526 resultados para centrifugal compressor
Resumo:
In refrigeration systems a small amount of compressor lubricant is entrained in the refrigerant and circulated through the system, where some is retained in each component. The suction line to the compressor has the largest potential for oil retention. This paper presents results from an experimental apparatus that has been constructed to circulate POE (polyolester) oil and R410A at a controlled mass flux, OCR (oil in circulation ratio), and apparent superheat, and to directly measure the pressure drop and mass of oil retained in horizontal and vertical suction lines. The bulk vapor velocity and overall void fraction are determined from direct mass and temperature measurements. The oil retention, pressure drop, and flow regimes near the minimum ASHRAE recommended mass flux condition are explored. It was found that oil retention begins to increase sharply even above the minimum recommended flux, so conditions near the minimum should be avoided. Two relationships were developed to predict the oil retention in the vertical and horizontal suction lines. The average error from the predictions method was 10.9% for the vertical tube, and 7.9% for the horizontal tube.
Resumo:
Tässä työssä on tutkittu prosessipuhaltimena käytettävän keskipakoispuhaltimen lujuusteknistä mitoitusta. Työn tavoitteena on ollut luoda analyyttisiä laskentakaavoja Koja Oy:n käyttöön tulevaisuuden tuotekehityksen tueksi. Tavoitteena on ollut tutkia myös siipien ja etu- ja takalevyn kiinnityshitsejä ja antaa työkaluja siipipyörän väsymismitoitukseen. Kirjallisuuskatkauksessa löytyi muutamia raportoituja tapauksia, jossa keskipakoispuhallin on vaurioitunut käytön aikana. Yhtenäisenä tekijänä kaikille tapauksille on ollut hitsausliitoksen väsyminen. Väsyttävän kuormituksen raportoiduissa tapauksissa on aiheuttanut siipipyörän värähtely. Väsyminen on alkanut siiven kiinnitysliitoksista hitsin rajaviivalta, siipipyörän ulkokehältä. Siipipyörän analysointiin on käytetty analyyttisiä laskentakaavoja ja elementtimenetelmää. Analyyttisten laskentakaavojen tuottaminen on muuten monimutkaiselle rakenteelle hyvin työlästä ja aikaa vievää. Staattisessa tarkastelussa elementtimenetelmällä siipipyörän mallintamiseen on käytetty keskipintamallia. Lisäksi laskentatiedostojen kokoa on pystytty rajaamaan syklisesti symmetrisen rakenteen ansiosta. Siipipyörän väsymistarkastelu on suoritettu tehollisen lovijännityksen menetelmällä, jossa tarkasteltavan hitsin rajaviivoille ja juureen on elementtimenetelmässä mallinnettu r=1 mm suuruinen lovi, josta jännityksen on luettu. Elementtimenetelmässä laskentaohjelmistona on käytetty Abaqus 6.14.1 -laskentaohjelmistoa. Analyyttisten laskentakaavojen kehityksessä on päästy hyvin lähelle elementtimenetelmästä saatuja vastaavia tuloksia. Analyyttisten kaavojen antamat tulokset eroavat kuitenkin sen verran virhettä, että varsinainen tarkka laskenta on syytä suorittaa ennen lopullisen konstruktion määrittämistä. Tehollisella lovijännitysmenetelmällä on saatu määritettyä rakenteen kriittisin kohta, jonka kestoikä on 36 400 sykliä. Tutkimuksen pohjalta Koja Oy on saanut hyvät edellytykset jatkaa tutkimusta lopun tuoteperheen parantamiseen.
