951 resultados para Liquid phase


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The existence of a liquid-gas phase transition for hot nuclear systems at subsaturation densities is a well-established prediction of finite-temperature nuclear many-body theory. In this paper, we discuss for the first time the properties of such a phase transition for homogeneous nuclear matter within the self-consistent Green's function approach. We find a substantial decrease of the critical temperature with respect to the Brueckner-Hartree-Fock approximation. Even within the same approximation, the use of two different realistic nucleon-nucleon interactions gives rise to large differences in the properties of the critical point.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The development of liquid-crystal panels for use in commercial equipment has been aimed at improving the pixel resolution and the display efficiency. These improvements have led to a reduction in the thickness of such devices, among other outcomes, that involves a loss in phase modulation. We propose a modification of the classical phase-only filter to permit displays in VGA liquid-crystal panels with a constant amplitude modulation and less than a 2¿(PI) phase modulation. The method was tested experimentally in an optical setup.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Plasma catecholamines provide a reliable biomarker of sympathetic activity. The low circulating concentrations of catecholamines and analytical interferences require tedious sample preparation and long chromatographic runs to ensure their accurate quantification by HPLC with electrochemical detection. Published or commercially available methods relying on solid phase extraction technology lack sensitivity or require derivatization of catecholamine by hazardous reagents prior to tandem mass spectrometry (MS) analysis. Here, we manufactured a novel 96-well microplate device specifically designed to extract plasma catecholamines prior to their quantification by a new and highly sensitive ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. Processing time, which included sample purification on activated aluminum oxide and elution, is less than 1 h per 96-well microplate. The UPLC-MS/MS analysis run time is 2.0 min per sample. This UPLC-MS/MS method does not require a derivatization step, reduces the turnaround time by 10-fold compared to conventional methods used for routine application, and allows catecholamine quantification in reduced plasma sample volumes (50-250 μL, e.g., from children and mice).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Reversed phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) is the gold standard technique in bioanalysis. However, hydrophilic interaction chromatography (HILIC) could represent a viable alternative to RPLC for the analysis of polar and/or ionizable compounds, as it often provides higher MS sensitivity and alternative selectivity. Nevertheless, this technique can be also prone to matrix effects (ME). ME are one of the major issues in quantitative LC-MS bioanalysis. To ensure acceptable method performance (i.e., trueness and precision), a careful evaluation and minimization of ME is required. In the present study, the incidence of ME in HILIC-MS/MS and RPLC-MS/MS was compared for plasma and urine samples using two representative sets of 38 pharmaceutical compounds and 40 doping agents, respectively. The optimal generic chromatographic conditions in terms of selectivity with respect to interfering compounds were established in both chromatographic modes by testing three different stationary phases in each mode with different mobile phase pH. A second step involved the assessment of ME in RPLC and HILIC under the best generic conditions, using the post-extraction addition method. Biological samples were prepared using two different sample pre-treatments, i.e., a non-selective sample clean-up procedure (protein precipitation and simple dilution for plasma and urine samples, respectively) and a selective sample preparation, i.e., solid phase extraction for both matrices. The non-selective pretreatments led to significantly less ME in RPLC vs. HILIC conditions regardless of the matrix. On the contrary, HILIC appeared as a valuable alternative to RPLC for plasma and urine samples treated by a selective sample preparation. Indeed, in the case of selective sample preparation, the compounds influenced by ME were different in HILIC and RPLC, and lower and similar ME occurrence was generally observed in RPLC vs. HILIC for urine and plasma samples, respectively. The complementary of both chromatographic modes was also demonstrated, as ME was observed only scarcely for urine and plasma samples when selecting the most appropriate chromatographic mode.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This article reports the phase behavior determi- nation of a system forming reverse liquid crystals and the formation of novel disperse systems in the two-phase region. The studied system is formed by water, cyclohexane, and Pluronic L-121, an amphiphilic block copolymer considered of special interest due to its aggregation and structural proper- ties. This system forms reverse cubic (I2) and reverse hexagonal (H2) phases at high polymer concentrations. These reverse phases are of particular interest since in the two-phase region, stable high internal phase reverse emulsions can be formed. The characterization of the I2 and H2 phases and of the derived gel emulsions was performed with small-angle X-ray scattering (SAXS) and rheometry, and the influence of temperature and water content was studied. TheH2 phase experimented a thermal transition to an I2 phase when temperature was increased, which presented an Fd3m structure. All samples showed a strong shear thinning behavior from low shear rates. The elasticmodulus (G0) in the I2 phase was around 1 order of magnitude higher than in theH2 phase. G0 was predominantly higher than the viscousmodulus (G00). In the gel emulsions,G0 was nearly frequency-independent, indicating their gel type nature. Contrarily to water-in-oil (W/O) normal emulsions, in W/I2 and W/H2 gel emulsions, G0, the complex viscosity (|η*|), and the yield stress (τ0) decreased with increasing water content, since the highly viscous microstructure of the con- tinuous phase was responsible for the high viscosity and elastic behavior of the emulsions, instead of the volumefraction of dispersed phase and droplet size. A rheological analysis, in which the cooperative flow theory, the soft glass rheology model, and the slip plane model were analyzed and compared, was performed to obtain one single model that could describe the non-Maxwellian behavior of both reverse phases and highly concentrated emulsions and to characterize their microstructure with the rheological properties.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Determination of free urinary cortisol is a test of choice in the diagnosis of Cushing's syndrome. In this study, cortisol was quantified using reversed-phase high-performance liquid chromatography (RP-HPLC) in urine samples previously extracted with ether and using triamcinolone acetonide as internal standard (IS). A BDS-Hypersil-C18® column, water-acetonitrile (72:28; v/v), with a flow rate of 1.0 mL/min and detection at 243 nm were used. This method showed to be both effective and efficient, with sensitivity and linearity ranging from 2.50 to 150 μg/L, and can be used in substitution to the radioimmunoassay technique within this concentration range.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A rapid and sensitive method using high performance liquid chromatography has been developed and validated for the simultaneous determination of non-steroidal anti-inflammatory drugs (NSAIDs) in pharmaceutical formulations and human serum. Six NSAIDs including: naproxen sodium, diclofenac sodium, meloxicam, flurbiprofen, tiaprofenic and mefenamic acid were analyzed simultaneously in presence of ibuprofen as internal standard on Mediterranea C18 (5 µm, 250 x 0.46 mm) column. Mobile phase comprised of methanol: acetonitrile: H2O (60:20:20, v/v; pH 3.35) and pumped at a flow rate of 1 mL min-1 using 265 nm UV detection. The method was linear over a concentration range of 0.25-50 µg mL-1 (r² = 0.9999).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A fast and efficient method has been developed and validated for the determination of fipronil in bovine plasma. Samples were subjected to solid-phase extraction (SPE) followed by reversed phase liquid chromatography (LC) separation, using acetonitrile/water (60:40 v/v) as the mobile phase with a flow rate of 1.0 mL/min and ultraviolet (UV) detection at 210 nm. Ethiprole was used as the internal standard (IS). The method was found to be linear over the range 5-500 ng/mL (r = 0.999). The limit of quantitation (LOQ) was validated at 5 ng/mL. The method was successfully applied to monitor plasma concentrations following subcutaneous administration of fipronil in cattle.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents an experimental research about the behavior of two-phase flows in inclined pipes. The inclination angle varied from 5° to 45° and the slurry solid concentration varied up to 15%. It was concluded that the head losses of the downward sloping pipe flow are always lower than the head losses of the horizontal flow and these are always lower than the head losses of the upward sloping pipe flow, regardless the concentration and inclination angle. It was possible to develop empirical equations to calculate the head losses of the horizontal flow and the upward and downward sloping pipe flows.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report on a laser induced photoacoustic study of the nematic-to-isotropic transition in certain commercial nematic liquid crystal mixtures, namely BL001, BL002, BL032 and BL035. A simple analysis of the experimental data using the Rosencwaig–Gersho theory shows that the heat capacities of all these compounds exhibit a sharp peak as the temperature of the sample is varied across the transition region. Also, substantial differences in the photoacoustic signal amplitudes in nematic and isotropic phases have been noticed for all the mixtures. The increased light scattering property of the nematic phase may be the reason for the enhanced photoacoustic signal amplitude in this phase.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report on a laser induced photoacoustic study of the nematic-to-isotropic transition in certain commercial nematic liquid crystal mixtures, namely BL001, BL002, BL032 and BL035. A simple analysis of the experimental data using the Rosencwaig–Gersho theory shows that the heat capacities of all these compounds exhibit a sharp peak as the temperature of the sample is varied across the transition region. Also, substantial differences in the photoacoustic signal amplitudes in nematic and isotropic phases have been noticed for all the mixtures. The increased light scattering property of the nematic phase may be the reason for the enhanced photoacoustic signal amplitude in this phase

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report on a laser induced photoacoustic study of the nematic-to-isotropic transition in certain commercial nematic liquid crystal mixtures, namely BL001, BL002, BL032 and BL035. A simple analysis of the experimental data using the Rosencwaig–Gersho theory shows that the heat capacities of all these compounds exhibit a sharp peak as the temperature of the sample is varied across the transition region. Also, substantial differences in the photoacoustic signal amplitudes in nematic and isotropic phases have been noticed for all the mixtures. The increased light scattering property of the nematic phase may be the reason for the enhanced photoacoustic signal amplitude in this phase.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

he phenomenon of single beam mirage effect, otherwise known as photothermal deflection (PTD) effect using a He–Ne laser beam has been employed to detect phase transitions in some liquid crystals. It has been observed that anomalous changes in amplitude occur in the PTD signal level near the transition temperature. The experimental details and the results of measurements made in liquid crystals E8, M21 and M24 are given in this paper.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we report the use of a laser induced phoroacoustic technique for the detection of multiple phase transitions in heptyl-oxy-cyanobiphenyl (70CB) and octyl-oxy-cyanobiphenyl (80CB) liquid crystals. The observed photoacoustic signal amplitude profile carries clear signatures of two tirst order transitions in 70CB and two tirst order and a second order transitions in 80CB. Analysis of the experimental data using Rosencwaig-Gersho theory shows that the sudden decrease in the photoacoustic (PA) signal amplitude during phase transitions is due to a sharp increase in the heat capacity of the samples near the transition temperatures.