863 resultados para Photoelectric tracking
Resumo:
Swimming fish leave wakes containing hydrodynamic and chemical traces. These traces mark their swim paths and could guide predators. We now show that nocturnal European catfish (Silurus glanis) locate a piscine prey (guppy, Poecilia reticulata) by accurately tracking its three-dimensional swim path before an attack in the absence of visible light. Wakes that were up to 10 s old were followed over distances up to 55 prey-body lengths in our setup. These results demonstrate that prey wakes remain sufficiently identifiable to guide predators, and to extend considerably the area in which prey is detectable. Moreover, wakes elicit rear attacks, which may be more difficult to detect by prey. Wake tracking may be a common strategy among aquatic predators.
Resumo:
To examine the hypothesis that surface P-selectin-positive (degranulated) platelets are rapidly cleared from the circulation, we developed novel methods for tracking of platelets and measurement of platelet function in vivo. Washed platelets prepared from nonhuman primates (baboons) were labeled with PKH2 (a lipophilic fluorescent dye), thrombin-activated, washed, and reinfused into the same baboons. Three-color whole blood flow cytometry was used to simultaneously (i) identify platelets with a mAb directed against glycoprotein (GP)IIb-IIIa (integrin alpha 11b beta 3), (ii) distinguish infused platelets by their PKH2 fluorescence, and (iii) analyze platelet function with mAbs. Two hours after infusion of autologous thrombin-activated platelets (P-selectin-positive, PKH2-labeled), 95 +/- 1% (mean +/- SEM, n = 5) of the circulating PKH2-labeled platelets had become P-selectin-negative. Compared with platelets not activated with thrombin preinfusion, the recovery of these circulating PKH2-labeled, P-selectin-negative platelets was similar 24 h after infusion and only slightly less 48 h after infusion. The loss of platelet surface P-selectin was fully accounted for by a 67.1 +/- 16.7 ng/ml increase in the plasma concentration of soluble P-selectin. The circulating PKH2-labeled, P-selectin-negative platelets were still able to function in vivo, as determined by their (i) participation in platelet aggregates emerging from a bleeding time wound, (ii) binding to Dacron in an arteriovenous shunt, (iii) binding of mAb PAC1 (directed against the fibrinogen binding site on GPIIb-IIIa), and (iv) generation of procoagulant platelet-derived microparticles. In summary, (i) circulating degranulated platelets rapidly lose surface P-selectin to the plasma pool, but continue to circulate and function; and (ii) we have developed novel three-color whole blood flow cytometric methods for tracking of platelets and measurement of platelet function in vivo.
Resumo:
Knowing how motile bacteria move near and along a solid surface is crucial to understanding such diverse phenomena as the migration of infectious bacteria along a catheter, biofilm growth, and the movement of bacteria through the pore spaces of saturated soil, a critical step in the in situ bioremediation of contaminated aquifers. In this study, a tracking microscope is used to record the three-dimensional motion of Escherichia coli near a planar glass surface. Data from the tracking microscope are analyzed to quantify the effects of bacteria-surface interactions on the swimming behavior of bacteria. The speed of cells approaching the surface is found to decrease in agreement with the mathematical model of Ramia et al. [Ramia, M., Tullock, D. L. & Phan-Tien, N. (1993) Biophys J. 65,755-778], which represents the bacteria as spheres with a single polar flagellum rotating at a constant rate. The tendency of cells to swim adjacent to the surface is shown in computer-generated reproductions of cell traces. The attractive interaction potential between the cells and the solid surface is offered as one of several possible explanations for this tendency.
Resumo:
Objetivo: O principal propósito do estudo foi pesquisar a disfunção ventricular esquerda subclínica em pacientes com lúpus eritematoso sistêmico juvenil (LESJ) através da técnica de speckle-tracking bidimensional. Foi investigada ainda uma possível correlação entre o comprometimento da deformação miocárdica e o SLEDAI-2K (Systemic Lupus Erithematosus Disease Activity Index 2000), bem como a presença de fatores de risco cardiovascular, tanto tradicionais como ligados à doença. Métodos: 50 pacientes assintomáticos do ponto de vista cardiovascular e 50 controles saudáveis (14,74 vs. 14,82 anos, p=0.83) foram avaliados pelo ecocardiograma convencional e pelo speckle-tracking bidimensional. Resultados: Apesar da fração de ejeção normal, os pacientes apresentaram redução de todos os parâmetros de deformação miocárdica longitudinal e radial, quando comparados aos controles: strain de pico sistólico longitudinal [-20,3 (-11 a -26) vs. -22 (-17,8 a -30.4) %, p < 0,0001], strain rate de pico sistólico longitudinal [-1,19 ± 0,21 vs. -1,3 ± 0,25 s-1, p=0,0005], strain rate longitudinal na diástole precoce [1,7 (0,99 a 2,95) vs. 2 (1,08 a 3,00) s-1 , p=0,0034], strain de pico sistólico radial [33,09 ± 8,6 vs. 44,36 ± 8,72%, p < 0,0001], strain rate de pico sistólico radial [1,98 ± 0,53 vs. 2,49 ± 0,68 s-1, p < 0,0001] e strain rate radial na diástole precoce [-2,31 ± 0,88 vs. -2,75 ± 0,97 s-1, p=0,02]. O strain de pico sistólico circunferencial [-23,67 ± 3,46 vs. - 24,6 ± 2,86%, p=0,43] e o strain rate circunferencial na diástole precoce [2 (0,88 a 3,4) vs. 1,99 (1,19 a 3,7) s-1, p=0,88] foram semelhantes em pacientes e controles. Apenas o strain rate de pico sistólico circunferencial [-1,5 ± 0,3 vs. -1,6 ± 0,3 s-1, p=0,036] mostrou-se reduzido no LESJ. Uma correlação negativa foi identificada entre o strain de pico sistólico longitudinal e o SLEDAI-2K (r = - 0,52; p < 0,0001) e também o número de fatores de risco cardiovascular por paciente (r = -0,32, p=0,024). Conclusões: Foi evidenciada disfunção sistólica e diastólica subclínica de ventrículo esquerdo no LESJ através da técnica de speckle-tracking bidimensional. A atividade da doença e a exposição aos fatores de risco cardiovascular provavelmente contribuíram para o comprometimento da deformação miocárdica nesses pacientes
Resumo:
The very purpose of a recruiting software program is to help the management of organizations, primarily the HR department to keep track of the job applications. An applicant tracking system can reduce an organization's overall recruitment cost, increase productivity, and raise the level of satisfaction due to faster and better completion of transactions and services. This project analyzes four software providers to discover an applicant tracking system which best suits an organization's recruiting needs. The capstone also highlights that great success an organization can be achieved by significantly improving the delivery of its recruiting services to employees, managers and applicants. The adoption of a well managed applicant tracking system can support this goal.
