953 resultados para white-beam synchrotron radiation topography


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a new Ultra Wide Band (UWB) Timed- Array Transmitter System with Beamforming capability for high-resolution remote acquisition of vital signals. The system consists of four identical channels, where each is formed of a serial topology with three modules: programmable delay circuit (PDC or τ), a novel UWB 5th Gaussian Derivative order pulse generator circuit (PG), and a planar Vivaldi antenna. The circuit was designed using 0.18μm CMOS standard process and the planar antenna array was designed with filmconductor on Rogers RO3206 substrate. Spice simulations results showed the pulse generation with 104 mVpp amplitude and 500 ps width. The power consumption is 543 μW, and energy consumption 0.27 pJ per pulse using a 2V power supply at a pulse repetition rate (PRR) of 100 MHz. Electromagnetic simulations results, using CST Microwave (MW) Studio 2011, showed the main lobe radiation with a gain maximum of 13.2 dB, 35.5º x 36.7º angular width, and a beam steering between 17º and -11º for azimuthal (θ) angles and 17º and -18º for elevation (φ) angles at the center frequency of 6 GHz

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main problem connected to cone beam computed tomography (CT) systems for industrial applications employing 450 kV X-ray tubes is the high amount of scattered radiation which is added to the primary radiation (signal). This stray radiation leads to a significant degradation of the image quality. A better understanding of the scattering and methods to reduce its effects are therefore necessary to improve the image quality. Several studies have been carried out in the medical field at lower energies, whereas studies in industrial CT, especially for energies up to 450 kV, are lacking. Moreover, the studies reported in literature do not consider the scattered radiation generated by the CT system structure and the walls of the X-ray room (environmental scatter). In order to investigate the scattering on CT projections a GEANT4-based Monte Carlo (MC) model was developed. The model, which has been validated against experimental data, has enabled the calculation of the scattering including the environmental scatter, the optimization of an anti-scatter grid suitable for the CT system, and the optimization of the hardware components of the CT system. The investigation of multiple scattering in the CT projections showed that its contribution is 2.3 times the one of primary radiation for certain objects. The results of the environmental scatter showed that it is the major component of the scattering for aluminum box objects of front size 70 x 70 mm2 and that it strongly depends on the thickness of the object and therefore on the projection. For that reason, its correction is one of the key factors for achieving high quality images. The anti-scatter grid optimized by means of the developed MC model was found to reduce the scatter-toprimary ratio in the reconstructed images by 20 %. The object and environmental scatter calculated by means of the simulation were used to improve the scatter correction algorithm which could be patented by Empa. The results showed that the cupping effect in the corrected image is strongly reduced. The developed CT simulation is a powerful tool to optimize the design of the CT system and to evaluate the contribution of the scattered radiation to the image. Besides, it has offered a basis for a new scatter correction approach by which it has been possible to achieve images with the same spatial resolution as state-of-the-art well collimated fan-beam CT with a gain in the reconstruction time of a factor 10. This result has a high economic impact in non-destructive testing and evaluation, and reverse engineering.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Time-of-flight photoemission spectromicroscopy was used to measure and compare the two-photon photoemission (2PPE) spectra of Cu and Ag nanoparticles with linear dimensions ranging between 40 nm and several 100 nm, with those of the corresponding homogeneous surfaces. 2PPE was induced employing femtosecond laser radiation from a frequency-doubled Ti:sapphire laser in the spectral range between 375 nm and 425 nm with a pulse width of 200 fs and a repetition rate of 80 MHz. The use of a pulsed radiation source allowed us to use a high-resolution photoemission electron microscope as imaging time-of-flight spectrometer, and thus to obtain spectroscopic information about the laterally resolved electron signal. Ag nanoparticle films have been deposited on Si(111) by electron-beam evaporation, a technique leading to hemispherically-shaped Ag clusters. Isolated Cu nanoparticles have been generated by prolonged heating of a polycrystalline Cu sample. If compared to the spectra of the corresponding homogeneous surfaces, the Cu and Ag nanoparticle spectra are characterized by a strongly enhanced total 2PPE yield (enhancement factor up to 70), by a shift (about 0.1 eV) of the Fermi level onset towards lower final state energies, by a reduction of the work function (typically by 0.2 eV) and by a much steeper increase of the 2PPE yield towards lower final state energies. The shift of the Fermi level onset in the nanoparticle spectra has been explained by a positive unit charge (localized photohole) residing on the particle