824 resultados para Ultrasound (US)
Resumo:
Intralaboratorial and interlaboratorial variabilities can be obtained by conducting an specially designed interlaboratory program. Using the analysis of variance technique one can calculate the r (repeatability) and R (reproducibility) indexes that can help participant laboratories to monitor their routine quality control procedures. An example is described using data obtained from an interlaboratory program where twelve laboratories determined total iron content in silicon metal sample by using flame atomic absorption spectrometry.
Resumo:
1 kartta : vär. ; 43,8 x 54,8 cm, lehti 46 x 56,7 cm.
Resumo:
The purpose of this study is to define what determinants affect the Credit spread. There are two theoretical frameworks to study this: structural models and reduced form models. Structural models indicate that the main determinants are company leverage, volatility and risk-free interest rate, and other market and firm-specific variables. The purpose is to determine which of these theoretical determinants can explain the CDS spread and also how these theoretical determinants are affected by the financial crisis in 2007. The data is collected from 30 companies in the US Markets, mainly S&P Large Cap. The sample time-frame is 31.1.2004 – 31.12.2009. Empirical studies indicate that structural models can explain the CDS spreads well. Also, there were significant differences between bear and bull markets. The main determinants explaining CDS spreads were leverage and volatility. The other determinants were significant, depending on the sample period. However, these other variables did not explain the spread consistently.
Resumo:
There are several filtration applications in the pulp and paper industry where the capacity and cost-effectiveness of processes are of importance. Ultrafiltration is used to clean process water. Ultrafiltration is a membrane process that separates a certain component or compound from a liquid stream. The pressure difference across the membrane sieves macromolecules smaller than 0.001-0.02 μm through the membrane. When optimizing the filtration process capacity, online information about the conditions of the membrane is needed. Fouling and compaction of the membrane both affect the capacity of the filtration process. In fouling a “cake” layer starts to build on the surface of the membrane. This layer blocks the molecules from sieving through the membrane thereby decreasing the yield of the process. In compaction of the membrane the structure is flattened out because of the high pressure applied. The higher pressure increases the capacity but may damage the structure of the membrane permanently. Information about the compaction is needed to effectively operate the filters. The objective of this study was to develop an accurate system for online monitoring of the condition of the membrane using ultrasound reflectometry. Measurements of ultrafiltration membrane compaction were made successfully utilizing ultrasound. The results were confirmed by permeate flux decline, measurements of compaction with a micrometer, mechanical compaction using a hydraulic piston and a scanning electron microscope (SEM). The scientific contribution of this thesis is to introduce a secondary ultrasound transducer to determine the speed of sound in the fluid used. The speed of sound is highly dependent on the temperature and pressure used in the filters. When the exact speed of sound is obtained by the reference transducer, the effect of temperature and pressure is eliminated. This speed is then used to calculate the distances with a higher accuracy. As the accuracy or the resolution of the ultrasound measurement is increased, the method can be applied to a higher amount of applications especially for processes where fouling layers are thinner because of smaller macromolecules. With the help of the transducer, membrane compaction of 13 μm was measured in the pressure of 5 bars. The results were verified with the permeate flux decline, which indicated that compaction had taken place. The measurements of compaction with a micrometer showed compaction of 23–26 μm. The results are in the same range and confirm the compaction. Mechanical compaction measurements were made using a hydraulic piston, and the result was the same 13 μm as obtained by applying the ultrasound time domain reflectometry (UTDR). A scanning electron microscope (SEM) was used to study the structure of the samples before and after the compaction.
