900 resultados para Buildings -- Repair an reconstruction -- Contests


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Copyright © 2014 Entomological Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabalho de Projeto para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Edificações

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção de grau de Mestre em Engenharia Civil na Área de Especialização de Edificações

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintaining image quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children. Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality. However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength three is optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature for paediatric patients is noted. Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Renders are an important item in historical buildings and the need for their periodical re-application is a basic conservation procedure. In modern times there has been a trend towards the replacement of traditional pure lime mortars by new formulations including Portland cement or hydraulic lime. Apart from those interventions on specific and very important monuments, in which the use oftraditional non-hydraulic mortars can be enforced, in most of the projects involving less than first order magnitude heritage the use of some sort of hydraulic components is becoming the rule rather than the exception. The present paper describes and analyses the results of an experimental study with ten formulations of current mortars - including some that can hardly be considered as adequate conservation procedures - allowing a direct comparison in terms of some of the most relevant characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Estruturas

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Adhesively-bonded techniques offer an attractive option for repair of aluminium structures, and currently there are three widely used configurations, i.e., single-strap (SS), double-strap (DS) and scarf repairs. SS and DS repairs are straightforward to execute but stresses in the adhesive layer peak at the ends of the overlap. DS repairs additionally require both sides of the damaged structures to be reachable for repair, which is often not possible. In these repair configurations, some limitations emerge such as the weight, aerodynamic performance and aesthetics. The scarf repair is more complex to fabricate but stresses are more uniform along the adhesive bondline. Few studies of SS and DS repairs with embedded patches, such that these are completely flush with the adherends, are available in the literature. Furthermore, no data is available about the effects of geometrical and material parameters (e.g. the Young’s modulus of adhesive, E) on the mechanical behaviour optimization of embedded repairs. For this purpose, in this work standard SS and DD repairs, and also with embedded patches in the adherends, were tested under tension to allow the geometry optimization, by varying the overlap length (LO), thus allowing the maximization of the repairs strength. The influence of the patch embedding technique, showing notorious advantages such as aerodynamic or aesthetics, was compared in strength with standard strap repairs, for the viability analysis of its implementation. As a result of this work, some conclusions were drawn for the design optimization of bonded repairs on aluminium structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, a repair technique with adhesively bonded carbon-epoxy patches is proposed for wood members damaged by horizontal shear and under bending loads. This damage is characterized by horizontal crack growth near the neutral plane of the wood beam, normally originating from checks and shakes. The repair consists of adhesively bonded carbon-epoxy patches on the vertical side faces of the beam at the cracked region to block sliding between the beam arms. An experimental and numerical parametric analysis was performed on the patch length. The numerical analysis used the finite element method (FEM) and cohesive zone models (CZMs), with an inverse modelling technique for the characterization of the adhesive layer. Trapezoidal cohesive laws in each pure mode were used to account for the ductility of the adhesive used. To fully reproduce the tests, horizontal damage propagation within the wood beam was also simulated. A good correlation with the experiments was found. Regarding the effectiveness of the repair, for the conditions selected for this work, a full strength recovery was achieved for the bigger value of patch length tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP). Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithms has the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently. Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction. Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014). Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality. Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiation sensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brain dopamine transporters imaging by Single Photon Emission Tomography (SPECT) with 123I-FP-CIT has become an important tool in the diagnosis and evaluation of parkinsonian syndromes, since this radiopharmaceutical exhibits high affinity for membrane transporters responsible for cellular reabsorption of dopamine on the striatum. However, Ordered Subset Expectation Maximization (OSEM) is the method recommended in the literature for imaging reconstruction. Filtered Back Projection (FBP) is still used due to its fast processing, even if it presents some disadvantages. The aim of this work is to investigate the influence of reconstruction parameters for FBP in semiquantification of Brain Studies with 123I-FPCIT compared with those obtained with OSEM recommended reconstruction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Adhesive bonding is a viable technique for joining a wide range of materials. However, increasing the lifetime, reducing the costs, and improving the safety of structures are highly demanded nowadays. Hence, the development of new technologies and processes for easy recycle, heal, or self-heal of bonded structures are becoming of great interest for the industry. This paper provides an overview of the current developments in the use of “smart” adhesive technology and introduces the reader to early findings on the use of self-healing materials, thermally expandable particles, and nanoparticles, among others, in adhesives and their potential to increase the reliability of adhesive joints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada na faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In cases of extensive damage to the foot, with significant bone loss, it is generally accepted that reconstruction must include bone flaps or grafts either in the emergency setting or subsequently. In this report, we describe the case of an 18-year-old student with an avulsion injury of the dorsum of his right foot. Consequently, he lost most of the soft tissue over the dorsum of the foot and the cuboid, navicular, and cuneiform bones. A latissimus dorsi free flap was used to reconstruct the defect. A functional pseudoarthrosis developed between the remaining bones of the foot, and the patient experienced satisfactory foot function after rehabilitation. For this reason, no additional reconstructive procedure was undertaken. This case suggests that it might be adequate to use the latissimus dorsi muscle flap more liberally than previously reported in the reconstruction of extensive defects of the dorsum of the foot, including cases with significant bone loss. This option could avoid the morbidity and inconvenience of a second surgery and the need to harvest a bone flap or graft.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Long-term follow-up after endovascular aneurysm repair (EVAR) is very scarce, and doubt remains regarding the durability of these procedures. We designed a retrospective cohort study to assess long-term clinical outcome and morphologic changes in patients with abdominal aortic aneurysms (AAAs) treated by EVAR using the Excluder endoprosthesis (W. L. Gore and Associates, Flagstaff, Ariz). METHODS: From 2000 to 2007, 179 patients underwent EVAR in a tertiary institution. Clinical data were retrieved from a prospective database. All patients treated with the Excluder endoprosthesis were included. Computed tomography angiography (CTA) scans were retrospectively analyzed preoperatively, at 30 days, and at the last follow-up using dedicated tridimensional reconstruction software. For patients with complications, all remaining CTAs were also analyzed. The primary end point was clinical success. Secondary end points were freedom from reintervention, sac growth, types I and III endoleak, migration, conversion to open repair, and AAA-related death or rupture. Neck dilatation, renal function, and overall survival were also analyzed. RESULTS: Included were 144 patients (88.2% men; mean age, 71.6 years). Aneurysms were ruptured in 4.9%. American Society of Anesthesiologists classification was III/IV in 61.8%. No patients were lost during a median follow-up of 5.0 years (interquartile range, 3.1-6.4; maximum, 11.2 years). Two patients died of medical complications ≤ 30 days after EVAR. The estimated primary clinical success rates at 5 and 10 years were 63.5% and 41.1%, and secondary clinical success rates were 78.3% and 58.3%, respectively. Sac growth was observed in 37 of 142 patients (26.1%). Cox regression showed type I endoleak during follow-up (hazard ratio, 3.74; P = .008), original design model (hazard ratio, 3.85; P = .001), and preoperative neck diameter (1.27 per mm increase, P = .006) were determinants of sac growth. Secondary interventions were required in 32 patients (22.5%). The estimated 10-year rate of AAA-related death or rupture was 2.1%. Overall life expectancy after AAA repair was 6.8 years. CONCLUSIONS: EVAR using the Excluder endoprosthesis provides a safe and lasting treatment for AAA, despite the need for maintained surveillance and secondary interventions. At up to 11 years, the risk of AAA-related death or postimplantation rupture is remarkably low. The incidences of postimplantation sac growth and secondary intervention were greatly reduced after the introduction of the low-permeability design in 2004.