947 resultados para hyperspectral imaging
Resumo:
AIMS: We studied the respective added value of the quantitative myocardial blood flow (MBF) and the myocardial flow reserve (MFR) as assessed with (82)Rb positron emission tomography (PET)/CT in predicting major adverse cardiovascular events (MACEs) in patients with suspected myocardial ischaemia. METHODS AND RESULTS: Myocardial perfusion images were analysed semi-quantitatively (SDS, summed difference score) and quantitatively (MBF, MFR) in 351 patients. Follow-up was completed in 335 patients and annualized MACE (cardiac death, myocardial infarction, revascularization, or hospitalization for congestive heart failure or de novo stable angor) rates were analysed with the Kaplan-Meier method in 318 patients after excluding 17 patients with early revascularizations (<60 days). Independent predictors of MACEs were identified by multivariate analysis. During a median follow-up of 624 days (inter-quartile range 540-697), 35 MACEs occurred. An annualized MACE rate was higher in patients with ischaemia (SDS >2) (n = 105) than those without [14% (95% CI = 9.1-22%) vs. 4.5% (2.7-7.4%), P < 0.0001]. The lowest MFR tertile group (MFR <1.8) had the highest MACE rate [16% (11-25%) vs. 2.9% (1.2-7.0%) and 4.3% (2.1-9.0%), P < 0.0001]. Similarly, the lowest stress MBF tertile group (MBF <1.8 mL/min/g) had the highest MACE rate [14% (9.2-22%) vs. 7.3% (4.2-13%) and 1.8% (0.6-5.5%), P = 0.0005]. Quantitation with stress MBF or MFR had a significant independent prognostic power in addition to semi-quantitative findings. The largest added value was conferred by combining stress MBF to SDS. This holds true even for patients without ischaemia. CONCLUSION: Perfusion findings in (82)Rb PET/CT are strong MACE outcome predictors. MBF quantification has an added value allowing further risk stratification in patients with normal and abnormal perfusion images.
Resumo:
Background: The role of the non-injured hemisphere in stroke recovery is poorly understood. In this pilot study, we sought to explore the presence of structural changes detectable by diffusion tensor imaging (DTI) in the contralesional hemispheres of patients who recovered well from ischemic stroke. Methods: We analyzed serial DTI data from 16 stroke patients who had moderate initial neurological deficits (NIHSS scores 3-12) and good functional outcome at 3-6 months (NIHSS score 0 or modified Rankin Score ≤1). We segmented the brain tissue in gray and white matter (GM and WM) and measured the apparent diffusion coefficient (ADC) and fractional anisotropy in the infarct, in the contralesional infarct mirror region as well as in concentrically expanding regions around them. Results: We found that GM and WM ADC significantly increased in the infarct region (p < 0.01) from acute to chronic time points, whereas in the infarct mirror region, GM and WM ADC increased (p < 0.01) and WM fractional anisotropy decreased (p < 0.05). No significant changes were detected in other regions. Conclusion: DTI-based metrics are sensitive to regional structural changes in the contralesional hemisphere during stroke recovery. Prospective studies in larger cohorts with varying levels of recovery are needed to confirm our findings.
Resumo:
PURPOSE: To develop a breathhold method for black-blood viability imaging of the heart that may facilitate identifying the endocardial border. MATERIALS AND METHODS: Three stimulated-echo acquisition mode (STEAM) images were obtained almost simultaneously during the same acquisition using three different demodulation values. Two of the three images were used to construct a black-blood image of the heart. The third image was a T(1)-weighted viability image that enabled detection of hyperintense infarcted myocardium after contrast agent administration. The three STEAM images were combined into one composite black-blood viability image of the heart. The composite STEAM images were compared to conventional inversion-recovery (IR) delayed hyperenhanced (DHE) images in nine human subjects studied on a 3T MRI scanner. RESULTS: STEAM images showed black-blood characteristics and a significant improvement in the blood-infarct signal-difference to noise ratio (SDNR) when compared to the IR-DHE images (34 +/- 4.1 vs. 10 +/- 2.9, mean +/- standard deviation (SD), P < 0.002). There was sufficient myocardium-infarct SDNR in the STEAM images to accurately delineate infarcted regions. The extracted infarcts demonstrated good agreement with the IR-DHE images. CONCLUSION: The STEAM black-blood property allows for better delineation of the blood-infarct border, which would enhance the fast and accurate measurement of infarct size.
