963 resultados para Subpixel precision
Resumo:
A simple, rapid, and precise amperometric method for quantification of N-methylcarbamate pesticides in water samples and phytopharmaceuticals is presented. Carbofuran and fenobucarb are the target analytes. The method is developed in flow conditions providing the anodic oxidation of phenolic-based compounds formed after alkaline hydrolysis. Optimization of instrumental and chemical variables is presented. Under the optimal conditions, the amperometric signal is linear for carbofuran and fenobucarb concentrations over the range of 1.0*10-7 to 1.0*10-5 molL-1, with a detection limit of about 2 ngmL-1. The amperometric method is successfully applied to the analysis of spiked environmental waters and commercial formulations. The proposed method allows 90 samples to be analysed per hour, using 500 mL of sample, and producing wastewaters of low toxicity. The proposed method permits determinations at the mgL 1 level and offers advantages of simplicity, accuracy, precision, and applicability to coloured and turbid samples, and automation feasibility.
Resumo:
Growing concern about the contamination of wastewaters by antibiotics demands fast but sensitive analytical methodologies, for the screening of a large number of samples. The purpose of this work was to develop a simple methodology, using direct injection of the samples, by HPLC with diode array detection (DAD), for a multiresidue analysis of five antibiotics of different classes. Wastewater from an urban water treatment plant was selected as a model to study possible coelution of interfering compounds. The linearity interval ranged from 40 to 400 µg/L for amoxicillin (Amox), metronidazole (Metro), cefazolin (Cefa), and chloramphenicol (Chloram) and from 20 to 200 µg/L for sulfamethoxazole (Sulfa), with LODs lower than 14 µg/L. Repeatability, expressed by the CV of six repeated injections, ranged from 1 to 8%, while the intermediate precision varied between 2 and 11%. The recovery ranged from 90 to 109%. This method enables the fast screening of a large number of samples, with an expanded uncertainty in the 1–22% range. The advantage of the proposed method is to significantly reduce the number of samples to be analyzed by more complex methods.
Resumo:
The present paper describes a procedure to isolate volatiles from rock-rose (Cistus ladanifer L.) using simultaneous distillation–extraction (SDE). High-value volatile compounds (HVVC) were selected and the influence of the extraction conditions investigated. The effect of the solvent nature and extraction time on SDE efficiency was studied. The best performance was achieved with pentane in 1 h operation. The extraction efficiencies ranged from 65% to 85% and the repeatability varied between 4% and 6% (as a CV%). The C. ladanifer SDE extracts were analysed by headspace solid phase microextraction (HS-SPME) followed by gas chromatography with flame ionization detection (GC-FID). The HS-SPME sampling conditions such as fiber coating, temperature, ionic strength and exposure time were optimized. The best results were achieved with an 85 µm polyacrylate fiber for a 60 min headspace extraction at 40ºC with 20% (w/v) of NaCl. For optimized conditions the recovery was in average higher than 90% for all compounds and the intermediate precision ranged from 4 to 9% (as CV %). The volatiles α-pinene (22.2 mg g−1 of extract), 2,2,6-trimethylcyclohexanone (6.1 mg g−1 of extract), borneol (3.0 mg g−1 of extract) and bornyl acetate (3.9 mg g−1 of extract) were identified in the SDE extracts obtained from the fresh plant material.
Resumo:
The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.
Resumo:
A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.
Resumo:
Aflowinjection squarewave cathodic stripping voltammetric method has been developed for the determination of sertraline in a pharmaceutical preparation. The method shows linearity between peak current intensity and sertraline concentration for the interval between 0.20×10−6 and 1.20×10−6 mol L−1. Limits of detection and quantification were found to be 1.5×10−7 and 5.0×10−7 mol L−1, respectively. Up to 70 samples per hour can be analysed with a good precision (R.S.D. = 2.5%). The proposed method was successfully applied to the determination of sertraline in a commercial product. In the voltammetric determination of sertraline in flow, a high sample rate is obtained at reduced costs, opening the possibility to compete with the chromatographic methods generally used for this analysis.
