825 resultados para The use of robots in education


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Timely diagnosis of invasive candidiasis (IC) remains difficult as the clinical presentation is not specific and blood cultures lack sensitivity and need a long incubation time. Thus, non-culture-based methods for diagnosing IC have been developed. Mannan antigen (Mn) and anti-mannan antibodies (A-Mn) are present in patients with IC. On behalf of the Third European Conference on Infections in Leukemia, the performance of these tests was analysed and reviewed. METHODS: The literature was searched for studies using the commercially available sandwich enzyme-linked immunosorbent assays (Platelia™, Bio-Rad Laboratories, Marnes-la-Coquette, France) for detecting Mn and A-Mn in serum. The target condition of this review was IC defined according to 2008 European Organization for Research and Treatment of Cancer/Mycoses Study Group criteria. Sensitivity, specificity and diagnostic odds ratios (DOR) were calculated for Mn, A-Mn and combined Mn/A-Mn testing. RESULTS: Overall, 14 studies that comprised 453 patients and 767 controls were reviewed. The patient populations included in the studies were mainly haematological and cancer cases in seven studies and mainly intensive care unit and surgery cases in the other seven studies. All studies but one were retrospective in design. Mn sensitivity was 58% (95% confidence interval [CI], 53-62); specificity, 93% (95% CI, 91-94) and DOR, 18 (95% CI 12-28). A-Mn sensitivity was 59% (95% CI, 54-65); specificity, 83% (95% CI, 79-97) and DOR, 12 (95% CI 7-21). Combined Mn/A-Mn sensitivity was 83% (95% CI, 79-87); specificity, 86% (95% CI, 82-90) and DOR, 58 (95% CI 27-122). Significant heterogeneity of the studies was detected. The sensitivity of both Mn and A-Mn varied for different Candida species, and it was the highest for C. albicans, followed by C. glabrata and C. tropicalis. In 73% of 45 patients with candidemia, at least one of the serological tests was positive before the culture results, with mean time advantage being 6 days for Mn and 7 days for A-Mn. In 21 patients with hepatosplenic IC, 18 (86%) had Mn or A-Mn positive test results at a median of 16 days before radiological detection of liver or spleen lesions. CONCLUSIONS: Mn and A-Mn are useful for diagnosis of IC. The performance of combined Mn/A-Mn testing is superior to either Mn or A-Mn testing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The level of information provided by ink evidence to the criminal and civil justice system is limited. The limitations arise from the weakness of the interpretative framework currently used, as proposed in the ASTM 1422-05 and 1789-04 on ink analysis. It is proposed to use the likelihood ratio from the Bayes theorem to interpret ink evidence. Unfortunately, when considering the analytical practices, as defined in the ASTM standards on ink analysis, it appears that current ink analytical practices do not allow for the level of reproducibility and accuracy required by a probabilistic framework. Such framework relies on the evaluation of the statistics of the ink characteristics using an ink reference database and the objective measurement of similarities between ink samples. A complete research programme was designed to (a) develop a standard methodology for analysing ink samples in a more reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in a forensic context. This report focuses on the first of the three stages. A calibration process, based on a standard dye ladder, is proposed to improve the reproducibility of ink analysis by HPTLC, when these inks are analysed at different times and/or by different examiners. The impact of this process on the variability between the repetitive analyses of ink samples in various conditions is studied. The results show significant improvements in the reproducibility of ink analysis compared to traditional calibration methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we use CGE modelling techniques to identify the impact on energy use of an improvement in energy efficiency in the household sector. The main findings are that 1) when the price of energy is measured in natural units, the increase in efficiency yields only to a modification of tastes, changing as a result, the composition of household consumption; 2) when households internalize efficiency, the improvement in energy efficiency reduces the price of energy in efficiency units, providing a source of improved competitiveness as the nominal wage and the price level both fall; 3) the short-run rebound can be greater than the long run rebound if the household demand elasticity is the same for both time frames, however, the short run rebound is always lower than in the long-run if the demand for energy is relatively more elastic in the long-run; 4) the introduction of habit formation changes the composition of household consumption, modifying the magnitude of the household rebound only in the short-run. In this period, household and economy wide rebound are lowest for external habit formation and highest when