Resumo:
Assuming selective vulnerability of short association U-fibers in early Alzheimer's disease (AD), we quantified demyelination of the surface white matter (dSWM) with magnetization transfer ratio (MTR) in 15 patients (Clinical Dementia Rating Scale [CDR] 0.5-1; Functional Assessment Staging [FAST]: 3-4) compared with 15 controls. MTRs were computed for 39 areas in each hemisphere. We found a bilateral MTR decrease in the temporal, cingulate, parietal, and prefrontal areas. With linear discriminant analysis, we successfully classified all the participants with 3 variates including the cuneus, parahippocampal, and superior temporal regions of the left hemisphere. The pattern of dSWM changed with the age of AD onset. In early onset patients, we found bilateral posterior demyelination spreading to the temporal areas in the left hemisphere. The late onset patients showed a distributed bilateral pattern with the temporal and cingulate areas strongly affected. A correlation with Mini Mental State Examination (MMSE), Lexis, and memory tests revealed the dSWM impact on cognition. A specific landscape of dSWM in early AD shows the potential of MTR imaging as an in vivo biomarker superior to currently used techniques.
Resumo:
Attempts to use a stimulated echo acquisition mode (STEAM) in cardiac imaging are impeded by imaging artifacts that result in signal attenuation and nulling of the cardiac tissue. In this work, we present a method to reduce this artifact by acquiring two sets of stimulated echo images with two different demodulations. The resulting two images are combined to recover the signal loss and weighted to compensate for possible deformation-dependent intensity variation. Numerical simulations were used to validate the theory. Also, the proposed correction method was applied to in vivo imaging of normal volunteers (n = 6) and animal models with induced infarction (n = 3). The results show the ability of the method to recover the lost myocardial signal and generate artifact-free black-blood cardiac images.
Resumo:
OBJECTIVES: Lesion detection and characterization in multiple sclerosis (MS) are an essential part of its clinical diagnosis and an important research field. In this pilot study, we applied the recently introduced two inversion-contrast magnetization-prepared rapid gradient echo sequence (MP2RAGE) to patients with early-stage MS.¦MATERIALS AND METHODS: The MP2RAGE is a 3-dimensional (3D) magnetization-prepared rapid gradient echo derivative providing homogeneous T1 weighting and simultaneous T1 mapping. The MP2RAGE performance was compared with that of 2 clinical routine sequences (2D fluid-attenuated inversion recovery [FLAIR] and 3D magnetization-prepared rapid gradient echo [MP-RAGE]) and 2 state-of-the art clinical research sequences (the 3D FLAIR-SPACE [sampling perfection with application-optimized contrasts by using different flip-angle evolutions], a fluid-attenuated variable flip-angle fast spin echo technique, and the 3D double-inversion recovery SPACE). A cohort of 10 early-stage female MS patients (age, 31.6 ± 4.7 years; disease duration, 3.8 ± 1.9 years; median expanded disability status scale score, 1.75) and 10 age- and gender-matched controls were enrolled after approval of the local institutional review board was obtained. Multiple sclerosis lesions were identified and assigned to brain locations and tissue types by two experienced physicians in all 5 contrasts. Subsequently, lesions were manually delineated for comparison and statistical analysis of lesion count, volume and quantitative measures.¦RESULTS AND CONCLUSIONS: The results show that the 3D T1-weighted high-resolution MP2RAGE contrast provides a sensitive means for MS lesion assessment. The additional quantitative T1 relaxation time maps obtained with the MP2RAGE provide further potential diagnostic and prognostic information that could help (a) to better discriminate lesion subtypes and (b) to stage and predict the activity and the evolution of MS. Results also indicate that the T2-weighted double-inversion recovery and FLAIR-SPACE contrasts are attractive complements to the MP2RAGE for lesion detection.
