869 resultados para BIOMECHANICAL TESTING


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Platelet P2YI2 receptor inhibition with clopidogrel, prasugrel or ticagrelor plays a key role to prevent recurrent ischaemic events after percutaneous coronary intervention in acute coronary syndromes or elective settings. The degree of platelet inhibition depends on the antiplatelet medication used and is influenced by clinical and genetic factors. A concept of therapeutic window exists. On one side, efficient anti-aggregation is required in order to reduce cardio-vascular events. On the other side, an excessive platelet inhibition represents a risk of bleeding complications. This article describes the current knowledge about some platelet function tests and genetic tests and summarises their role in the clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of the current study was to investigate the biomechanical stability and fixation strength provided by a posterior approach reconstruction technique to realign the craniovertebral junction.¦METHODS: We tested seven human cadaver occipito-cervical spines (occiput-C4) by applying pure moments of ±1.5 Nm on a spine tester. Each specimen was tested in the following modes: 1) intact; 2) injured; 3) spacers alone at C1-C2 articulation (S); 4) spacers plus C1-C2 Posterior Instrumentation (S+PI); and 5) spacers plus C1-C2 posterior instrumentation plus midline wiring (S+PI+MLW). C1-C2 range of motion for each construct was obtained in flexion-extension, lateral bending, and axial rotation.¦RESULTS: In all the loading modes, S, S+PI, and S+PI+MLW constructs significantly reduced range of motion compared with the intact and injured condition (P < 0.05). There was no statistical difference between any of the three instrumentation constructs (P > 0.05).¦CONCLUSIONS: This study investigated the biomechanics of the posterior approach technique for realignment of the craniovertebral junction and also made comparisons with additional posterior fixations. The stand-alone spacers were stable in all three loading modes. Posterior instrumentation increased the stability as compared to stand-alone spacers. The third point of fixation, carried out by using midline wiring, increased the stability further. However, there was not much difference in the stability imparted with the midline wiring versus without. The present study highlights the biomechanics of this novel concept and reaffirms the view that distraction of the C1-C2 articular facets and direct articular joint atlantoaxial fixation would be an ideal method of management of basilar invagination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integral abutment bridges are constructed without an expansion joint in the superstructure of the bridge; therefore, the bridge girders, deck, abutment diaphragms, and abutments are monolithically constructed. The abutment piles in an integral abutment bridge are vertically orientated, and they are embedded into the pile cap. When this type of a bridge experiences thermal expansion or contraction, horizontal displacements are induced at the top of the abutment piles. The flexibility of the abutment piles eliminates the need to provide an expansion joint at the inside face to the abutments: Integral abutment bridge construction has been used in Iowa and other states for many years. This research is evaluating the performance of integral abutment bridges by investigating thermally induced displacements, strains, and temperatures in two Iowa bridges. Each bridge has a skewed alignment, contains five prestressed concrete girders that support a 30-ft wide roadway for three spans, and involves a water crossing. The bridges will be monitored for about two years. For each bridge, an instrumentation package includes measurement devices and hardware and software support systems. The measurement devices are displacement transducers, strain gages, and thermocouples. The hardware and software systems include a data-logger; multiplexers; directline telephone service and computer terminal modem; direct-line electrical power; lap-top computer; and an assortment of computer programs for monitoring, transmitting, and management of the data. Instrumentation has been installed on a bridge located in Guthrie County, and similar instrumentation is currently