578 resultados para Rigid Contact Lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within the Australian higher education sector, institutions are required to evaluate teaching, units and courses to assure the quality of the student learning experience, however with hardly any regulatory parameters guiding institutions, and with disparate practices, there are few opportunities to benchmakr across institutions or the sector. QUT has received interest and requests from national and international universities on accessing Reframe: QUT's Evaluation Framework.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose to evaluate the effects of the wearer’s pupil size and spherical aberration on visual performance with centre-near, aspheric multifocal contact lenses (MFCLs). The advantage of binocular over monocular vision was also investigated. Methods Twelve young volunteers, with an average age of 27±5 years, participated in the study. LogMAR Visual Acuity (VA) was measured under cycloplegia for a range of defocus levels (from +3.0 to -3.0D, in 0.5D steps) with no correction and with three aspheric MFCLs (Air Optix Aqua Multifocal, Ciba Vision, Duluth, GA, US) with a centre-near design, providing correction for “Low”, “Med” and “High” near demands. Measurements were performed for all combinations of the following conditions: i) artificial pupils of 6mm and 3mm diameter, ii) binocular and monocular (dominant eye) vision. Depth-of-focus (DOF) was calculated from the VA vs. defocus curves. Ocular aberrations under cycloplegia were measured using iTrace. Results VA at -3.0D defocus (simulating near performance) was statistically higher for the 3mm than for the 6mm pupil (p=0.006), and for binocular rather than for monocular vision (p<0.001). Similarly, DOF was better for the 3mm pupil (p=0.002) and for binocular viewing conditions (p<0.001, ANOVA). Both VA at –3.0D defocus and DOF increased as the “addition” of the MFCL correction increased. Finally, with the centre-near MFCLs a linear correlation was found between VA at –3.0D defocus and the wearer’s ocular spherical aberration (R2=0.20 p<0.001 for 6mm data), with the eyes exhibiting the higher positive spherical aberration experiencing lower VAs. By contrast, no correlation was found between VA and spherical aberration at 0.00D defocus (distance vision). Conclusions Both near VA and depth-of-focus improve with these MFCLs, with the effects being more pronounced for small pupils and binocular than for monocular vision. Coupling of the wearer’s ocular spherical aberration with the aberration profiles provided by MFCLs affects their functionality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the effect of any health professional contact and the types of contact new mothers received in the first 10 days post-discharge on breastfeeding rates at 3 months. This cross-sectional retrospective self-report survey was distributed to women who birthed in Queensland, Australia between 1st February and 31st May 2010 at 4–5 months postpartum. Data were collected on pregnancy, birth, postpartum care and infant feeding. Logistic regression was used to assess the relationship between health professional contact and breastfeeding at 3 months. Data were analysed by birthing facility sector because of significant differences between sectors in health professional contact. The study cohort consisted of 6,852 women. Women in the public sector were more likely to be visited at home than women birthing in the private sector. Any health professional contact (AOR 1.65 99 % CI 0.98–2.76 public sector, AOR 0.78 99 % CI 0.59–1.03 private sector) and home visits (AOR 1.50 99 % CI 0.89–2.54 public sector, AOR 0.80 99 % CI 0.46–1.39 private sector) were not associated with breastfeeding at 3 months in either sector. A telephone call (AOR 2.07 99 % CI 1.06–4.03) or visit to a general practitioner (GP) (AOR 1.83 99 % CI 1.04–3.21) increased the odds of breastfeeding in public sector women. Health professional contact or home visiting in the first 10 days post-discharge did not have a significant impact on breastfeeding rates at 3 months. Post-discharge telephone contact for all women and opportunities for self-initiated clinic visits for women assessed to be at higher risk of ceasing breastfeeding may be the most effective care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lens average and equivalent refractive indices are required for purposes such as lens thickness estimation and optical modeling. We modeled the refractive index gradient as a power function of the normalized distance from lens center. Average index along the lens axis was estimated by integration. Equivalent index was estimated by raytracing through a model eye to establish ocular refraction, and then backward raytracing to determine the constant refractive index yielding the same refraction. Assuming center and edge indices remained constant with age, at 1.415 and 1.37 respectively, average axial refractive index increased (1.408 to 1.411) and equivalent index decreased (1.425 to 1.420) with age increase from 20 to 70 years. These values agree well with experimental estimates based on different techniques, although the latter show considerable scatter. The simple model of index gradient gives reasonable estimates of average and equivalent lens indices, although refinements in modeling and measurements are required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the study of the effect on adding total peripheries and sharp edges to the Schottky contact as a hydrogen sensor. Schottky contact was successfully designed and fabricated as hexagon-shape. The contact was integrated together with zinc oxide thin film and tested towards 1% hydrogen gas. Simulations of the design were conducted using COMSOL Multiphysics to observe the electric field characteristic at the contact layer. The simulation results show higher electric field induced at sharp edges with 4.18×104 V/m. Current-voltage characteristic shows 0.27 V voltage shift at 40 μA biased current.