928 resultados para Basic polymers


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast gas chromatography with a flame ionisation detector (GC-FID) method for the simultaneous analysis of methyl palmitate (C16:0), stearate (C18:0), oleate (C18:1), linoleate (C18:2) and linolenate (C18:3) in biodiesel samples was proposed. The analysis was conducted in a customised ionic-liquid stationary-phase capillary, SLB-IL 111, with a length of 14 m, an internal diameter of 0.10 mm, a film thickness of 0.08 µm and operated isothermally at 160 °C using hydrogen as the carrier gas at a rate of 50 cm s-1 in run time about 3 min. Once methyl myristate (C14:0) is present lower than 0.5% m/m in real samples it was used as an internal standard. The method was successful applied to monitoring basic and acidic catalysis transesterification reactions of vegetable oils such as soybean, canola, corn, sunflower and those used in frying process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to create measurement system that is capable to measure performance in basic industry’s service centers. First it is examined what is performance and how it can be measured. The study also introduces commonly known measurement frameworks. After theory the study investigates how companies in the field of basic industry measure their operations in practise. The investigation is done examining three case examples and by analyzing survey results from basic industry companies. On the survey results focus is on what meters and measurement systems companies use. It is also viewed what measurement problems companies have faced. In the applied part of the study harmonized performance measurement system is created. The framework of the measurement system is introduced and measurement system for the target company is created. The target company felt that the harmonized performance measurement system has good potential and continues to develop it further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A nitrate selective electrode was prepared for use in an aggresive medium (high acidic or basic concentration). It is demonstrated that the depending E graph with respect to pNO3- has not a Nernstian response in concentration acidic range upper 0.1 mol/L H2SO4. The observed behaviour is supposed to be due to the formation of a dimeric anion HN2O6-.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid Ln-OHCO3-DMCP compounds, where Ln represents lanthanides (III) and yttrium (III) ions and DMCP is the anion 4-dimethylaminocinnamylidenepyruvate, have been prepared. Thermogravimetry, derivative thermogravimetry (TG, DTG), differential scanning calorimetry (DSC), x-Ray diffraction powder patterns and elemental analysis have been used to characterize the compounds. The thermal stability as well as the thermal decomposition of these compounds were studied using an alumina crucible in an air atmosphere.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Styrene is used in a variety of chemical industries. Environmental and occupational exposures to styrene occur predominantly through inhalation. The major metabolite of styrene is present in two enantiomeric forms, chiral R- and S- hydroxy-1-phenyl-acetic acid (R-and S-mandelic acid, MA). Thus, the concentration of MA, particularly of its enantiomers, has been used in urine tests to determine whether workers have been exposed to styrene. This study describes a method of analyzing mandelic acid using molecular imprinting techniques and HPLC detection to perform the separation of diastereoisomers of mandelic acid. The molecularly imprinted polymer (MIP) was prepared by non-covalent molecular imprinting using (+) MA, (-) MA or (+) phenylalanine, (-) phenylalanine as templates. Methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) were copolymerized in the presence of the template molecules. The bulk polymerization was carried out at 4ºC under UV radiation. The resulting MIP was grounded into 25~44¼m particles, which were slurry packed into analytical columns. After the template molecules were removed, the MIP-packed columns were found to be effective for the chromatographic resolution of (±)-mandelic acid. This method is simpler and more convenient than other chromatographic methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho investiga a degradação fotoeletrocatalítica do corante Azul Básico 41 (AB 41) amplamente utilizado na tintura de fibras sintéticas, utilizando um semicondutor Ti/TiO2 como fotoanodo. 100% de degradação foi obtida após 60 min de tratamento de 8,33x10-5 mol L-1 do corante em 0,1 mol L−1 Na2SO4, pH 2 sob densidade de corrente de 0,40 mA cm−2 e irradiação UV. Ainda foi obtido 80% de remoção de carbono orgânico total, cuja oxidação segue uma reação de pseudo-primeira ordem com constante de velocidade inicial de -0,040 mim-1 e uma eficiência de corrente de 51%. Os resultados são superiores á fotocatálise convencional nas mesmas condições sem a polarização do fotoanodo que leva a 65% de mineralização sob constante de velocidade de -0,024 mim-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cutin and suberin are structural and protective polymers of plant surfaces. The epidermal cells of the aerial parts of plants are covered with an extracellular cuticular layer, which consists of polyester cutin, highly resistant cutan, cuticular waxes and polysaccharides which link the layer to the epidermal cells. A similar protective layer is formed by a polyaromatic-polyaliphatic biopolymer suberin, which is present particularly in the cell walls of the phellem layer of periderm of the underground parts of plants (e.g. roots and tubers) and the bark of trees. In addition, suberization is also a major factor in wound healing and wound periderm formation regardless of the plants’ tissue. Knowledge of the composition and functions of cuticular and suberin polymers is important for understanding the physiological properties for the plants and for nutritional quality when these plants are consumed as foods. The aims of the practical work were to assess the chemical composition of cuticular polymers of several northern berries and seeds and suberin of two varieties of potatoes. Cutin and suberin were studied as isolated polymers and further after depolymerization as soluble monomers and solid residues. Chemical and enzymatic depolymerization techniques were compared and a new chemical depolymerization method was developed. Gas chromatographic analysis with mass spectrometric detection (GC-MS) was used to assess