Resumo:
A systematic assessment of global neural network connectivity through direct electrophysiological assays has remained technically infeasible, even in simpler systems like dissociated neuronal cultures. We introduce an improved algorithmic approach based on Transfer Entropy to reconstruct structural connectivity from network activity monitored through calcium imaging. We focus in this study on the inference of excitatory synaptic links. Based on information theory, our method requires no prior assumptions on the statistics of neuronal firing and neuronal connections. The performance of our algorithm is benchmarked on surrogate time series of calcium fluorescence generated by the simulated dynamics of a network with known ground-truth topology. We find that the functional network topology revealed by Transfer Entropy depends qualitatively on the time-dependent dynamic state of the network (bursting or non-bursting). Thus by conditioning with respect to the global mean activity, we improve the performance of our method. This allows us to focus the analysis to specific dynamical regimes of the network in which the inferred functional connectivity is shaped by monosynaptic excitatory connections, rather than by collective synchrony. Our method can discriminate between actual causal influences between neurons and spurious non-causal correlations due to light scattering artifacts, which inherently affect the quality of fluorescence imaging. Compared to other reconstruction strategies such as cross-correlation or Granger Causality methods, our method based on improved Transfer Entropy is remarkably more accurate. In particular, it provides a good estimation of the excitatory network clustering coefficient, allowing for discrimination between weakly and strongly clustered topologies. Finally, we demonstrate the applicability of our method to analyses of real recordings of in vitro disinhibited cortical cultures where we suggest that excitatory connections are characterized by an elevated level of clustering compared to a random graph (although not extreme) and can be markedly non-local.
Resumo:
Microstructure imaging from diffusion magnetic resonance (MR) data represents an invaluable tool to study non-invasively the morphology of tissues and to provide a biological insight into their microstructural organization. In recent years, a variety of biophysical models have been proposed to associate particular patterns observed in the measured signal with specific microstructural properties of the neuronal tissue, such as axon diameter and fiber density. Despite very appealing results showing that the estimated microstructure indices agree very well with histological examinations, existing techniques require computationally very expensive non-linear procedures to fit the models to the data which, in practice, demand the use of powerful computer clusters for large-scale applications. In this work, we present a general framework for Accelerated Microstructure Imaging via Convex Optimization (AMICO) and show how to re-formulate this class of techniques as convenient linear systems which, then, can be efficiently solved using very fast algorithms. We demonstrate this linearization of the fitting problem for two specific models, i.e. ActiveAx and NODDI, providing a very attractive alternative for parameter estimation in those techniques; however, the AMICO framework is general and flexible enough to work also for the wider space of microstructure imaging methods. Results demonstrate that AMICO represents an effective means to accelerate the fit of existing techniques drastically (up to four orders of magnitude faster) while preserving accuracy and precision in the estimated model parameters (correlation above 0.9). We believe that the availability of such ultrafast algorithms will help to accelerate the spread of microstructure imaging to larger cohorts of patients and to study a wider spectrum of neurological disorders.
Resumo:
BACKGROUND: Deep burn assessment made by clinical evaluation has an accuracy varying between 60% and 80% and will determine if a burn injury will need tangential excision and skin grafting or if it will be able to heal spontaneously. Laser Doppler Imaging (LDI) techniques allow an improved burn depth assessment but their use is limited by the time-consuming image acquisition which may take up to 6 min per image. METHODS: To evaluate the effectiveness and reliability of a newly developed full-field LDI technology, 15 consecutive patients presenting with intermediate depth burns were assessed both clinically and by FluxExplorer LDI technology. Comparison between the two methods of assessment was carried out. RESULTS: Image acquisition was done within 6 s. FluxEXPLORER LDI technology achieved a significantly improved accuracy of burn depth assessment compared to the clinical judgement performed by board certified plastic and reconstructive surgeons (P < 0.05, 93% of correctly assessed burns injuries vs. 80% for clinical assessment). CONCLUSION: Technological improvements of LDI technology leading to a decreased image acquisition time and reliable burn depth assessment allow the routine use of such devices in the acute setting of burn care without interfering with the patient's treatment. Rapid and reliable LDI technology may assist clinicians in burn depth assessment and may limit the morbidity of burn patients through a minimization of the area of surgical debridement. Future technological improvements allowing the miniaturization of the device will further ease its clinical application.
