861 resultados para Housing Mix


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Manufactured housing has been found to have substantial levels of formaldehyde in the indoor air. Because mobile homes are more affordable than conventional housing, there has been a large increase in their use in the U.S. This increase in mobile home use has been substantial in the sunbelt regions such as Texas, where high temperatures and humidities may enhance out-gassing of formaldehyde and other volatile organic compounds from construction and furnishing materials and increase any potential health hazards.^ The influences of environmental, architectural and temporal factors on the presence of indoor formaldehyde and other organic compounds were investigated in conjunction with the Texas Indoor Air Quality Study of manufactured housing. A matched pair of mobile homes, one with electric heating and cooking utilities and the other with propane gas utilities, were used for a series of controlled experiments over a fourteen month period from October, 1982 through November, 1983.^ Over this fourteen month period formaldehyde levels decreased approximately 33%. Daily fluctuations of 20% to 40% were observed even with a constant indoor temperature. An increase in indoor temperature of 8(DEGREES)C doubled the measured formaldehyde concentration. Opening windows resulted in decreases of indoor formaldehyde levels of up to 50%. Studies of the impact of propane as a cooking source showed no increase in formaldehyde levels with stove use.^ The presence and concentration of selected volatile organic compounds is influenced greatest by occupancy. Occupants continually open and close windows and doors, vary the operation and settings (temperature) of air control systems, and vary in their selection of furnishings and use of consumer products, which may act as sources of indoor air contaminants. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular events involved in specification of early hematopoietic system are not well known. In Xenopus, a paired-box homeodomain family (Mix.1–4) has been implicated in this process. Although Mix-like homeobox genes have been isolated from zebrafish (bon), chicken (CMIX) and mice (MmI/MIXL1), isolation of a human Mix-like gene has remained elusive. ^ We have recently isolated and characterized a novel human Mix-like homeobox gene with a predicted open reading frame of 232 amino acids designated the Mix.1 homeobox (Xenopus laevis)-like gene (MIXL). The overall identity of this novel protein to CMIX and MmI/MIXL1 is 41% and 69%, respectively. However, the identity in the homeodomain is 66% to that of Xenopus Mix.1, 79% to that of CMIX, and 94% to that of MmI/MIXL1. In normal hematopoiesis, MIXL expression appears to be restricted immature B and T lymphoid cells. Several acute leukemic cell lines of B, T and myeloid lineages express MIXL suggesting a survival/block in differentiation advantage. Furthermore, Xenopus animal cap assay revealed that MIXL could induce expression of the α-globin gene, suggesting a functional conservation of the homeodomain. ^ Biochemical analysis revealed that MIXL proteins are phosphorylated at multiple sites. Immunoprecipitation and immunoblotting confirmed that MIXL is tyrosine phosphorylated. Mutational analysis determined that Tyr20 appears to be the site for phosphorylation. However, deletion analysis preliminarily showed that the proline-rich domain appears not to be necessary for tyrosine phosphorylation. The novel finding will help us make a deeper understanding of the regulation on homeodomain proteins by rarely reported tyrosine phosphorylation. ^ Taken together, isolation of the MIXL gene is the first step toward understanding novel regulatory circuits in early hematopoietic differentiation and malignant transformation. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The common occurrence of parallel phenotypic patterns suggests that a strong relationship exists between ecological dynamics and micro-evolution. Comparative studies from a large number of populations under varying sets of ecological drivers could contribute to a better understanding of this relationship. We used data on morphology of arctic charr (Salvelinus alpinus) and ecological factors from 35 Icelandic lakes to test the hypothesis that morphological patterns among monomorphic charr populations from different lakes are related to interlake variation in ecological characteristics. There is extensive phenotypic diversity among populations of Icelandic charr, and populations are easily distinguished based on overall body morphology. The results obtained in the present study showed that the morphological diversity of charr was related to large-scale diversity in lake ecology. Variation in charr morphology was related to water origin (e.g. spring fed versus run-off), bedrock age, and fish community structure. The present study shows how various ecological factors can shape the biological diversity that we observe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Rangoon/Yangon, the ex-capital city of Burma/Myanmar, there still remain many old buildings today. Those buildings were constructed in the British colonial period, especially from the 1900s to the 1930s, and formed Rangoon's built environment as something modern. In focusing on the period before and after the inauguration of the Rangoon Development Trust in 1921, this paper describes how the colonial administrative authorities perceived urban problems and how their policy and practice affected urban society. It also suggests the possibility that competition for habitation among the lower strata of Rangoon society was a cause of the serious urban riot in 1930.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este artículo expone la primera aplicación experimental de un método para el análisis y la comparación de experiencias de vivienda social internacional en el contexto de las grandes áreas metropolitanas. El método, desarrollado en la Universidad Politécnica Universidad Politécnica de Madrid (UPM) desde 2009, se basa en la utilización de códigos gráficos y numéricos comunes y la integración de diferentes escalas de aproximación al entorno construido, de la vivienda y su arquitectura, a sus materiales de construcción y llegando más lejos, la ciudad. Además, los datos están vinculados a tres conceptos clave estrechamente relacionados con las condiciones específicas de las grandes áreas metropolitanas: la economía, la densidad y la diversidad. El objetivo final de la investigación es proporcionar una herramienta para la evaluación de la calidad de las viviendas sociales, optimización de recursos y un diseño innovador.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper studies the relationship between residential environment and building value. This allows us to know the elements of definition of the value of a particular housing market area and the variables that define that price. The objective of the research is to identify patterns within the residential housing market in the city area of Madrid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-cost, plastic-injected optics mix light from different color LED dies without a significant decrease in average brightness, simplifying luminaire design both optically and electronically. In solid-state lighting, high-flux and high-color rendering index (CRI) light engines may be achieved by arraying and mixing the light from different color dies or phosphors, or a combination of the two, in the LED package. However, these nonhomogeneous sources, when combined with luminaire optics, tend to produce patterns with undesirable artifacts such as spatial and angular nonuniformities and color separation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proceedings of the 12th DOCOMOMO International Conference

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to a growing concern over global warming, the bituminous mixture industry is making a constant effort to diminish its emissions by reducing manufacturing and installation temperatures without compromising the mechanical properties of the bituminous mixtures. The use of mixtures with tyre rubber has demonstrated that these mixtures can be economical and ecological and that they improve the behaviour of the pavements. However, bituminous mixtures with a high rubber content present one major drawback: they require higher mixing and installation temperatures due to the elevated viscosity caused by the high rubber content and thus they produce larger amounts of greenhouse gas emissions than conventional bituminous mixtures. This article presents a study of the effect of four viscosity-reducing additives (Sasobit®, Asphaltan A®, Asphaltan B® and Licomont BS 100®) on a bitumen modified with 15% rubber. The results of this study indicate that these additives successfully reduce viscosity, increase the softening temperature and reduce penetration. However, they do not have a clear effect on the test for elastic recovery and ductility at 25 °C.