885 resultados para validation of methods
Resumo:
Capillary electrophoresis method designed originally for the analysis of monosaccharides was validated using reference solutions of polydatin. The validation was conducted by studying and determining the concentration levels of LOD and LOQ and the range of linearity and by determining levels of uncertainty in respect to repeatability and reproducibility. The reliability of the gained results is also discussed. A guide with recommendations considering the validation and overall design of analysis sequences with CE is also produced as a result of this study.
Resumo:
The objective of the present study was to validate the transit-time technique for long-term measurements of iliac and renal blood flow in rats. Flow measured with ultrasonic probes was confirmed ex vivo using excised arteries perfused at varying flow rates. An implanted 1-mm probe reproduced with accuracy different patterns of flow relative to pressure in freely moving rats and accurately quantitated the resting iliac flow value (on average 10.43 ± 0.99 ml/min or 2.78 ± 0.3 ml min-1 100 g body weight-1). The measurements were stable over an experimental period of one week but were affected by probe size (resting flows were underestimated by 57% with a 2-mm probe when compared with a 1-mm probe) and by anesthesia (in the same rats, iliac flow was reduced by 50-60% when compared to the conscious state). Instantaneous changes of iliac and renal flow during exercise and recovery were accurately measured by the transit-time technique. Iliac flow increased instantaneously at the beginning of mild exercise (from 12.03 ± 1.06 to 25.55 ± 3.89 ml/min at 15 s) and showed a smaller increase when exercise intensity increased further, reaching a plateau of 38.43 ± 1.92 ml/min at the 4th min of moderate exercise intensity. In contrast, exercise-induced reduction of renal flow was smaller and slower, with 18% and 25% decreases at mild and moderate exercise intensities. Our data indicate that transit-time flowmetry is a reliable method for long-term and continuous measurements of regional blood flow at rest and can be used to quantitate the dynamic flow changes that characterize exercise and recovery
Resumo:
The purpose of the present study was to translate the Roland-Morris (RM) questionnaire into Brazilian-Portuguese and adapt and validate it. First 3 English teachers independently translated the original questionnaire into Brazilian-Portuguese and a consensus version was generated. Later, 3 other translators, blind to the original questionnaire, performed a back translation. This version was then compared with the original English questionnaire. Discrepancies were discussed and solved by a panel of 3 rheumatologists and the final Brazilian version was established (Brazil-RM). This version was then pretested on 30 chronic low back pain patients consecutively selected from the spine disorders outpatient clinic. In addition to the traditional clinical outcome measures, the Brazil-RM, a 6-point pain scale (from no pain to unbearable pain), and its numerical pain rating scale (PS) (0 to 5) and a visual analog scale (VAS) (0 to 10) were administered twice by one interviewer (1 week apart) and once by one independent interviewer. Spearman's correlation coefficient (SCC) and intraclass correlation coefficient (ICC) were computed to assess test-retest and interobserver reliability. Cross-sectional construct validity was evaluated using the SCC. In the pretesting session, all questions were well understood by the patients. The mean time of questionnaire administration was 4 min and 53 s. The SCC and ICC were 0.88 (P<0.01) and 0.94, respectively, for the test-retest reliability and 0.86 (P<0.01) and 0.95, respectively, for interobserver reliability. The correlation coefficient was 0.80 (P<0.01) between the PS and Brazil-RM score and 0.79 (P<0.01) between the VAS and Brazil-RM score. We conclude that the Brazil-RM was successfully translated and adapted for application to Brazilian patients, with satisfactory reliability and cross-sectional construct validity.
Resumo:
We tested the correlation of the albumin-to-creatinine ratio (A/C) in an early-morning urine sample, measured with a commercial kit (DCA 2000®), with the conventional immunoturbidimetric determination in the laboratory and with overnight albumin excretion rate (reference method). Fifty-five type 1 diabetic adolescents had their first-morning urine collected on the 1st and 8th day of the period. Urinary albumin and creatinine were determined immediately using the DCA 2000® kit. Samples were also stored for laboratory analysis. To evaluate the correlation between early-morning urinary A/C ratio and overnight albumin excretion rate, 16 subjects had a timed overnight urine collection. A/C ratios determined with the DCA 2000® kit and by the laboratory method were 13.1 ± 20.5 and 20.4 ± 46.3 mg/g, respectively. A/C results by both methods proved to be strongly correlated (r = 0.98, P<0.001). DCA 2000®-determined A/C showed 50% sensitivity and 100% specificity when compared to the reference method. Spot urinary A/C of the subset of 16 subjects significantly correlated with their overnight albumin excretion rate (r = 0.98, P<0.001). Intraindividual variation ranged from 17 to 32% and from 9 to 63% for A/C and overnight albumin excretion rate, respectively. In conclusion, an early-morning specimen should be used instead of timed overnight urine and the A/C ratio is an accurate, reliable and easily determined parameter for the screening of diabetic nephropathy. Immediate measurement of the A/C ratio is feasible using the DCA 2000® kit. Intraindividual variability indicates the need for repeated determinations to confirm microalbuminuria and the diagnosis of incipient diabetic nephropathy.
