978 resultados para Testes de fixação do latex
Resumo:
Films containing different volumes of latex of natural rubber (NR) in a fixed mass of poly (vinylidene fluoride) (PVDF) powder were fabricated by compressing under annealing a mixture of both materials without using any solvent. This is an important issue keeping in mind that these films have to be used in the future as biomaterials in different applications once the solvents that are used to dissolve the PVDF become toxic to human. The films with different percentage of latex in PVDF were characterized using microRaman scattering and Fourier transform infrared absorption (FTIR) spectroscopies, thermomechanical techniques using thermogravimetry (TG), differential scanning calorimetry (DSC), dynamical-mechanical analysis (DMA) and scanning electron microscopy (SEM). The results showed that the latex of NR and PVDF do not interact chemically, leading to the formation of a polymeric blend with high thermal stability and mechanical properties suitable for applications involving bone (prostheses, for instance). Besides, the results recorded using the micro-Raman technique revealed that for a fixed amount of PVDF the higher the amount of latex in the blend, the better the miscibility between both materials. Copyright (c) 2005 John Wiley & Sons, Ltd.
Resumo:
This paper surveys the topology of macroporous silica prepared using latex templates covering the submicrometric range (0.1-0.7 mu m). The behavior of latex spheres in aqueous dispersion has been analyzed by dynamic light scattering (DLS) measurement indicating the most appropriate conditions to form well-defined cubic arrays. The optical behavior of latex spheres has been analyzed by transmittance and reflectance measurements in order to determine their diameter and filling factor when they were assembled in bidimensional arrays. Macroscopic templates have been obtained by a centrifugation process and their crystalline ordering has been confirmed by porosimetry and scanning electron microscopy. These self-assembled structures have been used to produce macroporous silica, whose final topology depends on the pore size distribution of the original template. It has been seen that latex spheres are ordered in a predominant fcc arrangement with slipping of tetragonal pores due to the action of attractive electrostatic interactions. The main effect is to change the spherical shape of voids in macroporous silica into a hexagonal configuration with possible applications to fabricate photonic devices with novel optical properties. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Testicles of 30 mongrel cats were analyzed histologically and morphometrically, divided into three groups: G1 (1-2 years old), G2 (over 2 and up to 4 years old) and G3 (over 4 and up to 6 years old). After orchiectomy and histopathology, the morphometric parameters studied were: thickness of the tunica albuginea (72 mu m) and seminiferous epithelium (77.19 mu m), perimeter (53.81; 90.57 mu m), (54.80; 101.07 mu m); area (174.23; 494.55 mu m(2)), (176.68; 629.70 mu m(2)); maximum diameter (14.94; 28.02 mu m), (14.76; 31.66 mu m); minimum diameter (13.25; 21.92 mu m), (13.30; 24.52 mu m); and shape factor (index for regularity of the format) (1.36; 1.36), (1.39; 1.35) of the nucleus and cytoplasm of spermatogonia and Leydig cells, respectively. The results can be used for comparative studies and contribute knowledge concerning the height of the seminiferous epithelium, thickness of the tunica albuginea and size of spermatogonia and Leydig cells.
Resumo:
They were casted pieces using three kinds of alloy (Ni-Cr, Ag-Sn and Cu-Al) with circular and smooth surface. They were cemented to human teeth, on occlusal surface, grounded at dentin level, through three different materials kind (zinc polycarboxylate cement, glassionomer cement and composite). After 24 hours storing, the samples were subjected to the tensile test. The results showed that the samples cemented with composite and the casts made with Ag-Sn alloy had higher bond strength.
Resumo:
The purpose of this study was to compare the enamel/resin/metal bond tensile strength by using human canines, in which castings were bonded. These castings were obtained by Co-Cr or Ni-Cr alloys and showed four types of mechanisms of retention: 50 micrograms aluminum oxide abrasive, electrochemical etch, acrylic beads metal mesh. The castings were bonded utilizing Comspan Opaque and Panavia Ex. The specimens were subjected to tensile forces after 24 hours in an Instron machine. The castings subjected to 50 micrograms aluminum oxide abrasive and bonded utilizing Panavia EX showed the biggest bond tensile strength.
Resumo:
Although rare, some anurans show multimale spawning. Herein we present data on testes mass relative to body mass for 11 leptodactylids and report multimale spawning in Leptodactylus chaquensis and Leptodactylus podicipinus. Testes mass averaged 4.13% of body mass for L. chaquensis and 0.75% for L. podicipinus. Testes size of both leptodactylid species with multimale spawning show that they are large and close to values recorded for rhacophorid frogs with multimale breeding (0.71-7.79%). Large testes size in frogs with multimale spawning supports the sperm competition hypothesis.
Resumo:
Studies were carried out to natural papain inhibitor from papaya latex. Fresh latex from green fruits of Carica papaya was collected and immediately transported in ice bath to the lab, from which three fractions with inhibitor effect of esterase papain activity were isolated by latex dialysis, Sephadex G-25 gel filtration and ionic exchange chromatography in SP-Sephadex C-25. The isolated fractions, identified as inhibitors I and II, showed a negative reaction with ninhydrin; however, the fraction identified as P-III showed positive reaction with ninhydrin. Kinetics data showed non-competitive inhibition (inhibitor I) and uncompetitive (inhibitors II and P -III).
Resumo:
Recently, regular and white mineral trioxide aggregate (MTA) are being used in Dentistry as retrofilling materials. Genotoxicity and cytotoxicity tests form an important part of cancer research and risk assessment of potential carcinogens. Thus, the goal of this study was to examine the genotoxicity and cytotoxicity of regular and white MTA in vitro by the single cell gel (comet) assay and trypan blue exclusion test, respectively. Mouse lymphoma cells were exposed to two presentation forms of MTA at final concentrations ranging from 1 to 1,000 μg/mL for 3 h at 37°C. The results showed that both compounds tested did not produce genotoxic effects at all concentrations evaluated. Likewise, no statistically significant differences (p > 0.05) were observed in cytotoxicity. Taken together, our results suggest that regular and white MTA are not genotoxins and are not able to interfere in cellular viability as assessed by single cell gel (comet) assay and trypan blue assay, respectively.
Study of chromosomal and nucleolar aspects in testes of Nysius californicus (Heteroptera: Lygaeidae)
Resumo:
In Nysius californicus (family Lygaeidae, subfamily Orsillinae), a pest commonly known as the seed bug, the chromosome complement is 2n = 16 (12A + 2m + XY), testes are formed by seven seminiferous tubules covered by an orange-colored membrane, and spermatogenesis is cystic. At prophase, sex chromosomes are heteropycnotic and autosomes usually show a chiasma. At metaphase, sex chromosomes along with microchromosomes may be seen located at the center of a ring formed by the remaining autosomes. A characteristic specific of N. californicus was the presence of nucleolar material observed from the cystic cell to the completely differentiated spermatozoon. Variations in size, shape and location of the nucleolar material occur during this process, denoting a variable degree of activity in the different stages. ©FUNPEC-RP.
Resumo:
This study present a novel NO sensor made of a spin trap (iron(II)-diethyldithiocarbamate complex, FeDETC) incorporated in a latex rubber matrix and works as a trap for NO, which is detectable by Electron Paramagnetic Resonance (EPR). We explored the optimization of our sensors changing systematically two fabrication parameters: the latex rubber matrix temperature of polymerization and FeDETC concentration inside the matrix. The sensor was prepared in four different temperatures: 4, 10, 20 and 40°C. The FeDETC concentration was also varied from 0.975 to 14.8 mM. We observed a variation of the EPR signals from the sensors prepared at different conditions. We found a high stability of the EPR response from our sensor, 40 days at RT. The best sensor was made with a latex rubber matrix polymerized at 10°C and with a FeDETC concentration of 14.8 mM. In vivo tests show good biocompatibility of our sensor. © 2007 Asian Network for Scientific Information.
Resumo:
The need for a rational use of water and supply of food for a growing world population have led to the development of research in the area of irrigation systems. Thus, some irrigation systems which join efficiency with low cost of material have been developed. Although some technical characteristics are provided by the manufacturers, tests are required to verify functioning of the system and uniformity of water distribution. Continuous research on uniformity, characteristics of the materials and design of water distribution systems is essential for system improvement. Therefore, the objective of this work was to evaluate the CV (manufacturer's coefficient of variation) of Amanco microsprinkler (1.0 mm light green nipple) using bench testing in the laboratory of Irrigation at UNESP - FCA campus of Botucatu-SP. Twenty-five microsprinklers in a sequential design were used in the tests. Three flow systems were tested as follows: a Coil system based on serial connected pipes; a Lateral system, the most common system in which secondary lines are fed by a main line; and a Mesh system used in the urban water supply. The results showed that 4.17% CVf met the production standards and the Lateral and Mesh systems were similar regarding outflow using bench testing. The Mesh system presented the highest mean value of outflow and the lowest range of variation.