Resumo:
Due to trends in aero-design, aeroelasticity becomes increasingly important in modern turbomachines. Design requirements of turbomachines lead to the development of high aspect ratio blades and blade integral disc designs (blisks), which are especially prone to complex modes of vibration. Therefore, experimental investigations yielding high quality data are required for improving the understanding of aeroelastic effects in turbomachines. One possibility to achieve high quality data is to excite and measure blade vibrations in turbomachines. The major requirement for blade excitation and blade vibration measurements is to minimize interference with the aeroelastic effects to be investigated. Thus in this paper, a non-contact-and thus low interference-experimental set-up for exciting and measuring blade vibrations is proposed and shown to work. A novel acoustic system excites rotor blade vibrations, which are measured with an optical tip-timing system. By performing measurements in an axial compressor, the potential of the acoustic excitation method for investigating aeroelastic effects is explored. The basic principle of this method is described and proven through the analysis of blade responses at different acoustic excitation frequencies and at different rotational speeds. To verify the accuracy of the tip-timing system, amplitudes measured by tip-timing are compared with strain gage measurements. They are found to agree well. Two approaches to vary the nodal diameter (ND) of the excited vibration mode by controlling the acoustic excitation are presented. By combining the different excitable acoustic modes with a phase-lag control, each ND of the investigated 30 blade rotor can be excited individually. This feature of the present acoustic excitation system is of great benefit to aeroelastic investigations and represents one of the main advantages over other excitation methods proposed in the past. In future studies, the acoustic excitation method will be used to investigate aeroelastic effects in high-speed turbomachines in detail. The results of these investigations are to be used to improve the aeroelastic design of modern turbomachines.
Resumo:
The off-cycle refrigerant mass migration has a direct influence on the on-cycle performance since compressor energy is necessary to redistribute the refrigerant mass. No studies, as of today, are available in the open literature which experimentally measured the lubricant migration within a refrigeration system during cycling or stop/start transients. Therefore, experimental procedures measuring the refrigerant and lubricant migration through the major components of a refrigeration system during stop/start transients were developed and implemented. Results identifying the underlying physics are presented. The refrigerant and lubricant migration of an R134a automotive A/C system-utilizing a fixed orifice tube, minichannel condenser, plate and fin evaporator, U-tube type accumulator and fixed displacement compressor-was measured across five sections divided by ball valves. Using the Quick-Closing Valve Technique (QCVT) combined with the Remove and Weigh Technique (RWT) using liquid nitrogen as the condensing agent resulted in a measurement uncertainty of 0.4 percent regarding the total refrigerant mass in the system. The determination of the lubricant mass distribution was achieved by employing three different techniques-Remove and Weigh, Mix and Sample, and Flushing. To employ the Mix and Sample Technique a device-called the Mix and Sample Device-was built. A method to separate the refrigerant and lubricant was developed with an accuracy-after separation-of 0.04 grams of refrigerant left in the lubricant. When applying the three techniques, the total amount of lubricant mass in the system was determined to within two percent. The combination of measurement results-infrared photography and high speed and real time videography-provide unprecedented insight into the mechanisms of refrigerant and lubricant migration during stop-start operation. During the compressor stop period, the primary refrigerant mass migration is caused by, and follows, the diminishing pressure difference across the expansion device. The secondary refrigerant migration is caused by a pressure gradient as a result of thermal nonequilibrium within the system and causes only vapor phase refrigerant migration. Lubricant migration is proportional to the refrigerant mass during the primary refrigerant mass migration. During the secondary refrigerant mass migration lubricant is not migrating. The start-up refrigerant mass migration is caused by an imbalance of the refrigerant mass flow rates across the compressor and expansion device. The higher compressor refrigerant mass flow rate was a result of the entrainment of foam into the U-tube of the accumulator. The lubricant mass migration during the start-up was not proportional to the refrigerant mass migration. The presence of water condensate on the evaporator affected the refrigerant mass migration during the compressor stop period. Caused by an evaporative cooling effect the evaporator held 56 percent of the total refrigerant mass in the system after three minutes of compressor stop time-compared to 25 percent when no water condensate was present on the evaporator coil. Foam entrainment led to a faster lubricant and refrigerant mass migration out of the accumulator than liquid entrainment through the hole at the bottom of the U-tube. The latter was observed for when water condensate was present on the evaporator coil because-as a result of the higher amount of refrigerant mass in the evaporator before start-up-the entrainment of foam into the U-tube of the accumulator ceased before the steady state refrigerant mass distribution was reached.