consumers’ preferences are defined using a conventional utility function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper extends previous research and discussion on the use of multivariate continuous data, which are about to become more prevalent in forensic science. As an illustrative example, attention is drawn here on the area of comparative handwriting examinations. Multivariate continuous data can be obtained in this field by analysing the contour shape of loop characters through Fourier analysis. This methodology, based on existing research in this area, allows one describe in detail the morphology of character contours throughout a set of variables. This paper uses data collected from female and male writers to conduct a comparative analysis of likelihood ratio based evidence assessment procedures in both, evaluative and investigative proceedings. While the use of likelihood ratios in the former situation is now rather well established (typically, in order to discriminate between propositions of authorship of a given individual versus another, unknown individual), focus on the investigative setting still remains rather beyond considerations in practice. This paper seeks to highlight that investigative settings, too, can represent an area of application for which the likelihood ratio can offer a logical support. As an example, the inference of gender of the writer of an incriminated handwritten text is forwarded, analysed and discussed in this paper. The more general viewpoint according to which likelihood ratio analyses can be helpful for investigative proceedings is supported here through various simulations. These offer a characterisation of the robustness of the proposed likelihood ratio methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As an emerging alternative to DXA, there is a growing interest in the use of quantitative ultrasound (QUS) measurements for the non invasive assessment of fracture risk in the management of osteoporosis. While the potential of QUS in the management of osteoporosis have been highly recognized by the scientific community and granted by the majority of the international bone disease organizations, it becomes important to develop strategies how to use ultrasound clinically. Our paper is highlighting Swiss operational clinical propositions for 2 QUS devices sold in Switzerland, on how to use the QUS in the management of osteoporosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ferromagnetic dacron is proposed as an alternative solid-phase for magnetic enzyme immunoassays. Human serum albumin (HSA) was covalentlyimmobilized onto ferromagnetic dacron and as enzyme immunoassay was developed using anti-HSA rabbit sera. Peroxidase, o-phenylenediamine (OPD) and hydrogen peroxide were used anti-HSA rabbit sera. Peroxidase, o-phenylenediamine (OPD) and hydrogen peroxide were used as the enzymatic label and substrates, respectively. Best results were observed when particles of 63-100 µm (diameter) and 10 µg of immobilized antigen were used. Positive reactions were detected until dilutions of1:51200 of immune sera. Its reproducibility was similar to standard ELISA. Disruption of the immunocomplexes formed and recuperation of the immobilized antigen in other immunoassays also proved to be reliable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of the human immunodeficiency virus (HIV) infection on IgG production against purified protein derivative (PPD) and 2,3-diacil-trehalose (SL-IV) was investigated by an enzyme-linked immunosorbent assay (ELISA) test. Comparison between the antigens showed that immunocompetent patients produce preferentially antibodies to SL-IV than to PPD (73.3% versus 63.3%). Combination of these results showed an increase of the sensitivity to 80%, which decreased over the spectrum of immunodepression caused by HIV. In the tuberculous HIV seropositive group the sensitivities of SL-IV and PPD were 36.4% versus 40% and 0% versus 22.2% in the tuberculosis/acquired immunodeficiency syndrome (TB/AIDS) group. Combination of these results gave respectively 54.5% and 20%, showing that serological tests have limited value for diagnosis of tuberculosis in HIV infected patients. High antibody levels were observed in HIV seropositive asymptomatic group, but only two individuals were positive for both antigens. In the follow up, one of them developed tuberculous lymphadenitis, indicating that further work is needed to access the value of serological tests in predicting tuberculosis in HIV infected individuals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Discs of polyvinyl alcohol cross-linked with glutaraldehyde were synthesized under acid catalysis (H2SO4). Then, the antigen F1 purified from Yersinia pestis was covalently linked to this modified polymer. Afterwards, an enzyme-linked immunosorbent assay (ELISA) was established for the diagnosis of plague in rabbit and human. The best conditions for the method were achieved by using 1.3 ¼g of F1 prepared in 0.067 M phosphate buffer, pH 7.2, containing 1 M NaCl (PBS); anti-IgG peroxidase conjugate diluted 6,000 times and as a blocking