909 resultados para comparison methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Polymerase chain reaction (PCR) may offer an alternative diagnostic option when clinical signs and symptoms suggest visceral leishmaniasis (VL) but microscopic scanning and serological tests provide negative results. PCR using urine is sensitive enough to diagnose human visceral leishmaniasis (VL). However, DNA quality is a crucial factor for successful amplification. Methods A comparative performance evaluation of DNA extraction methods from the urine of patients with VL using two commercially available extraction kits and two phenol-chloroform protocols was conducted to determine which method produces the highest quality DNA suitable for PCR amplification, as well as the most sensitive, fast and inexpensive method. All commercially available kits were able to shorten the duration of DNA extraction. Results With regard to detection limits, both phenol: chloroform extraction and the QIAamp DNA Mini Kit provided good results (0.1 pg of DNA) for the extraction of DNA from a parasite smaller than Leishmania (Leishmania) infantum (< 100fg of DNA). However, among 11 urine samples from subjects with VL, better performance was achieved with the phenol:chloroform method (8/11) relative to the QIAamp DNA Mini Kit (4/11), with a greater number of positive samples detected at a lower cost using PCR. Conclusion Our results demonstrate that phenol:chloroform with an ethanol precipitation prior to extraction is the most efficient method in terms of yield and cost, using urine as a non-invasive source of DNA and providing an alternative diagnostic method at a low cost.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Various methods are used for the diagnosis of visceral leishmaniasis (VL), such as microscopic examination, culture and inoculation of laboratory animals; however, serological assays are commonly used for the detection of antibodies in serum samples with a wide range of specificity and sensitivity. METHODS: The purpose of this study was to compare three serological methods, including rA2-ELISA, the recombinant KE16 (rKE16) dipstick test and the direct agglutination test (DAT), for the detection of antibodies against VL antigens. The assays utilized 350 statistically based random serum samples from domestic dogs with clinical symptoms as well as samples from asymptomatic and healthy dogs from rural and urban areas of the Meshkinshahr district, northwestern Iran. RESULTS: Samples were assessed, and the following positive rates were obtained: 11.5% by rKE16, 26.9% by DAT and 49.8% by ELISA. The sensitivity among symptomatic dogs was 32.4% with rKE16, 100% with DAT and 52.9% with ELISA. Conversely, rA2-ELISA was less specific for asymptomatic dogs, at 46.5%, compared with DAT, at 88.9%. CONCLUSIONS : This study recommends rA2-ELISA as a parallel assay combined with DAT to detect VL infection among dogs. Further evaluations should be performed to develop an inexpensive and reliable serologic test for the detection of Leishmania infantum among infected dogs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE: To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS: Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS: The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION: There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients with unilateral cleft lip display characteristic nasal changes that are independent of the degree of deformity. Defenders of the intrinsic theory consider these deformities to be due to embryogenic alterations of the alar nasal cartilages. Those that propose the extrinsic theory defend the thesis that the deformity is due to disorganization of the perioral muscles deformed by the cleft. The purpose of this study is to contribute histological evidence to help clarify the issue. PATIENTS AND METHODS: Specimens of the lateral portion of both the healthy and the cleft side of the alar cartilages were obtained from 18 patients. These uniformly cut specimens were stained by hematoxylin and eosin. Samples from 2 patients were excluded due to imperfections. The same pathologist examined all the slides. He was unaware of the origins of the specimens; he counted the number of chondrocytes and quantified the cartilage matrixes. RESULTS: All data was analyzed statistically, and no significant statistical differences were apparent, either in the number of chondrocytes or the cartilage matrix between the healthy side and the cleft side. DISCUSSION: These results apparently support the group that defend the extrinsic theory; nevertheless, the doubt about the composition of the cartilage matrix remains, not only concerning the glycosaminoglycans that compose them, but also regarding elastin and collagen and its linkages that can cause different degrees of collagen consistency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Infection is the leading complication of long-term central venous catheters, and its incidence may vary according to catheter type. The objective of this study was to compare the frequency and probability of infection between two types of long-term intravenous devices. METHODS: Retrospective study in 96 onco-hematology patients with partially implanted catheters (n = 55) or completely implanted ones (n = 42). Demographic data and catheter care were similar in both groups. Infection incidence and infection-free survival were used for the comparison of the two devices. RESULTS: In a median follow-up time of 210 days, the catheter-related infection incidence was 0.2102/100 catheter-days for the partially implanted devices and 0.0045/100 catheter-days for the completely implanted devices; the infection incidence rate was 46.7 (CI 95% = 6.2 to 348.8). The 1-year first infection-free survival ratio was 45% versus 97%, and the 1-year removal due to infection-free survival ratio was 42% versus 97% for partially and totally implanted catheters, respectively (P <.001 for both comparisons). CONCLUSION: In the present study, the infection risk was lower in completely implanted devices than in partially implanted ones.