Resumo:
Electrical Submersible Pump (ESP) is used as an artificial lift technique. However, pumping viscous oil is generally associated with low Reynolds number flows. This condition leads to a performance degradation respect to the performance expected from the regular operation with water that most of the centrifugal pumps are originally designed for. These issues are considered in this investigation through a numerical study of the flow in two different multistage, semi-axial type ESPs. This investigation is carried out numerically using a Computational Fluid Dynamics (CFD) package, where the transient RANS equations are solved numerically. The turbulence is modeled using the SST model. Head curves for several operating conditions are compared with manufacturer’s curves and experimental data for a three-stage ESP, showing good agreement for a wide range of fluid viscosities and rotational speeds. Dimensionless numbers (n, n, n e Re) are used to investigate performance degradation of the ESPs. In addition, flow phenomena through the impellers of the ESPs are investigated using flow field from numerical results. Results show that performance degradation is directly related to rotational Reynolds number, Re. In addition, it was verified that performance degradation occurs for constant normalized specific speedn, which shows that performance degradation occurs similarly for different centrifugal pumps. Moreover, experimental data and numerical results agreed with a correlation from literature between head and flow correction factors proposed by Stepanoff (1967). A definition of modified Reynolds number was proposed and relates the head correction factor to viscosity. A correlation between head correction factor and the modified Reynolds number was proposed, which agreed well with numerical and experimental data. Then, a method to predict performance degradation based on the previous correlations was proposed. This method was compared with others from literature. In general, results and conclusions from this work can also be useful to bring more information about the flow of highly viscous fluids in pumps, especially in semi-axial, multistage ESPs.
Resumo:
The share of variable renewable energy in electricity generation has seen exponential growth during the recent decades, and due to the heightened pursuit of environmental targets, the trend is to continue with increased pace. The two most important resources, wind and insolation both bear the burden of intermittency, creating a need for regulation and posing a threat to grid stability. One possibility to deal with the imbalance between demand and generation is to store electricity temporarily, which was addressed in this thesis by implementing a dynamic model of adiabatic compressed air energy storage (CAES) with Apros dynamic simulation software. Based on literature review, the existing models due to their simplifications were found insufficient for studying transient situations, and despite of its importance, the investigation of part load operation has not yet been possible with satisfactory precision. As a key result of the thesis, the cycle efficiency at design point was simulated to be 58.7%, which correlated well with literature information, and was validated through analytical calculations. The performance at part load was validated against models shown in literature, showing good correlation. By introducing wind resource and electricity demand data to the model, grid operation of CAES was studied. In order to enable the dynamic operation, start-up and shutdown sequences were approximated in dynamic environment, as far as is known, the first time, and a user component for compressor variable guide vanes (VGV) was implemented. Even in the current state, the modularly designed model offers a framework for numerous studies. The validity of the model is limited by the accuracy of VGV correlations at part load, and in addition the implementation of heat losses to the thermal energy storage is necessary to enable longer simulations. More extended use of forecasts is one of the important targets of development, if the system operation is to be optimised in future.
Resumo:
Centrifugal pumps are vastly used in many industrial applications. Knowledge of how these components behave in several circumstances is crucial for the development of more efficient and, therefore, less expensive pumping installations. The combination of multiple impellers, vaned diffusers and a volute might introduce several complex flow characteristics that largely deviate from regular inviscid pump flow theory. Computational Fluid Dynamics can be very helpful to extract information about which physical phenomena are involved in such flows. In this sense, this work performs a numerical study of the flow in a two-stage centrifugal pump (Imbil ITAP 65-330/2) with a vaned diffuser and a volute. The flow in the pump is modeled using the software Ansys CFX, by means of a multi-block, transient rotor-stator technique, with structured grids for all pump parts. The simulations were performed using water and a mixture of water and glycerin as work fluids. Several viscosities were considered, in a range between 87 and 720 cP. Comparisons between experimental data obtained by Amaral (2007) and numerical head curves showed a good agreement, with an average deviation of 6.8% for water. The behavior of velocity, pressure and turbulence kinetic energy fields was evaluated for several operational conditions. In general, the results obtained by this work achieved the proposed goals and are a significant contribution to the understanding of the flow studied.
