991 resultados para Technology Companies


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Companies and researchers involved in developing miniaturized electronic devices face the basic problem of the needed batteries size, finite life of time and environmental pollution caused by their final deposition. The current trends to overcome this situation point towards Energy Harvesting technology. These harvesters (or scavengers) store the energy from sources present in the ambient (as wind, solar, electromagnetic, etc) and are costless for us. Piezoelectric devices are the ones that show a higher power density, and materials as ceramic PZT or polymeric PVDF have already demonstrated their ability to act as such energy harvester elements. Combinations between piezoelectric and electromagnetic mechanism have been also extensively investigated. Nevertheless, the power generated by these combinations is limited under the application of small magnetic fields, reducing the performance of the energy harvester [1]. In the last years the appearance of magnetoelectric (ME) devices, in which the piezoelectric deformation is driven by the magnetostrictive element, enables to extract the energy of very small electromagnetic signals through the generated magnetoelectric voltage at the piezoelectric element. However, very little work has been done testing PVDF polymer as piezoelectric constituent of the ME energy harvester device, and only to be proposed as a possibility of application [2]. Among the advantages of using piezopolymers for vibrational energy harvesting we can remember that they are ductile, resilient to shock, deformable and lightweight. In this work we demonstrate the feasibility of using magnetostrictive Fe-rich magnetic amorphous alloys/piezoelectric PVDF sandwich-type laminated ME devices as energy harvesters. A very simple experimental set-up will show how these laminates can extract energy, in amounts of μW, from an external AC field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento Ciência e Engenharia de Polímeros e Compósitos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increase in life expectancy with a decrease in birth rates is contributing to the ageing of the European population. This phenomenon, coupled with greater awareness of the quality of life, the need to have cost-efficient assistive care, the intention of people to live independently in their homes, and the technological developments in recent decades, have contributed to the emergence of the concept of ambient assisted living (AAL). AAL solutions aim to provide healthy and safe ageing to users through promoting independence in performing daily activities and interacting with technology, taking into consideration the deterioration of the users’ capabilities and the reduced costs of the solutions. In this chapter, AAL developments of monitoring activities of daily living (ADLs) and participation in a virtual community with the selected stakeholders are introduced, their roadmap with the expected technological developments are described, and the expected impact of these solutions on the end users of the developed solutions are discussed. This enables a real user guidance structure that represents the different needs and limitations of each user, presenting a highly structured project based on personas and possible solutions for them. The AAL4ALL Ambient Assisted Living for All (ALL4ALL) project is considered here as a case study to analyze and illustrate the ALL concepts discussed in this chapter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Methods: Nineteen right eyes from 19 myopic patients (average central M ± SD = −2.67 ± 1.66 D) aged 20–27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D®) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. Results: For the naked eye, refractive pattern (M, J0 and J45) across the central 60◦ of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Conclusion: Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research of stereotactic apparatus to guide surgical devices began in 1908, yet a major part of today's stereotactic neurosurgeries still rely on stereotactic frames developed almost half a century ago. Robots excel at handling spatial information, and are, thus, obvious candidates in the guidance of instrumentation along precisely planned trajectories. In this review, we introduce the concept of stereotaxy and describe a standard stereotactic neurosurgery. Neurosurgeons' expectations and demands regarding the role of robots as assistive tools are also addressed. We list the most successful robotic systems developed specifically for or capable of executing stereotactic neurosurgery. A critical review is presented for each robotic system, emphasizing the differences between them and detailing positive features and drawbacks. An analysis of the listed robotic system features is also undertaken, in the context of robotic application in stereotactic neurosurgery. Finally, we discuss the current perspective, and future directions of a robotic technology in this field. All robotic systems follow a very similar and structured workflow despite the technical differences that set them apart. No system unequivocally stands out as an absolute best. The trend of technological progress is pointing toward the development of miniaturized cost-effective solutions with more intuitive interfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proceedings da AUTEX 2015, Bucareste, Roménia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ICEIM – International Conference in Entrepreneurship and Innovation Management, Roma, 17-18 de setembro de 2015.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia e Gestão de Sistemas de Informação