agent 3% w/v skim milk in PBS. The titration of positive rabbit serum according to this procedure detected antibody concentrations up to 1:12,800 times. The present method, the conventional ELISA and passive haemagglutination assay are compared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study shows the efficiency of passive sampling to reveal industrial and agricultural pollution trends. Two practical applications for nonpolar and polar contaminants are presented. Low-density polyethylene (LDPE) samplers were deployed for one year in the Venoge River (VD) to monitor indicator PCBs (iPCBs, IUPAC nos. 28, 52, 101, 138, 153 and 180). The results showed that the impact of PCB emissions into the river is higher in summer than in other seasons due to the low flow rate of the river during this period. P,olar organic chemical integrative samplers (POCIS) were deployed for 4 months in the Sion-Riddes canal (VS) to investigate herbicides (terbuthylazine, diuron and linuron). Desisopropylatrazine-d5 (DIA-d5) was tested as a performance reference compound (PRC) to estimate aqueous concentration. The results showed an increase of water contamination due to the studied agricultural area. The maximal contamination was observed in April and corresponds to the period of herbicide application on the crops.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the past twenty years, various instruments have been developed for the assessment of substance use in adolescents, mainly in the United States. However, few of them have been adapted to, and validated in, French-speaking populations. Consequently, although increasing alcohol and drug use among teenagers has become a major concern, the various health and social programs developed in response to this specific problem have received little attention with regard to follow-up and outcome assessment. A standardized multidimensional assessment instrument adapted for adolescents is needed to assess the individual needs of adolescents and assign them to the most appropriate treatment setting, to provide a single measurement within and across health and social systems, and to conduct treatment outcome evaluations. Moreover, having an available instrument makes it possible to develop longitudinal and transcultural research studies. For this reason, a French version of the Adolescent Drug Abuse Diagnosis (ADAD) was developed and validated at the University Child and Adolescent Psychiatric Clinic in Lausanne, Switzerland. This article aims to discuss the methodological issues that we faced when using the ADAD instrument in a 4-year longitudinal study including adolescent substance users. Methodological aspects relating to the content and format of the instrument, the assessment administration and the statistical analyses are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bacillus spp. based larvides are increasingly replacing, with numerous advantages, chemical insecticides in programmes for controlling black fly and mosquito populations. Brazil was among the pioneers in adopting Bacillus thuringiensis israelensis (B.t.i) to control black flies. However, the major current mosquito control programme in Brazil, the Programme for Eradication of Aedes aegypti launched in 1997, only recently decided to replace temephos by B.t.i based larvicides, in the State of Rio de Janeiro. In the last decade, works developed by research groups in Brazilian institutions have generated a significant contribution to this subject through the isolation of B. sphaericus new strains, the development of new products and the implementation of field trials of Bacillus efficacy against mosquito species under different environmental conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resume : L'utilisation de l'encre comme indice en sciences forensiques est décrite et encadrée par une littérature abondante, comprenant entre autres deux standards de l'American Society for Testing and Materials (ASTM). La grande majorité de cette littérature se préoccupe de l'analyse des caractéristiques physiques ou chimiques des encres. Les standards ASTM proposent quelques principes de base qui concernent la comparaison et l'interprétation de la valeur d'indice des encres en sciences forensiques. L'étude de cette littérature et plus particulièrement des standards ASTM, en ayant a l'esprit les développements intervenus dans le domaine de l'interprétation de l'indice forensique, montre qu'il existe un potentiel certain pour l'amélioration de l'utilisation de l'indice encre et de son impact dans l'enquête criminelle. Cette thèse propose d'interpréter l'indice encre en se basant sur le cadre défini par le théorème de Bayes. Cette proposition a nécessité le développement d'un système d'assurance qualité pour l'analyse et la comparaison d'échantillons d'encre. Ce système d'assurance qualité tire parti d'un cadre théorique nouvellement défini. La méthodologie qui est proposée dans ce travail a été testée de manière compréhensive, en tirant parti d'un set de données spécialement créer pour l'occasion et d'outils importés de la biométrie. Cette recherche répond de