Resumo:
This thesis describes two separate projects. The first is a theoretical and experimental investigation of surface acoustic wave streaming in microfluidics. The second is the development of a novel acoustic glucose sensor. A separate abstract is given for each here. Optimization of acoustic streaming in microfluidic channels by SAWs Surface Acoustic Waves, (SAWs) actuated on flat piezoelectric substrates constitute a convenient and versatile tool for microfluidic manipulation due to the easy and versatile interfacing with microfluidic droplets and channels. The acoustic streaming effect can be exploited to drive fast streaming and pumping of fluids in microchannels and droplets (Shilton et al. 2014; Schmid et al. 2011), as well as size dependant sorting of particles in centrifugal flows and vortices (Franke et al. 2009; Rogers et al. 2010). Although the theory describing acoustic streaming by SAWs is well understood, very little attention has been paid to the optimisation of SAW streaming by the correct selection of frequency. In this thesis a finite element simulation of the fluid streaming in a microfluidic chamber due to a SAW beam was constructed and verified against micro-PIV measurements of the fluid flow in a fabricated device. It was found that there is an optimum frequency that generates the fastest streaming dependent on the height and width of the chamber. It is hoped this will serve as a design tool for those who want to optimally match SAW frequency with a particular microfluidic design. An acoustic glucose sensor Diabetes mellitus is a disease characterised by an inability to properly regulate blood glucose levels. In order to keep glucose levels under control some diabetics require regular injections of insulin. Continuous monitoring of glucose has been demonstrated to improve the management of diabetes (Zick et al. 2007; Heinemann & DeVries 2014), however there is a low patient uptake of continuous glucose monitoring systems due to the invasive nature of the current technology (Ramchandani et al. 2011). In this thesis a novel way of monitoring glucose levels is proposed which would use ultrasonic waves to ‘read’ a subcutaneous glucose sensitive-implant, which is only minimally invasive. The implant is an acoustic analogy of a Bragg stack with a ‘defect’ layer that acts as the sensing layer. A numerical study was performed on how the physical changes in the sensing layer can be deduced by monitoring the reflection amplitude spectrum of ultrasonic waves reflected from the implant. Coupled modes between the skin and the sensing layer were found to be a potential source of error and drift in the measurement. It was found that by increasing the number of layers in the stack that this could be minimized. A laboratory proof of concept system was developed using a glucose sensitive hydrogel as the sensing layer. It was possible to monitor the changing thickness and speed of sound of the hydrogel due to physiological relevant changes in glucose concentration.
Resumo:
This research investigates how functionality, rationality, and emotionality applied to urban furniture design contribute to the organization, legibility, and qualification of public spaces, according to different layouts, physical and visual qualities of the urban furniture as well as the quality of urban infrastructure that may influence the uses and appropriation of urban spaces by pedestrians, turning those spaces into socially centripetal or centrifugal places. The work consists of two parts. First refers to a bibliographical review concerning two main issues of the investigation: product design and legibility of public space, defining the conceptual and theoretical bases, linked to methodological strategies aimed at systemic planning and integrated management of urban furniture design and legibility of public spaces (sidewalks), that are necessary to define the existing relationships among the user s interface (pedestrians); product (urban artifacts); built environment (sidewalks). The second part refers to the achievement of empirical approach throughout visual analysis of public spaces and the functional and qualitative evaluation of the existing urban furniture in the central neighborhood of Cidade Alta, Natal, RN, according to the theoretical researched concepts and methodological procedures. The results expose the weaknesses and levels of intensity arising from the relations among public space, urban furniture, and users, revealing the need for theoretical and practical approaches which would help the decision-making in planning, designing and integrating innovative, sustainable, and ethical solutions in order to design attractive public spaces that could provide sociability and citizenship throughout integrated public management, city systemic thinking and urban identity. The suggested guidelines at the end of this research will provide the necessary strategies to design suitable urban furniture systems according to aesthetic and practical urban infrastructure and city context, aiming to ease visual and physical conflicts that may negatively interfere with the appropriation of public spaces by the citizens
Resumo:
Colloque tenu en Sorbonne les 17-19 janvier 2008
Resumo:
