964 resultados para protocol program
Resumo:
Microbial adhesion is a field of recognized relevance and, as such, an impressive array of tools has been developed to understand its molecular mechanisms and ultimately for its quantification. Some of the major limitations found within these methodologies concern the incubation time, the small number of cells analyzed, and the operator's subjectivity. To overcome these aspects, we have developed a quantitative method to measure yeast cells' adhesion through flow cytometry. In this methodology, a suspension of yeast cells is mixed with green fluorescent polystyrene microspheres (uncoated or coated with host proteins). Within 2 h, an adhesion profile is obtained based on two parameters: percentage and cells-microsphere population's distribution pattern. This flow cytometry protocol represents a useful tool to quantify yeast adhesion to different substrata in a large scale, providing manifold data in a speedy and informative manner.
Resumo:
RESUMO: Objetivos – Determinar a sensibilidade e especificidade das ponderações Difusão (DWI) e T2 Fluid-Attenuated Inversion Recovery (FLAIR) na avaliação de lesões da substância branca (SB) e verificar em que medida se complementam, por forma a criar um conjunto de boas práticas na RM cranioencefálica de rotina. Metodologia – Recorrendo-se a uma metodologia quantitativa, efetuou-se uma análise retrospetiva da qual foram selecionados 30 pacientes, 10 sem patologia e 20 com patologia (2 com EM, 7 com Leucoencefalopatia, 6 com doença microangiopática e 5 com patologia da substância branca indefinida). Obteve-se uma amostra de 60 imagens, nomeadamente: 30 imagens ponderadas em DWI e 30 em T2 FLAIR. Recorrendo ao programa Viewdex®, três observadores avaliaram um conjunto de imagens segundo sete critérios: visibilidade, deteção, homogeneidade, localização, margens e dimensões da lesão e capacidade de diagnóstico. Com os resultados obtidos recorreu-se ao cálculo de sensibilidade e especificidade pelas Curvas ROC, bem como à análise estatística, nomeadamente, Teste-T, Índice de Concordância Kappa e coeficiente de correlação de Pearson entre as variáveis em estudo. Resultados – Os resultados de sensibilidade e de especificidade obtidos para a ponderação T2 FLAIR foram superiores (0,915 e 0,038, respetivamente) aos da ponderação DWI (0,08 e 0,100, respetivamente). Não se verificaram variâncias populacionais significativas. Obteve-se uma elevada correlação linear entre as variáveis com um valor r situado entre 0,8 e 0,99. Verificou-se também uma variabilidade considerável entre os observadores. Conclusões – Dados os baixos valores de sensibilidade e especificidade obtidos para a DWI, sugere-se que esta deva ser incluída no protocolo de rotina de crânio como auxiliar no diagnóstico diferencial com outras patologias.
Revisão sistemática da resposta da musculatura esquelética aos programas de treino em microgravidade
Resumo:
Mestrado em Fisioterapia.
Resumo:
Mathematical Program with Complementarity Constraints (MPCC) finds applica- tion in many fields. As the complementarity constraints fail the standard Linear In- dependence Constraint Qualification (LICQ) or the Mangasarian-Fromovitz constraint qualification (MFCQ), at any feasible point, the nonlinear programming theory may not be directly applied to MPCC. However, the MPCC can be reformulated as NLP problem and solved by nonlinear programming techniques. One of them, the Inexact Restoration (IR) approach, performs two independent phases in each iteration - the feasibility and the optimality phases. This work presents two versions of an IR algorithm to solve MPCC. In the feasibility phase two strategies were implemented, depending on the constraints features. One gives more importance to the complementarity constraints, while the other considers the priority of equality and inequality constraints neglecting the complementarity ones. The optimality phase uses the same approach for both algorithm versions. The algorithms were implemented in MATLAB and the test problems are from MACMPEC collection.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores
Resumo:
Introdução: A artroplastia total do ombro é largamente aceite como tratamento para uma variedade de patologias do ombro com dor persistente e perda acentuada da funcionalidade. Em termos globais, os resultados obtidos após a intervenção cirúrgica são bastante bons, parecendo estar, no entanto, condicionados com a patologia subjacente e a qualidade da coifa dos rotadores. Objectivo: Pretende-se com este trabalho descrever e avaliar a eficácia de um plano de intervenção numa prótese total do ombro com integridade da coifa dos rotadores. Metodologia: Paciente sexo feminino, 61 anos, reformada, com dor acentuada no ombro esquerdo desde há três anos, submetida a uma cirurgia de colocação de prótese total do ombro. Apresentava limitação da amplitude articular, diminuição da força, alteração do ritmo escapulo-umeral e ligeira incapacidade funcional. Cinco semanas após a cirurgia, iniciou sessões diárias de fisioterapia durante 12 semanas. A intervenção incluiu a aplicação de modalidades anti-álgicas, mobilização articular, fortalecimento muscular e reeducação neuromuscular. Foi avaliada em quatro momentos: antes da intervenção (M1), 4 (M2), 7 (M3) e 12 (M4) semanas após. Resultados: A dor diminuiu de 4 para 0 (END) no final de 7 semanas e as amplitudes articulares passivas aproximaram-se dos valores definidos pelo protocolo com a flexão/elevação anterior a evoluir de 90º para 130º; a abdução/elevação lateral de 80º para 110º e a rotação medial de 35º para 70º. A força muscular inicial era de 3 nos grupos musculares flexores, extensores e rotadores do ombro atingindo no final grau 4. O ritmo escapulo-umeral demonstrou assincronia durante a elevação do ombro na primeira avaliação, ficando quase normalizado no final das sessões. Quanto à funcionalidade, antes da intervenção o score obtido foi de 30.8 atingindo um valor de 11.6 no final das sessões de tratamento. Conclusão: Após 12 semanas de tratamento, os objectivos delineados foram praticamente atingidos, uma vez que a utente já não refere dor no ombro e apresenta uma boa capacidade funcional, apesar de apresentar ligeiras diferenças nas amplitudes articulares e força muscular esperadas, apontando para o sucesso do protocolo de tratamento aplicado.
Resumo:
Mestrado em Engenharia Química
Resumo:
The aim of this study is to examine the implications of the IPPA in the perception of illness and wellbeing in MS patients. Methods - This is a quasi experimental study non-randomized study with 24 MS patients diagnosed at least 1 year before, and with an EDSS score of under 7. We used the IPPA in 3 groups of eight people in 3 Portuguese hospitals (Lisbon, Coimbra, and Porto). The sessions were held once a week for 90 minutes, over a period of 7 weeks. The instruments used were: We asked the subjects the question “Please classify the severity of your disease?” and used the Personal Wellbeing Scale (PWS) at the beginning (time A) and end (time B) of the IPPA. We used the SPSS version 20. A non-parametric statistical hypothesis test (Wilcoxon test) was used for the variable analysis. The intervention followed the recommendations of the Helsinki Declaration. Results – The results suggest that there are differences between time A and B, the perception of illness decreased (p<0.08), while wellbeing increased (p<0.01). Conclusions: The IPPA can play an important role in modifying the perception of disease severity and personal wellbeing.
Resumo:
Introdução: As doenças cardiovasculares são a principal causa de morte na Europa e o sedentarismo é um dos seus principais fatores de risco. Os programas de reabilitação cardiovascular (RCV) no domicílio parecem ser eficazes na tolerância ao exercício. No entanto, torna-se difícil reproduzir um protocolo de exercícios no domicílio, por se tratar de estudos pouco específicos. Objetivo: Avaliar os efeitos de um programa de exercícios específico realizado no domicílio, na tolerância ao exercício em pacientes integrados num programa RCV. Metodologia: Estudo quase experimental composto por 20 indivíduos com pelo menos um ano de enfarte agudo do miocárdio, distribuídos aleatoriamente em dois grupos: grupo experimental (GE) e grupo de controlo (GC), ambos com 10 indivíduos. O programa de RCV no domicílio (constituído por 10 exercícios) teve a duração de 8 semanas, com uma frequência de 3 vezes por semana. Avaliou-se a frequência cardíaca (FC), tensão arterial e duplo produto basais e máximos; FC de recuperação; equivalentes metabólicos (METs); velocidade; inclinação; tempo de prova e de recuperação; índice cifótico; equilíbrio; e tempo em atividade moderada a vigorosa. Resultados: Ao fim de 8 semanas de exercício o GE aumentou significativamente os MET’s (p=0,001), tensão arterial sistólica máxima (p<0,001), duplo produto máximo (p<0,001) e tempo de prova (p=0,037) e diminuiu significativamente o tempo de recuperação (p<0,001), quando comparado com o GC. Conclusão: O programa de exercícios no domicílio promoveu uma melhoria na tolerância ao exercício e parece ter melhorado o equilíbrio, para a amostra em estudo.
