924 resultados para Mixing Length


Relevância:

20.00% 20.00%

Publicador:

Resumo:

By comparing the behavior of three Acromyrmex (Hymenoptera, Formicidae) species during foraging on artificial trails of different lengths, we observed the occurrence of task partitioning and its relation to the food distance from the nest. Task partitioning was verified by leaf cache formation along the trail and leaf direct transferring among workers. There was significant difference between the number of leaf fragments carried directly to the fungus chamber and those transferred direct or indirectly, via cache, depending upon the trail length. Task partitioning could be a strategy used by leaf-cutting ants that allows the workers to use food sources far from their nests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to study the length distribution of some fish species from the Protected Area of São Pedro and Analândia, State of São Paulo, Southeastern Brazil. Length distributions were correlated to environmental conditions at each sample site. For the most abundant species, length structure was compared among the streams of each basin and between basins. Differences in length structure were related to differences in growth, habitats, and even population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Pacific white shrimp, Litopenaeus vannamei (Penaeidae), represents about 95% of all Brazilian shrimp production. The Brazilian L. vannamei foundation broodstock was made up of specimens collected from different American Pacific sites, but little information was collected on the genetic structure of the broodstock. We used the fluorescence amplified fragment length polymorphism (fAFLP) method to study the genetic diversity of L. vannamei broodstock lines 03CMF1 and 03CBF1 originally produced by breeder-shrimps imported mainly from Panama and Ecuador, although wild individuals from other localities may also have been used in producing these two lines. Our results showed a total of 93 polymorphic bands ranging from 50 to 500 bp, the mean Nei's genetic diversity calculated for the total sample was 13.4% and identity and genetic distance analyses indicated high genetic homogeneity within and between both the broodstock lineages studied which suggests that they had similar genetic structure. These results may represent an important tool for the appropriate management of L. vannamei broodstocks. Copyright by the Brazilian Society of Genetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use a time-dependent dynamical mean-field-hydrodynamic model to study mixing-demixing in a degenerate fermion-fermion mixture (DFFM). It is demonstrated that with the increase of interspecies repulsion and/or trapping frequencies, a mixed state of a DFFM could turn into a fully demixed state in both three-dimensional spherically symmetric as well as quasi-one-dimensional configurations. Such a demixed state of a DFFM could be experimentally realized by varying an external magnetic field near a fermion-fermion Feshbach resonance, which will result in an increase of interspecies fermion-fermion repulsion, and/or by increasing the external trap frequencies. © 2006 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Negative effects of soil compaction have been recognized as one of the problems restricting the root system and consequently impairing yields, especially in the Southern Coastal Plain of the USA. Simulations of the root restricting layers in green house studies are necessary for the development of mechanism which alleviates soil compaction problems in these soils. The selection of three distinct bulk densities based on the standard proctor test is also an important factor to determine which bulk density restricts the root layer. The experiment was conducted to assess the root length density and root diameter of the corn (Zea mays L.) crop as a function of bulk density and water stress, characterized by the soil density (1.2; 1.4, and 1.6 g cm -3), and two levels of the water content, approximately (70 and 90% field capacity). The statistical design adopted was completely randomized design, with four replicates in a factorial pattern of (3 × 2). The PVC tubes were superimposed with an internal diameter of 20 cm with a height of 40 cm (the upper tube 20 cm, compacted and inferior tube 10 cm), the hardpan with different levels of soil compaction were located between 20 and 30 cm of the depth of the pot. Results showed that: the main effects of subsoil mechanical impedance were observed on the top layer indicating that the plants had to penetrate beyond the favorable soil conditions before root growth was affected from 3.16; 2.41 to 1.37 cm cm -3 (P<0.005). There was a significant difference at the hardpan layer for the two levels of water and 90% field capacity reduced the root growth from 0.91 to 0.60 cm cm -3 (P<0.005). The root length density and root diameter were affected by increasing soil bulk density from 1.2 to 1.6 g cm -3 which caused penetration resistance to increase to 1.4 MPa. Soil water content of 70% field capacity furnished better root growth in all the layers studied. The increase in root length density resulted in increased root volume. It can also be concluded that the effect of soil compaction impaired the root diameter mostly at the hardpan layer. Soil temperature had detrimental effect on the root growth mostly with higher bulk densities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study an ultracold and dilute superfluid Bose-Fermi mixture confined in a strictly one-dimensional (1D) atomic waveguide by using a set of coupled nonlinear mean-field