Os produtos obtidos da fermentação de pescados marinhos frescos registrados como fertilizantes orgânicos são ricos em nutrientes, possuem em sua composição quitina e quitosana, podendo-se constituir em um produto alternativo adequado para o controle de fitopatógenos. O objetivo deste trabalho foi estudar o potencial de um hidrolisado de peixe em controlar o oídio em abobrinha, F. oxysporum f. sp. lycopersici raça 3 em tomate e Pythium spp. em pepino. Nesse sentido, um fertilizante orgânico obtido da fermentação de resíduos de pescados marinhos frescos foi pulverizado semanalmente nas plantas de abobrinha, com o auxílio de um compressor de pintura 10 1b/pol2 m a 0%, 0,5%, 1%, 2%, 3%, 4%, 5% e 10% (v/v) para o controle do oídio. Este mesmo fertilizante foi incorporado ao substrato nas concentrações de 0%, 5%, 10%, 20%, 30%, 40%, 50% e 100% (por volume de água necessária para atingir a capacidade de campo), em experimento realizado dentro e fora de casa de vegetação. Outros experimentos realizados avaliaram a eficiência do hidrolisado de peixe no controle do tombamento causado por Pythium spp., em pepino e a murcha-de-fusário causada por Fusarium oxysporum f. sp. lycopersici raça 3, em tomate. Os experimentos foram realizados em casa de vegetação e o delineamento experimental foi inteiramente casualizado, com dez repetições por tratamento. Para o pepino, foi utilizada a técnica de estimular a população original do solo com aveia. Assim, o hidrolisado de peixe foi incorporado ao solo dez dias após a mistura com aveia, em concentrações de 0%, 5%, 10%, 20%, 30%, 40%, 50% e 100% do volume de água, para atingir a capacidade de campo do solo e com incubação aberta e fechada. Após dez dias de incubação, 200 ml da mistura foram adicionados ao colo das plantas de pepino no estádio de 2° folhas verdadeiras. A avaliação foi realizada após cinco dias, determinando-se o número de plântulas tombadas. O hidrolisado de peixe, tanto pulverizado na folhas quanto incorporado no substrato, não controlou o oídio da abobrinha. Por outro lado, pode ser observado o efeito do hidrolisado de peixe no desenvolvimento das plantas e no desenvolvimento de Trichoderma no substrato. A partir da concentração de 30%, não houve tombamento de plantas. Por outro lado, o tombamento foi de 100% para os tratamentos com 0 e 5% do fertilizante. Para o experimento do Fusarium, foram utilizados três isolados da raça 3 de Fusarium oxysporum f. sp. lycopersici (isolados 145, 146 e 149). Após a infestação, o substrato foi incubado por quinze dias com o hidrolisado de peixe e foi incorporado ao substrato nas seguintes concentrações: 0%, 5%, 10%, 20%, 30%, 40% e 50% volume de água necessária para atingir a capacidade de campo. Uma muda de tomate cultivar Santa Clara suscetível à raça 3 com 30 dias de idade, foi transferida para cada vaso. A severidade da doença foi avaliada após 40 dias, por meio de escala de notas para escurecimento vascular e sintomas externos. De modo geral, todas as doses do hidrolisado de peixe reduziram, significativamente, a severidade da doença.
Resumo:
Oil production and exploration techniques have evolved in the last decades in order to increase fluid flows and optimize how the required equipment are used. The base functioning of Electric Submersible Pumping (ESP) lift method is the use of an electric downhole motor to move a centrifugal pump and transport the fluids to the surface. The Electric Submersible Pumping is an option that has been gaining ground among the methods of Artificial Lift due to the ability to handle a large flow of liquid in onshore and offshore environments. The performance of a well equipped with ESP systems is intrinsically related to the centrifugal pump operation. It is the pump that has the function to turn the motor power into Head. In this present work, a computer model to analyze the three-dimensional flow in a centrifugal pump used in Electric Submersible Pumping has been developed. Through the commercial program, ANSYS® CFX®, initially using water as fluid flow, the geometry and simulation parameters have been defined in order to obtain an approximation of what occurs inside the channels of the impeller and diffuser pump in terms of flow. Three different geometry conditions were initially tested to determine which is most suitable to solving the problem. After choosing the most appropriate geometry, three mesh conditions were analyzed and the obtained values were compared to the experimental characteristic curve of Head provided by the manufacturer. The results have approached the experimental curve, the simulation time and the model convergence were satisfactory if it is considered that the studied problem involves numerical analysis. After the tests with water, oil was used in the simulations. The results were compared to a methodology used in the petroleum industry to correct viscosity. In general, for models with water and oil, the results with single-phase fluids were coherent with the experimental curves and, through three-dimensional computer models, they are a preliminary evaluation for the analysis of the two-phase flow inside the channels of centrifugal pump used in ESP systems
Resumo:
In the artificial lift method by Electrical Submersible Pump (ESP), the energy is transmitted for the well´s deep through a flat electric handle, where it is converted into mechanical energy through an engine of sub-surface, which is connected to a centrifugal pump. This transmits energy to the fluid under the pressure form, bringing it to the surface In this method the subsurface equipment is basically divided into: pump, seal and motor. The main function of the seal is the protect the motor, avoiding the motor´s oil be contaminated by oil production and the consequent burning of it. Over time, the seal will be wearing and initiates a contamination of motor oil, causing it to lose its insulating characteristics. This work presents a design of a magnetic sensor capable of detecting contamination of insulating oil used in the artificial lift method of oil-type Electrical Submersible Pump (ESP). The objective of this sensor is to generate alarm signal just the moment when the contamination in the isolated oil is present, enabling the implementation of a predictive maintenance. The prototype was designed to work in harsh conditions to reach a depth of 2000m and temperatures up to 150°C. It was used a simulator software to defined the mechanical and electromagnetic variables. Results of field experiments were performed to validate the prototype. The final results performed in an ESP system with a 62HP motor showed a good reliability and fast response of the prototype.