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores how the amalgamated wisdom of East and West can instigate a wisdombased renaissance of humanistic epistemology (Rooney & McKenna, 2005) to provide a platform of harmony in managing knowledge-worker productivity, one of the biggest management challenges of the 21st century (Drucker, 1999). The paper invites further discussions from the social and business research communities on the significance of "interpretation realism" technique in comprehending philosophies of Lao Tzu Confucius and Sun Tzu (Lao/Confucius/Sun] written in "Classical Chinese." This paper concludes with a call to build prudent, responsible practices in management which affects the daily lives of many (Rooney & McKenna, 2005) in today's knowledgebased economy. Interpretation Realism will be applied to an analysis of three Chinese classics of Lao/Confucius/Sun which have been embodied in the Chinese culture for over 2,500 years. Comprehending Lao/Confucius/Sun's philosophies is the first step towards understanding Classical Chinese culture. However, interpreting Chinese subtlety in language and the yin and yang circular synthesis in their mode of thinking is very different to understanding Western thought with its open communication and its linear, analytical pattern of Aristotelian/Platonic wisdom (Zuo, 2012). Furthermore, Eastern ways of communication are relatively indirect and mediatory in culture. Western ways of communication are relatively direct and litigious in culture (Goh, 2002). Furthermore, Lao/Confucius/Sun's philosophies are difficult to comprehend as there are four written Chinese formats and over 250 dialects: Pre-classical Chinese Classical Chinese Literary Chinese and modern Vernacular Chinese Because Classical Chinese is poetic, comprehension requires a mixed approach of interpretation realism combining logical reasoning behind "word splitting word occurrences", "empathetic metaphor" and "poetic appreciation of word.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project advances the knowledge of rail wear and crack formation due to rail/wheel contact in Australian heavy-haul railway lines. This comprehensive study utilised numerous techniques including: simulation using a twin-disk test-rig, scanning electron microscope particle analysis and finite element modeling for material failure prediction. Through this work, new material failure models have been developed which may be used to predict the lifetime and reliability of materials undergoing severe contact conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The aim of this study is to assess the refractive and visual outcomes following cataract surgery and implantation of the AcrySof IQ Toric SN6AT2 intraolcular lens (IOL) (Alcon Laboratories, Inc) in patients with low corneal astigmatism. Materials and Methods A retrospective, consecutive, single surgeon series of ninety-eight eyes of 88 patients following cataract surgery and implantation of the AcrySof IQ Toric SN6AT2 IOL in eyes with low preoperative corneal astigmatism. Postoperative measurements were obtained at one month post surgery. Main outcome measures were monocular distance visual acuity and residual refractive astigmatism. Results The mean preoperative corneal astigmatic power vector (APV) was 0.38 ± 0.09 D. Following surgery and implantation of the toric IOL, mean postoperative refractive APV was 0.13 ± 0.10 D. Mean postoperative distance uncorrected visual acuity (UCVA) was 0.08 ± 0.09 logMAR. Postoperative spherical equivalent refraction (SER) resulted in a mean of - 0.23 ± 0.22 D, with 96% of eyes falling within 0.50 D of the target SER. Conclusions The AcrySof IQ Toric SN6AT2 IOL is a safe and effective option for eyes undergoing cataract surgery with low amounts of preoperative corneal astigmatism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The insulated rail joint (IRJ) is an essential component in a track circuit that controls the signaling system. Failure of IRJs leads to improper functioning of the signals,with potential for catastrophic results. Therefore, IRJs are regarded as safety-critical sections of rail network; hence, all of their components must be maintained in pristine design condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Health promotion progresses a social justice and empowerment agenda and thus emphasises working with people to increase their control over their health. Certainly, Australia has experienced much success in this endeavour and is internationally recognised as a leader. However, health promotion has failed Indigenous Australians; a fact that is echoed in the health outcomes that ironically provide us with the “moral imperative” to act. Further investigation has also revealed health promotion’s foundation in colonial imaginings. Thus, this paper calls for the culture of health promotion to be examined as a risk factor for poor Indigenous health. To complement this call, this paper presents findings of an ethnographic study of Indigenous health promotion practice, undertaken from a postcolonial and critical whiteness framework. These findings provide a narrative of strength and innovative approaches, highlighting the value of Indigenous knowledge. These findings also contradict the biomedical tendency to construct culture as illness-producing. More broadly, this study’s findings entail important lessons for health promotion to consider, if it is to move beyond the rhetoric, to truly increase people’s control over their health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have shown that the human lens contains glycerophospholipids with ether linkages. These lipids differ from conventional glycerophospholipids in that the sn-1 substituent is attached to the glycerol backbone via an 1-O-alkyl or an 1-O-alk-1'-enyl ether rather than an ester bond. The present investigation employed a combination of collision-induced dissociation (CID) and ozone-induced dissociation (OzID) to unambiguously distinguish such 1-O-alkyl and 1-O-alk-1'-enyl ethers. Using these methodologies the human lens was found to contain several abundant 1-O-alkyl glycerophos-phoethanolamines, including