Resumo:
International guidelines recommend a first line therapy in the treatment of female stress urinary incontinence (SUI), the pelvic floor muscle (PFM) training. This case report assesses the effects of the PFM training program in treating women with severe SUI. The urodynamic parameters allow diagnosed intrinsic sphincter deficiency and urethral hypermobility. The subjective and objective parameters were assessed at the beginning and after six-month of PFM training program. This case report confirms the efficiency of the intensive training program in severe SUI. The medical implications of the PFM training as first treatment option reflect favourable individual results and additionally contribute to the selection of the non-invasive treatment, the reduction of the incidence collateral effects, low costs and that does not prevent future treatment options.
Resumo:
Mestrado em Fisioterapia
Resumo:
Wireless Sensor Networks (WSNs) have been attracting increasing interests in the development of a new generation of embedded systems with great potential for many applications such as surveillance, environment monitoring, emergency medical response and home automation. However, the communication paradigms in Wireless Sensor Networks differ from the ones attributed to traditional wireless networks, triggering the need for new communication protocols and mechanisms. In this Technical Report, we present a survey on communication protocols for WSNs with a particular emphasis on the lower protocol layers. We give a particular focus to the MAC (Medium Access Control) sub-layer, since it has a prominent influence on some relevant requirements that must be satisfied by WSN protocols, such as energy consumption, time performance and scalability. We overview some relevant MAC protocol solutions and discuss how they tackle the trade-off between the referred requirements.
Resumo:
The overall goal of the REMPLI project is to design and implement a communication infrastructure for distributed data acquisition and remote control operations using the power grid as the communication medium. The primary target application is remote meter reading with high time resolution, where the meters can be energy, heat, gas, or water meters. The users of the system (e.g. utility companies) will benefit from the REMPLI system by gaining more detailed information about how energy is consumed by the end-users. In this context, the power-line communication (PLC) is deployed to cover the distance between utility company’s Private Network and the end user. This document specifies a protocol for real-time PLC, in the framework of the REMPLI project. It mainly comprises the Network Layer and Data Link Layer. The protocol was designed having into consideration the specific aspects of the network: different network typologies (star, tree, ring, multiple paths), dynamic changes in network topology (due to network maintenance, hazards, etc.), communication lines strongly affected by noise.
Resumo:
A recent trend in distributed computer-controlled systems (DCCS) is to interconnect the distributed computing elements by means of multi-point broadcast networks. Since the network medium is shared between a number of network nodes, access contention exists and must be solved by a medium access control (MAC) protocol. Usually, DCCS impose real-time constraints. In essence, by real-time constraints we mean that traffic must be sent and received within a bounded interval, otherwise a timing fault is said to occur. This motivates the use of communication networks with a MAC protocol that guarantees bounded access and response times to message requests. PROFIBUS is a communication network in which the MAC protocol is based on a simplified version of the timed-token protocol. In this paper we address the cycle time properties of the PROFIBUS MAC protocol, since the knowledge of these properties is of paramount importance for guaranteeing the real-time behaviour of a distributed computer-controlled system which is supported by this type of network.
Resumo:
Future industrial control/multimedia applications will increasingly impose or benefit from wireless and mobile communications. Therefore, there is an enormous eagerness for extending currently available industrial communications networks with wireless and mobility capabilities. The RFieldbus European project is just one example, where a PROFIBUS-based hybrid (wired/wireless) architecture was specified and implemented. In the RFieldbus architecture, interoperability between wired and wireless components is achieved by the use specific intermediate networking systems operating at the physical layer level, i.e. operating as repeaters. Instead, in this paper we will focus on a bridge-based approach, which presents several advantages. This concept was introduced in (Ferreira, et al., 2002), where a bridge-based approach was briefly outlined. Then, a specific Inter-Domain Protocol (IDP) was proposed to handle the Inter-Domain transactions in such a bridge-based approach (Ferreira, et al., 2003a). The major contribution of this paper is in extending these previous works by describing the protocol extensions to support inter-cell mobility in such a bridge-based hybrid wired/wireless PROFIBUS networks.