Resumo:
The phonological loop is a component of the working memory system specifically involved in the processing and manipulation of limited amounts of information of a sound-based phonological nature. Phonological memory can be assessed by the Children's Test of Nonword Repetition (CNRep) in English speakers but not in Portuguese speakers due to phonotactic differences between the two languages. The objectives of the present study were: 1) to develop the Brazilian Children's Test of Pseudoword Repetition (BCPR), a Portuguese version of the CNRep, and 2) to validate the BCPR by correlation with the Auditory Digit Span Test from the Stanford-Binet Intelligence Scale. The BCPR and Digit Span were assessed in 182 children aged 4-10 years, 84 from Minas Gerais State (42 from a rural region) and 98 from the city of São Paulo. There are subject age and word length effects causing repetition accuracy to decline as a function of the number of syllables of the pseudowords. Correlations between BCPR and Digit Span forward (r = 0.50; P <= 0.01) and backward (r = 0.43; P <= 0.01) were found, and partial correlation indicated that higher BCPR scores were associated with higher Digit Span scores. BCPR appears to depend more on schooling, while Digit Span was more related to development. The results demonstrate that the BCPR is a reliable measure of phonological working memory, similar to the CNRep.
Resumo:
A gravimetric method was evaluated as a simple, sensitive, reproducible, low-cost alternative to quantify the extent of brain infarct after occlusion of the medial cerebral artery in rats. In ether-anesthetized rats, the left medial cerebral artery was occluded for 1, 1.5 or 2 h by inserting a 4-0 nylon monofilament suture into the internal carotid artery. Twenty-four hours later, the brains were processed for histochemical triphenyltetrazolium chloride (TTC) staining and quantitation of the schemic infarct. In each TTC-stained brain section, the ischemic tissue was dissected with a scalpel and fixed in 10% formalin at 0ºC until its total mass could be estimated. The mass (mg) of the ischemic tissue was weighed on an analytical balance and compared to its volume (mm³), estimated either by plethysmometry using platinum electrodes or by computer-assisted image analysis. Infarct size as measured by the weighing method (mg), and reported as a percent (%) of the affected (left) hemisphere, correlated closely with volume (mm³, also reported as %) estimated by computerized image analysis (r = 0.88; P < 0.001; N = 10) or by plethysmography (r = 0.97-0.98; P < 0.0001; N = 41). This degree of correlation was maintained between different experimenters. The method was also sensitive for detecting the effect of different ischemia durations on infarct size (P < 0.005; N = 23), and the effect of drug treatments in reducing the extent of brain damage (P < 0.005; N = 24). The data suggest that, in addition to being simple and low cost, the weighing method is a reliable alternative for quantifying brain infarct in animal models of stroke.
Resumo:
The objective of the present study was to translate the Kidney Disease Quality of Life - Short Form (KDQOL-SF™1.3) questionnaire into Portuguese to adapt it culturally and validate it for the Brazilian population. The KDQOL-SF was translated into Portuguese and back-translated twice into English. Patient difficulties in understanding the questionnaire were evaluated by a panel of experts and solved. Measurement properties such as reliability and validity were determined by applying the questionnaire to 94 end-stage renal disease patients on chronic dialysis. The Nottingham Health Profile Questionnaire, the Karnofsky Performance Scale and the Kidney Disease Questionnaire were administered to test validity. Some activities included in the original instrument were considered to be incompatible with the activities usually performed by the Brazilian population and were replaced. The mean scores for the 19 components of the KDQOL-SF questionnaire in Portuguese ranged from 22 to 91. The components "Social support" and "Dialysis staff encouragement" had the highest scores (86.7 and 90.8, respectively). The test-retest reliability and the inter-observer reliability of the instrument were evaluated by the intraclass correlation coefficient. The coefficients for both reliability tests were statistically significant for all scales of the KDQOL-SF (P < 0.001), ranging from 0.492 to 0.936 for test-retest reliability and from 0.337 to 0.994 for inter-observer reliability. The Cronbach's alpha coefficient was higher than 0.80 for most of components. The Portuguese version of the KDQOL-SF questionnaire proved to be valid and reliable for the evaluation of quality of life of Brazilian patients with end-stage renal disease on chronic dialysis.