Resumo:
The objective of this study was to investigate whether it is possible to pool together diffusion spectrum imaging data from four different scanners, located at three different sites. Two of the scanners had identical configuration whereas two did not. To measure the variability, we extracted three scalar maps (ADC, FA and GFA) from the DSI and utilized a region and a tract-based analysis. Additionally, a phantom study was performed to rule out some potential factors arising from the scanner performance in case some systematic bias occurred in the subject study. This work was split into three experiments: intra-scanner reproducibility, reproducibility with twin-scanner settings and reproducibility with other configurations. Overall for the intra-scanner and twin-scanner experiments, the region-based analysis coefficient of variation (CV) was in a range of 1%-4.2% and below 3% for almost every bundle for the tract-based analysis. The uncinate fasciculus showed the worst reproducibility, especially for FA and GFA values (CV 3.7-6%). For the GFA and FA maps, an ICC value of 0.7 and above is observed in almost all the regions/tracts. Looking at the last experiment, it was found that there is a very high similarity of the outcomes from the two scanners with identical setting. However, this was not the case for the two other imagers. Given the fact that the overall variation in our study is low for the imagers with identical settings, our findings support the feasibility of cross-site pooling of DSI data from identical scanners.
Resumo:
ArF excimer laser pulses (193 nm, 20 ns, 150 mJ) have been focused on a hydroxyapatite (HA) target in similar conditions to those normally used for thin film deposition. Fast intensified CCD images of HA laser ablation plumes have been taken in vacuum and under different water vapor pressures ranging from 0.01 mbar to 1 mbar. Images of HA ablation in vacuum have shown a plume freely expanding at a constant velocity of 2.3 106 cm/s. HA ablation under a water vapor pressure of 0.01 mbar has revealed an expansion behavior very similar to that of ablation in vacuum. Images taken under a water vapor pressure of 0.1 mbar have shown the formation of a shock structure in the plume. Finally, HA ablation under a water vapor pressure of 1 mbar has revealed the development of some irregularities in the shape of the plume.
Resumo:
Time-resolved imaging is carried out to study the dynamics of the laser-induced forward transfer of an aqueous solution at different laser fluences. The transfer mechanisms are elucidated, and directly correlated with the material deposited at the analyzed irradiation conditions. It is found that there exists a fluence range in which regular and well-defined droplets are deposited. In this case, laser pulse energy absorption results in the formation of a plasma, which expansion originates a cavitation bubble in the liquid. After the further expansion and collapse of the bubble, a long and uniform jet is developed, which advances at a constant velocity until it reaches the receptor substrate. On the other hand, for lower fluences no material is deposited. In this case, although a jet can be also generated, it recoils before reaching the substrate. For higher fluences, splashing is observed on the receptor substrate due to the bursting of the cavitation bubble. Finally, a discussion of the possible mechanisms which lead to such singular dynamics is also provided.
Resumo:
Identifying transport pathways in fractured rock is extremely challenging as flow is often organized in a few fractures that occupy a very small portion of the rock volume. We demonstrate that saline tracer experiments combined with single-hole ground penetrating radar (GPR) reflection imaging can be used to monitor saline tracer movement within mm-aperture fractures. A dipole tracer test was performed in a granitic aquifer by injecting a saline solution in a known fracture, while repeatedly acquiring single-hole GPR sections in the pumping borehole located 6 m away. The final depth-migrated difference sections make it possible to identify consistent temporal changes over a 30 m depth interval at locations corresponding to fractures previously imaged in GPR sections acquired under natural flow and tracer-free conditions. The experiment allows determining the dominant flow paths of the injected tracer and the velocity (0.4-0.7 m/min) of the tracer front. Citation: Dorn, C., N. Linde, T. Le Borgne, O. Bour, and L. Baron (2011), Single-hole GPR reflection imaging of solute transport in a granitic aquifer, Geophys. Res. Lett., 38, L08401, doi: 10.1029/2011GL047152.