The use of ferromagnetic dacron as solid-phase in enzyme immunoassays
Data(s) |
01/06/1994
|
---|---|
Resumo |
Ferromagnetic dacron is proposed as an alternative solid-phase for magnetic enzyme immunoassays. Human serum albumin (HSA) was covalentlyimmobilized onto ferromagnetic dacron and as enzyme immunoassay was developed using anti-HSA rabbit sera. Peroxidase, o-phenylenediamine (OPD) and hydrogen peroxide were used anti-HSA rabbit sera. Peroxidase, o-phenylenediamine (OPD) and hydrogen peroxide were used as the enzymatic label and substrates, respectively. Best results were observed when particles of 63-100 µm (diameter) and 10 µg of immobilized antigen were used. Positive reactions were detected until dilutions of1:51200 of immune sera. Its reproducibility was similar to standard ELISA. Disruption of the immunocomplexes formed and recuperation of the immobilized antigen in other immunoassays also proved to be reliable. |
Formato |
text/html |
Identificador |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02761994000200012 |
Idioma(s) |
en |
Publicador |
Instituto Oswaldo Cruz, Ministério da Saúde |
Fonte |
Memórias do Instituto Oswaldo Cruz v.89 n.2 1994 |
Palavras-Chave | #magnetic ELISA #ferromagnetic dacron #human serum albumin |
Tipo |
journal article |