during the time-scale relevant for the 2PPE process (few femtoseconds). The total 2PPE yield enhancement and the different overall shape of the spectra have been explained by considering that the laser frequency was close to the localized surface plasmon resonance of the Cu and Ag nanoparticles. The synchronous oscillations induced by the laser in the metal electrons enhance the near-zone (NZ) field, defined as the linear superposition of the laser field and the field produced in the vicinity of the particles by the forced charge oscillations. From the present measurements it is clear that the NZ field behavior is responsible for the 2PPE enhancement and affects the 2PPE spatial and energy distribution and its dynamics. In particular, its strong spatial dependence allows indirect transitions through real intermediate states to take place in the metal clusters. Such transitions are forbidden by momentum conservation arguments and are thus experimentally much less probable on homogeneous surfaces. Further, we investigated specially tailored moon-shaped small metal nanostructures, whose NZ field was theoretically predicted, and compared the calculation with the laterally resolved 2PPE signal. We could show that the 2PPE signal gives a clear fingerprint of the theoretically predicted spatial dependence of the NZ field. This potential of our method is highly attractive in the novel field of plasmonics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Zur geometrischen Vermessung und Beschreibung von Einschlüssen in natürlichen sowie im Labor geschaffenen Eispartikeln wurde ein neuartiger Versuchaufbau an der Tomographie-Endstation der Material Science Beam Line an der Swiss Light Source (SLS, Paul Scherrer Institut, Villigen, Schweiz) entwickelt. Dieser besteht aus einer Plexiglas-Tasse und einem doppelwandigen Kaptonfolien-Käfig, der wiederum auf die Düse eines CryojetXL (Oxford Instruments) montiert wurde. Abgesehen von dem hohen Maß an Flexibilit¨at bez¨uglich der Installation erlaubt es dieser Aufbau, die Temperatur des Experiments mit einer Genauigkeit von ± 1 K über einen Bereich von 271 K bis 220 K zu regeln. In den hier beschriebenen Experimenten wurde eine räumliche Auflösung von 1.4 µm erzielt.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Am Mainzer Mikrotron MAMI wurde ein neuartiges Interferometer entwickelt und getestet, mit dem magneto-optische Effekte an dünnen, freitragenden Folien von 3d-Übergangsmetallen wie Eisen, Kobalt oder Nickel an den L_{2,3}-Absorptionskanten (im Spektralbereich der weichen Röntgenstrahlung) gemessen werden können. Es handelt sich um eine Weiterentwicklung eines an MAMI erprobten Interferometers, das im wesentlichen aus einer kollinearen Anordnung zweier identischer Undulatoren, zwischen die die dünne Probefolie eingebracht wird, und einem Gitterspektrometer besteht. Aus den als Funktion des Abstands der Undulatoren beobachtbaren Intensitätsoszillation lassen sich das Dekrement des Realteils δ und der Absorptionskoeffizient β des komplexen Brechungsindex bestimmen.rnIm Rahmen der vorliegenden Arbeit wurde die Apparatur derart weiterentwickelt, dass auch die magnetisch zirkulare Doppelbrechung Δδ und der magnetisch zirkulare Dichroismus Δβ an den L_{2,3}-Absorptionskanten von Übergangsmetallen gemessen werden können. Der zweite Undulator wurde um die Elektronenstrahlachse um den Winkel Ψ = ±107° drehbar gemacht. Damit dient er auch als Analysator der aus der Folie austretenden elliptisch polarisierten weichen Röntgenstrahlung, für die - wie bei der Faraday-Rotation - die Polarisationsebene gedreht ist. Weiterhin kann die Spaltbreite der 10-poligen Hybrid-Undulatoren mit einer Periodenlänge von 12 mm und damit der Undulatorparameter über eine Antriebsmechanik kontinuierlich variiert werden, wodurch eine optimale Anpassung der Amplituden der Undulatorstrahlung aus den beiden Undulatoren möglich wird. Der maximale Undulatorparameter beträgt K = 1.1. Auch das Spektrometer, das auf einem selbstfokussierenden Gitter mit variierter Liniendichte (im Mittel 1400 Linien / mm) basiert, wurde weiterentwickelt. Als Detektor kommt jetzt eine fensterlose CCD mit 1024 x 1024 Pixeln und einer Pixelgröße von 13 μm x 13 μm zum Einsatz, die im Bildmodus betrieben wird, was die gleichzeitige Messung eines Energieintervalls von ca. 50 eV ermöglicht. Die totale Linienbreite wurde bei einer vertikalen Strahlfleckausdehnung von σ_y = 70 μm (rms) am Neon 1s-3p Übergang bei (867.18 ±0.02) eV zu Δħω = (0.218 ±0.002) eV (FWHM) gemessen. Das hohe Auflösungsvermögen von 4000 und die Möglichkeit der Eichung gegen den 1s-3p Übergang von Neon wurden ausgenutzt, um die Energie der Maxima an den Absorptionskanten von Nickel (weiße Linien) neu zu bestimmen. Die Ergebnisse E_{L_2}=(869.65_{-0.16}^{+0.27}) eV und E_{L_3}=(852.37_{-0.11}^{+0.16}) eV stellen eine Verbesserung früherer Messungen dar, die große Streuungen aufwiesen.rnAus systematischen Messungen als Funktion des Abstandes der Undulatoren und des Drehwinkels Ψ wurden die magnetisch zirkulare Doppelbrechung Δδ im Energiebereich 834 eV ≤ ħω ≤ 885 eV an einer freitragenden, bis zur Sättigung magnetisierten Nickelfolie der Dicke von (96.4 ±2.7) nm gemessen. Sowohl das Auflösungsvermögen als auch die Genauigkeit der Messungen für Δδ übersteigen bekannte Literaturangaben signifikant, so dass eine bisher nicht bekannte Feinstruktur gefunden werden konnte. Außerdem wurde der Betrag des magnetisch zirkularen Dichroismus |Δβ| im Bereich des Maximums an der L_3-Absorptionskante mit hoher Genauigkeit gemessen.