equations obtained from the Lieb-Liniger energy density for bosons and the Gaudin-Yang energy density for fermions. We consider a finite Bose-Fermi interatomic strength gbf and both periodic and open boundary conditions. We find that with periodic boundary conditions-i.e., in a quasi-1D ring-a uniform Bose-Fermi mixture is stable only with a large fermionic density. We predict that at small fermionic densities the ground state of the system displays demixing if gbf >0 and may become a localized Bose-Fermi bright soliton for gbf <0. Finally, we show, using variational and numerical solutions of the mean-field equations, that with open boundary conditions-i.e., in a quasi-1D cylinder-the Bose-Fermi bright soliton is the unique ground state of the system with a finite number of particles, which could exhibit a partial mixing-demixing transition. In this case the bright solitons are demonstrated to be dynamically stable. The experimental realization of these Bose-Fermi bright solitons seems possible with present setups. © 2007 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since Ranzini suggested supplementing the SPT test with measurement of the torque required to turn the split spoon sampler after driving, many Brazilian engineers have been using this in the design of pile foundations. This paper presents a study of the rod length influence in the torque measurement. A theoretical study of material resistance considering torsion and bending in a thin wall tubular steel shaft was performed. It makes possible to conclude that the shearing tension caused by the proper weight represents less than 1% of the shearing tension caused by the turning moment. In addition, an experimental study was done with electric torquemeters fixed in a horizontal rod system. The tests were being carried out to analyze rods of one meter to twenty meters in length and the measurements were collected at the ends of each rod length verifying the efficiency data. As a result, it is possible to verify that the torque difference through rod length is lower than minimum scales of mechanical torquemeters that are used on practical engineering. Also a fact to be considered is a big torque loss for values under 20 N.m of applied torque. This way, the SPT-T is not adequate to low consistency soil. Copyright ASCE 2007.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obese insulin resistant animals and humans have shown reduced GLUT4 gene expression. Yet, in skeletal muscle, discrepancy between mRNA and protein regulation has been frequently observed, suggesting a post-transcriptional modulation. We investigated the GLUT4 expression in adipose tissue and muscle of obese 12-month-old (12-mo) rats, comparing with lean 2-month-old (2-mo) animals. Obesity was accompanied by insulin resistance, and 65% reduction (P < 0.01) in GLUT4 mRNA and protein in adipose tissue. However, in muscle, despite increased (P < 0.05) mRNA content, GLUT4 protein was unchanged. RNase H and poly(A) test assays showed a reduction (P < 0.01) of ∼80 adenines in the GLUT4 mRNA poly(A) tail of muscle from 12-mo rats, recognizing that the poly(A) tail length correlates with translation efficiency. Concluding, age related obesity of 12-mo rats involves suppression of GLUT4 expression in adipose tissue; however, in muscle, GLUT4 mRNA content increases, but with a shorter poly(A) tail, thus unchanging the protein content. © 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to survey radiographic measurement estimation in the assessment of dental implant length according to dentists' confidence. A 19-point questionnaire with closed-ended questions was used by two graduate students to interview 69 dentists during a dental implant meeting. Included were 12 questions related to over- and underestimation in three radiographic modalities: panoramic (P), conventional tomography (T), and computerized tomography (CT). The database was analyzed by Epi-Info 6.04 software and the values from two radiographic modalities, P and T, were compared using a chi2 test. The results showed that 38.24% of the dentists' confidence was in the overestimation of measurements in P, 30.56% in T, and 0% in CT. On the other hand, considering the underestimated measurements, the percentages were 47.06% in P, 33.33% in T, and 1.92% in CT. The frequency of under- and overestimation were statistically significant (chi2 = 6.32; P = .0425) between P and T. CT was the radiographic modality with higher measurement precision according to dentists' confidence. In conclusion, the interviewed dentists felt that CT was the best radiographic modality when considering the measurement estimation precision in preoperative dental implant assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the present study, 107 specimens of Atlantoraja castelnaui, 188 of A. platana, and 770 of A. cyclophora, were obtained by commercial vessels operating in Southeastern Brazil from March 2005 to April 2006. Males of A. castelnaui ranged from 17.9-111.0 cm and females from 17.4-116.0 cm total length. Males of A. platana ranged from 13.1-70.0 cm and females from 12.5-76.0 cm total length. Males of A. cyclophora ranged from 13.3-58.5 cm and females from 11.5-68.0 cm total length. Length-weight curves were sexually dimorphic in the three species. The analysis of the angular coefficient (b) demonstrated that growth (in weight) in relation to length was allometric (b>3) in males of A. castelnaui and A. platana, while isometric (b = 3) in females of these species. Conversely, growth of A. cyclphora was isometric in males, while in females it was allometric (b>3). The condition factor varied significantly throughout the year only in females of A. castelnaui.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the penetration (tags) of adhesive materials into enamel etched with phosphoric acid or treated with a self-etching adhesive, before application of a pit-and-fissure sealant. MATERIALS AND METHODS: The sample comprised six study groups with six specimens each. Before pit-and-fissure sealing with the materials Clinpro SealantTM (Groups I and II), Vitro Seal ALPHA (Groups III and IV) and Fuji II LC (Groups V and VI), the teeth in Groups I, III, and V were etched with 35% phosphoric acid for 30 seconds. Teeth in Groups II, IV, and VI received application of the self-etching adhesive Adper Prompt L-Pop. The treated teeth were sectioned buccolingually, ground to 100-microm thickness, decalcified, and analyzed by conventional light microscopy at 400x magnification. RESULTS: The teeth etched with phosphoric acid exhibited significantly greater penetration than specimens treated with self-etching adhesive. CLINICAL SIGNIFICANCE: When compared with enamel treated with a self-etching adhesive, the penetration (tags) of adhesive materials into enamel was greater when applied on enamel etched with phosphoric acid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rheology has the purpose to study the flux and deformation of materials when submitted to some tension or outer mechanical solicitation. In practice, the effective scientific field broached by rheology is restricted only to the study of homogeneous fluids behavior, in which are included eminent liquids, particles suspensions, and emulsions. The viscosity (η) and the yield stress (τ 0) are the two basic values that define the fluids' behavior. The first one is the proportionality constant that relates the shear rate (γ) with the shear stress (τ) applied, while the second indicates the minimal tension for the flowage beginning. The fluids that obey the Newton's relation - Newtonians fluids - display the constant viscosity and the null yield stress. It's the case of diluted suspensions and grate amount of the pure liquids (water, acetone, alcohol, etc.) in which the viscosity is an intrinsic characteristic that depends on temperature and, in a less significant way, pressure. The suspension, titled Cement Paste, is defined as being a mixture of water and cement with, or without, a superplasticizer additive. The cement paste has a non-Newtonian fluid behavior (pseudoplastic), showing a viscosity that varies in accord to the applied shear stress and significant deformations are obtained from a delimited yield stress. In some cases, systems can also manifest the influence of chemical additives used to modify the interactions fluid/particles, besides the introduced modifications by the presence of incorporated air. To the cement paste the rheometric rehearsals were made using the rheometer R/S Brookfield that controls shear stress and shear rate in accord to the rheological model of Herschel-Bulkley that seems to better adapt to this kind of suspension's behavior. This paper shows the results of rheometrical rehearsals on the cement paste that were produced with cements HOLCIM MC-20 RS and CPV-ARI RS with the addition of superplasticizer additives based of napthaline and polycarboxilate, with and without a constant agitation of the mixture. The obtainment of dosages of superplasticizer additives, as well as the water/cement ratio, at the cement at the fluidify rate determination, was done in a total of 12 different mixtures. It's observed that the rheological parameters seem to vary according to the cement type, the superplasticizer type, and the methodology applied at the fluidity rate determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We define by simple conditions two wide subclasses of the socalled Arnoux-Rauzy systems; the elements of the first one share the property of (measure-theoretic) weak mixing, thus we generalize and improve a counterexample to the conjecture that these systems are codings of rotations; those of the second one have eigenvalues, which was known hitherto only for a very small set of examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: This in vitro study evaluated the accuracy of primary incisor lengths determined by digital and conventional radiography compared to the actual tooth length. Methods: Twenty extracted primary maxillary incisors were mounted in acrylic blocks. Tooth length was estimated by using a straight-line measurement provided by the distance measurement tool of a digital dental imaging system (Computed Dental Radiography, Schick Technologies Inc.) and conventional E-speed film radiographs by using a digital caliper. Two operators familiar with both radiographic methods performed the estimates. The estimated tooth lengths were compared to the actual tooth lengths measured with the digital caliper. Data were statistically analyzed by Dahlberg's equation, paired t test, Pearson's correlation coefficient and ANOVA at 5% significance level. Results: There were no statistically significant differences (p = 0.85) between tooth length estimated on digital and conventional radiographs. Admitting as clinically acceptable a 0.5-mm discrepancy between the actual tooth lengths and the radiographically estimated lengths, 60% of the radiographic measurements were considered as accurate. When the acceptable difference range was 1.0 mm, the accuracy of the radiographic measurements increased to 100%. Conclusions: Digital and conventional radiography provided similar tooth length measurements and were equivalent to the actual tooth lengths.