768 resultados para Retest Reliability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the psychometric performance of the Child Health Questionnaire (CHQ) in children with cerebral palsy (CP).
Method: 818 parents of children with CP, aged 8–12 from nine regions of Europe completed the CHQ (parent form 50 items). Functional abilities were classified using the five-level Gross Motor Function Classification Scheme (Levels I–III as ambulant; Level IV–V as nonambulant CP).
Results: Ceiling effects were observed for a number of subscales and summary scores across all Gross Motor Function Classification System levels, whilst floor effects occurred only in the physical functioning scale (Level V CP). Reliability was satisfactory overall. Confirmatory factor analysis (CFA) revealed a seven-factor structure for the total sample of children with CP but with different factor structures for ambulant and nonambulant children.
Conclusion: The CHQ has limited applicability in children with CP, although with judicious use of certain domains for ambulant and nonambulant children can provide useful and comparable data about child health status for descriptive purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electronprobe microanalysis is now widely adopted in tephra studies as a technique for determining the major element geochemistry of individual glass shards. Accurate geochemical characterization is crucial for enabling robust tephra-based correlations; such information may also be used to link the tephra to a specific source and often to a particular eruption. In this article, we present major element analyses for rhyolitic natural glass standards analysed on three different microprobes and the new JEOL FEGSEM 6500F microprobe at Queen’s University Belfast. Despite the scatter in some elements, good comparability is demonstrated among data yielded from this new system, the previous Belfast JEOL-733 Superprobe, the JEOL-8200 Superprobe (Copenhagen) and the existing long-established microprobe facility in Edinburgh. Importantly, our results show that major elements analysed using different microprobes and variable operating conditions allow two high-silica glasses to be discriminated accurately.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The LifeShirt is a novel ambulatory monitoring system that records cardio respiratory measurements outside the laboratory. Validity and reliability of cardiorespiratory measurements recorded by the LifeShirt were assessed and two methods of calibrating the LifeShirt were compared. Participants performed an incremental treadmill test and a constant work rate test (65% peak oxygen uptake) on four occasions (>48 In apart) and wore the LifeShirt, COSMED system and Polar Sport Tester simultaneously. The LifeShirt was calibrated using two methods: comparison to a spirometer; and 800 ml fixed-volume bag. Ventilation, respiratory rate, expiratory time and heart rate recorded by the LifeShirt were compared to measurements recorded by laboratory equipment. Sixteen adults participated (6M: 10F); mean (SD) age 23.1 (2.9) years. Agreement between the LifeShirt and laboratory equipment was acceptable. Agreement for ventilation was improved by calibrating the LifeShirt using a spirometer. Reliability was similar for the LifeShirt and the laboratory equipment. This study suggests that the LifeShirt provides a valid and reliable method of ambulatory monitoring. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The blood pressure waveform is modified on distal propagation by phenomena such as dispersion, reflection and the state of the arterial compliance. The consequent effects are amplification and narrowing of the wave, with an increased systolic, reduced diastolic and essentially unaltered mean blood pressure. The Finapres measures the peripheral pressure using the volume clamp principle; it has not been validated under altered physiological conditions and during pharmacodynamic interventions. We studied simultaneous Finapres and brachial blood pressures (using a conventional oscillometric sphygmomanometer—Vitalmap) in ten normal volunteers at rest, and during dynamic exercise and a cold pressor test. The effects of pharmacodynamic intervention were examined following beta-adrenoceptor blockade with propranolol (160 mg) or beta-adrenoceptor modulation with the beta-adrenoceptor partial agonist celiprolol (400 mg). The Finapres systolic pressure was significantly higher than the brachial value during all three test states. The difference between the systolic pressures measured by the two devices was shown to increase significantly during the cold pressor test, but not during dynamic (supine bicycle) exercise. The Finapres diastolic pressure was significantly higher than the Vitalmap value during exercise and the cold pressor test. The differences between the two methods increased significantly over time. Beta-adrenergic blockade with propranolol or modulation with celiprolol had no significant interaction with the pressure differences between the Finapres and Vitalmap techniques. The results would support the view that the Finapres can provide blood pressure information which is robust under most circumstances. Although this pharmacodynamic intervention did not alter the relationship between the peripheral and central blood pressure, it is important to note that this dynamic relationship is sensitive to circulatory loading conditions and wave transmission characteristics; it is possible that the Finapres could be less reliable in clinical settings where potent vasoactive agents were being administered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tissue microarrays allow high throughput molecular profiling of diagnostic or predictive markers in cancer specimens and rapid validation of novel potential candidates identified from genomic and proteomic analyses in a large number of tumor samples. To validate the use of tissue microarray technology for all the main biomarkers routinely used to decide breast cancer prognostication and postsurgical adjuvant therapy, we constructed a tissue microarray from 97 breast tumors, with a single 0.6 mm core per specimen. Inummostaining; of tissue microarray sections and conventional full sections of each tumor were performed using well-characterized prognostic markers (estrogen receptor ER, progesterone receptor PR and c-erbB2). The full section versus tissue microarray concordance for these stains was 97% for ER, 98% for PR, and 97% for c-erbB2, respectively, with a strong statistical association (kappa value more than 0.90). Fluorescence in situ hybridization analysis for HER-2/neu gene amplification from the single-core tissue microarray was technically successful in about 90% (87/97) of the cases, with a concordance of 95% compared with parallel analyses with the full sections. The correlation with other pathological parameters was not significantly different between full-section and array-based results. It is concluded that the constructed tissue microarray with a single core per specimen ensures full biological representativeness to identify the associations between biomarkers and clinicopathological parameters, with no significant associated sampling bias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Inappropriate prescribing is a well-documented problem in older people. The new screening tools, STOPP (Screening Tool of Older Peoples' Prescriptions) and START (Screening Tool to Alert doctors to Right Treatment) have been formulated to identify potentially inappropriate medications (PIMs) and potential errors of omissions (PEOs) in older patients. Consistent, reliable application of STOPP and START is essential for the screening tools to be used effectively by pharmacists. OBJECTIVE: To determine the interrater reliability among a group of clinical pharmacists in applying the STOPP and START criteria to elderly patients' records. METHODS: Ten pharmacists (5 hospital pharmacists, 5 community pharmacists) were given 20 patient profiles containing details including the patients' age and sex, current medications, current diagnoses, relevant medical histories, biochemical data, and estimated glomerular filtration rate. Each pharmacist applied the STOPP and START criteria to each patient record. The PIMs and PEOs identified by each pharmacist were compared with those of 2 academic pharmacists who were highly familiar with the application of STOPP and START. An interrater reliability analysis using the k statistic (chance corrected measure of agreement) was performed to determine consistency between pharmacists. RESULTS: The median ? coefficients for hospital pharmacists and community pharmacists compared with the academic pharmacists for STOPP were 0.89 and 0.88, respectively, while those for START were 0.91 and 0.90, respectively. CONCLUSIONS: Interrater reliability of STOPP and START tools between pharmacists working in different sectors is good. Pharmacists working in both hospitals and in the community can use STOPP and START reliably during their everyday practice to identify PIMs and PEOs in older patients.