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, the well-known MC code FLUKA was used to simulate the GE PETrace cyclotron (16.5 MeV) installed at “S. Orsola-Malpighi” University Hospital (Bologna, IT) and routinely used in the production of positron emitting radionuclides. Simulations yielded estimates of various quantities of interest, including: the effective dose distribution around the equipment; the effective number of neutron produced per incident proton and their spectral distribution; the activation of the structure of the cyclotron and the vault walls; the activation of the ambient air, in particular the production of 41Ar, the assessment of the saturation yield of radionuclides used in nuclear medicine. The simulations were validated against experimental measurements in terms of physical and transport parameters to be used at the energy range of interest in the medical field. The validated model was also extensively used in several practical applications uncluding the direct cyclotron production of non-standard radionuclides such as 99mTc, the production of medical radionuclides at TRIUMF (Vancouver, CA) TR13 cyclotron (13 MeV), the complete design of the new PET facility of “Sacro Cuore – Don Calabria” Hospital (Negrar, IT), including the ACSI TR19 (19 MeV) cyclotron, the dose field around the energy selection system (degrader) of a proton therapy cyclotron, the design of plug-doors for a new cyclotron facility, in which a 70 MeV cyclotron will be installed, and the partial decommissioning of a PET facility, including the replacement of a Scanditronix MC17 cyclotron with a new TR19 cyclotron.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

21 cm cosmology opens an observational window to previously unexplored cosmological epochs such as the Epoch of Reionization (EoR), the Cosmic Dawn and the Dark Ages using powerful radio interferometers such as the planned Square Kilometer Array (SKA). Among all the other applications which can potentially improve the understanding of standard cosmology, we study the promising opportunity given by measuring the weak gravitational lensing sourced by 21 cm radiation. We performed this study in two different cosmological epochs, at a typical EoR redshift and successively at a post-EoR redshift. We will show how the lensing signal can be reconstructed using a three dimensional optimal quadratic lensing estimator in Fourier space, using single frequency band or combining multiple frequency band measurements. To this purpose, we implemented a simulation pipeline capable of dealing with issues that can not be treated analytically. Considering the current SKA plans, we studied the performance of the quadratic estimator at typical EoR redshifts, for different survey strategies and comparing two thermal noise models for the SKA-Low array. The simulation we performed takes into account the beam of the telescope and the discreteness of visibility measurements. We found that an SKA-Low interferometer should obtain high-fidelity images of the underlying mass distribution in its phase 1 only if several bands are stacked together, covering a redshift range that goes from z=7 to z=11.5. The SKA-Low phase 2, modeled in order to improve the sensitivity of the instrument by almost an order of magnitude, should be capable of providing images with good quality even when the signal is detected within a single frequency band. Considering also the serious effect that foregrounds could have on this detections, we discussed the limits of these results and also the possibility provided by these models of measuring an accurate lensing power spectrum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monte Carlo (MC) based dose calculations can compute dose distributions with an accuracy surpassing that of conventional algorithms used in radiotherapy, especially in regions of tissue inhomogeneities and surface discontinuities. The Swiss Monte Carlo Plan (SMCP) is a GUI-based framework for photon MC treatment planning (MCTP) interfaced to the Eclipse treatment planning system (TPS). As for any dose calculation algorithm, also the MCTP needs to be commissioned and validated before using the algorithm for clinical cases. Aim of this study is the investigation of a 6 MV beam for clinical situations within the framework of the SMCP. In this respect, all parts i.e. open fields and all the clinically available beam modifiers have to be configured so that the calculated dose distributions match the corresponding measurements. Dose distributions for the 6 MV beam were simulated in a water phantom using a phase space source above the beam modifiers. The VMC++ code was used for the radiation transport through the beam modifiers (jaws, wedges, block and multileaf collimator (MLC)) as well as for the calculation of the dose distributions within the phantom. The voxel size of the dose distributions was 2mm in all directions. The statistical uncertainty of the calculated dose distributions was below 0.4%. Simulated depth dose curves and dose profiles in terms of [Gy/MU] for static and dynamic fields were compared with the corresponding measurements using dose difference and γ analysis. For the dose difference criterion of ±1% of D(max) and the distance to agreement