop was from 0.65KPa to over 16.58KPa between the inlet and outlet of the tube. The micro PIV was developed to measure the velocity distribution in the tube. A set of microscope object lens was mounted ahead of CCD camera to obtain optimized optical magnification on the CCD chip. The velocity distributions near the outlet of the tube were measured to obtain full-developed flow. A CW laser beam was focused directly on the test section by a cylinder lens to form a small light sheet. Thus, high power density of light was formed on the view region. It is very important to the experiment while the velocity of the flow reaches to a few meters per second within millimeter scale. In this case, it is necessary to reduce exposure time to microseconds for PIV measurements. In the present paper, the experimental results are compared with the classical theories.