Resumo:
Objective:To evaluate the prevalence of carpal tunnel syndrome in candidates for bariatric surgery comparing with the non-obese population and verify the effects on it of bariatric treatment. Methods:We studiedthree groups of individuals: 1) patients waiting for bariatric surgery (preoperative); 2) individuals who had already undergone the procedure (postoperative); and 3) control group. We collected demographic and clinical data of carpal tunnel syndrome. The Ultrasound examination was carried out to diagnose the syndrome by measuring the median nerve area. Results:We included 329 individuals (114 in the preoperative group, 90 in the postoperative group and 125 controls). There was a higher prevalence of paresthesias (p=0.0003), clinical tests (p=0.0083) on the preoperative group when compared with controls (p<0.00001). There were lowe levels of paresthesias (p=0.0002) and median nerve area (p=0.04) in postoperative patients but with no significant difference in general. A significant difference was found between the preoperative and postoperative groups (p=0.05) in those who performed non-manual work.Conclusion: There was a higher prevalence of carpal tunnel syndrome in the preoperative group compared with the control one, but no significant difference was observed between the pre and postoperative groups in general. There was difference between pre and postoperative groups for non-manual workers.
Resumo:
OBJETIVO: analisar qual das características propostas pelo BIRADS-US tem maior impacto na diferenciação das lesões benignas das malignas. MÉTODOS: estudamos as características ultra-sonográficas do BIRADS em 384 nódulos submetidos à biópsia percutânea no período de fevereiro de 2003 a dezembro de 2006. Utilizou-se, para o exame, o aparelho Logic 5, com transdutor linear multifreqüencial de 7,5-12 MHz. A análise ultra-sonográfica do nódulo foi baseada no BIRADS-US levando em conta: forma, orientação, margem, limites da lesão, ecogenicidade, características acústicas posteriores, o tecido circunjacente e a presença de calcificações. Estes dados foram submetidos à análise estatística com modelo de regressão logística. Para o estudo de associação entre estas variáveis utilizamos o teste do c² e também calculamos a sensibilidade e a especificidade das variáveis "tecido ao redor", "calcificações", "efeito posterior", "limite da lesão" e "orientação". RESULTADOS: as lesões benignas representaram 42,4% e as malignas, 57,6%. A análise por regressão logística encontrou odds ratio (OR) aumentado para câncer de 7,7 vezes quando o tecido ao redor esteve alterado, de 6,2 vezes quando houve presença das microcalcificações no interior das lesões, de 1,9 quando o efeito acústico foi sombra, de 25,0 vezes quando houve o halo ecogênico e de 7,1 vezes quando a orientação foi não paralela. CONCLUSÕES: dentre as características estudadas, o limite da lesão, representado pela presença ou não do halo ecogênico, é o mais importante diferenciador das massas benignas das malignas.
Resumo:
PURPOSE: To evaluate changes to the pelvic floor of primiparous women with different delivery modes, using three-dimensional ultrasound. METHODS: A prospective cross-sectional study on 35 primiparae divided into groups according to the delivery mode: elective cesarean delivery (n=10), vaginal delivery (n=16), and forceps delivery (n=9). Three-dimensional ultrasound on the pelvic floor was performed on the second postpartum day with the patient in a resting position. A convex volumetric transducer (RAB4-8L) was used, in contact with the large labia, with the patient in the gynecological position. Biometric measurements of the urogenital hiatus were taken in the axial plane on images in the rendering mode, in order to assess the area, anteroposterior and transverse diameters, average thickness, and avulsion of the levator ani muscle. Differences between groups were evaluated by determining the mean differences and their respective 95% confidence intervals. The proportions of levator ani muscle avulsion were compared between elective cesarean section and vaginal birth using Fisher's exact test. RESULTS: The mean areas of the urogenital hiatus in the cases of vaginal and forceps deliveries were 17.0 and 20.1 cm², respectively, versus 12.4 cm² in the Control Group (elective cesarean). Avulsion of the levator ani muscle was observed in women who underwent vaginal delivery (3/25), however there was no statistically significant difference between cesarean section and vaginal delivery groups (p=0.5). CONCLUSION: Transperineal three-dimensional ultrasound was useful for assessing the pelvic floor of primiparous women, by allowing pelvic morphological changes to be differentiated according to the delivery mode.
Resumo:
kuv., 12 x 15 cm
Resumo:
kuv., 11 x 15 cm