criterion of ±1 mm, the γ analysis showed an excellent agreement between measurements and simulations for all static open and MLC fields. The tuning of the density and the thickness for all hard wedges lead to an agreement with the corresponding measurements within 1% or 1mm. Similar results have been achieved for the block. For the validation of the tuned hard wedges, a very good agreement between calculated and measured dose distributions was achieved using a 1%/1mm criteria for the γ analysis. The calculated dose distributions of the enhanced dynamic wedges (10°, 15°, 20°, 25°, 30°, 45° and 60°) met the criteria of 1%/1mm when compared with the measurements for all situations considered. For the IMRT fields all compared measured dose values agreed with the calculated dose values within a 2% dose difference or within 1 mm distance. The SMCP has been successfully validated for a static and dynamic 6 MV photon beam, thus resulting in accurate dose calculations suitable for applications in clinical cases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Radiotherapy has shown some efficacy for epilepsies but the insufficient confinement of the radiation dose to the pathological target reduces its indications. Synchrotron-generated X-rays overcome this limitation and allow the delivery of focalized radiation doses to discrete brain volumes via interlaced arrays of microbeams (IntMRT). Here, we used IntMRT to target brain structures involved in seizure generation in a rat model of absence epilepsy (GAERS). We addressed the issue of whether and how synchrotron radiotherapeutic treatment suppresses epileptic activities in neuronal networks. IntMRT was used to target the somatosensory cortex (S1Cx), a region involved in seizure generation in the GAERS. The antiepileptic mechanisms were investigated by recording multisite local-field potentials and the intracellular activity of irradiated S1Cx pyramidal neurons in vivo. MRI and histopathological images displayed precise and sharp dose deposition and revealed no impairment of surrounding tissues. Local-field potentials from behaving animals demonstrated a quasi-total abolition of epileptiform activities within the target. The irradiated S1Cx was unable to initiate seizures, whereas neighboring non-irradiated cortical and thalamic regions could still produce pathological oscillations. In vivo intracellular recordings showed that irradiated pyramidal neurons were strongly hyperpolarized and displayed a decreased excitability and a reduction of spontaneous synaptic activities. These functional alterations explain the suppression of large-scale synchronization within irradiated cortical networks. Our work provides the first post-irradiation electrophysiological recordings of individual neurons. Altogether, our data are a critical step towards understanding how X-ray radiation impacts neuronal physiology and epileptogenic processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We performed a Rey visual design learning test (RVDLT) in 17 subjects and measured intervoxel coherence (IC) by DTI as an indication of connectivity to investigate if visual memory performance would depend on white matter structure in healthy persons. IC considers the orientation of the adjacent voxels and has a better signal-to-noise ratio than the commonly used fractional anisotropy index. Voxel-based t-test analysis of the IC values was used to identify neighboring voxel clusters with significant differences between 7 low and 10 high test performers. We detected 9 circumscribed significant clusters (p< .01) with lower IC values in low performers than in high performers, with centers of gravity located in left and right superior temporal region, corpus callosum, left superior longitudinal fascicle, and left optic radiation. Using non-parametric correlation analysis, IC and memory performance were significantly correlated in each of the 9 clusters (r< .61 to r< .81; df=15, p< .01 to p< .0001). The findings provide in vivo evidence for the contribution of white matter structure to visual memory in healthy people.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response necessitates predictive models of respiratory tumor motion to synchronize radiation delivery. Predicting a complex process such as respiratory motion introduces geometric errors, which have been reported in several publications. However, the dosimetric effect of such errors on 4D radiation delivery has not yet been investigated. Thus, our aim in this work was to quantify the dosimetric effects of geometric error due to prediction under several different conditions. Conformal and intensity modulated radiation therapy (IMRT) plans for a lung patient were generated for anterior-posterior/posterior-anterior (AP/PA) beam arrangements at 6 and 18 MV energies to provide planned dose distributions. Respiratory motion data was obtained from 60 diaphragm-motion fluoroscopy recordings from five patients. A linear adaptive filter was employed to predict the tumor position. The geometric error of prediction was defined as the absolute difference between predicted and actual positions at each diaphragm position. Distributions of geometric error of prediction were obtained for all of the respiratory motion data. Planned dose distributions were then convolved with distributions for the geometric error of prediction to obtain convolved dose distributions. The