Resumo:
The objective of the present study was to investigate the psychometric properties and cross-cultural validity of the Beck Depression Inventory (BDI) among ethnic Chinese living in the city of São Paulo, Brazil. The study was conducted on 208 community individuals. Reliability and discriminant analysis were used to test the psychometric properties and validity of the BDI. Principal component analysis was performed to assess the BDI's factor structure for the total sample and by gender. The mean BDI score was lower (6.74, SD = 5.98) than observed in Western counterparts and showed no gender difference, good internal consistency (Cronbach's alpha 0.82), and high discrimination of depressive symptoms (75-100%). Factor analysis extracted two factors for the total sample and each gender: cognitive-affective dimension and somatic dimension. We conclude that depressive symptoms can be reliably assessed by the BDI in the Brazilian Chinese population, with a validity comparable to that for international studies. Indeed, cultural and measurement biases might have influenced the response of Chinese subjects.
Resumo:
The purpose of the present study was to examine the factor structure and psychometric properties of the Social Phobia and Anxiety Inventory for Children (SPAI-C), an instrument developed in the United States and applied to a sample of Brazilian schoolchildren. The process included the translation of the original material from English into Portuguese by two bilingual psychiatrists and a back translation by a bilingual physician. Both the front and back translations were revised by a bilingual child psychiatrist. The study was performed using a cross-sectional design and the Portuguese version of the SPAI-C was applied to a sample of 1954 children enrolled in 3rd to 8th grade attending 2 private and 11 public schools. Eighty-one subjects were excluded due to an incomplete questionnaire and 2 children refused to participate. The final sample consisted of 1871 children, 938 girls (50.1%) and 933 boys (49.8%), ranging in age from 9 to 14 years. The majority of the students were Caucasian (89.0%) and the remainder were African-Brazilian (11.0%). The Pearson product-moment correlation showed that the two-week test-retest reliability coefficient was r = 0.780 and Cronbach's alpha was 0.946. The factor structure was almost similar to that reported in previous studies. The results regarding the internal consistency, the test-retest reliability and the factor structure were similar to the findings obtained in studies performed on English speaking children. The present study showed that the Portuguese language version of SPAI-C is a reliable and valid measure of social anxiety for Brazilian children.
Severity score system for progressive myelopathy: development and validation of a new clinical scale
Resumo:
Progressive myelopathies can be secondary to inborn errors of metabolism (IEM) such as mucopolysaccharidosis, mucolipidosis, and adrenomyeloneuropathy. The available scale, Japanese Orthopaedic Association (JOA) score, was validated only for degenerative vertebral diseases. Our objective is to propose and validate a new scale addressing progressive myelopathies and to present validating data for JOA in these diseases. A new scale, Severity Score System for Progressive Myelopathy (SSPROM), covering motor disability, sphincter dysfunction, spasticity, and sensory losses. Inter- and intra-rater reliabilities were measured. External validation was tested by applying JOA, the Expanded Disability Status Scale (EDSS), the Barthel index, and the Osame Motor Disability Score. Thirty-eight patients, 17 with adrenomyeloneuropathy, 3 with mucopolysaccharidosis I, 3 with mucopolysaccharidosis IV, 2 with mucopolysaccharidosis VI, 2 with mucolipidosis, and 11 with human T-cell lymphotropic virus type-1 (HTLV-1)-associated myelopathy participated in the study. The mean ± SD SSPROM and JOA scores were 74.6 ± 11.4 and 12.4 ± 2.3, respectively. Construct validity for SSPROM (JOA: r = 0.84, P < 0.0001; EDSS: r = -0.83, P < 0.0001; Barthel: r = 0.56, P < 0.002; Osame: r = -0.94, P < 0.0001) and reliability (intra-rater: r = 0.83, P < 0.0001; inter-rater: r = 0.94, P < 0.0001) were demonstrated. The metric properties of JOA were similar to those found in SSPROM. Several clinimetric requirements were met for both SSPROM and JOA scales. Since SSPROM has a wider range, it should be useful for follow-up studies on IEM myelopathies.
Resumo:
Hepatitis E virus (HEV) is classified within the family Hepeviridae, genus Hepevirus. HEV genotype 3 (Gt3) infections are endemic in pigs in Western Europe and in North and South America and cause zoonotic infections in humans. Several serological assays to detect HEV antibodies in pigs have been developed, at first mainly based on HEV genotype 1 (Gt1) antigens. To develop a sensitive HEV Gt3 ELISA, a recombinant baculovirus expression product of HEV Gt3 open reading frame-2 was produced and coated onto polystyrene ELISA plates. After incubation of porcine sera, bound HEV antibodies were detected with anti-porcine anti-IgG and anti-IgM conjugates. For primary estimation of sensitivity and specificity of the assay, sets of sera were used from pigs experimentally infected with HEV Gt3. For further validation of the assay and to set the cutoff value, a batch of 1100 pig sera was used. All pig sera were tested using the developed HEV Gt3 assay and two other serologic assays based on HEV Gt1 antigens. Since there is no gold standard available for HEV antibody testing, further validation and a definite setting of the cutoff of the developed HEV Gt3 assay were performed using a statistical approach based on Bayes' theorem. The developed and validated HEV antibody assay showed effective detection of HEV-specific antibodies. This assay can contribute to an improved detection of HEV antibodies and enable more reliable estimates of the prevalence of HEV Gt3 in swine in different regions.