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the last decade of the twentieth century, the healthcare industry is paying attention to the environmental impact of their buildings and therefore new regulations, policy goals and Buildings Sustainability Assessment (HBSA) methods are being developed and implemented. At the present, healthcare is one of the most regulated industries and it is also one of the largest consumers of energy per net floor area. To assess the sustainability of healthcare buildings it is necessary to establish a set of benchmarks related with their life-cycle performance. They are both essential to rate the sustainability of a project and to support designers and other stakeholders in the process of designing and operating a sustainable building, by allowing the comparison to be made between a project and the conventional and best market practices. This research is focused on the methodology to set the benchmarks for resources consumption, waste production, operation costs and potential environmental impacts related to the operational phase of healthcare buildings. It aims at contributing to the reduction of the subjectivity found in the definition of the benchmarks used in Building Sustainability Assessment (BSA) methods, and it is applied in the Portuguese context. These benchmarks will be used in the development of a Portuguese HBSA method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As a renewable energy source, the use of forest biomass for electricity generation is advantageous in comparison with fossil fuels, however the activity of forest biomass power plants causes adverse impacts, affecting particularly neighbouring communities. The main objective of this study is to estimate the effects of the activity of forest biomass power plants on the welfare of two groups of stakeholders, namely local residents and the general population and we apply two stated preference methods: contingent valuation and discrete choice experiments, respectively. The former method was applied to estimate the minimum compensation residents of neighbouring communities of two forest biomass power plants in Portugal would be willing to accept. The latter method was applied among the general population to estimate their willingness to pay to avoid specific environmental impacts. The results show that the presence of the selected facilities affects individuals’ well-being. On the other hand, in the discrete choice experiments conducted among the general population all impacts considered were significant determinants of respondents’ welfare levels. The results of this study stress the importance of performing an equity analysis of the welfare effects on different groups of stakeholders from the installation of forest biomass power plants, as their effects on welfare are location and impact specific. Policy makers should take into account the views of all stakeholders either directly or indirectly involved when deciding crucial issues regarding the sitting of new forest biomass power plants, in order to achieve an efficient and equitable outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traffic Engineering (TE) approaches are increasingly impor- tant in network management to allow an optimized configuration and resource allocation. In link-state routing, the task of setting appropriate weights to the links is both an important and a challenging optimization task. A number of different approaches has been put forward towards this aim, including the successful use of Evolutionary Algorithms (EAs). In this context, this work addresses the evaluation of three distinct EAs, a single and two multi-objective EAs, in two tasks related to weight setting optimization towards optimal intra-domain routing, knowing the network topology and aggregated traffic demands and seeking to mini- mize network congestion. In both tasks, the optimization considers sce- narios where there is a dynamic alteration in the state of the system, in the first considering changes in the traffic demand matrices and in the latter considering the possibility of link failures. The methods will, thus, need to simultaneously optimize for both conditions, the normal and the altered one, following a preventive TE approach towards robust configurations. Since this can be formulated as a bi-objective function, the use of multi-objective EAs, such as SPEA2 and NSGA-II, came nat- urally, being those compared to a single-objective EA. The results show a remarkable behavior of NSGA-II in all proposed tasks scaling well for harder instances, and thus presenting itself as the most promising option for TE in these scenarios.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Methods: Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-pointtouch fitting approach. The lens’ back optic zone radius (BOZR) was 0.4 mm and 0.1 mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. Results: A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p < 0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p < 0.05). Significant reduction was found over time in CCA (p = 0.001) and anterior corneal asphericity in both groups (p < 0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p < 0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p < 0.05). Conclusion: Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apicaltouch was associated with greater corneal flattening in comparison to three-point-touch lens wear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The study presents the Brazilian norms for 240 new stimuli from International