972 resultados para heavy ion beam
Resumo:
The ALICE Collaboration has measured the inclusive production of muons from heavy-flavor decays at forward rapidity, 2.5 < y < 4, in pp and Pb-Pb collisions at root s(NN) = 2.76 TeV. The p(t)-differential inclusive cross section of muons from heavy-flavor decays in pp collisions is compared to perturbative QCD calculations. The nuclear modification factor is studied as a function of p(t) and collision centrality. A weak suppression is measured in peripheral collisions. In the most central collisions, a suppression of a factor of about 3-4 is observed in 6 < p(t) < 10 GeV/c. The suppression shows no significant p(t) dependence.
Resumo:
There is special interest in the incorporation of metallic nanoparticles in a surrounding dielectric matrix for obtaining composites with desirable characteristics such as for surface plasmon resonance, which can be used in photonics and sensing, and controlled surface electrical conductivity. We investigated nanocomposites produced through metallic ion implantation in insulating substrate, where the implanted metal self-assembles into nanoparticles. During the implantation, the excess of metal atom concentration above the solubility limit leads to nucleation and growth of metal nanoparticles, driven by the temperature and temperature gradients within the implanted sample including the beam-induced thermal characteristics. The nanoparticles nucleate near the maximum of the implantation depth profile (projected range), that can be estimated by computer simulation using the TRIDYN. This is a Monte Carlo simulation program based on the TRIM (Transport and Range of Ions in Matter) code that takes into account compositional changes in the substrate due to two factors: previously implanted dopant atoms, and sputtering of the substrate surface. Our study suggests that the nanoparticles form a bidimentional array buried few nanometers below the substrate surface. More specifically we have studied Au/PMMA (polymethylmethacrylate), Pt/PMMA, Ti/alumina and Au/alumina systems. Transmission electron microscopy of the implanted samples showed the metallic nanoparticles formed in the insulating matrix. The nanocomposites were characterized by measuring the resistivity of the composite layer as function of the dose implanted. These experimental results were compared with a model based on percolation theory, in which electron transport through the composite is explained by conduction through a random resistor network formed by the metallic nanoparticles. Excellent agreement was found between the experimental results and the predictions of the theory. It was possible to conclude, in all cases, that the conductivity process is due only to percolation (when the conducting elements are in geometric contact) and that the contribution from tunneling conduction is negligible.
Resumo:
Recent developments in the theory of plasma-based collisionally excited x-ray lasers (XRL) have shown an optimization potential based on the dependence of the absorption region of the pumping laser on its angle of incidence on the plasma. For the experimental proof of this idea, a number of diagnostic schemes were developed, tested, qualified and applied. A high-resolution imaging system, yielding the keV emission profile perpendicular to the target surface, provided positions of the hottest plasma regions, interesting for the benchmarking of plasma simulation codes. The implementation of a highly efficient spectrometer for the plasma emission made it possible to gain information about the abundance of the ionization states necessary for the laser action in the plasma. The intensity distribution and deflection angle of the pump laser beam could be imaged for single XRL shots, giving access to its refraction process within the plasma. During a European collaboration campaign at the Lund Laser Center, Sweden, the optimization of the pumping laser incidence angle resulted in a reduction of the required pumping energy for a Ni-like Mo XRL, which enabled the operation at a repetition rate of 10 Hz. Using the experiences gained there, the XRL performance at the PHELIX facility, GSI Darmstadt with respect to achievable repetition rate and at wavelengths below 20 nm was significantly improved, and also important information for the development towards multi-100 eV plasma XRLs was acquired. Due to the setup improvements achieved during the work for this thesis, the PHELIX XRL system now has reached a degree of reproducibility and versatility which is sufficient for demanding applications like the XRL spectroscopy of heavy ions. In addition, a European research campaign, aiming towards plasma XRLs approaching the water-window (wavelengths below 5 nm) was initiated.