manière convaincante à un problème concret généralement rencontré en sciences forensiques. L'information fournie par le criminaliste, lors de l'examen de traces, est souvent bridée, car celui-ci essaie de répondre à la mauvaise question. L'utilisation d'un cadre théorique explicite qui définit et formalise le goal de l'examen criminaliste, permet de déterminer les besoins technologiques et en matière de données. Le développement de cette technologie et la collection des données pertinentes peut être justifiées économiquement et achevée de manière scientifique. Abstract : The contribution of ink evidence to forensic science is described and supported by an abundant literature and by two standards from the American Society for Testing and Materials (ASTM). The vast majority of the available literature is concerned with the physical and chemical analysis of ink evidence. The relevant ASTM standards mention some principles regarding the comparison of pairs of ink samples and the evaluation of their evidential value. The review of this literature and, more specifically, of the ASTM standards in the light of recent developments in the interpretation of forensic evidence has shown some potential improvements, which would maximise the benefits of the use of ink evidence in forensic science. This thesis proposes to interpret ink evidence using the widely accepted and recommended Bayesian theorem. This proposition has required the development of a new quality assurance process for the analysis and comparison of ink samples, as well as of the definition of a theoretical framework for ink evidence. The proposed technology has been extensively tested using a large dataset of ink samples and state of the art tools, commonly used in biometry. Overall, this research successfully answers to a concrete problem generally encountered in forensic science, where scientists tend to self-limit the usefulness of the information that is present in various types of evidence, by trying to answer to the wrong questions. The declaration of an explicit framework, which defines and formalises their goals and expected contributions to the criminal and civil justice system, enables the determination of their needs in terms of technology and data. The development of this technology and the collection of the data is then justified economically, structured scientifically and can be proceeded efficiently.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We performed a pilot study to compare vertebral fracture assessments (VFA) and lateral X-rays in terms of inter- and intraobserver reliability and degree of correlation for the detection of syndesmophytes in ankylosing spondylitis (AS). We recruited 19 patients with AS and recent lumbar or cervical lateral X-rays with at least one syndesmophyte. Each patient underwent dual-energy X-ray absorptiometry with measurement of bone mineral density and dorso-lumbar VFA. Intra- and interreader reliability for VFA and X-rays were measured using 2 independent, blinded observers and Cohen's kappa values. An adapted modified Stoke Ankylosing Spondylitis Spinal Score (amSASSS) was generated with each method, and these 2 values correlated. For X-rays, intraobserver and interobserver agreement were 94.3% (κ = 0.83) and 98.6% (κ = 0.96), respectively; for VFA, corresponding values were 92.8% (κ = 0.79) and 93.8% (κ = 0.82). Overall agreement between the 2 techniques was 88.6% (κ = 0.72). The Pearson correlation coefficient for the 2 methods was 0.95 for the modified Stoke Ankylosing Spondylitis Spinal Score . Per dual-energy X-ray absorptiometry-generated bone mineral density, >50% of patients were osteopenic and 10% osteoporotic. In terms of reproducibility and correlation with X-rays, performing a VFA appears to be a candidate for assessing radiographic damage in AS, thought further research is necessary to justify this indication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study focuses on methylamphetamine (MA) seizures made by the Australian Federal Police (AFP) to investigate the use of chemical profiling in an intelligence perspective. Correlation coefficients were used to obtain a similarity degree between a population of linked samples and a population of unlinked samples. Although it was demonstrated that a general framework can be followed for the use of any forensic case data in an intelligence-led perspective, threshold values have to be re-evaluated for each type of illicit drug investigated. Unlike the results obtained in a previous study on 3,4-methylenedioxymethylamphetamine (MDMA) seizures, chemical profiles of MA samples coming from the same seizure showed relative inhomogeneity, limiting their ability to link seizures. Different hypotheses were investigated to obtain a better understanding of this inhomogeneity although no trend was observed. These findings raise an interesting discussion in regards to the homogeneity and representativeness of illicit drug seizures (for intelligence purposes). Further, it also provides some grounds to discuss the initial hypotheses and assumptions that most forensic science studies are based on.