Resumo:
Comunicación presentada en el VII Symposium Nacional de Reconocimiento de Formas y Análisis de Imágenes, SNRFAI, Barcelona, abril 1997.
Resumo:
Comunicación presentada en la VII Conferencia de la Asociación Española para la Inteligencia Artificial, CAEPIA, Málaga, 12-14 noviembre, 1997.
Resumo:
Deformable Template models are first applied to track the inner wall of coronary arteries in intravascular ultrasound sequences, mainly in the assistance to angioplasty surgery. A circular template is used for initializing an elliptical deformable model to track wall deformation when inflating a balloon placed at the tip of the catheter. We define a new energy function for driving the behavior of the template and we test its robustness both in real and synthetic images. Finally we introduce a framework for learning and recognizing spatio-temporal geometric constraints based on Principal Component Analysis (eigenconstraints).
Resumo:
Póster presentado en OPTYKA Optical Fair 2012, Poznan, Polonia, 9-10 noviembre 2012.
Resumo:
Subpixel methods increase the accuracy and efficiency of image detectors, processing units, and algorithms and provide very cost-effective systems for object tracking. Published methods achieve resolution increases up to three orders of magnitude. In this Letter, we demonstrate that this limit can be theoretically improved by several orders of magnitude, permitting micropixel and submicropixel accuracies. The necessary condition for movement detection is that one single pixel changes its status. We show that an appropriate target design increases the probability of a pixel change for arbitrarily small shifts, thus increasing the detection accuracy of a tracking system. The proposal does not impose severe restriction on the target nor on the sensor, thus allowing easy experimental implementation.
Resumo:
Visual information is increasingly being used in a great number of applications in order to perform the guidance of joint structures. This paper proposes an image-based controller which allows the joint structure guidance when its number of degrees of freedom is greater than the required for the developed task. In this case, the controller solves the redundancy combining two different tasks: the primary task allows the correct guidance using image information, and the secondary task determines the most adequate joint structure posture solving the possible joint redundancy regarding the performed task in the image space. The method proposed to guide the joint structure also employs a smoothing Kalman filter not only to determine the moment when abrupt changes occur in the tracked trajectory, but also to estimate and compensate these changes using the proposed filter. Furthermore, a direct visual control approach is proposed which integrates the visual information provided by this smoothing Kalman filter. This last aspect permits the correct tracking when noisy measurements are obtained. All the contributions are integrated in an application which requires the tracking of the faces of Asperger children.
Resumo:
Traditional visual servoing systems do not deal with the topic of moving objects tracking. When these systems are employed to track a moving object, depending on the object velocity, visual features can go out of the image, causing the fail of the tracking task. This occurs specially when the object and the robot are both stopped and then the object starts the movement. In this work, we have employed a retina camera based on Address Event Representation (AER) in order to use events as input in the visual servoing system. The events launched by the camera indicate a pixel movement. Event visual information is processed only at the moment it occurs, reducing the response time of visual servoing systems when they are used to track moving objects.
Resumo:
Subpixel techniques are commonly used to increase the spatial resolution in tracking tasks. Object tracking with targets of known shape permits obtaining information about object position and orientation in the three-dimensional space. A proper selection of the target shape allows us to determine its position inside a plane and its angular and azimuthal orientation under certain limits. Our proposal is demonstrated both numerical and experimentally and provides an increase the accuracy of more than one order of magnitude compared to the nominal resolution of the sensor. The experiment has been performed with a high-speed camera, which simultaneously provides high spatial and temporal resolution, so it may be interesting for some applications where this kind of targets can be attached, such as vibration monitoring and structural analysis.
Resumo:
We present a targetless motion tracking method for detecting planar movements with subpixel accuracy. This method is based on the computation and tracking of the intersection of two nonparallel straight-line segments in the image of a moving object in a scene. The method is simple and easy to implement because no complex structures have to be detected. It has been tested and validated using a lab experiment consisting of a vibrating object that was recorded with a high-speed camera working at 1000 fps. We managed to track displacements with an accuracy of hundredths of pixel or even of thousandths of pixel in the case of tracking harmonic vibrations. The method is widely applicable because it can be used for distance measuring amplitude and frequency of vibrations with a vision system.
Resumo:
Tese de doutoramento, Biologia (Biologia Evolutiva), Universidade de Lisboa, Faculdade de Ciências, 2016