Resumo:
Phenol is a toxic compound present in a wide variety of foundry resins. Its quantification is important for the characterization of the resins as well as for the evaluation of free contaminants present in foundry wastes. Two chromatographic methods, liquid chromatography with ultraviolet detection (LC-UV) and gas chromatography with flame ionization detection (GC-FID), for the analysis of free phenol in several foundry resins, after a simple extraction procedure (30 min), were developed. Both chromatographic methods were suitable for the determination of phenol in the studied furanic and phenolic resins, showing good selectivity, accuracy (recovery 99–100%; relative deviations <5%), and precision (coefficients of variation <6%). The used ASTM reference method was only found to be useful in the analysis of phenolic resins, while the LC and GC methods were applicable for all the studied resins. The developed methods reduce the time of analysis from 3.5 hours to about 30 min and can readily be used in routine quality control laboratories.
Resumo:
A procedure for the determination of seven indicator PCBs in soils and sediments using microwave-assisted extraction (MAE) and headspace solid-phase microextraction (HS-SPME) prior to GC-MS/MS is described. Optimization of the HS-SPME was carried out for the most important parameters such as extraction time, sample volume and temperature. The adopted methodology has reduced consumption of organic solvents and analysis runtime. Under the optimized conditions, the method detection limit ranged from 0.6 to 1 ng/g when 5 g of sample was extracted, the precision on real samples ranged from 4 to 21% and the recovery from 69 to 104%. The proposed method, which included the analysis of a certified reference material in its validation procedure, can be extended to several other PCBs and used in the monitoring of soil or sediments for the presence of PCBs.
Resumo:
The electrochemical behaviour of the pesticide metam (MT) at a glassy carbon working electrode (GCE) and at a hanging mercury drop electrode (HMDE) was investigated. Different voltammetric techniques, including cyclic voltammetry (CV) and square wave voltammetry (SWV), were used. An anodic peak (independent of pH) at +1.46 V vs AgCl/Ag was observed in MTaqueous solution using the GCE. SWV calibration curves were plotted under optimized conditions (pH 2.5 and frequency 50 Hz), which showed a linear response for 17–29 mg L−1. Electrochemical reduction was also explored, using the HMDE. A well defined cathodic peak was recorded at −0.72 V vs AgCl/ Ag, dependent on pH. After optimizing the operating conditions (pH 10.1, frequency 150 Hz, potential deposition −0.20 V for 10 s), calibration curves was measured in the concentration range 2.5×10−1 to 1.0 mg L−1 using SWV. The electrochemical behaviour of this compound facilitated the development of a flow injection analysis (FIA) system with amperometric detection for the quantification of MT in commercial formulations and spiked water samples. An assessment of the optimal FIA conditions indicated that the best analytical results were obtained at a potential of +1.30 V, an injection volume of 207 μL and an overall flow rate of 2.4 ml min−1. Real samples were analysed via calibration curves over the concentration range 1.3×10−2 to 1.3 mg L−1. Recoveries from the real samples (spiked waters and commercial formulations) were between 97.4 and 105.5%. The precision of the proposed method was evaluated by assessing the relative standard deviation (RSD %) of ten consecutive determinations of one sample (1.0 mg L−1), and the value obtained was 1.5%.
Resumo:
Amulti-residue methodology based on a solid phase extraction followed by gas chromatography–tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC–MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness.
Resumo:
Bread is consumed worldwide by man, thus contributing to the regular ingestion of certain inorganic species such as chloride. It controls the blood pressure if associated to a sodium intake and may increase the incidence of stomach ulcer. Its routine control should thus be established by means of quick and low cost procedures. This work reports a double- channel flow injection analysis (FIA) system with a new chloride sensor for the analysis of bread. All solutions are prepared in water and necessary ionic strength adjustments are made on-line. The body of the indicating electrode is made from a silver needle of 0.8 mm i.d. with an external layer of silver chloride. These devices were constructed with different lengths. Electrodes of 1.0 to 3.0 cm presented better analytical performance. The calibration curves under optimum conditions displayed Nernstian behaviour, with average slopes of 56 mV decade-1, with sampling rates of 60 samples h-1. The method was applied to analyze several kinds of bread, namely pão de trigo, pão integral, pão de centeio, pão de mistura, broa de milho, pão sem sal, pão meio sal, pão-de-leite, and pão de água. The accuracy and precision of the potentiometric method were ascertained by comparison to a spectrophotometric method of continuous segmented flow. These methods were validated against ion-chromatography procedures.