the monomer compositions. Polymer investigations were conducted with solid state carbon-13 cross polarization magic angle spinning nuclear magnetic resonance spectroscopy (13C CP-MAS NMR), Fourier transform infrared spectroscopy (FTIR) and microscopic analysis. Furthermore, the development of suberin over one year of post-harvest storage was investigated and the cuticular layers from berries grown in the North and South of Finland were compared. The results show that the amounts of isolated cuticular layers and cutin monomers, as well as monomeric compositions vary greatly between the berries. The monomer composition of seeds was found to differ from the corresponding berry peel monomers. The berry cutin monomers were composed mostly of long-chain aliphatic ω-hydroxy acids, with various mid-chain functionalities (double-bonds, epoxy, hydroxy and keto groups). Substituted α,ω-diacids predominated over ω-hydroxy acids in potato suberin monomers and slight differences were found between the varieties. The newly-developed closed tube chemical method was found to be suitable for cutin and suberin analysis and preferred over the solvent-consuming and laborious reflux method. Enzymatic hydrolysis with cutinase was less effective than chemical methanolysis and showed specificity towards α,ω-diacid bonds. According to 13C CP-MAS NMR and FTIR, the depolymerization residues contained significant amounts of aromatic structures, polysaccharides and possible cutan-type aliphatic moieties. Cultivation location seems to have effect on cuticular composition. The materials studied contained significant amounts of different types of biopolymers that could be utilized for several purposes with or without further processing. The importance of the so-called waste material from industrial processes of berries and potatoes as a source of either dietary fiber or specialty chemicals should be further investigated in detail. The evident impact of cuticular and suberin polymers, among other fiber components, on human health should be investigated in clinical trials. These by-product materials may be used as value-added fiber fractions in the food industry and as raw materials for specialty chemicals such as lubricants and emulsifiers, or as building blocks for novel polymers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intensive and critical care nursing is a speciality in its own right and with its own nature within the nursing profession. This speciality poses its own demands for nursing competencies. Intensive and critical care nursing is focused on severely ill patients and their significant others. The patients are comprehensively cared for, constantly monitored and their vital functions are sustained artificially. The main goal is to win time to cure the cause of the patient’s situation or illness. The purpose of this empirical study was i) to describe and define competence and competence requirements in intensive and critical care nursing, ii) to develop a basic measurement scale for competence assessment in intensive and critical care nursing for graduating nursing students, and iii) to describe and evaluate graduating nursing students’ basic competence in intensive and critical care nursing by seeking the reference basis of self-evaluated basic competence in intensive and critical care nursing from ICU nurses. However, the main focus of this study was on the outcomes of nursing education in this nursing speciality. The study was carried out in different phases: basic exploration of competence (phase 1 and 2), instrumentation of competence (phase 3) and evaluation of competence (phase 4). Phase 1 (n=130) evaluated graduating nursing students’ basic biological and physiological knowledge and skills for working in intensive and critical care with Basic Knowledge Assessment Tool version 5 (BKAT-5, Toth 2012). Phase 2 focused on defining competence in intensive and critical care nursing with the help of literature review (n=45 empirical studies) as well as competence requirements in intensive and critical care nursing with the help of experts (n=45 experts) in a Delphi study. In phase 3 the scale Intensive and Critical Care Nursing Competence Scale (ICCN-CS) was developed and tested twice (pilot test 1: n=18 students and n=12 nurses; pilot test 2: n=56 students and n=54 nurses). Finally, in phase 4, graduating nursing students’ competence was evaluated with ICCN-CS and BKAT version 7 (Toth 2012). In order to develop a valid assessment scale of competence for graduating nursing students and to evaluate and establish the competence of graduating nursing students, empirical data were retrieved at the same time from both graduating nursing students (n=139) and ICU nurses (n=431). Competence can be divided into clinical and general professional competence. It can be defined as a specific knowledge base, skill base, attitude and value base and experience base of nursing and the personal base of an intensive and critical care nurse. Personal base was excluded in this self-evaluation based scale. The ICCN-CS-1 consists of 144 items (6 sum variables). Finally, it became evident that the experience base of competence is not a suitable sum variable in holistic intensive and critical care competence scale for graduating nursing students because of their minor experience in this special nursing area. ICCN-CS-1 is a reliable and tolerably valid scale for use among graduating nursing students and ICU nurses Among students, basic competence of intensive and critical care nursing was self-rated as good by 69%, as excellent by 25% and as moderate by 6%. However, graduating nursing students’ basic biological and physiological knowledge and skills for working in intensive and critical care were poor. The students rated their clinical and professional competence as good, and their knowledge base and skill base as moderate. They gave slightly higher ratings for their knowledge base than skill base. Differences in basic competence emerged between graduating nursing students and ICU nurses. The students’ self-ratings of both their basic competence and clinical and professional competence were significantly lower than the nurses’ ratings. The students’ self-ratings of their knowledge and skill base were also statistically significantly lower than nurses’ ratings. However, both groups reported the same attitude and value base, which was excellent. The strongest factor explaining students’ conception of their competence was their experience of autonomy in nursing. Conclusions: Competence in intensive and critical care nursing is a multidimensional concept. Basic competence in intensive and critical care nursing can be measured with self-evaluation based scale but alongside should be used an objective evaluation method. Graduating nursing students’ basic competence in intensive and critical care nursing is good but their knowledge and skill base are moderate. Especially the biological and physiological knowledge base is poor. Therefore in future in intensive and critical care nursing education should be focused on both strengthening students’ biological and physiological knowledge base and on strengthening their overall skill base. Practical implications are presented for nursing education, practice and administration. In future, research should focus on education methods and contents, mentoring of clinical practice and orientation programmes as well as further development of the scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is remarkable the reduction in the number of medical students choosing general surgery as a career. In this context, new possibilities in the field of surgical education should be developed to combat this lack of interest. In this study, a program of surgical training based on learning with models of low-fidelity bench is designed as a complementary alternative to the various methodologies in the teaching of basic surgical skills during medical education, and to develop personal interests in career choice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical students must have domain of basic surgery skills before starting more advanced stages of surgical learning. The authors present a practical and reproducible system of operative techniques circuit, idealized and often applied to the fourth year medical students of a private educational institution. This method has enabled accurate assessment of students' skills, improving their performance and preparing them for more advanced stages of the surgical learning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ion exchange membranes are indispensable for the separation of ionic species. They can discriminate between anions and cations depending on the type of fixed ionic group present in the membrane. These conventional ion exchange membranes (CIX) have exceptional ionic conductivity, which is advantageous in various electromembrane separation processes such as electrodialysis, electrodeionisation and electrochemical ion exchange. The main disadvantage of CIX membranes is their high electrical resistance owing to the fact that the membranes are electronically non conductive. An alternative can be electroactive ion exchange membranes, which are ionically and electronically conducting. Polypyrrole (PPy) is a type of electroactive ion exchange material as well as a commonly known conducting polymer. When PPy membranes are repeatedly reduced and oxidised, ions are pumped through the membrane. The main aim of this thesis was to develop electroactive cation transport membranes based on PPy for the selective transport of divalent cations. Membranes developed composed of PPy films deposited on commercially available support materials. To carry out this study, cation exchange membranes based on PPy doped with immobile anions were prepared. Two types of dopant anions known to interact with divalent metal ions were considered, namely 4-sulphonic calix[6]arene (C6S) and carboxylated multiwalled carbon nanotubes (CNT). The transport of ions across membranes containing PPy doped with polystyrene sulphonate (PSS) and PPy doped with para-toluene sulphonate (pTS) was also studied in order to understand the nature of ion transport and permeability across PPy(CNT) and PPy(C6S) membranes. In the course of these studies, membrane characterisation was performed using electrochemical quartz crystal microbalance (EQCM) and scanning electron microscopy (SEM). Permeability of the membranes towards divalent cations was explored using a two compartment transport cell. EQCM results demonstrated that the ion exchange behaviour of polypyrrole is dependent on a number of factors including the type of dopant anion present, the type of ions present in the surrounding medium, the scan rate used during the experiment and the previous history of the polymer film. The morphology of PPy films was found to change when the dopant anion was varied and even when the thickness of the film was altered in some cases. In nearly all cases the permeability of the membranes towards metal ions followed the order K+ > Ca2+ > Mn2+. The one exception was PPy(C6S), for which the permeability followed the order Ca2+ ≥ K+ > Mn2+ > Co2+ > Cr3+. The above permeability sequences show a strong dependence on the size of the metal ions with metal ions having the smallest hydrated radii exhibiting the highest flux. Another factor that affected the permeability towards metal ions was the thickness of the PPy films. Films with the least thickness showed higher metal ion fluxes. Electrochemical control over ion transport across PPy(CNT) membrane was obtained when films composed of the latter were deposited on track-etched Nucleopore® membranes as support material. In contrast, the flux of ions across the same film was concentration gradient dependent when the polymer was deposited on polyvinylidene difluoride membranes as support material. However, electrochemical control over metal ion transport was achieved with a bilayer type of PPy film consisting of PPy(pTS)/PPy(CNT), irrespective of the type of support material. In the course of studying macroscopic charge balance during transport experiments performed using a two compartment transport cell, it was observed that PPy films were non-permselective. A clear correlation between the change in pH in the receiving solution and the ions transported across the membrane was observed. A decrease in solution pH was detected when the polymer membrane acted primarily as an anion exchanger, while an increase in pH occurred when it functioned as a cation exchanger. When there was an approximately equal flux of anions and cations across the polymer membrane, the pH in the receiving solution was in the range 6 - 8. These observations suggest that macroscopic charge balance during the transport of cations and anions across polypyrrole membranes was maintained by introduction of anions (OH-) and cations (H+) produced via electrolysis of water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kristiina Hormia-Poutasen esitys KRE-konferenssissa 2013.