being installed on a bridge located in Story County. Preliminary test results for the bridge located in Guthrie County have revealed that temperature changes of the bridge deck and girders induce both longitudinal and transverse displacements of the abutments and significant flexural strains in the abutment piles. For an average temperature range of 73° F for the superstructure concrete in the bridge located in Guthrie County, the change in the bridge length was about 1 118 in. and the maximum, strong-axis, flexural-strain range for one of the abutment piles was about 400 micro-strains, which corresponds to a stress range of about 11,600 psi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine the power of different exact tests of differentiation for diploid populations. Since there is not necessarily random mating within populations, the appropriate hypothesis to construct exact tests is that of independent sampling of genotypes. There are two categories of tests, FST-estimator tests and goodness of fit tests. In this latter category, we distinguish "allelic statistics", which account for the nature of alleles within genotypes, from "genotypic statistics" that do not. We show that the power of FST-estimator tests and of allelic goodness of fit tests are similar when sampling is balanced, and higher than the power of genotypic goodness of fit tests. When sampling is unbalanced, the most powerful tests are shown to belong to the allelic goodness of fit group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Individuals who are unaware of their HIV infection constitute a fragile and a critical population both from a personal and from a community-based point of view: if the infection is diagnosed too late, the outcome can be complicated by AIDS-defining diseases, whose prognosis may remain unfavourable even after the initiation of a potent antiretroviral therapy. These patients contribute to the virus spreading into the community, owing to a high viral load. It is now necessary to recognise the limits of a risk behaviour and disease-driven HIV screening policy. Since 2006, the American guidelines recommend a routine HIV testing for all patients age 13 to 64 years unless they specifically refuse the test (opt-out). In Switzerland, the recommendations remain so far risk-centred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This main report provides a general discussion of the load testing, structural evaluation, and load rating procedures. Specific details for each bridge are provided in individual report sections. Additional supporting information on load testing, analyses, and load rating are also provided in the attached appendices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Gastric banding (GB) is one of the most popular bariatric procedures for morbid obesity. Apart from causing weight loss by alimentary restriction, it can interfere with functions of the esophagus and upper stomach. The aim of this study was to evaluate if the results of extensive preoperative upper GI testing were correlated with long-term outcome and complications after GB. METHODS: Using a prospectively maintained computerized database including all the patients undergoing bariatric operations in both our hospitals, we performed a retrospective analysis of the patients who underwent complete upper gastrointestinal (GI) testing (endoscopy, pH monitoring, and manometry) before GB. RESULTS: One hundred thirty-four patients underwent complete testing before GB. Abnormal pH monitoring (increased total reflux time, increased diurnal reflux time, increased number of reflux episodes) predicted the development of complications and especially pouch dilatation and food intolerance. The mean De Meester score was higher among patients who developed complications than in the remaining ones (25.4 vs 17.7, P=0.03). High lower esophageal sphincter pressure also predicted progressive long-term food intolerance. Endoscopic findings were not predictive of the long-term outcome. CONCLUSIONS: There is some association between the function of the upper digestive tract and long-term complications after gastric banding. Abnormal pH monitoring predicts overall long-term complications, especially food intolerance with or without reflux, and pouch dilatation, and a high lower esophageal sphincter pressure