GPEtn(16:0e/9Z-18:1), GPEtn(11Z-18:1e/9Z-18:1), and GPEtn(18:0e/9Z-18:1), as well as a related series of unusual 1-O-alkyl glycerophosphoserines, including GPSer(16:0e/9Z-18:1), GPSer(11Z-18:1e/9Z-18:1), GPSer(18:0e/9Z-18:1) that to our knowledge have not previously been observed in human tissue. Isomeric 1-O-alk-1'-enyl ethers were absent or in low abundance. Examination of the double bond position within the phospholipids using OzID revealed that several positional isomers were present, including sites of unsaturation at the n-9, n-7, and even n-5 positions. Tandem CID/OzID experiments revealed a preference for double bonds in the n-7 position of 1-O-ether linked chains, while n-9 double bonds predominated in the ester-linked fatty acids [e.g., GPEtn(11Z-18:1e/9Z-18:1) and GPSer(11Z-18:1e/9Z-18:1)]. Different combinations of these double bond positional isomers within chains at the sn-1 and sn-2 positions point to a remarkable molecular diversity of ether-lipids within the human lens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. Phospholipids are a major component of lens fiber cells and influence the activity of membrane proteins. Previous investigations of fatty acid uptake by the lens are limited. The purpose of the present study was thus to determine whether exogenous fatty acids could be taken up by the rat lens and incorporated into molecular phospholipids. METHODS. Lenses were incubated with fluorescently labeled palmitic acid and then analyzed by confocal microscopy. Concurrently, lenses incubated with either fluorescently labeled palmitic acid or the more physiologically relevant (13)C(18)-oleic acid were sectioned into nuclear and cortical regions and analyzed by highly sensitive and structurally selective electrospray ionization tandem mass spectrometry techniques. RESULTS. The detection of fluorescently labeled palmitic acid, even after 16 hours of incubation, was limited to approximately the outer 25% to 30% of the rat lens. Mass spectrometry also revealed the presence of free (13)C(18)-oleic acid in the cortex but not the nucleus. No evidence could be found for incorporation of fluorescently labeled palmitic acid into phospholipids; however, a low level of (13)C(18)-oleic acid incorporation into phosphatidylethanolamine (PE), specifically PE (PE 16:0/(13)C(18) 18:1) was detected in the lens cortex after 16 hours. CONCLUSIONS. These data demonstrate that uptake of exogenous (e.g., dietary fatty acids) by the lens and their incorporation into phospholipids is minimal, most likely occurring only during de novo synthesis in the outermost region of the lens. This finding adds support to the hypothesis that once synthesized there is no active remodeling or turnover of fiber cell phospholipids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dietary fatty acids are known to influence the phospholipid composition of many tissues in the body, with lipid turnover occurring rapidly. The aim of this study was to investigate whether changes in the fatty acid composition of the diet can affect the phospholipid composition of the lens. Male Sprague-Dawley rats were fed three diets with distinct profiles in both essential and non-essential fatty acids. After 8 weeks, lenses and skeletal muscle were removed, and the lenses sectioned into nuclear and cortical regions. In these experiments, the lens cortex was synthesised during the course of the variable lipid diet. Phospholipids were then identified by electrospray ionisation tandem mass spectrometry, and quantified via the use of internal standards. The phospholipid compositions of the nuclear and cortical regions of the lens differed slightly between the two regions, but comparison of the equivalent regions across the diet groups showed remarkable similarity. In contrast, the phospholipid composition of skeletal muscle (medial gastrocnemius) in these rats varied significantly. This study provides the first direct evidence to show that the phospholipid composition of the lens is tightly regulated and thus appears to be independent of diet. As phospholipids determine membrane fluidity and influence the activity and function of integral membrane proteins, regulation of their composition may be important for the function of the lens. Crown Copyright (C) 2008 Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The lipid composition of the human lens is distinct from most other tissues in that it is high in dihydrosphingomyelin and the most abundant glycerophospholipids in the lens are unusual 1-O-alkyl-ether linked phosphatidylethanolamines and phosphatidylserines. In this study, desorption electrospray ionization (DESI) mass spectrometry-imaging was used to determine the distribution of these lipids in the human lens along with other lipids including, ceramides, ceramide-1-phosphates, and lyso 1-O-alkyl ethers. To achieve this, 25 μm lens slices were mounted onto glass slides and analyzed using a linear ion-trap mass spectrometer equipped with a custom-built, 2-D automated DESI source. In contrast to other tissues that have been previously analyzed by DESI, the presence of a strong acid in the spray solvent was required to desorb lipids directly from lens tissue. Distinctive distributions were observed for [M + H]+ ions arising from each lipid class. Of particular interest were ionized 1-O-alkyl phosphatidylethanolamines and phosphatidylserines, PE (18:1e/18:1), and PS (18:1e/18:1), which were found in a thin ring in the outermost region of the lens. This distribution was confirmed by quantitative analysis of lenses that were sectioned into four distinct regions (outer, barrier, inner, and core), extracted and analyzed by electrospray ionization tandem mass spectrometry. DESI-imaging also revealed a complementary distribution for the structurally-related lyso 1-O-alkyl phosphatidylethanolamine, LPE (18:1e), which was localized closer to the centre of the lens. The data obtained in this study indicate that DESI-imaging is a powerful tool for determining the spatial distribution of human lens lipids. © 2010 American Society for Mass Spectrometry.