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia e Gestão de Sistemas de Informação

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências da Educação (Especialidade de Tecnologia Educativa)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Programa Doutoral em Líderes para as Indústrias Tecnológicas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente investigação desenvolveu uma análise profunda do setor da distribuição farmacêutica, no período compreendido entre 2000 e 2009, procurando identificar as possíveis relações de interdependência entre o meio envolvente e as opções de estratégia das empresas que constituíram a amostra de estudo e entre as referidas opções de estratégia e as estruturas e o desempenho dessas empresas. A dinâmica do mercado do medicamento na economia nacional, com um valor de 3,2 mil milhões de euros anuais (Infarmed, 2010), apresenta um impacto significativo na esperança de vida e na qualidade de vida dos cidadãos. Segundo a OCDE, os produtos farmacêuticos são responsáveis por quase um quinto de todos os gastos com saúde, em média, nos países da OCDE. Neste contexto, a distribuição farmacêutica representa uma componente crítica. A disponibilização de medicamentos em ambulatório num curto espaço de tempo só é possível devido a uma estrutura logística com características muito específicas. A qualidade do armazenamento e do transporte dos medicamentos desde a saída dos laboratórios até à chegada às farmácias é rigorosamente monitorizada e controlada. O setor da distribuição farmacêutica assume assim uma postura elementar na cadeia do medicamento, contribuindo para a melhoria da qualidade do sistema de saúde que se tem vindo a verificar nas últimas décadas e prestando um serviço com valor para a comunidade, uma vez que se compromete a assegurar um adequado e contínuo fornecimento de medicamentos para que as necessidades dos doentes e das populações em geral sejam satisfeitas. As alterações verificadas ao longo dos últimos anos estimularam a dinâmica concorrencial entre os diferentes agentes neste mercado, bastante regulamentado e com elevado entrosamento financeiro com o Estado, o que obrigou a rápidas mudanças. Neste contexto, a sobrevivência das empresas, o seu crescimento e a sua perenidade futura têm constituído um desafio abordado de forma diversa por cada empresa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doctoral Thesis in Information Systems and Technologies Area of Information Systems and Technology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To determine whether the use of 3-dimensional (3D) imaging translates into a better surgical performance of naïve urologic laparoscopic surgeons during pyeloplasty (PY) and partial nephrectomy (PN) procedures. Materials and Methods Eighteen surgeons without any previous laparoscopic experience were randomly assigned to perform PY and PN in a porcine model using initially 2-dimensional (2D) and 3D laparoscopy. A surgical performance score was rated by an "expert" tutor through a modified 5-item global rating scale contemplating operative field view, bimanual dexterity, efficiency, tissue handling, and autonomy. Overall surgical time, complications, subjective perception of participating surgeons, and inconveniences related to the 3D vision were recorded. Results No difference in terms if operative time was found between 2D or 3D laparoscopy for both the PY (P =.51) and the PN (P =.28) procedures. A better rate in terms of surgical performance score was noted by the tutors when the study participants were using 3D vs 2D, for both PY (3.6 [0.8] vs 3.0 [0.4]; P =.034) and PN (3.6 [0.51] vs 3.15 [0.63]; P =.001). No complications occurred in any of the procedures. Most (77.2%) of the participating na??ve laparoscopic surgeons had the perception that 3D laparoscopy was overall easier than 2D. Headache (18.1%), nausea (18.1%), and visual disturbance (18.1%) were the most common issues reported by the surgeons during 3D procedures. Conclusion Despite the absence of translation in a shorter operative time, the use of 3D technology seems to facilitate the surgical performance of naive surgeons during laparoscopic kidney procedures on a porcine model.