Resumo:
This work addresses the electronical properties of the superconductors UPd2Al3 and UNi2Al3 on the basis of thin film experiments. These isotructural compounds are ideal candiates to study the interplay of magnetism and superconductivity due to the differences of their magnetically ordered states, as well as the experimental evidence for a magnetic pairing mechanism in UPd2Al3. Epitaxial thin film samples of UPd2Al3 and UNi2Al3 were prepared using UHV Molecular Beam Epitaxy (MBE). For UPd2Al3, the change of the growth direction from the intrinsic (001) to epitaxial (100) was predicted and sucessfully demonstrated using LaAlO3 substrates cut in (110) direction. With optimized deposition process parameters for UPd2Al3 (100) on LaAlO3 (110) superconducting samples with critical temperatures up to Tc = 1.75K were obtained. UPd2Al3-AlOx-Ag mesa junctions with superconducting base electrode were prepared and shown to be in the tunneling regime. However, no signatures of a superconducting density of states were observed in the tunneling spectra. The resistive superconducting transition was probed for a possible dependence on the current direction. In contrast to UNi2Al3, the existence of such feature was excluded in UPd2Al3 (100) thin films. The second focus of this work is the dependence of the resisitive transition in UNi2Al3 (100) thin films on the current direction. The experimental fact that the resisitive transition occurs at slightly higher temperatures for I║a than for I║c can be explained within a model of two weakly coupled superconducting bands. Evidence is presented for the key assumption of the two-band model, namely that transport in and out of the ab-plane is generated on different, weakly coupled parts of the Fermi surface. Main indications are the angle dependence of the superconducting transition and the dependence of the upper critical field Bc2 on current and field orientation. Additionally, several possible alternative explanations for the directional splitting of the transition are excluded in this work. An origin due to scattering on crystal defects or impurities is ruled out, likewise a relation to ohmic heating or vortex dynamics. The shift of the transition temperature as function of the current density was found to behave as predicted by the Ginzburg-Landau theory for critical current depairing, which plays a significant role in the two-band model. In conclusion, the directional splitting of the resisitive transition has to be regarded an intrinsic and unique property of UNi2Al3 up to now. Therefore, UNi2Al3 is proposed as a role model for weakly coupled multiband superconductivity. Magnetoresistance in the normalconducting state was measured for UPd2Al3 and UNi2Al3. For UNi2Al3, a negative contribution was observed close to the antiferromagnetic ordering temperature TN only for I║a, which can be associated to reduced spin-disorder scattering. In agreement with previous results it is concluded that the magnetic moments have to be attributed to the same part of the Fermi surface which generates transport in the ab-plane.
Resumo:
The heavy fermion compound UNi2Al3 exhibits the coexistence of superconductivity and magnetic order at low temperatures, stimulating speculations about possible exotic Cooper-pairing interaction in this superconductor. However, the preparation of good quality bulk single crystals of UNi2Al3 has proven to be a non-trivial task due to metallurgical problems, which result in the formation of an UAl2 impurity phase and hence a strongly reduced sample purity. The present work concentrates on the preparation, characterization and electronic properties investigation of UNi2Al3 single crystalline thin film samples. The preparation of thin films was accomplished in a molecular beam epitaxy (MBE) system. (100)-oriented epitaxial thin films of UNi2Al3 were grown on single crystalline YAlO3 substrates cut in (010)- or (112)-direction. The high crystallographic quality of the samples was proved by several characterisation methods, such as X-ray analysis, RHEED and TEM. To study the magnetic structure of epitaxial thin films resonant magnetic x-ray scattering was employed. The magnetic order of thin the film samples, the formation of magnetic domains with different moment directions, and the magnetic correlation length were discussed. The electronic properties of the UNi2Al3 thin films in the normal and superconducting states were investigated by means of transport measurements. A pronounced anisotropy of the temperature dependent resistivity ρ(T) was observed. Moreover, it was found that the temperature of the resistive superconducting transition depends on the current direction, providing evidence for multiband superconductivity in UNi2Al3. The initial slope of the upper critical field H′c2(T) of the thin film samples suggests an unconventional spin-singlet superconducting state, as opposed to bulk single crystal data. To probe the superconducting gap of UNi2Al3 directly by means of tunnelling spectroscopy many planar junctions of different design employing different techniques were prepared. Despite the tunneling regime of the junctions, no features of the superconducting density of state of UNi2Al3 were ever observed. It is assumed that the absence of UNi2Al3 gap features in the tunneling spectra was caused by imperfections of the tunnelling contacts. The superconductivity of UNi2Al3 was probably suppressed just in a degraded surface layer, resulting in tunneling into non superconducting UNi2Al3. However, alternative explanations such as intrinsic pair breaking effects at the interface to the barrier are also possible.