Affective Picture System (IAPS), a database of affective images widely used in research, compared to the North-American normative ratings. METHODS: The participants were 448 Brazilian university students from several courses (269 women and 179 men) with mean age of 24.2 (SD = 7.8), that evaluated the IAPS pictures in the valence, arousal and dominance dimensions by the Self-Assessment Manikin (SAM) scales. Data were compared across the populations by Pearson linear correlation and Student's t-tests. RESULTS: Correlations were highly significant for all dimensions; however, Brazilians' averages for arousal were higher than North-Americans'. CONCLUSIONS: The results show stability in relation to the first part of the Brazilian standardization and they are also consistent with the North-American standards, despite minor differences relating to interpretation of the arousal dimension, demonstrating that IAPS is a reliable instrument for experimental studies in the Brazilian population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To develop a stereological comparison between right (RV) and left ventricle (LV) myocardium during the third human gestational trimester. METHODS: Five human fetal hearts of the third trimester provided representative samples of 5 RV myocardium and 4 LV myocardium. The material was fixed in 10% buffered formaldehyde, and processed through routine methods. Fifteen microscopic fields were randomly chosen and counted in each ventricular myocardium using an "M-42" test system. The following stereological parameters were assessed: Vv (%), Lv (µm²), Sv (µm²/µm³), Vp (µm³), Nv (1/mm³) and total N. RESULTS: No significant difference between the stereological parameters of the myocardial structures assessed was evidenced, when comparing RV and LV. CONCLUSION: Right and left human ventricular myocardium are very similar during the fetal period at least in regard to their structural aspects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess safety and efficacy of coronary angioplasty with stent implantation in unstable coronary syndromes. METHODS: Retrospective analysis of in-hospital and late evolution of 74 patients with unstable coronary syndromes (unstable angina or infarction without elevation of the ST segment) undergoing coronary angioplasty with stent placement. These 74 patients were compared with 31 patients with stable coronary syndromes (stable angina or stable silent ischemia) undergoing the same procedure. RESULTS: No death and no need for revascularization of the culprit artery occurred in the in-hospital phase. The incidences of acute non-Q-wave myocardial infarction were 1.4% and 3.2% (p=0.6) in the unstable and stable coronary syndrome groups, respectively. In the late follow-up (11.2±7.5 months), the incidences of these events combined were 5.7% in the unstable coronary syndrome group and 6.9% (p=0.8) in the stable coronary syndrome group. In the multivariate analysis, the only variable with a tendency to significance as an event predictor was diabetes mellitus (p=0.07; OR=5.2; 95% CI=0.9-29.9). CONCLUSION: The in-hospital and late evolutions of patients with unstable coronary syndrome undergoing angioplasty with intracoronary stent implantation are similar to those of the stable coronary syndrome group, suggesting that this procedure is safe and efficacious when performed in unstable coronary syndrome patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Our aim was to compare, in a non randomized study, the surgical outcome in elderly patients with mechanical (Group 1; n=83) and bioprosthetic valve implants (Group 2; n=136). METHODS: During a three year period, 219 patients >75 years underwent Aortic Valve Replacement. The groups matched according to age, sex, comorbidity, valve pathology and concomitant Coronary Artery Bypass Surgery. Follow-up was a total of 469 patient-years (mean follow-up 2.1 years, maximum 4,4 years). RESULTS: Operative mortality was zero and the overall early mortality was 2.3 % (within 30 days). Actuarial survival was 87.5 ± 4.0% and 66.1 ± 7.7% (NS) at 4 years in Group 1 and Group 2, respectively. Freedom from valve-related death was 88.9 ± 3.8% in Group 1 and 69.9±7.9% (NS) in Group 2 at 4 years. CONCLUSION: Aortic Valve Replacement in the elderly (>75 years) is a safe procedure even in cases where concomitant coronary artery revascularization is performed. Only a few anticoagulant-related complications were reported and this may indicate that selected groups of elderly patients with significant life expectancy may benefit from mechanical implants .

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To verify the possible role of adventitial inflammation in atherosclerotic plaque vulnerability and coronary artery remodelling. METHODS: We compared the mean numbers of lymphocytes in the adventitia and in the plaque of ruptured thrombosed and stable equi-stenotic coronary segments of 34 patients who died due to acute myocardial infarction. We also analysed adventitial microvessels, adventitial fibrosis and the external elastic membrane. RESULTS: In the adventitia, the numbers of lymphocytes and microvessels/mm² were 69.5±88.3 and 60.9± 32.1 in culprit lesions and 16.4 ± 21.1 and 44.3±16.1 in stable lesions (p<0.05); within the plaques, the mean number of lymphocytes was 24±40.8 in culprit lesions and 10.9±13.2 in stable ones (p=0.17). The mean percent area of adventitial fibrosis/cross-sectional area of the vessel was significantly lower in unstable plaques (p<0.001). The confocal images showed holes in the external elastic membrane. CONCLUSION: Unstable plaques exhibit chronic pan-arteritis, accompanied by enlargement, medial thinning, and less fibrosis than in stable lesions, which is compatible with vessel aneurysm. Adventitial inflammation may contribute significantly to atheroma instability.