Resumo:
Historically, domestic tasks such as preparing food and washing and drying clothes and dishes were done by hand. In a modern home many of these chores are taken care of by machines such as washing machines, dishwashers and tumble dryers. When the first such machines came on the market customers were happy that they worked at all! Today, the costs of electricity and customers’ environmental awareness are high, so features such as low electricity, water and detergent use strongly influence which household machine the customer will buy. One way to achieve lower electricity usage for the tumble dryer and the dishwasher is to add a heat pump system. The function of a heat pump system is to extract heat from a lower temperature source (heat source) and reject it to a higher temperature sink (heat sink) at a higher temperature level. Heat pump systems have been used for a long time in refrigerators and freezers, and that industry has driven the development of small, high quality, low price heat pump components. The low price of good quality heat pump components, along with an increased willingness to pay extra for lower electricity usage and environmental impact, make it possible to introduce heat pump systems in other household products. However, there is a high risk of failure with new features. A number of household manufacturers no longer exist because they introduced poorly implemented new features, which resulted in low quality and product performance. A manufacturer must predict whether the future value of a feature is high enough for the customer chain to pay for it. The challenge for the manufacturer is to develop and produce a high-performance heat pump feature in a household product with high quality, predict future willingness to pay for it, and launch it at the right moment in order to succeed. Tumble dryers with heat pump systems have been on the market since 2000. Paper I reports on the development of a transient simulation model of a commercial heat pump tumble dryer. The measured and simulated results were compared with good similarity. The influence of the size of the compressor and the condenser was investigated using the validated simulation model. The results from the simulation model show that increasing the cylinder volume of the compressor by 50% decreases the drying time by 14% without using more electricity. Paper II is a concept study of adding a heat pump system to a dishwasher in order to decrease the total electricity usage. The dishwasher, dishware and water are heated by the condenser, and the evaporator absorbs the heat from a water tank. The majority of the heat transfer to the evaporator occurs when ice is generated in the water tank. An experimental setup and a transient simulation model of a heat pump dishwasher were developed. The simulation results show a 24% reduction in electricity use compared to a conventional dishwasher heated with an electric element. The simulation model was based on an experimental setup that was not optimised. During the study it became apparent that it is possible to decrease electricity usage even more with the next experimental setup.
Resumo:
Although its great potential as low to medium temperature waste heat recovery (WHR) solution, the ORC technology presents open challenges that still prevent its diffusion in the market, which are different depending on the application and the size at stake. Focusing on the micro range power size and low temperature heat sources, the ORC technology is still not mature due to the lack of appropriate machines and working fluids. Considering instead the medium to large size, the technology is already available but the investment is still risky. The intention of this thesis is to address some of the topical themes in the ORC field, paying special attention in the development of reliable models based on realistic data and accounting for the off-design performance of the ORC system and of each of its components. Concerning the “Micro-generation” application, this work: i) explores the modelling methodology, the performance and the optimal parameters of reciprocating piston expanders; ii) investigates the performance of such expander and of the whole micro-ORC system when using Hydrofluorocarbons as working fluid or their new low GWP alternatives and mixtures; iii) analyzes the innovative ORC reversible architecture (conceived for the energy storage), its optimal regulation strategy and its potential when inserted in typical small industrial frameworks. Regarding the “Industrial WHR” sector, this thesis examines the WHR opportunity of ORCs, with a focus on the natural gas compressor stations application. This work provides information about all the possible parameters that can influence the optimal sizing, the performance and thus the feasibility of installing an ORC system. New WHR configurations are explored: i) a first one, relying on the replacement of a compressor prime mover with an ORC; ii) a second one, which consists in the use of a supercritical CO2 cycle as heat recovery system.