Resumo:
The Quinone outside Inhibitors (QoI) are one of the most important and recent fungicide groups used in viticulture and also allowed by Integrated Pest Management. Azoxystrobin, kresoxim-methyl and trifloxystrobin are the main active ingredients for treating downy and powdery mildews that can be present in grapes and wines. In this paper, a method is reported for the analysis of these three QoI-fungicides in grapes and wine. After liquid–liquid extraction and a clean-up on commercial silica cartridges, analysis was by isocratic HPLC with diode array detection (DAD) with a run time of 13 min. Confirmation was by solid-phase micro-extraction (SPME), followed by GC/MS determination. The main validation parameters for the three compounds in grapes and wine were a limit of detection up to 0.073mg kg-1, a precision not exceeding 10.0% and an average recovery of 93% ±38.
Resumo:
A norfloxacina e o trimetoprim são dois antibióticos antibacterianos usados para o tratamento de infeções urinárias, intestinais e respiratórias. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabolitos é assim um controlo imperioso e em muitos casos regular no tratamento de um paciente. Neste trabalho desenvolveram-se dois sensores eletroquímicos para a deteção da norfloxacina (NFX) e do trimetoprim (TMP), usando como superfície de suporte o carbono vítreo. A busca de novos materiais que conferiram maior seletividade e sensibilidade aos sistemas de deteção e por outro lado apresentem menores riscos para o paciente quando usados em dispositivos que permitam uma análise point-of-care, é especialmente importante e pode ser uma parte crucial do processo de decisão clínica. Assim, os polímeros molecularmente impresos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais avaliado. A impressão molecular é uma tecnologia capaz de produzir polímeros que incorporam as moléculas do analito e que após remoção por solventes específicos, permitem dotá-los de locais específicos de reconhecimento estereoquímico. A seleção do pirrol como polímero molecularmente impresso (MIP) permitiu construir com sucesso os sensores para doseamento dos antibióticos. A fim de aumentar a sensibilidade do método incorporou-se grafeno na superfície do elétrodo. Este material tem vindo a ser largamente utilizado devido às suas propriedades: estrutura molecular, condutividade elétrica e aumento da superfície são algumas das características que mais despertam o interesse para a sua aplicação neste projeto. Os sensores desenvolvidos foram incorporados em sistemas eletroquímicos. Os métodos voltamétricos aplicados foram a voltametria cíclica, a voltametria de onda quadrada e ainda a impedância. As condições de análise foram otimizadas no que respeita à polimerização do pirrol (concentração do polímero, número de ciclos de eletropolimerização e respetivos potenciais aplicados, tempo de incubação, solvente de remoção do analito), ao pH da solução do fármaco, à gama de concentrações dos antibióticos e aos parâmetros voltamétricos dos métodos de análise. Para cada um dos antibióticos um elétrodo não-impresso foi também preparado, usando o procedimento de polimerização mas sem a presença da molécula do analito, e foi usado como controlo. O sensor desenvolvido para o trimetoprim foi usado no doseamento do fármaco em amostras de urina. As amostras foram analisadas sem qualquer diluição, apenas foram centrifugadas para remoção de proteínas e algum interferente. Os sensores construídos apresentaram comportamento linear na gama de concentrações entre 102 e 107 mol/L. Os resultados mostram boa precisão (desvios padrão inferiores a 11%) e os limites de deteção foram de 8,317 e 1,307 mol/L para a norfloxacina e o trimetoprim, respetivamente. Para validação do método foram ainda efetuados ensaios de recuperação tendo obtido valores superiores a 94%.
Resumo:
Over the last few years, there has been a growing concern about the presence of pharmaceuticals in the environment. The main objective of this study was to develop and validate an SPE method using surface response methodology for the determination of ibuprofen in different types of water samples. The influence of sample pH and sample volume on the ibuprofen recovery was studied. The effect of each studied independent variable is pronounced on the dependent variable (ibuprofen recovery). Good selectivity, extraction efficiency, and precision were achieved using 600 mL of sample volume with the pH adjusted to 2.2. LC with fluorescence detection was employed. The optimized method was applied to 20 water samples from the North and South of Portugal.
Resumo:
Relatório do Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações