976 resultados para Immediate implants
Resumo:
The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This clinical report describes an adult patient referred for orthodontic treatment with mini-implants as anchorage to correct the root angulation of maxillary lateral incisors. The purpose of this report was to demonstrate the versatility of mini-implants placed in a vertical direction in esthetic areas. During orthodontic treatment, some aspects must be observed to preserve the interim restoration against the occlusal loads to avoid screw fracture. A fixed appliance was placed to correct the position of the maxillary anterior teeth and to complete the treatment. Acceptable esthetics and function were achieved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Bone quality and quantity are important factors with regard to the survival rate of dental implants. The aim of this study was to conduct a systematic review of dental implants inserted in low-density bone and to determine the survival rate of dental implants with surface treatments over time. A systematic review of the literature was undertaken by two independent individuals; the Medline/PubMed database was searched for the period July 1975 to March 2013. Relevant reports on bone quality and osseointegration of dental implants were selected. The search retrieved 1018 references, and after inclusion and exclusion criteria were applied, 19 studies were selected for review. A total of 3937 patients, who had received a total of 12,465 dental implants, were analyzed. The survival rates of dental implants according to the bone density were: type I, 97.6%; type II, 96.2%; type III, 96.5%; and type IV, 88.8%. The survival rate of treated surface implants inserted in low-density bone was higher (97.1%) than that of machined surface implants (91.6%). Surface-treated dental implants inserted in low-density bone have a high survival rate and may be indicated for oral rehabilitation. However, more randomized studies are required to better evaluate this issue.
Resumo:
Because of the functional and esthetic requirements of patients, different techniques have been proposed to reduce the time between dental implant placement and interim restoration fabrication. This article describes a modified indexing technique by using a surgical template for open-tray impression and definitive cast development during immediate loading procedures. This technique does not use a complete impression of the oral cavity and, therefore, is more comfortable, less time consuming, and less expensive. It also allows the fabrication of interim restorations with the optimal shape for developing an adequate emergence profile.
Resumo:
Objective: To study bony and soft tissue changes at implants installed in alveolar bony ridges of different widths.Material and methods: In 6 Labrador dogs, the mandibular premolars and first molars were extracted, and a buccal defect was created in the left side at the third and fourth premolars by removing the buccal bone and the inter-radicular and interdental septa. Three months after tooth extraction, full-thickness mucoperiosteal flaps were elevated, and implants were installed, two at the reduced (test) and two at the regular-sized ridges (control). Narrow or wide abutments were affixed to the implants. After 3 months, biopsies were harvested, and ground sections prepared for histological evaluation.Results: A higher vertical buccal bony crest resorption was found at the test (1.5 +/- 0.7 mm and 1.0 +/- 0.7 mm) compared to the control implants (1.0 +/- 0.5 mm and 0.7 +/- 0.4 mm), for both wide and narrow abutment sites. A higher horizontal alveolar resorption was identified at the control compared to the test implants. The difference was significant for narrow abutment sites. The peri-implant mucosa was more coronally positioned at the narrow abutment, in the test sites, while for the control sites, the mucosal adaptation was more coronal at the wide abutment sites. These differences, however, did not reach statistical significance.Conclusions: Implants installed in regular-sized alveolar ridges had a higher horizontal, but a lower vertical buccal bony crest resorption compared to implants installed in reduced alveolar ridges. Narrow abutments in reduced ridges as well as wide abutments in regular-sized ridges yielded less soft tissue recession compared to their counterparts.
Resumo:
Autogenous bone grafting is the gold-standard technique for bone augmentation procedures prior to implant placement. If the amount of available intraoral donor bone is insufficient, it is necessary to harvest bone graft from extraoral sites, such as calvaria. Although this technique is well established, only a few case reports show the histological analysis of the grafted bone at the moment of implant placement. This article reports the case of a 48-year-old female patient with a critical atrophic maxillary ridge reconstructed using autogenous calvarial bone graft prior to implant placement, with clinical and histological evaluation. Bone was collected under general anesthesia from the parietal bone. The outer cortical originated the bone blocks, and the medullar bone layer between was collected to be used in the sinus augmentation procedure, together with 5 of the bone blocks triturated. Six months after bone augmentation, 8 implants were placed in the grafted area and 2 biopsies were retrieved (anterior and the posterior regions), allowing the visualization of the bone-remodeling process in the grafted areas. The patient had a stable recovery. Our results showed that although necrotic bone could still be seen in the outer layer of the grafted area, the interface between this necrotic bone and the already remodeled bone was consistent with biocompatibility. Two-year radiographic evaluation showed success of the grafts and the implants in supporting an esthetic and functionally stable prosthesis. Summarizing, calvarial bone grafts are a viable alternative for the attainment of adequate bone volume prior to implant placement.
Resumo:
Objectives: the purpose of this study was to evaluate the surfaces of commercially pure titanium (cpTi) implants surface modified by laser beam (LS), by laser beam associated with sodium silicate deposition (SS) and compare them with surfaces modified by dual-acid etched (AS) and with machined surface (MS). Methods: thirty rabbits received two implants each (one for each tibia). After 30, 60 and 90 days postoperative, the implants were removed by reverse torque for biomechanical analysis and surfaces were analyzed by scanning electron microscopy (SEM) and X-ray energy dispersive spectroscopy (EDS). Results: the mean values of reverse torque at 30, 60 and 90 days postoperative were respectively 24.60, 43.60 e 60.40 N.cm to MS, 43.00, 68.20 e 63.80 N.cm to AS group, 59.80, 76.60 e 78.00 N.cm to LS group and 63.00, 75.40 e 76.60 N.cm to SS group. At 30 days, LS and SS groups showed statistically significant difference (p<0.05) compared to the other groups. At 60 days, LS and SS groups showed statistically significant difference (p<0.05) when compared to MS. Conclusions: it was concluded that SL and SS implants' biomechanical and topographical properties increased bone-implant interaction when compared to the AS and MS implants.
Resumo:
Objective: The aim of this study is to evaluate by histometric and immunohistochemistry analysis the effects of antimicrobial photodynamic therapy (aPDT) in alveolar prior to placement of mini-implants in animals with or without induced periodontal disease. Material and method: Thirty-two rats were used. Periodontal disease (PD) was induced by ligature in the lower left first molar. After 7 days of PD evolution, it was performed removal of the ligature and extraction of the left lower first molars in all animals. Thus, animals were divided into 2 groups (n=16) according to the treatments in the dental alveolus before immediate implant installation: MD (control) : mechanical debridement (MD), irrigation with 1 ml of saline solution followed by implant installation; aPDT- MD, irrigation with 1 ml of Toluidine Blue-O and low intensity laser (LLLT) and implant installation. Eight animals from each group were euthanized at 15 and 30 days after the installation of mini-implants. Specimens were processed for histologic, immunohistochemical and histometric analysis. The histometric data were processed for statistical analysis (Kruskall-Wallis and Dunn test; p <0.05). Result: In treatment analysis, results indicated that there was a greater BIC in implants installed in uncontaminated alveolus treated with a PDT ( p<0,05) and greater imuno-reactivity to OPG in bone issue treated with aPDT. Conclusion: The aPDT proved to be effective in bone loss control in no contaminated area and it has increased the bone loss and metabolic activity in alveolus irradiated prior to implant installation.
Resumo:
Aim: To demonstrate the magnitude and direction of skeletal changes in the maxilla and mandible during and after the use of bionator, as well as their rotations. Methods: Partial superimposition on the maxilla and mandible on the metallic implants and total superimposition on the cranial base were performed at three periods, T1 before bionator therapy, T2 after bionator therapy, and T3 5.68 years after T2. Results: There was total clockwise maxillary rotation and counterclockwise mandibular rotation, in the North American technique, throughout the study period, as well as extensive remodeling on the condylar region, especially in vertical direction and on the gonial region in horizontal direction. Conclusions: The total maxillary rotation seemed to be significantly affected by therapy than the mandible. There was a clear change in the direction of condylar remodeling compared to the period of bionator therapy and posterior bionator therapy. Considering the entire study period, it was observed that intra-matrix rotation of the maxilla and mandible masked their total rotation, causing minimum changes in the matrix rotation.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
To evaluate the short-term response of human pulps to ethanol-wet bonding technique. Methods Deep class V cavities were prepared on 17 sound premolars and divided into three groups. After acid-etching, the cavities from groups 1 (G1) and 2 (G2) were filled with 100% ethanol or distilled water, respectively, for 60 s before the application of Single Bond 2. In group 3 (G3, control), the cavity floor was lined with calcium hydroxide before etching and bonding. All cavities were restored with resin composite. Two teeth were used as intact control. The teeth were extracted 48 h after the clinical procedures. From each tooth serial sections were obtained and stained with haematoxylin and eosin (H/E) and Masson's trichrome. Bacteria microleakage was assessed using Brown & Brenn. All sections were blindly evaluated for five histological features. Results Mean remaining dentine thickness was 463 ± 65 μm (G1); 425 ± 184 μm (G2); and 348 ± 194 μm (G3). Similar pulp reactions followed ethanol- or water-wet bonding techniques. Slight inflammatory responses and disruption of the odontoblast layer related to the cavity floor were seen in all groups. Stained bacteria were not detected in any cavities. Normal pulp tissue was observed in G3 except for one case. Conclusions After 48 h, ethanol-wet bonding does not increase pulpal damage compared to water-wet bonding technique. Clinical significance Ethanol-wet bonding may increase resin-dentine bond durability. This study reported the in vivo response of human pulp tissue when 100% ethanol was applied previously to an etch-and-rinse simplified adhesive system.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper presents a case report with the use of short dental implants and immediate prosthesis placement. After 13 months of follow-up, peri-implant probing values are near 1.87 mm and ISQ values around 78.56.