dosimetric effect of such geometric errors was determined as a function of several variables: response time (0-0.6 s), beam energy (6/18 MV), treatment delivery (3D/4D), treatment type (conformal/IMRT), beam direction (AP/PA), and breathing training type (free breathing/audio instruction/visual feedback). Dose difference and distance-to-agreement analysis was employed to quantify results. Based on our data, the dosimetric impact of prediction (a) increased with response time, (b) was larger for 3D radiation therapy as compared with 4D radiation therapy, (c) was relatively insensitive to change in beam energy and beam direction, (d) was greater for IMRT distributions as compared with conformal distributions, (e) was smaller than the dosimetric impact of latency, and (f) was greatest for respiration motion with audio instructions, followed by visual feedback and free breathing. Geometric errors of prediction that occur during 4D radiation delivery introduce dosimetric errors that are dependent on several factors, such as response time, treatment-delivery type, and beam energy. Even for relatively small response times of 0.6 s into the future, dosimetric errors due to prediction could approach delivery errors when respiratory motion is not accounted for at all. To reduce the dosimetric impact, better predictive models and/or shorter response times are required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC source model (with target, primary collimator, and flattening filter photon subsources and an electron subsource) for 6- and 18-MV photon beams when the energy and radial distributions of initial electrons striking a linac target change. For this purpose, phase-space data (PSD) was calculated for various mean electron energies striking the target, various normally distributed electron energy spread, and various normally distributed electron radial intensity distributions. All PSD was analyzed in terms of energy, fluence, and energy fluence distributions, which were compared between the different parameter sets. The energy spread was found to have a negligible influence on the subsource distributions. The mean energy and radial intensity significantly changed the target subsource distribution shapes and intensities. For the primary collimator and flattening filter subsources, the distribution shapes of the fluence and energy fluence changed little for different mean electron energies striking the target, however, their relative intensity compared with the target subsource change, which can be accounted for by a scaling factor. This study indicates that adjustments to MC source models can likely be limited to adjusting the target subsource in conjunction with scaling the relative intensity and energy spectrum of the primary collimator, flattening filter, and electron subsources when the energy and radial distributions of the initial electron-beam change.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Different codes are used for Monte Carlo (MC) calculations in radiation therapy. In this research, MCNP4C and GEANT3 codes have been compared in calculations of dosimetric characteristics of Varian Clinac 2300C/D. The parameters of influence in the differences seen in dosimetric features were discussed. This study emphasizes that both MCNP4C and GEANT3 MC can be used in radiation therapy computations and their differences in photon spectra calculations have a negligible effect on percentage depth dose computations in radiation therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A major barrier to widespread clinical implementation of Monte Carlo dose calculation is the difficulty in characterizing the radiation source within a generalized source model. This work aims to develop a generalized three-component source model (target, primary collimator, flattening filter) for 6- and 18-MV photon beams that match full phase-space data (PSD). Subsource by subsource comparison of dose distributions, using either source PSD or the source model as input, allows accurate source characterization and has the potential to ease the commissioning procedure, since it is possible to obtain information about which subsource needs to be tuned. This source model is unique in that, compared to previous source models, it retains additional correlations among PS variables, which improves accuracy at nonstandard source-to-surface distances (SSDs). In our study, three-dimensional (3D) dose calculations were performed for SSDs ranging from 50 to 200 cm and for field sizes from 1 x 1 to 30 x 30 cm2 as well as a 10 x 10 cm2 field 5 cm off axis in each direction. The 3D dose distributions, using either full PSD or the source model as input, were compared in terms of dose-difference and distance-to-agreement. With this model, over 99% of the voxels agreed within +/-1% or 1 mm for the target, within 2% or 2 mm for the primary collimator, and within +/-2.5% or 2 mm for the flattening filter in all cases studied. For the dose distributions, 99% of the dose voxels agreed within 1% or 1 mm when the combined source model-including a charged particle source and the full PSD as input-was used. The accurate and general characterization of each photon source and knowledge of the subsource dose distributions should facilitate source model commissioning procedures by allowing scaling the histogram distributions representing the subsources to be tuned.