Resumo:
Das Penningfallen-Massenspektrometer SHIPTRAP wurde gebaut um HochprÄazi-rnsionsmassenmessungen an schweren Radionukliden durchzufÄuhren, die in Fusions-rnreaktionen produziert und vom Geschwindigkeitsfilter SHIP vom Primärstrahl sepa-rnriert werden. Es besteht aus einer Gaszelle zur Abbremsung der hochenergetis-rnchen Reaktionsprodukte, einem RFQ-Kühler und Buncher zur Kühlung und Akku-rnmulation der Ionen und einem Doppel-Penningfallen-System um Massenmessungenrndurchzuführen. Die Masse wird durch die Messungen der Zyklotronfrequenz desrnentsprechenden Ions in einem starken homogenen Magnetfeld bestimmt. Diese Fre-rnquenz wird mit der Frequenz eines wohlbekannten Referenzions verglichen. Mitrndieser Methode können relative Fehler in der Größenordnung von 10^-8 erreicht werden. Kürzlich konnten die Massen der Nobeliumisotope 252-254No (Z=102) und desrnLawrenciumisotops 255Lr (Z=103) erstmals erfolgreich gemessen werden. Dies warenrndie ersten direkten Massenmessungen an Transuranen. Die Produktionrate dieserrnAtome lag bei etwa eins pro Sekunde und weniger. Die Ergebnisse der Massenmes-rnsungen an Nobelium bestätigen die früheren Massenwerte, die aus Q_alpha-Messungenrnabgeleitet wurden. Im Fall von 255Lr wurde der Massenexzess, der bis dahin nur ausrnsystematischen Trends abgeschätzt wurde, zum ersten Mal direkt bestimmt. DiesernErgebnisse sind ein erster Schritt für die an SHIPTRAP geplante Erforschung derrnRegion der Transurane. Das Hauptziel ist hierbei die Bestimmung der Endpunkternder alpha-Zerfallsketten, die in superschweren Elementen in der Nähe der vorhergesagtenrnStabilitätsinsel ihren Ursprung nehmen.
Resumo:
This work investigates the influence of chemical reactions on the release of elements from target-ion source units for ISOL facilities. Methods employed are thermochromatography, yield and hold-up time measurements; adsorption enthalpies have been determined for Ag and In. The results obtained with these methods are consistent. Elements exhibit reversible or irreversible reactions on different surfaces (Tantalum, quartz, sapphire). The interactions with surfaces inside the target-ion source unit can be used to improve the quality of radioactive ion beams. Spectroscopic data obtained at CERN-ISOLDE using a medium-temperature quartz transfer line show the effectivity of selective adsorption for beam purification. New gamma lines of 131Cd have been observed and a tentative decay scheme is presented.
Resumo:
In dieser Arbeit werden der experimentelle Aufbau und erste Messungen für die Bestimmung des g-Faktors des Elektrons gebunden in wasserstoff- und lithiumähnlichen mittelschweren Ionen beschrieben. Mit dem hochpräzisenWert des g-Faktors können theoretische Berechnungen der Quantenelektrodynamik gebundener Zustände überprüft werden. Die Messungen werden in einem Dreifach-Penningfallen-System durchgeführt. Dort wurden im Rahmen dieser Arbeit auch erstmals hochgeladene Ionen bis 28Si13+ in einer hierfür entwickelten Elektronenstrahl-Ionenquelle/-falle erzeugt. Für die Bestimmung des g-Faktors werden die freie Zyklotronfrequenz und die Larmorfrequenz benötigt. Erstere wird aus den drei Eigenfrequenzen des in der Präzisionsfalle gespeicherten Ions berechnet. Um das Ion bei den Messungen nicht zu verlieren, werden die Eigenfrequenzen des Ions durch Kopplung an einen radiofrequenten Nachweisschwingkreis nicht-destruktiv nachgewiesen. Die freie Zyklotronfrequenz konnte dabei mit einer relativen Genauigkeit von wenigen 10E−9 bestimmt werden. Zur Bestimmung der Larmorfrequenz ist die genaue Kenntnis der Spinrichtung des Elektrons im Magnetfeld notwendig. Diese wird durch den kontinuierlichen Stern-Gerlach-Effekt in der sogenannten Analysefalle bestimmt. Hierzu muss eine hohe Stabilität der axialen Frequenz des Ions erreicht werden. Um dies sowie die Hochpräzisionsmessungen in der Präzisionsfalle zu erreichen, wurden in dieser Arbeit beide Fallen hinsichtlich ihrer elektrischen und magnetischen Eigenschaften charakterisiert.