predicts long-term food intolerance. Extended upper gastrointestinal testing with endoscopy, 24-h pH monitoring, and esophageal manometry is probably worthwhile in selecting patients for gastric banding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to obtain organic compounds similar to the ones found in the organic matter of anthropogenic dark earth of Amazonia (ADE) using a chemical functionalization procedure on activated charcoal, as well as to determine their ecotoxicity. Based on the study of the organic matter from ADE, an organic model was proposed and an attempt to reproduce it was described. Activated charcoal was oxidized with the use of sodium hypochlorite at different concentrations. Nuclear magnetic resonance was performed to verify if the spectra of the obtained products were similar to the ones of humic acids from ADE. The similarity between spectra indicated that the obtained products were polycondensed aromatic structures with carboxyl groups: a soil amendment that can contribute to soil fertility and to its sustainable use. An ecotoxicological test with Daphnia similis was performed on the more soluble fraction (fulvic acids) of the produced soil amendment. Aryl chloride was formed during the synthesis of the organic compounds from activated charcoal functionalization and partially removed through a purification process. However, it is probable that some aryl chloride remained in the final product, since the ecotoxicological test indicated that the chemical functionalized soil amendment is moderately toxic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La luxation d'une prothèse totale de la hanche est une complication majeure en termes de morbidité pour le patient et des coûts pour le système de santé. Cette complication est retrouvée entre 2 à 3% selon les séries (1-3) pour des prothèses primaires, et beaucoup plus élevée suite à des révisions. Pour remédier à ce problème, des systèmes de prothèses contraintes sont une option, cependant associés à des descellements fréquents entre 10 à 26 % selon les séries (4-6). Ces échecs étant en partie expliqués par une usure rapide des surfaces de frottements due aux fortes contraintes, mais également par les contraintes cupule-os occasionnant des descellements mécaniques (7). Par conséquent, pour augmenter la stabilité, tout en évitant les contraintes sur le couple de frottement, Bousquet développe, en 1976, une prothèse totale de hanche « à double mobilité ». Ce système consiste à combiner deux articulations apparentes, premièrement une tête métallique dans un insert de polyéthylène, articulé lui- même dans la concavité d'une cupule métallique fixée au bassin. En tant que tel, ce système biomécanique réduirait en théorie le risque de luxation. Dès lors, on aperçoit depuis environ 15 ans une augmentation progressive de l'utilisation de ce type d'implants que ce soit comme implant primaire ou secondaire, chez des patients jeunes ou âgés. Cependant, des études in vitro, ont montré que des grandes surfaces de friction sont associées à une augmentation de l'usure du polyéthylène (8). En revanche, les données sur la cinématique et l'usure, in vivo, de ce type d'implant étaient jusqu'alors limitées. Depuis quelques années, un certain nombre d'études cliniques avec un follow up significatif ont été publiées. CONCLUSIONS ET PERSPECTIVES FUTURES La prothèse totale de hanche à double mobilité, développée par Bousquet dans les années 1970, est un concept novateur dans l'arthroplastie totale de hanche. Depuis sa première conception, de nombreuses améliorations ont été adoptées. Cependant, ses effets à long terme sur la survie de l'implant doivent encore être effectué. Certes, des études ont montré un net effet sur la réduction du taux de luxation des prothèses primaires, lors de révision ou après résection tumorale. Toutefois, compte tenu des données limitées à long terme sur le taux d'usure et le descellement aseptique, il convient d'utiliser ce type d'implant avec prudence, en particulier lors d'arthroplastie primaire chez des patients jeunes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän diplomityön tavoitteena oli testata ja optimoida erään alipainerumpusuodattimen toimivuutta, ja lisäksi maksimoida tuottavuus ja vertailla erilaisten pesumenetelmientehokkuutta. Testilietteiden ¿ rautarikasteen ja täyteainepastan ¿ karakterisointi oli myös tärkeää. Kirjallisuusosassa tarkasteltiin lyhyesti neste-kiintoaine-erotuksen teoriaa, erityisesti alipainesuodatusta ja alipainerumpusuodattimia. Lisäksi käsiteltiin kapillaarisuodatuksen toimintaperiaatteita sekä selvitettiin kaivosteollisuuden veden talteenottokeinoja, kiintoainejäämien käsittelymenetelmiä ja Chilen kaivosteollisuuden nykytilaa. Työn kokeellinen osa suoritettiin käyttämällä raskaita ja kiintoainepitoisuuksiltaan korkeita lietteitä, eli rautarikastetta ja täyteainepastaa. Kokeet suoritettiin erityisellä alipainerumpusuodattimella, joka oli muokattu perinteisestäpäältä syötettävästä alipainerumpusuodattimesta. Kokeissa tutkittiin pyörimisnopeuden ja erilaisten pesumenetelmien vaikutusta kakun kosteuteen ja suodatuskapasiteettiin. Koelietteiden karakterisointi suoritettiin analysoimalla partikkelikokojakauma, kiintoainepitoisuus, metallipitoisuus ja koostumus. Kokeiden perusteella havaittiin, että rummun pyörimisnopeudella ja lietteen kiintoainepitoisuudella on merkittävä vaikutus suodatuskapasiteettiin ja kakun kosteuspitoisuuteen. Havaittiin myös, että kakun kosteuspitoisuuksissa ja rummun suodatuskapasiteeteissa oli eroja, kun verrattiin eri suodatinväliaineen pesumenetelmiä. Täten oikean pesumenetelmän valinta on tärkeää, ja sillä pystytään lisäämään suodatinväliaineen käyttöikää.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perushyväksymistestaus on oleellinen osa S60 alustan julkaisukandidaatin maturiteetin seurannassa. Perushyväksymistestausta tehdään myös ohjelmiston julkistamiskelpoisuuden varmistamiseksi. Testaustulokset halutaan aina mahdollisimman nopeasti. Lisäksi testaustiimin työmäärä on hiljalleen kasvanut, koska projekteja onenemmän ja korjauksia sisältäviä ja räätälöityjä settejä testataan enemmän. Tässä diplomityössä tutkitaan lyhentäisikö testisetin osan automatisointi testien ajoaikaa ja helpottaisiko se testaajien työtaakkaa. Tarkastelu toteutetaan automatisoimalla osa testisetistä ja kokemuksia esitellään tässä lopputyössä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä tutkitaan automatisoitua testausta ja käyttöliittymätestauksen tekemistä helpommaksi Symbian-käyttöjärjestelmässä. Työssä esitellään Symbian ja Symbian-sovelluskehityksessä kohdattavia haasteita. Lisäksi kerrotaan testausstrategioista ja -tavoista sekä automatisoidusta testaamisesta. Lopuksi esitetään työkalu, jolla testitapausten luominen toiminnalisuus- ja järjestelmätestaukseen tehdään helpommaksi. Graafiset käyttöliittymättuovat ainutlaatuisia haasteita ohjelmiston testaamiseen. Ne tehdään usein monimutkaisista komponenteista ja niitä suunnitellaan jatkuvasti uusiksi ohjelmistokehityksen aikana. Graafisten käyttöliittymien testaukseen käytetään usein kaappaus- ja toistotyökaluja. Käyttöliittymätestauksen testitapausten suunnittelu ja toteutus vaatii paljon panostusta. Koska graafiset käyttöliittymät muodostavat suuren osan koodista, voitaisiin säästää paljon resursseja tekemällä testitapausten luomisesta helpompaa. Käytännön osuudessa toteutettu projekti pyrkii tähän tekemällä testiskriptien luomisesta visuaalista. Näin ollen itse testien skriptikieltä ei tarvitse ymmärtää ja testien hahmottaminen on myös helpompaa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä esitellään ohjelmistotestauksen ja verifioinnin yleisiä periaatteita sekä käsitellään tarkemmin älypuhelinohjelmistojen verifiointia. Työssä esitellään myös älypuhelimissa käytettävä Symbian-käyttöjärjestelmä. Työn käytännön osuudessa suunniteltiin ja toteutettiin Symbian-käyttöjärjestelmässä toimiva palvelin, joka tarkkailee ja tallentaa järjestelmäresurssien käyttöä. Verifiointi on tärkeä ja kuluja aiheuttava tehtävä älypuhelinohjelmistojen kehityssyklissä. Kuluja voidaan vähentää automatisoimalla osa verifiointiprosessista. Toteutettu palvelin automatisoijärjestelmäresurssien tarkkailun tallentamalla tietoja niistä tiedostoon testien ajon aikana. Kun testit ajetaan uudestaan, uusia tuloksia vertaillaan lähdetallenteeseen. Jos tulokset eivät ole käyttäjän asettamien virherajojen sisällä, siitä ilmoitetaan käyttäjälle. Virherajojen ja lähdetallenteen määrittäminen saattaa osoittautua vaikeaksi. Kuitenkin, jos ne määritetään sopivasti, palvelin tuottaa hyödyllistä tietoa poikkeamista järjestelmäresurssien kulutuksessa testaajille.