Resumo:
Milk and egg matrixes were assayed for aflatoxin M1 (AFM1) and B1 (AFB1) respectively, by AOAC official and modified methods with detection and quantification by thin layer chromatography (TLC) and high performance thin layer chromatography (HPTLC). The modified methods: Blanc followed by Romer, showed to be most appropriate for AFM1 analysis in milk. Both methods reduced emulsion formation, produced cleaner extracts, no streaking spots, precision and accuracy improved, especially when quantification was performed by HPTLC. The use of ternary mixture in the Blanc Method was advantageous as the solvent could extract AFM1 directly from the first stage (extraction), leaving other compounds in the binary mixture layer, avoiding emulsion formation, thus reducing toxin loss. The relative standard deviation (RSD%) values were low, 16 and 7% when TLC and HPTLC were used, with a mean recovery of 94 and 97%, respectively. As far as egg matrix and final extract are concerned, both methods evaluated for AFB1 need further studies. Although that matrix leads to emulsion with consequent loss of toxin, the Romer modified presented a reasonable clean extract (mean recovery of 92 and 96% for TLC and HPTLC, respectively). Most of the methods studied did not performed as expected mainly due to the matrixes high content of triglicerides (rich on saturated fatty acids), cholesterol, carotene and proteins. Although nowadays most methodology for AFM1 is based on HPLC, TLC determination (Blanc and Romer modified) for AFM1 and AFB1 is particularly recommended to those, inexperienced in food and feed mycotoxins analysis and especially who cannot afford to purchase sophisticated (HPLC,HPTLC) instrumentation.
Resumo:
The Graphite furnace atomic absorption spectrometry (GF AAS) was the technique chosen by the inorganic contamination laboratory (INCQ/ FIOCRUZ) to be validated and applied in routine analysis for arsenic detection and quantification. The selectivity, linearity, sensibility, detection, and quantification limits besides accuracy and precision parameters were studied and optimized under Stabilized Temperature Platform Furnace (STPF) conditions. The limit of detection obtained was 0.13 µg.L-1 and the limit of quantification was 1.04 µg.L-1, with an average precision, for total arsenic, less than 15% and an accuracy of 96%. To quantify the chemical species As(III) and As(V), an ion-exchange resin (Dowex 1X8, Cl- form) was used and the physical-chemical parameters were optimized resulting in a recuperation of 98% of As(III) and of 90% of As(V). The method was applied to groundwater, mineral water, and hemodialysis purified water samples. All results obtained were lower than the maximum limit values established by the legal Brazilian regulations, in effect, 50, 10, and 5 µg.L-1 para As total, As(III) e As(V), respectively. All results were statistically evaluated.
Resumo:
A method using Liquid Chromatography Tanden Mass Spectrometry (LC-MS/MS) with matrix-matched calibration curve was developed and validated for determining ochratoxin A (OTA) in green coffee. Linearity was found between 3.0 and 23.0 ng.g-1. Mean recoveries ranged between 90.45% and 108.81%; the relative standard deviation under repeatability and intermediate precision conditions ranged from 5.39% to 9.94% and from 2.20% to 14.34%, respectively. The limits of detection and quantification were 1.2 ng.g-1 and 3.0 ng.g-¹, respectively. The method developed was suitable and contributed to the field of mycotoxin analysis, and it will be used for future production of the Certified Reference Material (CRM) for OTA in coffee.
Resumo:
Most soybean pathogens are seed transmitted, deserving emphasis the fungus Sclerotinia sclerotiorum, which has been presenting worrying levels of field incidence in some soybean cropping areas in several Brazilian states. The objective of this study was to verify the efficiency of different methods for detecting S. sclerotiorum on soybean seeds artificially infected in the laboratory and from field production areas with a historical disease incidence. Seed samples of seven different cultivars collected from naturally infested fields, and one seed sample artificially inoculated in the laboratory were used. The following detection methods recommended in the literature were compared: Blotter test at 7 ºC, 14 ºC, and 21 ºC; Rolled Paper; and Neon-S. Results demonstrated that these methods showed no repeatability and had a low sensitivity for detecting the pathogen in seeds from areas with disease incidence. They were effective, however, for its detection on artificially inoculated seeds. In the Blotter test method at 7 ºC, there was a lower incidence of other fungi considered undesirable during seed analysis.