Resumo:
Ion traps have been established as a powerful tool for ion cooling and laser spectroscopy experiments since a long time ago. SpecTrap, one of the precision experiments associated to the HITRAP facility at GSI, is implementing a Penning trap for studies of large bunches of externally produced highly charged ions. The extremely strong electric and magnetic fields that exist around the nuclei of heavy elements drastically change their electronic properties, such as energy level spacings and radiative lifetimes. The electrons can therefore serve as sensitive probes for nuclear properties such as size, magnetic moment and spatial distribution of charge and magnetization. The energies of forbidden fine and hyperfine structure transitions in such ions strongly depend on the nuclear charge and shift from the microwave domain into the optical domain. Thus, they become accessible for laser spectroscopy and its potentially high accuracy. A number of such measurements has been performed in storage rings and electron beam ion traps and yielded results with relative accuracies in the 10
Resumo:
For more than 4 years, gaseous samples of 1-50 mu g carbon have been routinely measured with the gas ion source of the small AMS (Accelerator Mass Spectrometer) facility MICADAS (Mini CArbon DAting System) at ETH Zurich. The applied measurement technique offers a simple and fast way of C-14 measurements without the need of sample graphitization. A major drawback of gaseous C-14 measurements, however, is the relatively low negative ion current, which results in longer measurement times and lower precision compared to graphitized samples. In December 2009, a new, improved Cs sputter ion source was installed at MICADAS and we began to optimize conditions for the measurement of gaseous samples. C-12(-) currents from the new ion source were improved from initially 3 to 12-15 mu A for routine measurements and the negative ion yield was increased by a factor of 2, reaching 8 on average during routine operation. Moreover, the new measurement settings enable a doubled CO2 flow, thus substantially reducing measurement times. The achieved performance allows closing the sample size gap between gaseous and solid samples and makes the gas ion source a promising tool for dating with a measurement precision of 5 parts per thousand on samples as small as 50 mu g carbon. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
In 2010 more than 600 radiocarbon samples were measured with the gas ion source at the MIni CArbon DAting System (MICADAS) at ETH Zurich and the number of measurements is rising quickly. While most samples contain less than 50 mu g C at present, the gas ion source is attractive as well for larger samples because the time-consuming graphitization is omitted. Additionally, modern samples are now measured down to 5 per-mill counting statistics in less than 30 min with the recently improved gas ion source. In the versatile gas handling system, a stepping-motor-driven syringe presses a mixture of helium and sample CO2 into the gas ion source, allowing continuous and stable measurements of different kinds of samples. CO2 can be provided in four different ways to the versatile gas interface. As a primary method. CO2 is delivered in glass or quartz ampoules. In this case, the CO2 is released in an automated ampoule cracker with 8 positions for individual samples. Secondly, OX-1 and blank gas in helium can be provided to the syringe by directly connecting gas bottles to the gas interface at the stage of the cracker. Thirdly, solid samples can be combusted in an elemental analyzer or in a thermo-optical OC/EC aerosol analyzer where the produced CO2 is transferred to the syringe via a zeolite trap for gas concentration. As a fourth method, CO2 is released from carbonates with phosphoric acid in septum-sealed vials and loaded onto the same trap used for the elemental analyzer. All four methods allow complete automation of the measurement, even though minor user input is presently still required. Details on the setup, versatility and applications of the gas handling system are given. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Mass spectrometric analysis of elemental and isotopic compositions of several NIST standards is performed by a miniature laser ablation/ionisation reflectron-type time-of-flight mass spectrometer (LMS) using a fs-laser ablation ion source (775 nm, 190 fs, 1 kHz). The results of the mass spectrometric studies indicate that in a defined range of laser irradiance (fluence) and for a certain number of accumulations of single laser shot spectra, the measurements of isotope abundances can be conducted with a measurement accuracy at the per mill level and at the per cent level for isotope concentrations higher and lower than 100 ppm, respectively. Also the elemental analysis can be performed with a good accuracy. The LMS instrument combined with a fs-laser ablation ion source exhibits similar detection efficiency for both metallic and non-metallic elements. Relative sensitivity coefficients were determined and found to be close to one, which is of considerable importance for the development of standard-less instruments. Negligible thermal effects, sample damage and excellent characteristics of the fs-laser beam are thought to be the main reason for substantial improvement of the instrumental performance compared to other laser ablation mass spectrometers.